Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.2 LAccepted-AOC 0 0 BASANT AVENUE PHASE II PUNJAB GURDASPUR PUNJAB 143505 | GURDASPUR | PUNJAB | 143505 | L1 | Accepted-AOC being L1 | |
| 2 | L2₹5.4 L+₹8,289 (1.57%)Rejected-AOC JJ BHAVAN TC 10 1378 2 GN 31 CHENCHERY ROAD NALACHIRA PO TRIVANDRUM 695 015 | TRIVANDRUM | THIRUVANANTHAPURAM | KERALA | 695015 | L2 | Rejected-AOC being L2 | |
| 3 | L3₹5.5 L+₹17,880 (3.39%)Rejected-AOC JANAKI NIVAS BEHIND CHOVVA TEMPLE CHOVVA PO KANNUR KERALA 670006 | KANNUR | KANNUR | KERALA | 670006 | L3 | Rejected-AOC being L3 |
Tender Value
₹6 L
EMD Value
₹12,000
Closing Date
23 Oct 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE I Cannanore
AGE I Cannanore HQ Hospital Kannur PO 670017
Periodical cleaning and descaling of shallow wells and connected works at Mily Station Kannur and Calicut under AGE (I) Cannanore.
2023_MES_619704_1
8303
Open Tender
Civil Works - Water Works
Item Rate
180 days
Cannanore
Category E a (ii) b (i)
8 documents required · 8 mandatory
₹500
Yes
AGE I Cannanore
₹12,000
Yes
1 Nov 2023
20 Sept 2023
26 Oct 2023
21 Sept 2023
23 Oct 2023
5 Oct 2023
21 Sept 2023 - 4 Oct 2023
Amount
KANNUR & CALICUT AREA
M&L for bailing out water from the open wells/shallow wells having MS grills/angle frame/concrete slab cover on top, having a dia meter of 40 feet and depth 40 feet Located at well No 1, well No 2, well No 3 at Jubily park at Kannur by using diesel pump set of suitable capacity and excavated the sludge deposited from the bottom of well with suitable equipments, getting out and remove to a distance n.exc 50m away from the well, cleaning the well bottom and steining with potable water and bleaching powder thoroughly, trimming out and remove small trees/bushes etc from the well, cleaning of external steining wall with iron grill, water testing of fresh water and ensure potability of water complete all as specified and directed.
All as per item No 2 here in before but well of dia 15 feet and depth 40 feet located at INP area complete all as specified and directed.
All as per item No 2 here in before but well of dia 16 feet and depth 60 feet located at Payyambalam area complete all as specified and directed.
All as per item No 2 here in before but well of dia 11 feet and depth 40 feet located at WL area complete all as specified and directed.
All as per item No 2 here in before but well of dia 16 feet and depth 30 feet located at Butcherry area complete all as specified and directed. Note for item No 2 to 6 : 1.Test certificate shall be obtained from any Govt approved lab and submitted before claiming RAR/FB and enter in MB. 2. Quoted rate included the cost of scaffolding, pump set, deisel etc to comlete the work.
Supply, laying, jointing and testing HDPE pipe, 80mm bore, of pressure rating 10Kgf/cm2 including HDPE fittings such as bends, elbows, tees, reducers, short pieces, connectors, back nuts, caps, plugs, etc; laid in bore well/open well/UG sump including taking out old unserviceable pipe any dia all as specified and directed.
Supply and fix cast iron sluice valve 150mm bore, flanged type, heavy duty, class PN 1.6, conf to IS 14846 hand wheel operated, short body with high tensile steel spindle and iron wheel, fixed complete with rubber gasket joints including nuts & bolts, washers complete etc including taking out old unserveceable sluice valve all as specified and directed.
M & L for construction of valve chamber of size 1200x1200x900mm with PCC (1:4:8), type D2 using 40mm graded stone aggregate for foundation, brick wall with sub class ‘B’ old size brick, built in cement mortar (1:4), plastering with cement mortar 10mm thick inside and outside 3.15mm thick MS sheet cover framed with angle iron 40mm x 40mm x 6mm thick and locking arrangement, painting to steel surfaces with two coats of anti-corrosive paint over one coat of red-oxide zinc chrome primer including necessary excavation and earth work, including demolition of existing damaged valve chambers and removing rubbish outside MD land complete all as specified and directed.
S & F rubber tighten gaskets for jointing 150mm bore CI flanged pipes, Sluice valve, NRV, ARV, flanged fittings complete including taking out old unserviceable gasket all as specified and directed.
M&L for replacement of poly propyeline rope 20mm dia, solid braided ropes, 5.5m per kg including all accessoreis required for tighetening the rope with pump set in open well/tube well all as directed by Engineer in Charge.
Cutting of grass/vegetation all around the well and pump house area with bush cutter machine of approximate area of 250 sqm each including cleaning of area, trimming of tree branches surrounded to the well / Pump house area complete all directed. Note : All T & P, petrol, safety boots, helmet etc for incorporation of work shall be provided by the contractor an is included in the quated rate.
Cutting of tree branches of girth n exc 20cm all around the pump house area with tree cutter machine including removing and clear the site complete all as directed.. Location : Main pump house DSC Centre, INP pump house, Mill road pump house, PAO OR Qtrs, MH pump house and DAD Qtrs payyambalam Note : All T & P, petrol, safety boots, helmet etc for incorporation of work shall be provided by the contractor an is included in the quated rate.
M & L for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit vertically to a depth of not less than 2.25 m below ground level) with top edge of plate at a depth of not less than 1.5 m below normal ground level, connected to galvanized iron strip of 32 x 6 mm as earth lead and all as directed. by means of bolts, nuts, check nuts and washers of galvanized iron or steel connected to earthing test point, continuous earth lead protected by using GI pipe light grade 40mm bore, 15 mm dia GI pipe light grade for watering funnel including necessary excavation, earth work in any type of strata, PCC pit and RCC chamber cover complete including test point made out of steel plate of size 75x75x6mm fixed to wallall as specified and as shown in electrical plate No 5 of SSR Part-I including dismantling old unserviceable earthing all as directed. Note :- Rate quoted shall deem to include for GI earth strip and GI pipe lead upto 7.5m length.
Supply and lay including fixing and connecting electrically XLPE insulated LT underground cable, 3.5 core 35 sqmm armoured heavy duty electric cable with aluminum conductor multi-stranded 1100 volts grade, laid in trench, fixed on wall/pole drawn through pipe etc including provision of lugs & testing of following sizes complete all as specified and directed.
M&L for 75mm thick PCC 1:3:6, type C2 using 40mm graded stone aggregate as in sub base for floors finished even and fair all as specified and directed
Cutting the existing hard standing/ bituminous road surfaces for laying cable / GI pipe etc and providing plain cement concrete (1:2:4) ,type B1, using 20 mm graded stone aggregate for filling road cuttings surfaces and making good the disturbed surfaces all as specified and directed. Note : Excavation required below paving/road shall be measured and paid seperately.
M & L for galvanised iron tubing medium grade with all fittings laid along the pole/in trenches / under road or floor of 40 mm bore including removing the rusted old one complete all as specified and directed.
Collecting the water sample in the sterilized container from the Sump/OH tank in presence of Engineer in charge or his representative and tested in National/state govt authorised laboratory such as PHE/NTH or any Govt approved agencies and carrying out the physical/chemical/Bioligical analysis and submitting the detailed report as per standard perimeter in duplicate all as specified and as directed. Note : i) Interval of testing shall be 3 months per each collecting point till the completion of work. ii) All test report shall be submitted to AGE (I) Cannanore before claiming the RAR/FB.
Taking down existing cast iron sluice valve 150mm bore, flanged type, from valve chamber and refixing after repairing and servicing including new gasket, nut, bolts rubber packing etc complete connecting, testing and commissioning all as specified and directed. Note : The quoted rate included the cost of spares.
Taking down existing cast iron sluice valve 100mm bore, flanged type, from valve chamber and refixing after repairing and servicing including new gasket, nut, bolts rubber packing etc complete connecting, testing and commissioning all as specified and directed. Note : The quoted rate included the cost of spares.
S & F rubber tighten gaskets for jointing 100mm bore CI flanged pipes, Sluice valve, NRV, ARV, flanged fittings complete including taking out old unserviceable gasket all as specified and directed.
S & F rubber tighten gaskets for jointing 80mm bore CI flanged pipes, Sluice valve, NRV, ARV, flanged fittings complete including taking out old unserviceable gasket all as specified and directed.
JEETH CONSTRUCTION
T.P.SUNIL KUMAR
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .