| 1.00 | OD156895/2025-2026:Supply Installation and testing and commissioning of 3 kVA online UPS pure sinewave with
120 min backup with tubular C10 battery with minimum VAH of 9600. a) 1 ph to1 ph with by
pass arrangement, b) Input pf > 0.95 @ full load, c) Output pf : >.95 d) Input voltage range :
160V -280V with cut off e) THD .9 % g) Ambient Temperature :
0-40°C h) Generator Compatibility available. i) Pure sine wave. j) Battery over charge & under
charge cut off. k) Bypass arrangement. i) EN/IEC620401 for General Safety compatibility j)
LED/LCD Display with digital indications of Input V & A, output V & A, Battery charge,
Temperature, frequency q) Approved UPS make : APC/Delta/Numeric, r) Approved C10 rated
battery make:-Exide/Quanta/Amaron, s) Architecture Tower type only (rack mountable not
acceptable. t)Marking CE, BIS, ROHS u) All certificates copy to be submitted. v)Three year
warranty. Battery rack : Painted MS angle iron rack Suitable for the battery supplied. | 1 | each | 1,29,000 ₹1.3 L |
| 1.00 | 2.3.2:Supplying and fixing following way, single pole and neutral, sheet steel, MCB
distribution board, 240 volts, on surface/ recess, complete with tinned copper
bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted
including earthing etc. as required. (But without MCB/RCCB/Isolator)
8 way, Double door | 1 | each | 2,600 ₹2,600 |
| 1.00 | 2.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCB
distribution board, 240 volts, on surface/ recess, complete with tinned copper
bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted
including earthing etc. as required. (But without MCB/RCCB/Isolator)
12 way, Double door | 1 | each | 2,300 ₹2,300 |
| 1.00 | 2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature
circuit breaker suitable for inductive load of following poles in the existing MCB
DB complete with connections, testing and commissioning etc. as required.
Single pole | 12 | each | 260 ₹3,120 |
| 1.00 | 2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps | 2 | each | 450 ₹900 |
| 1.01 | 2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.
25 amps | 1 | each | 2,100 ₹2,100 |
| 1.01 | 1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm | 85 | metre | 128 ₹10,880 |
| 1.01 | 1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm | 10 | metre | 145 ₹1,450 |
| 1.01 | 1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm | 38 | metre | 100 ₹3,800 |
Tender Value
₹1.9 L
EMD Value
₹4,865
Closing Date
28 Oct 2025, 6:00 pmClosed
Assisstant Executive Engineer
Office of the Assisstant Executive Engineer PWD Electrical Subdivision Thalassery
DEPOSIT-SITC of UPS at Revenue Offices Muzhakunnu Village Office_ SITC of UPS and Additional Electrical Works-General Electrical Work
2025_PWD_799227_2
PWD/BLDG/TR/4757/2024_6_36_34
Open Tender
Electrical Works
90 days
KANNUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹555
₹4,865
2 May 2026
21 Oct 2025
31 Oct 2025
21 Oct 2025
28 Oct 2025
21 Oct 2025
Amount
ELETRIFICATION
OD156895/2025-2026:Supply Installation and testing and commissioning of 3 kVA online UPS pure sinewave with 120 min backup with tubular C10 battery with minimum VAH of 9600. a) 1 ph to1 ph with by pass arrangement, b) Input pf > 0.95 @ full load, c) Output pf : >.95 d) Input voltage range : 160V -280V with cut off e) THD .9 % g) Ambient Temperature : 0-40°C h) Generator Compatibility available. i) Pure sine wave. j) Battery over charge & under charge cut off. k) Bypass arrangement. i) EN/IEC620401 for General Safety compatibility j) LED/LCD Display with digital indications of Input V & A, output V & A, Battery charge, Temperature, frequency q) Approved UPS make : APC/Delta/Numeric, r) Approved C10 rated battery make:-Exide/Quanta/Amaron, s) Architecture Tower type only (rack mountable not acceptable. t)Marking CE, BIS, ROHS u) All certificates copy to be submitted. v)Three year warranty. Battery rack : Painted MS angle iron rack Suitable for the battery supplied.
2.3.2:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way, Double door
2.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way, Double door
2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 amps
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.17.6:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm
1.17.9:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.9 x 1.5 sq. mm
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
1.27.5:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm)
1.27.4:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
1.27.3:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4 Module (125mmX75mm)
1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
90.10.1.5:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )6 module moulded plastic box on surface
1.28.4:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.6 Module
1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
90.10.3.15:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator
90.10.3.32:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3 pin plug top with indicator
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
OD156898/2025-2026:Supply and providing earth lead from the test joint to the earth electrode using the following sizes of conductors/ strips including cutting, drilling necessary holes (in case of strip) and fixing firmly with plate test joint etc as required. 25 mm X 3 mm G.I. strip
OD156893/2025-2026:Supply and providing test joint for the earthing system using 2 Nos of the following sizes of strips including cutting and bending to shape, drilling necessary holes and fixed to the watering pipe etc as required. 2 x 25 x 3 mm GI strip
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
OD156892/2025-2026:Supplying and providing 25x3m brass nut and bolt etc as required
OD156891/2025-2026:Supply and fixing 32A, HRC Fuse with HRC Fuse link with connections, in existing meter board/panel.
OD156896/2025-2026:Supplying and fixing 32 A, 2 Way neutral links mounted on DMC/SMC base with connections, in existing meter board
OD156897/2025-2026:Supply and installation of switch gear units in sheet steel enclosure complete with handle assembly , door interlock pad and locking arrangement of the following ratings on existing angle iron frame work or directly to wall using necessary nuts&bolts, fixing the unit to wall, making good damages, colour washing etc. including giving necessary connections as required. 32Amp SP&N AC 23A with ISI marked HRC fuse
OD156890/2025-2026:Supply and fixing 32 mm dia 6Kgff/cm2 PVC pipe including fixing the pipe with clamp/clips at 60cm spacing. etc as required (For Service Pipe)
OD156894/2025-2026:Supply and providing suitable Iron Hook grouted on wall for binding the service wire
OD156899/2025-2026:Supply and installation of 1 phase meter board with provision for fixing KSEB energy meter, cut out fuse unit etc.(syntex make GSMB 3525/Equivalent)
Bidder Name
Vinod Kumar M
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1358239.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.05 MB
specificconditionNEW.pdf
Tender Documents • 0.34 MB
MOM.pdf
Tender Documents • 0.19 MB
viewnit.pdf
Tender Documents • 0.03 MB
viewsbd.pdf
Tender Documents • 1.63 MB
BOQ_1358239.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid