GE(NS) KOCHI
Military Engineer Services Garrison Engineer (Naval Services) Kataribagh, Naval Base Post Kochi , 682 004
PREVENTIVE MAINTENANCE OF SCREW CHILLER 3 X 120 TR CAPACITY INSTALLED IN NAY(K) AND PREVENTIVE MAINTENANCE OF DE HUMIDIFIER AT FATS GARUDA AND ROUTINE MAINTENANCE OF VRF AC PLANTS AT CRL,ASR,DIVING SCHOOL AT NAVAL BASE KOCHI
2020_MES_384342_2
8736/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
Kochi
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE(NS) KOCHI
₹80,600
Yes
20 Jan 2021
2 Nov 2020
26 Nov 2020
2 Nov 2020
24 Nov 2020
10 Nov 2020
2 Nov 2020 - 9 Nov 2020
Amount
Material & Labour for Quarterly servicing of maintenance and check up of Dunham bush chiller unit complete accessories controls comprising of rotary screw compressors with standard fittings electric motor with double delta starter of suitable capacity for rotary screw compressor hermetically sealed water cooled 2X120 TR=240 TR in operation and 1X120 TR as stand by suitable for operation on R-22 , DX evaporator ,Shell and tube condenser , suitable expansion device , chilled water pump 15 HP -3 Nos, condenser water pump 20 HP-3 Nos and induced draft cooling tower FRP type 240 TR capacity . The entire system to be checked for quarterly interval up to contract duration and breakdown attention by suitable technician to made serviceable in case of any breakdown observed during the routine check and made functional the AC plant entire contract execution period installed at Pegasus Bldg, NAY(K).
Supply and Replacement of microprocessor display of model PGD1 CAREL MAKE132X64 PIXELPGD ITERMINAL of Make Dunham bush Chiller control panel with necessary programming, soft ware installation & panel modification in chiller capacity of (1 x 120 TR).
Supply and replacement of Liquid level switch Cat no- H009956A7 of VOLTAS make, complete all as specified and directed
Supply and replacement of modular motor Cat no- HWM9494D1000 of VOLTAS make, complete all as specified and directed
Material & Labour for Quarterly Cleaning 03 Nos of shell and tube condenser capacity of 120 TR by chemical and mechanical process using maic / hydride decaling compound/cleaning rod etc, after opening with both sides of condensers brushing and reconnecting with suitable size of packing /gasket in same position including testing as directed by Engineer-in-Charge.
Material & labour for Quarterly servicing of cooling tower of cap 240 TR capacity AC Plant including removing of top Metal grill cover and cleaning the PVC Fills , alignment in proper way, replacement of rusted nuts, bolts with washers etc and clearing bottom tank to remove mud and dust complete all as directed by Engineer-in-charge.
Supply and replacement of Fan blade of 2400 mm length, 6 leaf , aluminium alloy, dynamically balanced fan Tie rod assembly for 240 TR capacity cooling tower including branch pipes, circular HUB, Flaps, Fittings MS clamps etc complete all as specified and directed.
M & L for dismantling of unserviceable condenser coil from air cooled condensing unit and replace with new condenser coil of length up to 50 cm, Height upto 70 cm, with 3/8'' copper pipe (number of rows as per existing coil) with aluminium fins including brazing/welding and re fixing all accessories including testing all as specified and directed . Make of Condensing Unit: Voltas.
Supply and charging of Refrigerant Gas R 22 in sealed cylinder including leak testing by using nitrogen gas all as specified and directed by Engineer in Charge. Note :- Nitrogen will be measured and paid separately
Supply and charging of Refrigerant Gas R 134 a
Supply and charging of Refrigerant Gas R 410 a
Supply and charging of Refrigerant Gas R 407 c
Supply and charging of Nitrogen gas in sealed cylinder comprising 12 PSI filled inside gas, complete all as specified and directed. Note for item No 10.00 to 13.00 1. Empty cylinder will returned to contractor after usage. 2. Testing pressure gauges, gas charging PVC leads, technicians and transporting facility for carrying( Maximum capacity cylinders upto approximately 1 ton weight) to various AC Plants shall be own arranged by contractor .
M&L for painting of central AC plant upto two chilling units i.e. including of compressors, condensers, pumps and motors, frames, panel board complete including pipe lines with two coats of synthetic enamel spray paint of existing colour after preparation of existing surface of each unit and marking set numbers , SM/MES numbers complete all as specified and directed.
M&L for painting of central AC plant for Three chilling units i.e. including of compressors, condensers, pumps and motors frames, panel board complete including pipe lines with two coats of synthetic enamel spray paint of existing colour after preparation of existing surface of each unit and marking set numbers ,SM/MES numbers all as specified and directed.
M&L for painting of central AC plant supply and return air duct with two coats of synthetic enamel spray paint of existing colour after preparation of existing surface all as specified and as directed
M&L for painting of central AC plant cooling tower with two coats of synthetic enamel spray paint of existing colour paint after preparation of existing surface upto 50 TR capacity all as specified and as directed
M&L for painting of central AC plant cooling tower with two coats of synthetic enamel spray paint of existing colour paint after preparation of existing surface 51 to 100TR capacity all as specified and as directed
M&L for painting of central AC plant cooling tower with two coats of synthetic enamel spray paint of existing colour paint after preparation of existing surface 101 TR to 200 TR capacity all as specified and as directed
Preventive maintenance and check up of Dehumidifier Installed at FATS Garuda, capacity of 4850/5000 CFM including complete accessories and controls, and the entire system to be checked and servicing by OEM or their authorised service agency for every month interval throughout CA duration and incase of any breakdown occurs at any time, the tenderer shall be attend the complaint and made serviceable with in time including minor spares such as fuses, wires, nut, bolts etc. for above mentioned all as specified and directed by Engineer-in-charge. (a) Dehumidifier Model No FLI 7300, Ser No. 2013-BAC-18620 Make: Bry-Air Note: - Major spare parts are measured and paid separately under relevant item in BOQ and labour charges for replacement shall be deemed to include in the quoted rate above.
Preventive maintenance and check up of Dehumidifier Installed at FATS Garuda, capacity of 4850/5000 CFM including complete accessories and controls and the entire system to be checked and servicing by OEM or their authorised dealer for every 30 days interval throughout CA duration and incase of any breakdown occurs at any time, the tenderer shall be attend the complaint and made serviceable with in time including minor spares such as fuses, wires, nut, bolts, etc., for above mentioned all as specified and directed by Engineer-in-charge. (a) Dehumidifier Model No FLI 7300, Ser No. 2018-BAC-28982 Make: Bry-Air Note: - Major spare parts are measured and paid separately under relevant item in BOQ and labour charges for replacement shall be deemed to include in the quoted rate above.
Supply only React filter Air inlet pre-filter all as specified and directed by Engineer-in-charge. Make:- Recommended by OEM (Bry- Air)
Supply only SSR (Solid state relay), working capacity 90-250V AC, all as specified and directed by Engineer-in-charge. Make:- Recommended by OEM (Bry- Air)
Supply only Thermostat 50-300 DEC all as specified and directed by Engineer-in-charge. Make:- Recommended by OEM (Bry- Air)
Supply only Limit Switch all as specified and directed by Engineer-in-charge. Make:- Recommended by OEM (Bry- Air)
Supply only Process filter Air inlet Pre Filter all as specified and directed by Engineer-in-charge.Make:- Recommended by OEM (Bry- Air)
Supply only Pressure Switch all as specified and directed by Engineer-in-charge. Make:- Recommended by OEM (Bry- Air)
Supply only Bed drive motor including arrangement pulley, chain, controllers complete all as specified and directed by Engineer-in-charge. Make:- Recommended by OEM (Bry- Air)
Supply only Idler bracket assembly suitable for Existing Dehumidifier, Model No. FLI 7300, Part No 43115, testing, all as specified and directed by Engineer-in-charge. Make:- Recommended by OEM (Bry- Air)
Comprehensive maintenance and Monthly routine checkup of the VRF unit of capacity 78 HP having 05 outdoor units, 8 Ceiling Suspended AHU'S and 5 Nos cassette type indoor units installed at Diving school on monthly basis including all kind of replacement of spare parts. Make: LG 1. The comprehensive maintenance contract shall be done through OEM or its authorised agency of OEM (LG) .The Contractor shall enter into a MOU (Memorandum of understanding) for Comprehensive maintenance contract with the OEM agency for the complete VRF AC plant equipments. 2. The above comprehensive AMC certificate shall be provided by the contractor in favour of GE (NS) Kochi before commencement of work, after acceptance of CA. 3. The parts shall be genuine and from original Equipment manufacturer (OEM) and approved by GE. 4. The contractor is responsible to carried out minimum one routine check up through OEM (Once in a month) or as per the direction of Engineer- in - charge to ensure the serviceability and proper functioning of the AC Plant in all respect ( each month will be consider as 01 Job) 5. The quoted rate including replacement of any kind of spares and labour cost. 6. Any Breakdown complaints shall be attended within the same day with in 24 Hrs of complaint lodged by MES.
Material and labour for Bi-Monthly services of outdoor unit of VRF system make Blue star with capacity 12 HP at ASR complex, cleaning and servicing the entire unit as per manufactures specification and reassembling the same at original position, testing the functioning all as specified and directed by Engineer in charge.
Material and Labour for Bi-monthly Servicing of VRF system, indoor units-02 nos of cassette type of having capacity 12 HP, Make Blue star at ASR complex, clean with mild Air blower in the coil side and remove the inside fine filter, cleaned with Soap solution after cleaning process fix in proper place, check the drainage water tank and cleaned, replace the communication cables and sensor if found defective all as specified and directed.
Material and labour for Bi-Monthly services of outdoor unit- 02 nos of VRF system make Voltas with capacity 24 HP at Command Ref Library bldg, cleaning and servicing the entire unit as per manufactures specification and reassembling the same at original position, testing the functioning all as specified and directed by Engineer in charge.
Material and Labour for Bi-monthly Servicing of VRF system, indoor units -05 Nos of cassette type of having capacity of 24 HP at Command Ref Library bldg, clean with mild Air blower in the coil side and remove the inside fine filter, cleaned with Soap solution after cleaning process fix in proper place, check the drainage water tank and cleaned, replace the communication cables and sensor if found defective all as specified and directed.
Supply and replacement of catch all core as suitable in existing pipe line for VRF suction/discharge line all as specified and directed
Supply only VFD controller for VRF AC of 12 HP capacity all as specified and directed. Make: Recommended by OEM blue star/Voltas.
Taking down unserviceable Digital compressor unit of VRF AC of 6 HP/5.5TR capacity and replace with new compressor unit in the existing unserviceable sealed compressor unit with and including initial charging of gas and oil all as specified and directed by Engineer in charge. MODEL :ZRD72KCTFD-433 OF VOLTAS.
Taking down unserviceable fixed compressor unit of VRF ACs of 6 HP/5.5TR capacity and replace with new compressor unit in exchange of the existing unserviceable sealed compressor unit with and including initial charging of gas and oil all as specified and directed by Engineer in charge. MAKE :ZR61KCTFD-420 OF VOLTAS.
Supply only Liquid line solenoid valve for VRF system. Make: Recommended by OEM blue star.
Supply and fixing of thermal insulation class "O" nitrile rubber insulation density 45-55 kg/m3, for suction/discharge piping of VRF pipe lines suitable size of dia as per site, complete all as specified and directed.
Checking of existing condition for DUCT area making the arrangement of visualization and the process for disinfection for indoor air quality of AC ducts of inside , connection in between plenum and branches and main plenum with mechanical machine /Manual entry, air compressor, various type of air nozzles for maintain standard indoor air quality complete all as specified and as directed. Note: Cutting at Duct branches shall be close by contractor as match the existing surfaces with insulation etc.
Preventive Maintenance of Bi monthly and check up of Bitzer Blast cold storage-14 Units condensing unit ,including replacement of minor spares if found unserviceable accessories like suction accumulator, drier, solenoid valve, moisture sight glass, ball valve, HP/LP switch, expansion valve ,etc. Machine details As follows: Blast Room (-) 30 2 ODU+2 IDU 25.HP BITZER R- 404 Fish Room (-) 18 2 ODU+2 IDU 4 HP BITZER R- 404 Meat Room (-) 18 2 ODU+2 IDU 6 HP BITZER R- 404 Vegetable Room (+) 4 2 ODU+2 IDU 6 HP BITZER R-134 Egg Room (+) 4 2 ODU+2 IDU 4 HP BITZER R- 134 Ante Room (+) 4 2 ODU+2 IDU 6 HP BITZER R- 134 Milk Room (+) 4 2 ODU+2 IDU 2 HP BITZER R-134
Supply only Compressor oil suitable for R-134 A. Make: EMKARATE
Supply only Gas (404 A) in sealed cylinder . Note: Empty cylinders to be returned to contractor after use
Amount of Credit Schedule shall be deducted to arrive the Contract Sum.
AR Traders
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .