Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹1.4 Cr
EMD Value
₹4.9 L
Closing Date
23 Oct 2026, 6:00 pm6d left
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
MANAGING DIRECTOR,GRIMCO GANDHINAGAR
CIVIL/INTERIOR/ELECTRICAL/HVAC WORK FOR SARDAR PATEL INSTITUTE OF PUBLIC ADMINISTRATION (SPIPA),GANDHINAGAR
348675
11/2026-27
Open
Miscellaneous Works
Works
Gandhinagar
3 documents required · 3 mandatory
₹17,700
GUJARAT RURAL INDUSTRIES MARKETING CORPORATION LIMITED
₹4.9 L
14 Oct 2026
14 Oct 2026
14 Oct 2026
23 Oct 2026
14 Oct 2026
Sr. No. Description Quantity Unit Rate Amount
Demolition of existing electrical work including stacking of serviceable materilas and disposal of unserviceable materials with
all lead and lift. .
Providing & laying 1st class burnt brick masonary for super structure using bricks having crushing strength not less than
2 35kg/sqcm. & set in c.m. (1:6) incl. racking & paint joints incl. scaffolding, watering, curing etc. comp. as directed. 1.00 CMT 2800.00
PLASTER WORK : Providing 15mm thk. Cement plaster in single coat on Internal Walls for interior plastering of following
3 finished even and smooth in Cement Mortar 1:3 (1-Cement : 3-Sand) incl. finishing with a floating coat of neat cement slurry. 1.00 SQMT 220.00
Supplying & fixing heavy duty 1200 X 600 mm Vitrified tiles With Epoxy Grout of 8 to 9 mm th. of Approved Brand in flooring as
per approved pattern ,& design laid over neat cement slurry & cement mortar in (1:6) bedding 20 mm th. average & joint with
4 colour cement slurry incl. special cornices, corners or angles, tiles etc. incl.Existing Removing Flooring cost and fixing materials, 1.00 SQMT 1620.00
labour, tools, plants, equipmens incl. all lead & lift comp. as directed by Architect /EIC .(Tiles as per Existing tiles Matching)
Supplying & fixing heavy duty 1200 X 600 mm Vitrified tiles of 8 to 9 mm th. of Approved Brand in Skirting With Epoxy Grout as
per approved pattern ,Match Shade with Existing Flooring & design laid over neat cement slurry & cement mortar in (1:6)
5 bedding 20 mm th. average & joint with colour cement slurry incl. special cornices, corners or angles, tiles etc. incl.Existing 1.00 SQMT 1669.00
Removing Skirting cost of fixing materials, labour, tools, plants, equipmens incl. all lead & lift comp. as directed by Architect /EIC
.(Tiles as per Existing tiles Matching)
Maintenance of existing aluminum windows with Wooden frame (to be removed & refixed) with new ribbons, clear white
gaskets, rollers, handles etc complete with applying silicon from outside to restrict the seepage of rain water. Aluminum
sections shall be powder coating of approved shade and colour after sanding surface as per instruction and Repair the Existing
Wooden Frame with Paint as per Architect and EIC Instruction.
Floor Protection Sheet Providing and applying covering on flooring for floor protection with Heavy duty bubble sheet on newly
7 placed flooring. The rate should include the cleaning of plastic on completion before handing over completed site. 869.00 SQMT 170.0
P.O.P Punning on wall : Providing and applying POP Punning on walls and columns (average 12mm to 25mm the). The rate shall
8 include scrapping, leveling and preparing the surface. The rate shall be inclusive of all types of grooves above the skirting, 939.00 SQMT 170.00
around the window and door frames. completed as directed by Project manager / Architect.
Providing fixing PLAIN GYPBOARD FALSE CEILING Providing and fixing suspended false ceiling consisting of 12.5mm thick
Gypsum board (Saint Gobain or India Gypsum) suspended on GI framework of India Gypsum / Saint Gobain. GI framework to
consist of GI perimeter channels 0.55mm thick 20mm x 30mm along perimeter of false ceiling of ceiling, screw fixed to
wall/partition with nylon sleeves and screws @ 600mm c/c. Suspending GI intermediate channels of size 0.9mm thick 45mm x
15mm from the soffit at max dist 1220mm c/c with ceiling angle 0.55mm thick 25mm x 10mm fixed to soffit using proprietary
supplied GI cleats and steel expansion fasteners.Boards to be finished with proprietary supplied jointing tape and jointing
compound and sand papered to achieve a smooth and seamless finish. and 2 coats of primer suitable for Gypsum board applied
ready to receive finish.Rate quoted to include vertical all cut-outs required for light fixtures, smoke detectors and other services
cut-outs complete as directed by Architect.Rate quoted to include cost of providing support framework formed of perimeter
channels for fixing light fixtures, AC grills/diffusers etc. Also to provide concealed perimeter channel support as required to
support modular grid ceiling sections at junction between gypboard false ceiling and modular grid tile ceiling.
Gypsum ceiling Patta ( 50mm ht to 250mm ht )- as per above specification. ( Item No : 4.1 ) (WALL AC PIPING COVERING)
TENDER FOR CIVIL/INTERIOR/ELECTRICAL/HVAC WORK FOR SARDAR PATEL INSTITUTE PUBLIC ADMINISTRATION (SPIPA), GANDHINAGAR
Sr. No. Description Quantity Unit Rate Amount
Grid ceiling : Providing and fixing 2' x 2' modular grid ceiling : providing and fixing modular ceiling systems with mineral fiber
board ceiling tiles as per following specifications, rate to include all fastening accessories with approved finishes. Fire retardant
tiles of size 600mm x 600mm x 20mm thick of approved colour and type with acoustical property of 0.0nrc, with beveled tegular
edge. ( measured on horizontal plane only.) Horizontal plane measurements are to be inclusive of all vertical drops, edge
11 mouldings, fascia's, etc. Rate quoted to include all cut-outs required for light fixtures, smoke detectors and other services cut- 196.00 SQMT 900.00
outs complete as directed by Architect. Rate quoted to include cost of providing support framework formed of perimeter
channels for fixing light fixtures, AC grills/diffusers etc. Also to provide concealed perimeter channel support as required to
support modular grid ceiling sections at junction between gypboard false ceiling and modular grid tile ceiling.
Wooden Laminate Design finish Rafter Partition ( 100mm x 50mm thick.) Providing and fixing wooden Rafter type partition
using 100mm x 50mm made out of solid plywood covered with 1mm thick approved shade of laminate finish at spacing not
exceeding 150mm C/C horizontal including supports at floor level and slab/ ceiling level , using 50mm X 50mm X 1.5mm thick "L"
angle support cleats fixed with 12mm galvanized metal bolts/screws. Rafter work to be secured to floor, structural support and
nearest structural member using galvanized metal screws, including groove pattern as per design. Necessary vertical
12 wooden/ply/aluminium members to be extended up to the slab level above false ceiling for support, No extra cost to be given 13.93 SQMT 5200.00
for support above false ceiling. Any provision of services is included in the rates. Only visible area below false ceiling to be
measured in one side front elevation in sqm for mode of payment. The rafter partition shall be executed as per detail
architectural drawing. Rate shall include necessary approved hardware items including all materials and labour etc. complete as
per detail instruction of engineer-in charge and consultant.
Folding partition Sliding folding partition
Providing and fixing in position partitions made out of Aluminium cross section of approved make 2"x1 1/2 " (ISI marked)
framework 2'-0" c/c both ways treated with antitermite solution, covered with 12 mm thk commercial ply wood (approved
make)/ partly glazed with approved shape & shade of finish as per material mentioned below .All provisions to be made for all
electrical, networking boxes onto partition framework at required heights/levels with necessary hardware fittings with
necessary additional supports as directed.
applying primer coat of the paint, Putty shall be applying walls and ceiling for making even surface up to finish level.Providing
and applying even coats of acrylic emulsion paint / on walls and ceiling up to final finish. Shade and texture of the paint shall be
14 as approved by Architect or EIC. Application of paint shall be with brush and last coat of paint shall be applied with a standard 2105.00 SQMT 290.00
company roller all as approved by architect or All rates are inclusive cost of paint , scrapping the surface, putty, primer, brush,
roller, scaffolding cleaning charges etc. complete.
Decorative Exterior at main gate of SPIPA Office TEXTURE PAINT: Providing & applying a coat of textured cement finish on walls
and columns. The rate shall include scrapping, levelling & preparing the surface. Primer coat + (minimum) 3 coats of paint of
approved make, quality & shade. Completed as directed by Project manager / Architect.
Wooden frame covering with Wallpaper or Vinyal Sticker :Providing and supplying wall papers and Vinyal Sticker 2d or 3d as per
Providing and applying synthetic enamel paint of Asian/Nerolac/ICI/Lewis Berger/J&N of approved brand to previously painted
17 steel work with one coat of approved quality and brand paint of Asian, Nerolac, ICI, Berger, Johnson make and of required 1.00 SQMT 390.00
shade, including cleaning and scrapping the surface with sand paper etc. complete as directed.
TENDER FOR CIVIL/INTERIOR/ELECTRICAL/HVAC WORK FOR SARDAR PATEL INSTITUTE PUBLIC ADMINISTRATION (SPIPA), GANDHINAGAR
Sr. No. Description Quantity Unit Rate Amount
Full ht Partition 75mm thick with aluminium framework with 12mm thk mdf exterior grade / 12mm thick hdf finish on both
75mm thick.) Providing and fixing partition frame work using of 50mm x 38mm x 1.5 mm ( as per IS Standards of Jindal or
equivalent make ) thick extruded aluminium box section framework at spacing not exceeding 600mm C/C both ways ( horizontal
and vertical ) framework formed using 50mm x 38mm x 1.5mm thick extruded aluminium box section connected using 50mm X
50mm X 1.5mm thick "L" angle support cleats fixed with 12mm galvanized metal screws. partition framework to be secured to
floor, structural support and nearest structural member using galvanized metal screws and wooden dowels, 12mm thick HDF
18 Sheet ( IS:303 ) grade on both sides, finished approved shade, and groove pattern as per design. necessary vertical aluminium 156.00 SQMT 3800.00
framework members to be extended up to the slab level above false ceiling for support with all electrical, networking boxes
which shall be installed on 25mm x 25mm x 1.2mm thick extruded aluminium "L" angle screwed onto partition framework.
required holes/face plate for conduit pipes of electrical / networking cables and other services provision is included in the rates.
Only visible area below false ceiling to be measured for mode of payment. No extra cost to be given for support above false
ceiling. all complete as per architectural drawing. Rate shall include necessary approved hardware items including all materials
and labour etc. complete as per detail instruction of engineer-in charge and consultant.
Low ht Partition Both side Laminate Finish Partition ( 75mm thick.) Providing and fixing partition frame work using of 50mm x
38mm x 1.5 mm ( as per IS Standards of Jindal or equivalent make ) thick extruded aluminium box section framework at spacing
not exceeding 600mm C/C both ways ( horizontal and vertical ) framework formed using 50mm x 38mm x 1.5mm thick extruded
aluminium box section connected using 50mm X 50mm X 1.5mm thick "L" angle support cleats fixed with 12mm galvanized
metal screws. partition framework to be secured to floor, structural support and nearest structural member using galvanized
metal screws and wooden dowels, 12mm thick commercial plywood ( IS:303 ) grade on both sides, finished with 1.0mm thick
laminate of approved shade, 75mm x 18mm ghana teak wooden patta on low ht partition top / partition side as per site
required and groove pattern as per design. with all electrical, networking boxes which shall be installed on 25mm x 25mm x
1.2mm thick extruded aluminium "L" angle screwed onto partition framework. required holes/face plate for conduit pipes of
electrical / networking cables and other services provision is included in the rates. In case wood is used at any place due to
constraint, it must be finished with duco color or polish matching with laminate. all complete as per architectural drawing. Rate
shall include necessary approved hardware items including all materials and labour etc. complete as per detail instruction of
engineer-in charge and consultant.
Laminate finish wall paneling _with Aluminum frame work Providing & Fixing wall paneling made from 50mm x 25mm x 1.2mm
aluminum framework at 600 mm x 600mm C/C both vertically & horizontally covered with 12mm thick commercial plywood (
20 IS:303 ) grade with 1.0 mm thick laminate of approved make finished with groove pattern and design completed as per drawing 121.00 SQMT 3000.00
and details instruction of engineer-in charge and consultant, as per the sample approved by the Architect.
21 Library Rack With Aluminium Frame And Glass Door 24.00 SQMT 2700.00
22 Library Room Table (750 x 450 ) 9.00 EACH 5500.00
GLASS BOARD Providing & Fixing 6mm thk lacquered glass paneling made from 50mm x 25mm x 1.2mm aluminum framework
at 600 mm x 600mm C/C both vertically & horizontally covered with 6mm thk lacquered glass fixed on 12mm thk commercial
23 plywood ( IS:303 ) grade on Wall Paneling with Consider 2 - 4 mm gap between each glass panels with aluminum "T" section/ 13.00 SQMT 4400.00
Profile section with ply / lighting boxing edge cover in laminate finish to be completed with necessary hardware and accessories
completed as directed by Project manager / Architect.
TENDER FOR CIVIL/INTERIOR/ELECTRICAL/HVAC WORK FOR SARDAR PATEL INSTITUTE PUBLIC ADMINISTRATION (SPIPA), GANDHINAGAR
Sr. No. Description Quantity Unit Rate Amount
Providing and fixing full height glass partition : made out of glazed partition with Slim line Partitions systems of 45 x 25 mm
thick section on all four sides with 10mm thick clear tempered glass, to be butt jointed with 2 to 3 mm edge chamfer & edge
polishing all around. Distance between two butt jointed glass panels not to exceed 4mm. Edges and grooves between glass
24 panels to be filled with as Vertical "I" Section, between Glass to glass joint from FFL up to FCL Level neatly applied all complete 65.00 SQMT 3762.20
as per architectural drawing. Rate shall include necessary approved hardware items including all materials and labour etc.
complete as per detail instruction of engineer-in charge and consultant.45 x 25 mm thick section ( JEB/Alloy make )
SOFT BOARD/ PIN-UP BOARD Providing and fixing 12 mm thk. Pinup board comprising of 12 mm thk. back Ply fixed on wall with
25 15mm thk pinup board (Soft board) covered with fabric of approved co. (Basic rate=Rs.150 per running meter.) with teak wood 18.00 SQMT 1400.00
beading 1" x 1" all around finished melamine polish.
Pelmet for Roller Blinds- 1.0mm thick Laminate Finish
Providing and fixing Pelmet for blinds, made out of 18mm thick ply, exposed edges of the pelmet shall be finished in approved
1.0mm thick Laminate, wooden beading patti on open edge , The pelmet shall be in reversed "U" shape and shall be 200mm
wide and up to the nearest Horizontal Mullion. The rate quoted shall be including fixing the pelmet with wooden/ aluminium/ GI
support @ 1200mm c/c anchor bolted to the structural ceiling etc., complete as per detail drawings.
Frameing - Providing and fixing Door frame made out of 1st quality Ghana teak Wooden frame finished with architrave patti
on wooden frame with melamine polish/ Colour duco paint Finish fitted with hold fast/ fasteners as approved by architect. All
27 door frames shall be treated with Borer/Anti termite treatment all complete as per architectural drawing. Rate shall include 74.00 RMT 1400.00
necessary approved hardware items including all materials and labour etc. complete as per detail instruction of engineer-in
charge and consultant. (Door Frame Size : 75 mm x 50 mm)
Both Side Laminate Finish Solid Flush Door With Door Frmae -Providing & fixing both side laminated min 37mm (+/-2mm) thick
fully solid water proof flush door finished as per design and detail. The edge of the shutter should be surrounded with melamine
polish/ colour duco paint finish 38mm x 12mm thick teak wooden beading or Laminate beading. Rate shall include necessary
approved door locking systems, SS hinges, 600mm brush finish SS Handle pair, heavy duty double cylinder floor springs/ heavy
duty door closer, door stopper, foot operated door opener & miscellaneous hardware items including all materials and labour
etc. And Providing and fixing Door frame made out of 1st quality Ghana teak Wooden frame finished with architrave patti on
wooden frame with melamine polish/ Colour duco paint Finish fitted with hold fast/ fasteners as approved by architect. All
door frames shall be treated with Borer/Anti termite treatment all complete as per architectural drawing. Rate shall include
necessary approved hardware items including all materials and labour etc. complete as per detail instruction of engineer-in
charge and consultant. completed as per drawing and details and instruction of engineer-in charge and consultants and as per
sample approved by the Architect.
FULLY GLAZED GLASS DOOR with aluminum frame (JEB/ Alloy/ Kubik)- Providing and fixing glass door made out of 12mm thick
toughened glass with Slim line Door systems of 45 x 25 mm thick aluminum section frame on top and sides, including patch
fittings, Pivot Hinges System, locking systems, 600 mm S.S. brush finish Handle pair, double cylinder floor spring ( Heavy duty),
29 gaskets & foot operated door opener, Including all materials and labour, with necessary hardware as per drawing and details 18.00 SQMT 7000.00
complete as per drawing and details and instruction of engineer-in charge and consultant and as per sample approved by the
Architect. ( Size of each door shall be as per measurement in drawing. )
TENDER FOR CIVIL/INTERIOR/ELECTRICAL/HVAC WORK FOR SARDAR PATEL INSTITUTE PUBLIC ADMINISTRATION (SPIPA), GANDHINAGAR
Sr. No. Description Quantity Unit Rate Amount
Providing and fixing Roller Blind fixed on window level on wooden batten and curtain lift with cotton thin rope, design and
30 colour as per instruction by engineer – in – Charge with necessary hardware fitting, material and labour etc. complete as per 116.00 SQMT 1600.00
detail drawing and instruction of engineer-in charge and consultant.
SS plate Signage: 450mm X 100mm - Stainless Steel satin finished flat etching plate of 1.5mm thick. Providing Making and fixing
of various in-door signage, as & where basis. sign in ISI Brushed S.S. Grade 304 letters in English letter + All text and design in
acid process, each plates. Each text & design with respective color coated complete plate. The SS mounted on glass or any non
31 holes surfaced by 3M double sided tape with required chemical process, guidelines by 3M company. Whereas, Any other then 30.00 EACH 1200.00
glass surface, SS plate mounted by Two side screws with required grips nd holes on the wall with two SS spacer screws. The item
should be as per instruction at site approved by Architect of Engineer in charge. The rate shall be inclusive of scaffolding, drilling,
adhesive material etc. at all height.
Letters for SARDAR PATEL INSTITIUTE PUBLIC ADMINISTRATION & Address Main Entry Side Wall 7" Height Font + 18" X 18"
LOGO (SS FINISH)
Spipa LOGO Providing and fixing 6mm thick lacquered glass with printed logo as per Design / Client’s Requirement including
necessary support of 12mm ply with framing and back treatment, fixing of glass with 3Mtape/ silicon and levelling complete.
33 The glass edges shall be polished/ fitted with aluminium profile, all respect as per details completed as per drawing and details 3.00 EACH 7500.00
instruction of engineer-in charge and consultant, as per the sample approved by the Architect. ( Size : 1200mm x 1200mm )
supplying & fixing 3m sparkel film on glass with manufacturer specification, as per the detailed technical specifications,
drawings and as per the instructions of Engineer- in- charge.
35 Providing and Fixing Doormat (6' X 2') made up of synthetic material as per the approval from the Architect / EIC. 2.00 Each 1200.00
Providig & Fixing Wall Clock as per approved make. As per instruction at site approved by Architect of Engineer in charge.
Providing, supplying SS 304 perforated Dustbin as per approved make. As per instruction at site approved by Architect of
Engineer in charge.
Providing, supplying Water Dispenser as per approved make. As per instruction at site approved by Architect of Engineer in
CEO TABLE - Providing and fixing in place, Directore table of (Size - 3000mm X 1050mm X 750mm ht). The Table shall have
made in 18mm thick Commercial Plywood 303 grade and finished in 4.0mm Veneer Finish of approved shade including top
Mono coat polish finish. The storage units shall have intermediate Support/shelves made in 18mm thick Commercial Plywood
303 grade and internal surface 1.0mm the laminate finish with matching wood lipping with table top on 4.0mm veneer finish +
6mm thk Corian finish. The Table shall have matching wood edge moulding as per the detail drawings. This also includes
providing necessary hardware etc. of approved make. All exposed wooden surfaces mono coat polished. Cost to include
Borer/Anti termite treatment for wood/plywood completed as directed by Project manager / Architect.
CEO Side storage units - Providing and fixing 900mm deep Low height storage unit (Upto 750 mm high) made of 19mm thick
plywood and finished with 1.0mm thick laminate externally and internally. Openable shutter made of 19mm thick plywood to be
provided finished with 1.0mm thick laminate internally and externally. Intermediate shelves made of 19mm thick plywood to
provided (as per size of box file/office file) finished with 1 mm laminate. The exposed edges of the shelves should have post
form edges All complete including necessary hardware, heavy duty hinges, handles, locks etc.
TENDER FOR CIVIL/INTERIOR/ELECTRICAL/HVAC WORK FOR SARDAR PATEL INSTITUTE PUBLIC ADMINISTRATION (SPIPA), GANDHINAGAR
Sr. No. Description Quantity Unit Rate Amount
CEO Back storage units - Providing and fixing 450 mm deep Low height storage unit (Upto 750 mm high) made of 19mm thick
plywood and finished with 1.0mm thick laminate externally and internally. Openable shutter made of 19mm thick plywood to be
provided finished with 1.0mm thick laminate internally and externally. Intermediate shelves made of 19mm thick plywood to
provided (as per size of box file/office file) finished with 1 mm laminate. The exposed edges of the shelves should have post
form edges All complete including necessary hardware, heavy duty hinges, handles, locks etc.
Class 2 Cabin Table Size : 2000 X 900 X 750 MM 25mm thick table top made of medium 18mm thk plywood board with
42 Laminate finish. All complete including all the external surfaces to be finished with 1.0mm thick laminate and internal surfaces 2.00 EACH 18000.00
to be finished with 0.8 mm thick laminate of approved shade
Side storage units - Providing and fixing 450 mm deep Low height storage unit (Upto 750 mm high) made of 19mm thick
plywood and finished with 1.0mm thick laminate externally and internally. Openable shutter made of 19mm thick plywood to be
provided finished with 1.0mm thick laminate internally and externally. Intermediate shelves made of 19mm thick plywood to
provided (as per size of box file/office file) finished with 1 mm laminate. The exposed edges of the shelves should have post
form edges All complete including necessary hardware, heavy duty hinges, handles, locks etc.
Back storage units - Providing and fixing 450 mm deep Low height storage unit (Upto 750 mm high) made of 19mm thick
plywood and finished with 1.0mm thick laminate externally and internally. Openable shutter made of 19mm thick plywood to be
provided finished with 1.0mm thick laminate internally and externally. Intermediate shelves made of 19mm thick plywood to
provided (as per size of box file/office file) finished with 1 mm laminate. The exposed edges of the shelves should have post
form edges All complete including necessary hardware, heavy duty hinges, handles, locks etc.
Cubical Table 1350mm X 750 mm X 750mm with Side combo storage 900mm X 450mm X 750mm HT Cubical
Table with side combo storage- Providing & fixing table as described below: Work top to be made out of 25mm particle board
finish with pre laminate of approved shade and make with bottom finished with backer laminate. All edges shall be provided
with machine pressed 2mmthick PVC edge band. The work surface shall be provided with 450mm Aluminum powder coated
access flap and with cable dump below top. There shall be CRCA made power pole to carry wires from floor to access flap. Metal
Powder coated leg of 50X50mm cross section and of 2mm thickness. Powder coating should be of 60-80 Microns. Front
Modesty- Metal perforated modesty mounted with brackets, it should have 260mm gap from the floor level.
Side combo storage of size 900X450X750mm HT shall be made up of 18 mm thick prelaminated particle board with three
drawers and openable shutters as per drawings. All edges to be finished with PVC edge band . Rate is inclusive of provision of
key lock, locking strip and multi – drawer lock, brackets for box-file pedestals. Rate is inclusive of metabox channels/ telescopic
channel of ebco make or equivalent for supporting drawer. Rate is inclusive of Keyboard tray of Inoffit make . CPU trolley M.S.
Powder coated with castors complete as per detailed technical specifications and drawing.
Full Height Low ht Storage : 18mm prelaminated partical board top/bottom board & back side 9mm thk.all side pvc edge band
with internal shelves with support to take care of file weight including handle & hardware complete.
TENDER FOR CIVIL/INTERIOR/ELECTRICAL/HVAC WORK FOR SARDAR PATEL INSTITUTE PUBLIC ADMINISTRATION (SPIPA), GANDHINAGAR
Sr. No. Description Quantity Unit Rate Amount
Customer care Size : 1200mm X 750 mm X 750mm Customer care Table- Providing & fixing table as described below: Work top
to be made out of 25mm particle board finish with pre laminate of approved shade and make with bottom finished with backer
laminate. All edges shall be provided with machine pressed 2mmthick PVC edge band. The work surface shall be provided with
60mm dia grommet hole and with cable raceway below top. There shall be CRCA made electrical panel in intermediate legs for
wire carrying. Metal Powder coated leg of 50mm X 50mm cross section and of 2mm thickness. Powder coating should be of 60-
80 Microns. Front Modesty- Metal perforated modesty mounted with brackets, it should have 50mm gap from the floor level.
Rate is inclusive of Keyboard tray of Inoffit make .CPU trolley M.S. Powder coated with castors complete as per detailed
technical specifications and drawing.
48 Over Head Storage 600 X 450 X 400 (WORK STATION AREA) 11.00 SQMT 7200.00
Meeting Table Size : 2100mm X1050mm X 745mm HT
Conference table- Providing & fixing table as described below: Work top shall be made of 25mm thick prelaminated particle
board with 2mm PVC edge band of approved shade and design. All edges shall be provided with machine pressed 2mm thick
PVC edge band. The top to be provided with 450mm pop up boxes as per approval for providing electrical switch socket, Lan
points, video conferencing cable outlets etc. Table top should be supported on 50mm X 50mm open metal powder coated legs
as per detailed technical specifications and drawing.
Green Wall Cladding Supply of Vertical garden Green Modules or Bio wall of poly propylene make(SIZE- 1'6" X 6") and
establishment of Irrigation system with filter and fertigation unit. Supply of suitable nursery established healthy plants in light
weight(Perlite - 20% , peat - 40%, sand - 10% , Organic Compost - 10% , and mini qty of sweet earth - 10%) planting media in
proper proportions depending on the plants species. Establishment of Plants in nursery for about 45 days to make sure the
plants are well established and bushy by providing proper environment, plant food and growth boosters, Commissioning of bio
50 wall to the Aluminium frame structure ( 2" x 1" Box vertical frame and 2" x 1"L angle mounted on verticals with bolt and nut 9.00 SQMT 6500.00
system ) and placing the plants in approved patterns as per the design.Cost to include 50mm thick 300mm deep Portal Finished
with Veneer finish with monocoat polish finish with 12mm marine ply, with Required Aluminium Frame work , including SS
drain tray in plantation bottom level as per the dwg and instructions of the Architect.
Mode of Measurement : Green Wall area will be measured for payment.
Providing and Supplying Plantation with Fibre glass pots / SS pots ( Plantation Basic Cost Rs 4000/- ) completed as per drawing
51 and details instruction of engineer-in charge and consultant, as per the sample approved by the Architect. 20.00 EACH 2000.00
52 Accoustical Work (Training Room & Class Room) 45.00 SQMT 2800.00
TENDER FOR CIVIL/INTERIOR/ELECTRICAL/HVAC WORK FOR SARDAR PATEL INSTITUTE PUBLIC ADMINISTRATION (SPIPA), GANDHINAGAR
Sr. No. Description Quantity Unit Rate Amount
Carpet Flooring _Bike path collection _office aera
Scope - Work shall include the furnishing of all materials, equipment and labour to install the complete Carpet system with the
manufacturer's approved adhesive. It is the Vendor's / supplier's responsibility to ensure that materials delivered on site is on
the decided date by the project team & it is safeguarded from the time of his purchase until he hands over the finished flooring.
It is desirable to store materials in a pred-decided flat, clean and dry surface.Carpet floor shall be installed by a thoroughly
experienced vendor and the type of installation shall be as per manufacturer's specifications. The Vendor shall inspect the
premises prior to commencement of work and verify that the building is ready for installation.Carpets to be laid as per the
pattern indicated on drawing. All wastages, octroi ,freight & handling to be accounted for and no additional amount shall be
paid for the same. Rate to be inclusive of covering of carpet with 50 micron double plastic cover & sealing of joints with tape.
53 Any pencil marks etc., shall be removed using ordinary pencil eraser. All damaged portions to be replaced free of cost.Providing 18.00 SQMT 1680.00
and laying of Carpet Tile over the specified area with following specification. The floor which receives the carpet to be
thoroughly cleaned as per manufacturer's specification. The carpet is to be laid over a bed of manufacturer's approved adhesive
spread evenly over the entire floor. The rate shall include cutting, trimming, fixing and clearing away of residual material to a
location as directed. The rate shall also include supplying and laying of a protective layer of PVC or HDPE sheet of 50 microns
thickness Double Layer, held together with scotch tape. The laid carpet to be vacuumed after the removal of protective cover/on
commissioning. If after the protective layer is removed and stains observed in the carpet because of in adequate protection, the
same shall be shampooed and made good to the satisfaction of the project managers. The measurements of carpet will be the
actual laid area.
Wooden Flooring Supplying, fitting and fixing 8 mm thick Laminated wooden Flooring ( AC-4 Grade ) Work conforming to
EN13329:2006 with plank size not Iess than 1200mmX 190 mm (with unilin/tongue-groove locking arrangement) having 0.2mm
thick top abrasive layer over a decorative layer followed by a High-density fibreboard (HDF) having density > 940 kg/m3
substrate core over a resin saturated backing layer and installing through unilin or tongue- groove system (having locking
strength not less than 1000 kg/m) over a 2 mm thick underlayer polyurethane foam on polythene sheet 250 micron, over a
smooth, flat, hard subfloor free from moisture (< 8%), grease etc. complete in all respect with requisite accessories like end
profile, transition profile, reducer 'T' profile etc. wherever required and preparation of existing flooring surface POP levelling
base including as per site location with all other incidental works as per direction & satisfaction of Engineer in charge. Cost of
Laminate Floor Accessories only ( Skirting, End edge, Tmoulding, Reducer ) shall have to be added separately, wherever
required. The rate shall include labour, material, maintenance up to handover, cleaning etc. complete. The surface shall be
scratch free at the time of handover. All works shall be done as per architect's specifications and instructions.
TENDER FOR CIVIL/INTERIOR/ELECTRICAL/HVAC WORK FOR SARDAR PATEL INSTITUTE PUBLIC ADMINISTRATION (SPIPA), GANDHINAGAR
Sr. No. Description Quantity Unit Rate Amount
Supplying and installating Linear Workstation: 900*600*750mm. Table top :
Worktop shall be made of 25MM thick Pre- Laminated Particle Board from wood / Certified Low emitting board
conforming to IS:12823. The top shall be laminated with laminate of 0.8 to 1 mm thickness of approved shade as per
IS:2046-1995. All the edges of work surface shall be provided with machine pressed 2 mm thick PVC lipping glued with low
emitting hot melt EVA glue and configuration of access flap. Edges should have option of reverese chamfer edge, shark nose,
duck nose or waterfall edge
Leg : Metal Powder Coated 100 Degree Inclined Knock Down leg with dual tone shades, Leg should be 30X60X2mm thick ERW
pipe to form welded structure , assembled with 4 table support bracket with powder coated finish. NO Welded joint or
hardware should be visible. It should be in Knock down assembly. Partwise (Dual tone) color combination of leg should be there.
Front modesty: Metal square perforated made of minumum 0.8mm CRCA of 300mm Height.
Privacy Panel: 18mm thk. Frameless Fabric Magenetic panel 305mm ht. (finished 1050mm ht) or 30mm thick Framed Soft pinup
Fabric with aluminium trims as per choice. / Both Side 8mm thick Laminated Glass of 1050mm x 350H on brackets considered.
(Brackets in Anodized finish only)
Electrical : 450mm Aluminium Access flap on worktop with soft close, wiring through electrical panel. Access flaps are made up
of aluminium and are used for full length of the worktop . Cable beam should be made of CRCA and should have data and power
seperator where switch plate can be fixed at any position along the length.
With Glass Deivider For Privancy
56 Dining Room Wooden Table With Granite Top (1200mm x 750mm) 11.00 EACH 8500.00
57 Dining Room Wooden Table With Granite Top (1200mm x 450mm) 5.00 EACH 5500.00
MB chair Providing and placing Medium back chair with Mesh back , KneeTilt Mechanism, Fixed Silver Epoxy Armrest , Gaslift
58 for Seat height adjustment , Standard 5-prong Nylon Base, With Fabric Including necessary hardware completed as per 67.00 EACH 9200.00
approved design, make and Architect's instructions. ( Basic rate Rs 9800/- per no)
HB chair Providing and placing High back chair with Mesh back , KneeTilt Mechanism, Fixed Silver Epoxy Armrest , Gaslift for
59 Seat height adjustment , Standard 5-prong Nylon Base, With Fabric Including necessary hardware completed as per approved 11.00 EACH 14000.00
design, make and Architect's instructions. ( Basic rate Rs 14000/- per no)
Providing and placing dining bar counter chair & Library chair of approved design and make and colour. (Basic rate Rs.2155/- per
61 Chair With Pad 50.00 EACH 2800.00
Sofa (Three Seater)- Providing & Supplying sofa seat made out of 2"X2" ply wood framing with 4" Thk. Foam for seat & 3" foam
back covered with fully up holster.
Sofa (Two Seater) - Providing & Supplying sofa seat made out of 2"X2" ply wood framing with 4" Thk. Foam for seat & 3" foam
back covered with fully up holster.
Sofa (One Seater) - Providing & Supplying sofa seat made out of 2"X2" ply wood framing with 4" Thk. Foam for seat & 3" foam
back covered with fully up holster.
SIDE Table Corner table made up of 18 mm thick wooden (PLB) with PVC lipping on all edges with 12mm toughened glass fixed
with SS studs, SS Finish Stand complete as per drawings and details. Size 600 x 600 x 450mm height
Nestle Coffee Machine - Amigo 13+ Beverage Options
From a classic Tapri Coffee to a strong Cappuccino, from an Anna Style Kaapi to a refreshing Masala Chai or a comforting Hot
Chocolate – offer your customers and employees a wide range of refreshing experiences with this bean-to-cup machine
TENDER FOR CIVIL/INTERIOR/ELECTRICAL/HVAC WORK FOR SARDAR PATEL INSTITUTE PUBLIC ADMINISTRATION (SPIPA), GANDHINAGAR
Sr. No. Description Quantity Unit Rate Amount
LG 185 L 5 Star Inverter Direct-Cool Single Door Refrigerator Appliance (GL-D201ABCU, Blue Charm, Base stand with drawer)
68 Kelvinator 95 Litres 1 Star Single Door Refrigerator (Silver Grey, KRC-A110SGP) 1.00 EACH 10000.00
KENT Supreme Copper RO Water Purifier| 4 Years Free Service | Multiple Purification Process | RO + UV + UF + Copper + TDS
Control + UV LED Tank | 8L Tank | 20 LPH Flow | Zero Water Wastage
MAIN LT PANEL Supply, installation, testing and commissioning of factory made, CPRI type tested, indoor cubical compartmental
type MAIN LT PANEL of suitable size, conforming to IEC 61439-1 & 2 and IEC 61641, having both sides openable with hinged
double doors and locking arrangement, IP 43 protection made out of 2.0 mm thick mild steel CRCA sheet, supported and fixed
on structural frame of angle iron of suitable size, including earthing stud, labelling, painting to all internal & external exposed
steel surfaces with powder coating paint (7 tank process), duly fixed in ground with Required Stand / PCC foundation (1:2:4)
type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enamelled (white) with letters, figures and conventional
skull and bones in signal red colour suitable for 3- Phase, 4 Wire system, 500 V grade with necessary wiring, PVC sheathed
stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete all as specified and
directed by engineer-in-charge.The Main LT Panel shall comprise of the following:
[A] BUSBAR CHAMBER
[i] 01 Set (3L + N) of Alu busbar of rated capacity 160 A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc.
with complete connection. (1sq mm - 1Amp)
[i] 160 A, 415 V, Ics = 100% Icu = Icw (1 sec) = 25 kA, 50 Hz FP MCCB, conforming to IS/IEC 60947-2 & 3, having fully rated
neutral with inbuilt protection, providing overload, short-circuit, instantaneous & earth-fault protection
[ii] Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interupts- 01 Nos.
[iii] LED phase indicators (Red, Yellow, Blue)- 01 Set [iV] Surge
Protection Device ( Type 1+2 ) Asco or eq.[B] OUTGOING
[i] 63 Amp FP MCCB - 2 Nos ( UPS, SPARE )
[ii] 63 Amp FP MCB 03 Nos ( AC DB, PDB, SPARE ) [iii] 63 Amp FP
MCB 01 Nos (Spare) [iv] 40 Amp FP MCB 01 Nos (LDB1)
[v] 25 Amp DP MCB 01 Nos ( With Timer & Contector ) [vi]25 Amp DP M[D] 25 KVAR
Supply, installation, testing and commissioning of 160Amp FP mccb 25 ka Microprossesor base inbuilt ELR with IP 65 Double
door type MS Encloser with Required Accessories etc.
MEDIUM VOLTAGE CABLES Supply, Laying, testing & Commissioning of XLPE insulated, medium voltage FRLSH Armoured /
Unarmoured Copper/Aluminium cables as per the specifications, drawings & instruction of Engineer-in-charge and as per the
instruction of the manufacturer. The cable shall be laid with saddaling in open manner on wall/slab from Main MCCB to Main
72 Panel / Main Panel to Distribution board / distribution board to distribution board. The unit rate shall include supply & laying of 70.00 Mtr 600.00
cables,Transportation,Excavation & Back filling from site store to place of installtion,unpacking the drum and return of drum to
the site store. 120 sq mm x 3.5 C Alu Arm cable (MAIN MCCB TO PANEL)
73 16 sq mm x 4C Cu Arm cable (MAIN Panel TO UPS I/P & ACDB) 30.00 Mtr 850.00
74 10 sq mm x 4C Cu Arm cable ( PANEL TO PDB ) 30.00 Mtr 600.00
75 16 sq mm x 4C Alu Arm cable ( PANEL TO LDB) 30.00 Mtr 180.00
76 6 sq mm x 4C Cu Arm cable ( PANEL TO LDB) 35.00 Mtr 270.00
77 4 sq mm x 4C Cu Arm cable ( UPS O/P TO ELDB, SERVER DB, SIGN BOARD ) 55.00 Mtr 250.00
78 16 sq mm single core wire ( UPS I/p & O/p ) 40.00 Mtr 300.00
TENDER FOR CIVIL/INTERIOR/ELECTRICAL/HVAC WORK FOR SARDAR PATEL INSTITUTE PUBLIC ADMINISTRATION (SPIPA), GANDHINAGAR
Sr. No. Description Quantity Unit Rate Amount
CABLE CONNECTIONS & TERMINATIONS SITC of Connections & Termination of Medium voltage XLPE insulated
alluminium/copper cables as per the specification & instruction of Engineer-in-charge.The unit rate shall include connection of
adequate size Double compression type brass cable glands and lugs including cutting/stripping of cable insulation, fixing of cable
glands,crimping the lugs, connection of cable armour with earth bar,necessary tools,Rubber Hoods, Gland
Earthing,hardware,PVC insulated tape and all other material required. 95 sq mm x 3.5 C Alu Arm cable (MAIN MCCB TO
80 16 sq mm x 4C Cu Arm cable (MAIN Panel TO UPS I/P & ACDB) 4.00 Nos. 1100.00
81 10 sq mm x 4C Cu Arm cable ( PANEL TO PDB ) 2.00 Nos. 850.00
82 16 sq mm x 4C Alu Arm cable ( PANEL TO LDB) 2.00 Nos. 850.00
83 6 sq mm x 4C Cu Arm cable ( PANEL TO LDB) 2.00 Nos. 650.00
84 4 sq mm x 4C Cu Arm cable ( UPS O/P TO ELDB, SERVER DB, SIGN BOARD ) 8.00 Nos. 450.00
85 16 sq mm single core wire ( UPS I/p & O/p ) 16.00 Nos. 60.00
LIGHTING & POWER ,UPS, AC,EMERGENCY DISTRIBUTION BOARDS Supply, installation, testing & commissioning of Three
Phase/ Single Phase, Double Door, readymade type Distribution Boards IP 43 grade, with PPI kit and Flexy Distribution board &
SPN as per drawings & specifications. The unit rate shall include supply & fixing on wall / column or concealed in wall, checking
of wiring, connection and operation of MCBs and supply of necessary hardware. LIGHTING DB- 8 WAY TPN -- 40 Amp FP MCB As
Incommer & Per Phase 40Amp DP ELCB 30ma & 6 Nos 6 to 25Amp SP MCB as Outgoing.
AC DB- 12 WAY TPN -- 63 Amp FP MCB As Incommer & Per Phase 63Amp DP ELCB 30ma & 10 Nos 6 to 25Amp SP
MCB as Outgoing.
UPS DB- 8 WAY TPN -- 63 Amp FP MCB As Incommer & Per Phase 63Amp DP ELCB 100ma & 06 Nos 6 to 25Amp
SP MCB as Outgoing.
POWER - DB- 8 WAY TPN -- 63 Amp FP MCB As Incommer & Per Phase 63Amp DP ELCB 100ma & 06 Nos 6 to
25Amp SP MCB as Outgoing.
EMERGENCY LIGHTING DB- 8 WAY SPN -- 25 Amp DP ELCB 30 ma As Incommer & 6 Nos 6 to 25Amp SP MCB as
Server DB- 6 WAY SPN -- 25 Amp DP ELCB 100 ma As Incommer & 4 Nos 6 to 25Amp SP MCB as Outgoing.
92 UPS i/p & o/p - MCCB -- 63 Amp FP MCB With Metal Encloser. 2.00 Nos. 3500.00
93 25 Amp DP Mcb with 3 pin Industrial Plug Socket Board Supply & Fixing. ( For Split AC ) 18.00 Nos. 1950.00
94 32 to 63 Amp FP RCBO 300ma With outdoor waterproof Encloser & MS Suppot Supply & Fixing. 2.00 Nos. 2200.00
EARTHING 50 mm outer Dia pipe and 25mm inner dia pipe type 3 meter Long GI Chamical Earthing with Chamical Bag Supply &
Fixing. Approved by Cunsultant
96 25 mm x 6 mm GI Earthing Strip Supply & Laying. 140.00 Mtr 110.00
97 6 sq mm cu flexible cable Supply & Laying. 160.00 Mtr 60.00
98 10 sq mm cu flexible cable Supply & Laying. 109.00 Mtr 150.00
FLOORING RACEWAY & CABLE TRAY Supply & installation of readymade Hotdip G.I./ Powder Coated Flooring Raceway &
99 Junction Box, specification & instruction of Engineer-in-charge including all materials & hardware.. 100 mm x 38 mm x 1.6 mm 110.00 Rmt 420.00
thick 2 Compartment flooring raceway
100 300 mm x 38 mm x 1.6 mm thick 3 compartment flooring raceway 70.00 Rmt 700.00
101 350mm x 350 mm Floor Junction Box With SS Junction Plate. 20.00 Nos. 700.00
102 150mm x 150 mm Floor Junction Box With SS Junction Plate. 20.00 Nos. 700.00
TENDER FOR CIVIL/INTERIOR/ELECTRICAL/HVAC WORK FOR SARDAR PATEL INSTITUTE PUBLIC ADMINISTRATION (SPIPA), GANDHINAGAR
Sr. No. Description Quantity Unit Rate Amount
Cable Tray Perforated Type Supply and fixing of perforated type Hotdip GI / Powder coated cable trays of the following sizes
103 with Including all accessories like Horizontal / Vertical Bend, T Junction, Hanging 10MM Threded Road, C Channel, 10MM 15.00 Rmt 700.00
Farshners, 10MM Nut Bolts and all accessories etc… 250 mm Wide (250 mm x 50 mm x 2 mm thick)
104 100 mm Wide ( 100 mm x 50 mm x 2 mm thick ) 15.00 Rmt 600.00
INTERNAL WIRING Wiring for Light/ Bell Point with 2-1.5 sq.mm & earth wire of 1.5 sq.mm (Green) both are of ISI marked
approved make 1.1 KV grade FRLS PVC insulated multistage copper wires, in following type of approved make pipe/cassing to
be erected concealed in/ on surface on wall/ceiling complete with approved make 6A Modular type switch / bell push &
105 accessories and earth continuity of following type, erected on PVC / Metallic box, single mounting base frame covered with 88.00 Nos. 550.00
textured/metallic front plate modules erected on / in wall / ceiling as per pipe erected, with necessary Lamp holder/ceiling rose
/ H.D. Connector as directed. (a) with Rigid PVC pipe/ Casing Carping and accessories
Wiring for Looped Light with 2-1.5 sq.mm & earth wire of 1.5 sq.mm (Green) both are of ISI marked approved make 1.1 KV
grade FRLS PVC insulated multistrand copper wires, in following type of approved make pipe/ Casing Capping to be erected
concealed in/ on surface on wall/ceiling complete, with necessary Lamp holder/ceiling rose / H.D. Connector as directed.
Wiring for Fan / Exahust Fan Fan Point with 2-1.5 sq.mm & earth wire of 1.5 sq.mm (Green) both are of ISI marked approved
make 1.1 KV grade FRLS PVC insulated multistage copper wires, in following type of approved make pipe/cassing to be erected
concealed in/ on surface on wall/ceiling complete with approved make 6A Modular type switch / Regulater & accessories and
107 earth continuity of following type, erected on PVC / Metallic box, mounting base frame covered with textured/metallic front 45.00 Nos. 750.00
plate modules erected on / in wall / ceiling as per pipe erected, with necessary Lamp holder/ceiling rose / H.D. Connector as
directed. ( Exahust / wall Fan Point Require 6 Amp Socket & Switch) (a) with medium class Rigid PVC pipe/ Casing Carping and
on Board 6A, 5 pin socket controlled by 6A switch - single phase - to be wired using 2 X 2.5mmsq. + 1 X 1.5 mmsq. FRLS Copper
wire in 25 mm dia FRLS PVC conduit.(wiring shall be measured separately). (ONB )
6A, 5 pin socket controlled by 6A switch - single phase - to be wired using 2 X 2.5mmsq. + 1 X 1.5 mmsq. FRLS Copper wire in
mm dia FRLS PVC conduit.(wiring shall be measured separately).
6/16A, 5 pin socket controlled by 6A switch - single phase - to be wired using 2 X 2.5mmsq. + 1 X 1.5 mmsq. FRLS Copper wire in
25 mm dia FRLS PVC conduit.(wiring shall be measured separately).
6/16A, 5 pin socket controlled by 20A Moduler SP MCB - single phase - to be wired using 2 X 4mmsq. + 1 X 2.5 mmsq. FRLS
Copper wire in 25 mm dia FRLS PVC conduit.(wiring shall be measured separately).
3 Nos 6A, 5 pin socket controlled by 16A switch - single phase - to be wired using 2 X 2.5mmsq. + 1 X 1.5 mmsq. FRLS Copper
wire in 25 mm dia FRLS PVC conduit.(wiring shall be measured separately).( UPS POWER BOARD )
1 Nos 6A, 5 pin socket controlled by 6A switch - single phase - to be wired using 2 X 2.5mmsq. + 1 X 1.5 mmsq. FRLS Copper wire
in 25 mm dia FRLS PVC conduit.(wiring shall be measured separately).( UPS POWER BOARD )
1 Nos 16A, 5 pin socket controlled by 16A switch - single phase - to be wired using 2 X 2.5mmsq. + 1 X 1.5 mmsq. FRLS Copper
wire in 25 mm dia FRLS PVC conduit.(wiring shall be measured separately).( RAW POWER BOARD)
Design, Supply, Installation Testing & Commisioning of Touch Pad Display , Remote operated With 4 Module Switch Operation
Module With Face plate, Remote & Back Box Supply & Fixing.
TENDER FOR CIVIL/INTERIOR/ELECTRICAL/HVAC WORK FOR SARDAR PATEL INSTITUTE PUBLIC ADMINISTRATION (SPIPA), GANDHINAGAR
Sr. No. Description Quantity Unit Rate Amount
MAINS WIRING Wiring of submains / circuit mains in concealed / surface conduit system using ISI marked 25mm dia FRLS PVC
conduit of 2 mm thick with all accessories complete. 1100 V PVC insulated FRLS copper flexible wires for phase , neutral and
earth with conduit and wiring accessories ,etc. complete for lighting / power points Rate shall include cost towards junction
boxes / wire pull boxes to be located near junctions / beam crossings for easy drawing of wires. The rate shall include the
chasing of walls/ floors and plastering the chased portion as required to complete 2 x 1.5 sq.mm + 1 x 1.5 sqmm. Copper wires
with 25 mm dia FRLS conduit.
117 2 x 2.5 sq.mm + 1 x 1.5 sqmm. Copper wires with 25 mm dia FRLS conduit. 1650.00 Rmt 65.00
118 2 x 4 sq.mm + 1 x 2.5 sqmm. Copper wires with 25 mm dia FRLS conduit. 720.00 Rmt 125.00
LIGHT FIXTURE Supply, Installation, testing & commissioning of Light fixture & ceiling Fan in False Ceiling or on wall or bellow
slab, Exhaust fan as per Drawing & as per instruction of engineer-in-charge. All fixtures to be considered with required size of
drivers & Required Hardware etc. 1x 36 W Recessed type LED light fixture with required accessories & necessary arrangement as
per instruction of Engineer in charge *( Size : 600 x600 )
120 17.2 mm LED Profile Light With Requiredd Driver etc. 10.00 Feet 450.00
121 18W LED down lighter Open/ conceled. 75.00 Nos 1180.00
122 36W LED Linear Hanging light with Required Jointer, Elbow & accessories etc. 8.00 Nos 4250.00
123 10W 2' long LED Mirror Light - Phillips make. 8.00 Nos 350.00
124 6W LED Spot COB Light Surface / Recess Supply & Fixing. 6.00 Nos 800.00
125 20W LED Batten light Fixtures Supply & Fixing. 10.00 Nos 350.00
126 2x6W LED Spot COB Light Recess Supply & Fixing. 8.00 Nos 2650.00
Supply Intsallation testing & Commisioning of 1200 MM 50W Five Star ratting Ceiling Fan with Fan Road plate & Rubber Clamp
128 Supply Intsallation testing & Commisioning of 450 MM Wall Mounted Fan. 2.00 Nos 2450.00
129 Supply Intsallation testing & Commisioning of 200MM PVC Boady Ex-Fan . 6.00 Nos 1450.00
CONDUITS Supply, laying of conduit open or concealed manner in Slab / floor / wall as per drawings, specification, instruction
130 of Engineer-in-charge and as per the instruction of the manufacturer. Rate of PVC pipe, flexible pipe, junction box and all other 150.00 Rmt 80.00
acessories to be considered in unit rate. 32 mm dia. PVC conduit
131 25 mm dia. PVC conduit 250.00 Rmt 45.00
132 100X50 mm PVC Raceways white 30.00 Rmt 650.00
133 50X50 mm PVC Raceways white 30.00 Rmt 350.00
UPS SYSTEM Supply installation testing & Commisoning of 10 KVA Online Ups System 3 Phase input & 3 Phase Output With
134 Min Battery Backup With Required Battery Rack, Battery Connecting Cables, Lugs, Parallel kit , Busbar box etc as Per Required 1.00 Nos 300000.00
Engineer incharge.
Networking Supply, Laying of Cat 6 UTP computer wire with conduit for data & voice. The tagging has to be printed (and should
not be handwritten) every 5 mtrs.
INFORMATION OUTLETS - Supply, Installation testing and commissioning of RJ 45 jack type socket with box and plate complete.
The cover plate shall match with the other wiring accessories. (For data)
Supply, Installation testing and commissioning of RJ 11 jack type socket with box and plate complete. The cover plate shall
match with the other wiring accessories. (For telephone)
SITC of Cat6 24 port Patch panel rack mount with lable & quick mounting for Data (Black Colour). The tagging has to be printed
(and should not be handwritten) for Data
SITC of Cat6 Patch Cord for patching at User Desk 1-Mtr. RJ-45 to RJ-45. This should be factory crimped and guaranteed
performance with report
TENDER FOR CIVIL/INTERIOR/ELECTRICAL/HVAC WORK FOR SARDAR PATEL INSTITUTE PUBLIC ADMINISTRATION (SPIPA), GANDHINAGAR
Sr. No. Description Quantity Unit Rate Amount
140 SITC of Cat6 Patch Cord for patching at User Desk 2- Mtr. RJ-45 to RJ-45 100.00 nos 200.00
SITC of 24U Wall Mount Rack for Mounting devices with all required accessories. There should be 15amp multiplug points
power strips in each rack installed on both sides in the rear side of the rack, This should have 2 fans exhaust on the top, with
141 metal perforated door on both side; teh rear side door should be double door. This should also have adequate cable managers 1.00 nos 24500.00
alognwith tagging on jack panels itself. The tagging has to be printed (and should not be handwritten) with rack installation &
dressing ( Incl. Equipment Tray, PDU (Power strip) as per Requirement.
50 Pair Telephone Krone Box With Krone Strip With Termination & Required Material Supply & Installation & Testing etc.
143 Supply & Laying 50 Pair Jelly Arm Cable 75.00 Mtr 650.00
Supply, Installation, Testing and Commissioning of 8M Popup Box With 1Nos 6A Switch Socket, 1 Nos Data Point, 1 Nos Tele
Point, 1 Nos HDMI Socket,
Supply, Installation, Testing & Commissioning of of 19" Rack Moutable hot standby communication server with standard
mounting hardware & should be 100% Non-Blocking system as per tender specification features
- 47 Analog Extensions Ports
- Expandable up to 80 Ports
- 5 Ports for analog devices i.e. Fax , modem. etc
- 5 ports required for IP phones
- 48V DC adaptor for IP phones
- 1 ISDN PRI bidirectional lines
- CDR Interface
- IN built Voice mail
- Music on Hold
- integration with GSM/CDMA handset for mobility
146 Supply, Installation, Testing and Commissioning of IP Phone with display as per tender specification etc. as required. 1.00 Nos 14800.00
“Supplying & erecting push button type telephone instrument having speaker phone Caller ID & hands free dialing system or
equivalent make”
Supply, Installation,Testing and Commissioning of Digital Telephone with DSS console and related software/ licences as per
tender specification etc. as required.
Fire Alarm System Supply, Installation, Testing & Commisioning of microprocessor based Intelligent addresable 1 loop Fire
Alarm Control Panel with each loop and should have a capacity of detector and module combination in one loop, 4 x
character backlit LCD display, Form C contacts for alarm and trouble, Form A for supervisory, Electronic addressing with
automatic device mapping, The panel should have a front panel, for logic programming and editing capacibility from the panel
149 and also should have provision for programming from the PC/laptop, Optional Ethernet port for diagnostics, programming and 1.00 Nos 52500.00
avariety of system reports, Supports up to eight serial annunciators, (LCD, LED-only, and graphic interface), Two-level
maintenance alert reporting, Pre-alarm and alarm verification by point, Alarm ON command manually activates alarm condition,
Four access levels, sufficient number of programmable relay controls for controlling AHUs, pressurization fans, escalators,
monitoring of fire sprinklers and fire hydrant pump, 240 volts AC power supply, Optional earthquake hardening: seismic
Importance Factor 1.5, panel. Approved by UL & FM
150 Supply, installation, connecting, testing and commissioning of Modbus/BACNET card for BMS integration 1.00 Nos 68500.00
151 Supply, Installation, Testing & Commisioning of Battery Backup for FACP min 4 hours 2.00 Nos 1250.00
TENDER FOR CIVIL/INTERIOR/ELECTRICAL/HVAC WORK FOR SARDAR PATEL INSTITUTE PUBLIC ADMINISTRATION (SPIPA), GANDHINAGAR
Sr. No. Description Quantity Unit Rate Amount
Supply, Installation, Testing & Commisioning of addressable microprocessor based photo thermal multi criteria smoke cum heat
detector with mounting based , Integrates optical smoke with rate-of-rise heat sensing, Wide 0.53 to 3.94 %/ft. (1.7 to
152 %/m) smoke obscuration, Two levels of environmental compensation, Two levels of dirty detector warning, Twenty pre-alarm 70.00 Nos 1950.00
settings, Five sensitivity settings, Electronic addressing, Environmental compensation, Automatic day/night sensitivity
adjustment, Bicolor (green/red) status LED. Approved by UL/ FM
Supply, Installation, Testing & Commisioning of Flame Detector and with mounting based , Automatic device mapping, Sensor
153 Markings Provide Easy Testing Identification, Non-volatile memory, Electronic addressing, Bicolor (green/red) status LED. 1.00 Nos 3000.00
Approved by UL/FM
Supply, Installation, Testing & Commisioning of addressabale type Fault isolator for isolating shorted, dewired and loose circuits
154 between two successive fault isolators with automatics resetting arrangement (base model) Approved by UL/FM 4.00 Nos 2500.00
Supply, Installation, Testing & Commisioning of addressable Manual Glass Break station, Intelligent device with integral
155 microprocessor, Electronic Addressing with Non-volatile memory, Automatic device mapping, Diagnostic LEDs, Designed for high 5.00 Nos 3350.00
ambient temperature operation. Approved by UL/FM
Supply, Installation, Testing & Commisioning of Addressable Sounder cum strobe along with required Control Modules with
156 range of 90dbA and 95dbA and field selectable 15/30/75/110 candelas, Select temporal (default) or steady horn output, Select 5.00 Nos 3600.00
public mode flash rate (default) or private mode temporal flash. Approved by UL/FM
Supply, Installation, Testing & Commisioning of control relay module a Form “C” dry relay contact to control external appliances
such as door closers, fans, dampers etc. This device does not provide supervision of the state of the relay contact. Instead, the
on-board microprocessor ensures that the relay is in the proper ON/OFF state. Upon command from the loop controller, the
relay activates the normally open or normally-closed contact. Approved by UL/FM
158 Supply, Installation, Testing & Commisioning of Response Indicator 22.00 Nos 125.00
Supply installation of ISI Marked 2 core x 1.5 mm2, Multistrand Copper, FRLS Armoured cable, RED in Colour, laid on surface
159 with GI saddle-spacers every 0.3 meters. Complete with GI Junction Box, lugs, cable compression glands, cable tags and 700.00 Rmt. 90.00
CCTV SYSTEM Supply,installation ,testing & Commissioning of Vandal Proof 2 MP 2.8 mm Lens Network IR Dome/Bullet Camera
1/2.8" Progressive Scan CMOS; H.265+/H.265/H.264+/H.264/MJPEG;
Color: 0.028 Lux @ (F2.0, AGC ON), 0 lux with IR; 25fps/30fps(1920×1080); VCA
functions; 3 streams; 3D DNR; BLC/HLC; ICR; EXIR, up to 30m; DC12V&PoE
161 Supply,installation ,testing & Commissioning of 18 Port Gigabyte POE Switch with 200W Power Budget 1.00 Nos 18500.00
Supply,installation ,testing & Commissioning of Up to 16 channel IP camera input, Along with Dual Network Interface, Max
Mbps incoming bandwidth, Smart H.265+/H.265/Smart H.264+/H.264/MJPEG, Up to 12MP resolution preview and playback,
USB(2 USB3.0, 2USB2.0), 1 HDMI / 1 VGA simultaneous video output, Support Multi-brand network cameras, Support RAID
163 Supply,installation ,testing & Commissioning of 4 TB Enterprise Surveillance HDD 2.00 Nos 7500.00
164 Supply,installation ,testing & Commissioning of 9 U CCTV Rack Along with Required accessories 1.00 Nos 5500.00
165 Supply, Installation, Testing and Commissioning of RJ 45 Connector 16.00 Nos 50.00
166 Supply, Installation, Testing and Commissioning of LCD Monitor 19" 1.00 Nos 4500.00
167 Supply, Installation, Testing and Commissioning of HDMI CABLE 40.00 Mtr 350.00
PA SYSTEM Supply,installation ,testing & Commissioning of Mixing Controller Min 240 Watt, 6 zones output(on the 100v line)
with stepped volume control for each zone,Along with Voice Evacuation Message Player for Fire Event
169 Supply,installation ,testing & Commissioning of Table Top Microphone Gosneck Mic 1.00 Nos 8500.00
TENDER FOR CIVIL/INTERIOR/ELECTRICAL/HVAC WORK FOR SARDAR PATEL INSTITUTE PUBLIC ADMINISTRATION (SPIPA), GANDHINAGAR
Sr. No. Description Quantity Unit Rate Amount
170 Supply, Installation, Testing and Commissioning of Hyper cardioid dynamic handhold microphone with switch 1.00 Nos 3500.00
Supply of 6 W Ceiling Mount Speaker : This is full range loudspeaker are suitable for both music and music reproduction in all
public address application. It shall durable & reliable technology.
Supply of 12 W Wall / Column Mount Speaker : This is full range loudspeaker are suitable for both music and music
reproduction in all public address application. It shall durable & reliable technology.
173 Volume Control Supports up to 50W, installations on a 3x3 inch electrical mounting box Supply & Fixing. 15.00 Nos 1650.00
174 Supply & Lying of Flexible 2 Core 1.5 Sqmm FRLS Cable along with PVC Conduit & Required Accessories. 800.00 Mtr 80.00
Access Control System Supply,installation ,testing & Commissioning of Single Door ACS Controller 2.4 inch TFT-LCD screen
Fingerprint Identification Fingerprint Capacity: 3,000 Log Capacity: 30,000 Communication:TCP/IP,RS232/485,USB Host Access
Control Interface for electric lock,door sensor,alarm,exit button and door bell. Wiegand input&output
176 Supply,installation ,testing & Commissioning of IP65 Fingerprint + Proximity Reader 2.00 Nos 7000.00
Supply,installation ,testing & Commissioning of EM Lock 600 lbs along with required U Bracket for glass door & L bracket for
Supply,installation ,testing & Commissioning of Web Based Software upto 200 user, along with intergration string for 3rd party
HRMS Payroll System
179 Power Supply for Access Control Controller along enclosure Box 1.00 Nos 700.00
AV System Supply,installation ,testing & Commissioning of Interactive Touch Display : 75inch 4K Professional Interactive Display
min. 400 nits brightness ,8GB RAm and 64GB Storage , Min. 3 x HDMI , USB C , USB3.0 x 4 . USB 2.0 x 1 , RJ45 in/Out, HDMI OUT,
180 Touch Out 2, 40 pointsTouch, Passive Pen with magnet,Touch Overlay(IR), Built in Speaker(10W x 2), WiFi/BT Module 5.00 Nos 120000.00
Embedded, Ops Slot Available. RDP Feature, Android 14 OS, EDLA Certified, 3 Year Warranty (Sony / Samsung / Barco)
Supply,installation ,testing & Commissioning of OPS Intel Core i5 with 8GB RAM, 256GB SSD , windows 11 pro license , HDMI
USB x 2 Wireless Keybaord and Mouse (Netcom / Cirtus / Spectra)
Supply,installation ,testing & Commissioning of 75 inch 4K Professional Display , min. 350 nits brightness , 8GB Storage , Min. 3 x
182 HDMI , 2 x USB , RJ45, Built in Speaker (10W x 2), RDP Feature, EMC Class B, IP5X, 3 Year Warranty (Sony / Samsung / Barco) 1.00 Nos 90000.00
All-in-one video bar with industry-leading AI for daily BYOD meetings, ideal for premium small to medium-sized meeting rooms.
Maximum pixels: 2*48MP pixels, Number of preset positions: 9, Electronic gimbal, 120° DFOV, 54° VFOV, 110° HFOV, Depth of
field: 1-5 meters, 6x digital zoom, 6-meter voice pickup range, Maximum resolution: 4K, Maximum frame rate: 60FPS,
Intelligence Features - IntelliFocus, Auto Framing, Speaker tracking, Built-in 8 MEMS microphone array, Built-in 2 x 10W speakers
( Poly / Sisco / yelink / aver)
184 Supply & Lying of ACTIVE USB 3.0 20 Meter EXTENSION CABLE ( aten/ Kramer / lindy) 20.00 Mtr 650.00
Supply,installation ,testing & Commissioning of 55 inch 4K Professional Display , min. 350 nits brightness , 8GB Storage , Min. 3 x
185 HDMI , 2 x USB , RJ45, Built in Speaker (10W x 2), RDP Feature, EMC Class B, IP5X, 3 Year Warranty ( Sony / samsung / barco) 4.00 Nos 39500.00
TENDER FOR CIVIL/INTERIOR/ELECTRICAL/HVAC WORK FOR SARDAR PATEL INSTITUTE PUBLIC ADMINISTRATION (SPIPA), GANDHINAGAR
Sr. No. Description Quantity Unit Rate Amount
Amplifier Networked Power Amplifier
8Ω, 20 Hz–20 kHz 0.1% THD 260 W, 4Ω, 20 Hz–20 kHz 0.1% THD 425 W, 2 x 125W @ 4/8 Ω, Line–level output, 2ch Dante input
& Stereo Line level input, Built–in DSP, Controllable via RS–232 and IP, Auto standby With All Wiring & Power Point Consider (
Kramer / aten / audse)
SITC of 2-Way Powered Speaker System with 45Hz–20kHz (-10dB) / 50Hz–20kHz (±3dB) frequency response,6.5” polypropylene
woofer with rubber edge & 1” silk dome tweeter, 85dB SPL (1W@1m), max SPL 100dB continuous / 108dB peak. Features
volume, bass & treble control knobs, auto power-off with LED indicator, and multiple inputs: 3.5mm mini-jack, balanced
terminal block, RCA (L/R). Includes U-shaped rotating mounting brackets for flexible installation. Along with all required Cables &
Connector Accessores as required at location ( Kramer / aten / audse)
Supply,installation ,testing & Commissioning of paging podium microphone with a multi-tone electronic chime. With fitted with
a flexible 300mm (12”) gooseneck. (Audio technica / Sennheieser / clock audio)
Supply,installation ,testing & Commissioning of Wireless Handheld microphone, Operate up to 32 compatible systems per
189 MHz band, with easy setup and optional rechargeability accessories for wireless excellence (Audio technica / Sennheieser / clock 1.00 Nos 27500.00
Supply,installation ,testing & Commissioning of Wireless Lavalier/ Headworn microphone, Operate up to 32 compatible systems
per 44 MHz band, with easy setup and optional rechargeability accessories for wireless excellence
Supply,installation ,testing & Commissioning of Wireless Presentation system Wireless Collaboration Device Supports 4K Output
191 Resolution , 4 Display Windows , Miracast, airplay , Dual band Wi-Fi, 256MB RaM, HDMI OUT 1.4 x 1, USB x 2, RJ45x 1, audio x1. 5.00 Nos 60000.00
(Kramer / Crestron / extron )
Supply,installation ,testing & Commissioning of Digital Signal Processor Must be quarter-rack form factor and deliver 4x4
networked audio channels over aES67- compliant Dante™, utilizing two dedicated 1000Mbps RJ45 ports supporting Cat5e and
above The processor shall feature eight (8) integrator-configurable card slots accepting any combination of analog audio
input (with selectable 48V), analog line output, selectable GPIO, relay control, aES/EBU digital audio, and USB via 2x2
192 send/receive over Type-B socket. Within a single processor, the device shall provide up to 16 local channels of analog audio, 2.00 Nos 205000.00
and 32 channels of local GPIO, with expansion permitted via proprietary I/O expansion devices and generic third-party Dante
devices. The device shall feature an openarchitecture, 40-bit floating point processor operating on a Linux platform. ( Alpha
acoustic / symetrix / xilica )
193 Supply,installation ,testing & Commissioning of POE-95W PoE injector power ( Alpha acoustic / symetrix / xilica ) 2.00 Nos 22500.00
All-In-One Meeting Room Scheduling Panel : 8-Inch 10-Point Interactive Panel, Anti Fingerprint Screen, High Visibility LED Bars
194 out Room Status Ambient Light & Proximity Sensor Embedded Optional Connectivity: Wifi & Wired 10/100BaseT Ethernet, PoE 4.00 Nos 54800.00
or DC Power, Make : Creston / Yealink / Poly
Table Mount Modular Multi–Connection Solution — Tilt–Up Lid Rectangular, Tilt–Up Lid, Modular Design - 2 POWER POINT /
HDMI / 2 DATA / 1 USB-A / 1 USB-C / Wirless Charger (Kramer / Creston / Logic or Equvilent)
Supply & Lying of High−performance, HDMI cable.It supports signals up to 4K@60Hz (4:4:4), Deep Color, Lip Sync, 7.1 PCM,
Dolby TrueHD, DTS−HD, CEC.
197 Supply & Lying of 20/22AWG microphone cable 300.00 Mtr 80.00
198 Cables, Rack, Connectors & Accessories 1.00 Job 28500.00
199 Commisioning and Calibration charges 1.00 Job 20000.00
TENDER FOR CIVIL/INTERIOR/ELECTRICAL/HVAC WORK FOR SARDAR PATEL INSTITUTE PUBLIC ADMINISTRATION (SPIPA), GANDHINAGAR
Sr. No. Description Quantity Unit Rate Amount
Fire Suppresion System Supply & Design of Direct Low Pressure System for Main LT Panel , Cylinder BIS Approved filled with FK-5-
1-12 Gas, UL Approved, Suitable for Electrical / Electronic sensitive equipments, Cylinder-deep drawn, Hydrostatic pressure
tested,Direct Low Pressure Valve with two outlets, Brass Nickel Plated, Stainless Steel connectors, 360 Degree Rotational
Handwheel valve for close / open position, Integrated in Valve main body at the top, Secured with Alen key to avoid misuse,
Push In Pnematic Fittings, Valve Inlet M30x 1.5, Valve Outlet G1/8", Diptube Thread M16 x 1.5, Pressure Gauge Thread M10x1,
Seal Seat Diameter 63.6mm2, Operating Pressure 15 to 23 Bar, Test Pressure 28 Bar, Operating temperature -20 Degree C to +
65 Degree C, Safety Device : Burst Disc, Approved by Kiva Inspecta AB, Sweden, PI marked, TPED approved, Used Standards for
type approvals ISO 17871:2015 in conjunction with EN ISO 10297:2014 EN ISO 14246: 2017-12. Note : Gas Calculation have to
consider as per Size of Main LT Panel
Supply & Fixing of End of Line Adapter 1 Nos, Pressure Switch 1 Nos, Heat Sensing Tube 20 Mtrs, T-Connector 1 Nos, End of Line
Plug 1 Nos, Health Monitoring Panel 1 Nos for Fire Suppresion
202 Installation & Commissioning of the fire suppression system 1.00 Job 9500.00
203 Existing Compector Removing & Refixing New Site Karmyogibhavan 1.00 Nos 120000.00
Shifting of existing split AC - Removing , packing , Loading , shifting & transportation from GGL Sanand old office Second floor
location to GGL Sanand New office location at first floor , unloading, re-installation/ testing & commissining of existing split AC
unit including replacement of lost and damaged material such as hardware, accessories etc. The contractor must inspect the
material by visiting the both the sites check the status of existing material. The installation to be done as per approved layout as
per instructions of site incharge and architect. Installation / Testing & commissining of exisitng split AC 1.5 TR (Including Gas
Charging R22 / R410a / R32 etc)
205 2.0 TR (Including Gas Charging R22 / R410a / R32 etc) 10.00 Nos 2800.00
EXTRA COPPER PIPING WITH ELECTRICAL CABLE FOR ALL TYPE SPLIT/ Cassette / INVERTER Acs Extra Copper piping : Supplying,
installation, testing and commissioning of Copper piping For all type SPILT/TOWER/ INVERTER AC Machine insulated pair of soft
copper tubing as per required machine capacity and Original Equipment Manufacturer recommendation with necessary staging
scaffolding, tools etc.,
EXTRA UPVC DRAIN WITH 6MM THK. NITRILE RUBBER INSULATION -20MM DIA Supplying, installation, testing and
commissioning of following sizes of rigid U-PVC piping complete with elbow T-joint, socket duly supported as per specifications
207 and insulated with 6mm thick closed cell nitrile rubber insulation. with necessary zari/civil work for breaking /making holes for 150.00 RFT 55.00
the drain piping in the walls/floors/slab. with necessary staging scaffolding, tools etc., (Cost of Zari/Civil work not included )
EXTRA ELECTRICAL CABLE – 2.5, 4 CORE FOR UPTO 2.0 TR SPLIT Acs & up to 3.0 TR Cassette AC Extra Electrical Cabling :
Supplying, installation, testing and commissioning of XLPE (IS-7098 ) (I)-88 ISI unarmoured copper cable having 1.1 KV grade
208 electrical cabling For all type SPILT/TOWER/ INVERTER AC Machine copper power and control cable as per required capacity.( 560.00 RFT 50.00
Up to 2.00 TR capacity ) to be laid in the conduit pipe on the wall/ceiling/in existing tray as the case may as per the direction of
EIC. with necessary staging scaffolding, tools etc.,
SITC of DX air-cooled Inverter Type Split AC unit complete with Indoor / Outdoor units along with cordless remote controller. (R-
410a / R32 Refrigerant)(Min.3 Star & Cu Cond.) 1.5 TR - Single phase @power at IDU-min 18000 BTU/Hr
For AC system, all refrigerant piping between IDU & outdoor units duly insulated as per specifications. All piping inside the room
shall be properly supported with hanger and exposed piping shall be properly supported with clamp.Exposed piping insulation to
210 be covered with 1 layer of glass cloth and 2 layers of UV paint and all the insulation joints must be covered with EPDM Rubber 50.00 Rmt 850.00
Tape. (Pair Rmt)(including chipping work in wall) For 1.0 / 1.5 TR ( Min 1/4" (0.8mm thk) & 1/2" (0.8mm thk) with min 13 mm
TENDER FOR CIVIL/INTERIOR/ELECTRICAL/HVAC WORK FOR SARDAR PATEL INSTITUTE PUBLIC ADMINISTRATION (SPIPA), GANDHINAGAR
Sr. No. Description Quantity Unit Rate Amount
Supply & Installation of Insulated uPVC drain piping for all Indoor AC units. (All the Insulation joint must be covered with
aerotape.) (minimim 9 mm thick ) (including chipping work in wall) For 25 mm dia piping
212 All Cu armored power cable / control cable between IDU to ODU’s . 250.00 Rmt 260.00
213 L type Wall Mounted Powder coated GI Satnd 12.00 nos 1000.00
Total Amount Put To Tender Rs……….
Total Amount Put To Tender Rs……….
I/We am/are willing to carry out the work@___________________% above/below percent (Should be written in figures and words) of the estimated rate mentioned above. Amount of my/our tender works out as under.
Estimated amount put to tender Estimated amount put to tender
Above all items of "Schedule-B" with item Description, Unit, Rate & Amount have verified by me and found order.
(Vikram Upadhyay) (H.P. SONI)
Site Supervisior Additional Assistant Engineer
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
03_04_INTERIOR CIVIL AND ELECTRIC MAKES LIST.pdf
05_SPIPA PLAN.pdf
06_SPIPA BUYBACK.pdf
01_TB.pdf
02_BOQ.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .