Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.6 LAccepted-AOC | ₹46.6 L | L1 | Accepted-AOC L1 |
| 2 | L2₹46.6 LRejected-AOC | ₹46.6 L | L2 | Rejected-AOC L2 |
| 3 | L3₹46.6 LRejected-AOC BAHADUR ADARSHAGAON P O P S MAZBAT DIST UDALGURI BTC ASSAM PIN 784507 | MAZBAT | UDALGURI | ASSAM | 784507 | ₹46.6 L | L3 | Rejected-AOC L3 |
| Sl No | Description | Qty | Unit | IQBAL QURESHI L1 | Islam Qureshi L2 | Abong Brahma L3 |
|---|---|---|---|---|---|---|
| 1.00 | 5.22.: Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
5.22.4 Hot rolled deformed bars. | 10,340.45 | Kg | 89.65 ₹9.3 L | 89.65 ₹9.3 L | 89.65 ₹9.3 L |
| 2.00 | 5.22.A: Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. 5.22A.1 Mild steel and Medium Tensile steel bars 6mm dia Stirrup for Lintel. | 62.48 | Kg | 88.95 ₹5,557.60 | 88.95 ₹5,557.60 | 88.95 ₹5,557.60 |
| 3.00 | 5.9: Centering and shuttering including strutting, propping etc. and removal of form for
5.9.1 Foundations, footings, bases of columns, etc. for mass concrete. | 66.62 | Sqm | 307.95 ₹20,515.63 | 307.95 ₹20,515.63 | 307.95 ₹20,515.63 |
| 4.00 | 5.9.5: Lintels, beams, plinth beams, girders, bressumers and cantilevers | 175.48 | Sqm | 608.35 ₹1.1 L | 608.35 ₹1.1 L | 608.35 ₹1.1 L |
| 5.00 | 5.9.3 Suspended floors, roofs, landings, balconies and access | 331.8 | Sqm | 766.55 ₹2.5 L | 766.55 ₹2.5 L | 766.55 ₹2.5 L |
| 6.00 | 5.2.: Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :
5.2.2 1:1.5:3 (1 cement: 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). | 62.84 | Cum | 10,185.05 ₹6.4 L | 10,185.05 ₹6.4 L | 10,185.05 ₹6.4 L |
| 7.00 | 5.22.: Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
5.22.4 Hot rolled deformed bars. | 1,022.31 | Kg | 89.65 ₹91,650.09 | 89.65 ₹91,650.09 | 89.65 ₹91,650.09 |
| 8.00 | 5.9: Centering and shuttering including strutting, propping etc. and removal of form for
5.9.1 Foundations, footings, bases of columns, etc. for mass concrete. | 34.9 | Sqm | 307.95 ₹10,747.46 | 307.95 ₹10,747.46 | 307.95 ₹10,747.46 |
| 9.00 | 5.9.5: Lintels, beams, plinth beams, girders, bressumers and cantilevers. | 21.48 | Sqm | 608.35 ₹13,067.36 | 608.35 ₹13,067.36 | 608.35 ₹13,067.36 |
| 10.00 | 5.9.3 Suspended floors, roofs, landings, balconies and access. | 29.24 | Sqm | 766.55 ₹22,413.92 | 766.55 ₹22,413.92 | 766.55 ₹22,413.92 |
Tender Value
₹46.6 L
EMD Value
₹93,195
Closing Date
2 Feb 2026, 2:00 pmClosed
The Addl. Chief Engineer cum Director, PWD, BTC
O/o the Addl. Chief Engineer cum Director, PWD, BTC, Kokrajhar
Extension of 2nd Floor of Adivashi Boys Hostel at Udalguri.
2026_BTC_50175_2
125/ACE/NIT/Infra/BTC/2022-23
Open Tender
Civil Works - Building
180 days
Udalguri
Please refer Tender documents.
4 documents required · 4 mandatory
₹1,000
₹93,195
Yes
5 May 2026
12 Jan 2026
3 Feb 2026
12 Jan 2026
2 Feb 2026
12 Jan 2026
12 Jan 2026 - 2 Feb 2026
5.22.: Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 5.22.4 Hot rolled deformed bars.
5.22.A: Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. 5.22A.1 Mild steel and Medium Tensile steel bars 6mm dia Stirrup for Lintel.
5.9: Centering and shuttering including strutting, propping etc. and removal of form for 5.9.1 Foundations, footings, bases of columns, etc. for mass concrete.
5.9.5: Lintels, beams, plinth beams, girders, bressumers and cantilevers
5.9.3 Suspended floors, roofs, landings, balconies and access
5.2.: Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 5.2.2 1:1.5:3 (1 cement: 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
5.22.: Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 5.22.4 Hot rolled deformed bars.
5.9: Centering and shuttering including strutting, propping etc. and removal of form for 5.9.1 Foundations, footings, bases of columns, etc. for mass concrete.
5.9.5: Lintels, beams, plinth beams, girders, bressumers and cantilevers.
5.9.3 Suspended floors, roofs, landings, balconies and access.
5.2.: Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 5.2.2 1:1.5:3 (1 cement: 1.5 coarse sand(zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources).
6.13: Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. 6.13.2 Cement mortar 1:4 (1 cement :4 coarse sand).
10.14: Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges. 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: 10.14.3 Profile E 10.14.3.2 Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately).
10.11: Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 10.11.1 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size).
9.48: Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. 9.48.1 Fixed to steel windows by welding
13.2: 15 mm cement plaster on the rough side of single or half brick wall of mix: 13.2.1 1:4 (1 cement: 4 fine sand)
9.5: Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately). 9.5.1 Second class teak wood 9.5.1.1 35 mm thick shutters.
10.30: Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with: 10.30.1 4.0 mm thick glass panes
9.96: Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 9.96.1 300x16 mm
9.97: Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 9.97.2 250x10 mm
9.100: Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete: 9.100.1: 125 mm
11.41: Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. 11.41.4 Size of Tile 1000x1000 mm.
11.41 A: Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only. Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. 11.41A.2 Glazed vitrified floor tiles polished finish of size 11.41A.2.1 Size of Tile 600 x 600 mm
11.41 A: Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only. Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. 11.41A.2 Glazed vitrified floor tiles polished finish of size 11.41A.2.2 Size of Tile 600 x 1200 mm.
13.52.: Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. 13.52.2 On concrete work.
13.44: Finishing walls with water proofing cement paint of required shade: 13.44.1 New work (Two or more coats applied @ 3.84 kg/10 sqm)
13.52: Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. 13.52.1 On steel work
SANITARY FITTINGS 17.3: Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: 17.3.1 W.C. pan with ISI marked white solid plastic seat and lid.
17.4: Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: 17.4.1 One urinal basin with 5 litre white P.V.C. automatic flushing cistern.
17.7.A: Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- (a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer.
17.10: Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required: 17.10.1.2 510x1040 mm bowl depth 225 mm
17.31: Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
17.34: Providing and fixing toilet paper holder: 17.34.1 C.P. brass.
17.35: Providing and fixing soil, waste and vent pipes: 17.35.1 100 mm dia. 17.35.1.1 Sand cast iron S&S pipe as per IS: 1729.
17.35: Providing and fixing soil, waste and vent pipes : 17.35.2 75 mm diameter: 17.35.2.1 Sand cast iron S&S pipe as per IS: 1729
17.39: Providing and fixing plain bend of required degree. 17.39.1 100 mm dia 17.39.1.1 Sand cast iron S&S as per IS-1729.
17.39: Providing and fixing plain bend of required degree. 17.39.2 75 mm dia 17.39.2.1 Sand cast iron S&S as per IS-1729.
17.73: Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 17.73.2 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms.
18.8: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 18.8.2 20 mm nominal dia Pipes.
18.8: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 18.8.3 25 mm nominal dia Pipes.
18.8: Providing and fixing Chlorinated polyvinyl chloride (CPVC) pipe, having nthemal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe wityh clamps at 1.00 m spacing. This includes jointing of pipe & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer -in-charge. 18.8.2 20 mm nominal dia Pipes.
18.8: Providing and fixing Chlorinated polyvinyl chloride (CPVC) pipe, having nthemal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe wityh clamps at 1.00 m spacing. This includes jointing of pipe & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer -in-charge. 18.8.3 25 mm nominal dia Pipes.
18.54: Providing and fixing PTMT bib cock of approved quality and colour. 18.54.2 15 mm nominal bore, 122mm long, weighing not less than 99 gms.
18.63: Providing and fixing PTMT bib cock of approved quality and colour. 18.54.2 15 mm nominal bore, 122mm long, weighing not less than 99 gms.
18.64: Providing and fixing PTMT swivelling shower, 15 mm nominal bore, weighing not less than 40 gms.
18.65: Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms.
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.14 MB
SBD.pdf
Tender Documents • 3.03 MB
BOQ_79930.xls
BOQ • 0.28 MB
FOB.pdf
Additional Documents • 0.44 MB
Download all tender documents and submit your bid