Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.0 LAccepted-AOC 441 G F LIG FLATS PH 2 SEC 14 PKT 3 DWARKA NEW DELHI SECTOR 14 DWARKA DWARKA SOUTH WEST DELHI DELHI 110078 | SOUTH WEST DELHI | DELHI | 110078 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹22.0 L+₹2.0 L (9.86%)Rejected-Finance 44 NEAR DURGA MANDIR TRIPURI TOABA TRIPURI TOWN PATIALA 147004 PB | PATIALA | PUNJAB | 147004 | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹22.9 L+₹2.9 L (14.6%)Rejected-Finance STREET NO 10 MALLOMAZRA ROAD BHAKHRA ENCLAVE PATIALA PB | PATIALA | PUNJAB | 140401 | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹37.6 L+₹17.6 L (87.9%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹49.0 L
EMD Value
₹97,942
Closing Date
25 May 2024, 6:00 pmClosed
GE AF AMBALA
GE AF AMBALA
REPAIR/MAINT OF INTERNAL WIRING DISTRIBUTION BOARD, LIGHT FITTINGS AND ALLIED ITEMS IN DOMESTIC AREA AT AF STN AMBALA UNDER GE (AF) AMBALA
2024_MES_651408_1
GE AF/ AMB-T-100/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE AF AMBALA
ALL AS PER NIT AND TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE AF AMBALA
₹97,942
Yes
21 Jun 2024
27 Apr 2024
27 May 2024
27 Apr 2024
25 May 2024
11 May 2024
Amount
Taking down carefully aluminum point wiring (light, fan, socket or power) complete fittings such as switches, ceiling roses, Pendants DBs, sockets etc. including taking down carefully by unscrewing from boards/outlet/DBs/fittings such as switches, sockets, lamp holders, brackets, ceiling fittings bulkhead fittings, sketch fittings, tube light fittings, fan regulator, electric meters, meter box any type etc as directed by Engineer-in-Charge. Making good to the disturbed surface by plastering and two coat of distamper matching with existing surface. complete all as specified and directed
M&L for concealed point wiring complete with 1.5 Sqmm single core multistranded copper conductor FRLS PVC insulated and unsheathed cable 1100 volts grade drawn through and including non metallic rigid PVC conduit,medium grade minimum 19mm dia ISI marked and conduit accessories fixed concealed in wall with sunken type pressed steel/welded MS terminal boxes made out of 1.6 mm MS sheet, 3mm thick laminated sheet top cover for mounting of fittings,switches,sockets outlets,regulators etc complete including provisining of 1.5 sqmm FRLS PVC insulated unsheathed cable 1100 volt grade with multi stranded copper conductor to common earth and connected to earth dolly for the following :-
One light/fan/ controlled by one switch 6 amp one way, complete all as specified and directed
One 3 pin socket outlet 6 amp on the independent board complete all as specified and directed
One 3 pin socket outlet on same board with other switches complete all as specified and directed
one bell point controlled by one bell push complete all as specified and directed
one light point controlled by two way switch complete all as specified and directed
All as per BOQ srl item No. 2.00 described above but point wiring with 2.5 sqmm single core multi stranded copper conductor FRLS PVC insulated & unsheathed cable 1100 volt grade and 2.5 sqmm FRLS PVC insulated and unsheathed cable 1100 volt grade with multi stranded copper conductor for earth wire for 15/16 amp multi purpose socket combination point on independent board complete all as specified and directed Note: For item 2 The rate of chase cutting and making good the surface will be deemed in the rates quoted by the contractor.
M & L for point wiring in existing concealed conduit complete with 1.5 Sqmm single core multistranded copper conductor FRLS PVC insulated and unsheathed cable 1100 volts grade drawn through existing conduit including provisining of 1.5 sqmm FRLS PVC insulated unsheathed cable 1100 volt grade with multi stranded copper conductor to common earth and connected to earth dolly with sunken type pressed steel/welded MS terminal boxes made out of 1.6 mm MS sheet, 3mm thick laminated sheath top cover for mounting of fittings,switches,sockets outlets,regulators etc complete for the followings
One light/fan/ controlled by one switch 6 amp one way, complete all as specified and directed
One 3 pin socket outlet 6 amp on the independent board, complete all as specified and directed
One 3 pin socket outlet on same board with other switches, complete all as specified and directed
One bell point controlled by one bell push complete all as specified and directed
One light point controlled by two way switch complete all as specified and directed
All as per BOQ srl Item No.4.00 here-in-above but point wiring with 2.5 sqmm single core multi stranded copper conductor FRLS PVC insulated & unsheathed cable 1100 volt grade and 2.5 sqmm FRLS PVC insulated and unsheathed cable 1100 volt grade with multi stranded copper conductor for earth wire for 15/16 amp multi purpose socket combination point on independent board, complete all as specified and directed
M & L for point wiring on wall/ surface in PVC conduit/ casing caping of size 20 mm complete with 1.5 Sqmm single core multistranded copper conductor FRLS PVC insulated and unsheathed cable 1100 volts grade drawn through PVC conduit/casing caping including provisining of 1.5 sqmm FRLS PVC insulated unsheathed cable 1100 volt grade with multi stranded copper conductor to common earth and connected to earth dolly with sunken type pressed steel/welded MS terminal boxes made out of 1.6 mm MS sheet, 3mm thick laminated sheath top cover for mounting of fittings,switches,sockets outlets,regulators etc complete for the following
One light/fan/ controlled by one switch 6 amp one way,complete all as specified and directed
One 3 pin socket outlet 6 amp on the independent board complete all as specified and directed
One 3 pin socket outlet on same board with other switches complete all as specified and directed
One bell point controlled by one bell push complete all as specified and directed
All as per BOQ srl item No.6.00 here-in-above but point wiring with 2.5 sqmm single core multi stranded copper conductor FRLS PVC insulated & unsheathed cable 1100 volt grade and 2.5 sqmm FRLS PVC insulated and unsheathed cable 1100 volt grade with multi stranded copper conductor for earth wire for 15/16 amp multi purpose socket combination point on independent board, complete all as specified and directed
S&F in replacement switch modular type 5 amp single pole flush type one way of existing make complete all as specified and directed by EIC.
S&F in replacement switch modular type 15 amp single pole flush type one way of existing make complete all as specified and directed by EIC.
S&F in replacement modular step type fan regulator electronic type 120 watt 1 module of existing make complete all as specified and directed
M&L in replacement socket outlet modular type 5 pin 5 amp multi pin flush type of exising make complete all as specified and directed by EIC
M&L in replacement socket outlet modular type 5 pin 15 amp multi pin flush type of exising make complete all as specified and directed by EIC
S&F in replacement modular cover plate with frame for 1 module of exising make complete all as specified and directed
S&F in replacement modular cover plate with frame for 3 module of exising make all as specified and directed.
S&F in replacement modular cover plate with frame for 6 module of exising make complete all as specified and directed
S&F in replacement modular cover plate with frame for 8 module of exising make complete all as specified and directed
S&F in replacement modular metal flush box 1 module of exising make complete all as specified and directed
S&F in replacement modular metal flush box 3 module of existing make complete all as specified and directed
S&F in replacement modular metal flush box 6 module of existing make complete all as specified and directed
S&F in replacement modular metal flush box 8 module of existing make complete all as specified and directed
M&L in replacement switch piano flush type single pole, one way 6amp complete all as specified and directed
M&L in replacement switch piano flush type single pole, two way 6amp complete all as specified and directed
M&L in replacement switch piano flush type single pole, one way 15 amp complete all as specified and directed
M&L in replacement socket outlet 2 in 1 , 3 pin 5 A flush type complete all as specified and directed
M&L in replacement socket outlet 2 in 1 , 3 pin 5 A and 15 A flush typecomplete all as specified and directed
S/fix in replacement ceiling rose 65x50mm three terminals 230 volt complete all as specified and directed
S& F in replacement lamp holder,PVC/Polycarbonate type and back plate suitable for batten fitting, complete all as specified and directed
Supply and fixing in replacement bell push flush type 230 Volt complete all as specified and directed
S&F in replacement call bell ding dong 230 V single phase complete all as specified and directed
S&F in replacement socket type fan regulator electronic type complete all as specified and directed
Taking down/out old unserviceable FTL fitting of any wattage and Supply and fixing Box type LED tube light fitting 1x18 watt, 230 volts in commercial channel with powder coated CRCA sheet housing with incluiding LED tubelight with high efficient LED in aluminium housing with clear & milky diffuser connecting with twin core twisted flexible copper conductor cable of suitable size complete with all accessories complete all as specified and directed Note : The LED fitting should Have input voltage 90-300V, luminaries efficacy > 100 lumen/watt
Taking down/out old unserviceable FTL tube rod of any wattage and Supply and fixing LED tube rod 1x18 watt, 230 volts complete with all accessories complete all as specified and directed Note : The LED rod should Have input voltage 90-300V luminaries efficacy > 100 lumen/watt
Taking down/out old unserviceable recessess/ surface mounting fitting of any wattage and Supply and fixing recess/Surface mounting LED flat panel 2'x2' with high efficient LED & glare free full window opal diffuser of 36 watt incl connecting with twin core twisted flexible copper conductor cable with suitable size complete with all accessories complete all as specified and directed Note : The LED fitting should Have input voltage 90-300V . luminaries efficacy > 100 lumen/watt
Taking down/out old unserviceable FTL fitting of any wattage and Supply and fixing LED batten with opal diffuser with inbuilt LED tube 10 watt 2 feet length and driver designed with high transmitting optics for even light distribution incl connecting with twin core twisted flexible copper conductor cable with suitable size complete with all accessories complete all as specified and directed Note : The LED fitting should Have input voltage 90-300V, luminaries efficacy > 100 lumen/watt
Taking down/out old unserviceable bulk head fitting of any wattage and Supply and fixing in replacement LED bulk head 10 watt with pressure die cast plasitc housing high efficient LEDs and enclosed with milky diffuser incl connecting with twin core twisted flexible copper conductor cable with suitable size complete with all accessories complete all as specified and directed Note : The LED fitting should Have input voltage 90-300V, luminaries efficiency > 100 lumen/watt
Taking down/out old unserviceable building security light of any type / wattage and Supply and fixing LED light fittings 45 watts, input 120 volts to 280 volts volts, life > 25000 Hrs, operating temp -20 degree to 50 degree,color temperature 5700K, initial efiicacy>= 100 lm/watt ,IP 66 , high pressure Die cast aluminium housing with weather proof gasket for lamp . the driver must be constant current type having THD <10% and power factor >0.95 with short circuit protection , open circuit protection, reverse circuit protection, high voltage protection, protection against 5 KV high surges, the luminaire must have secondary optics with perfectly matched lenses for better light control and comply to IEC60598/IS10322 necessary connection with multistranded copper conductor cable 3 core 1.0 sqmm from ceiling rose to fitting drawn through GI bracket complete all as specified and directed .
M&L for submain wiring in relacement with 2 runs of copper conductor FRLS PVC insulated unsheathed cable 1100 volt grade 4 sqmm drawn through PVC conduit medium grade ISI marked 25mm dia as per IS specification fixed concealed in wall including conduit and conduit accessories and incl provn of PVC insulated 4.0 Sqmm FRLS multistranded copper conductor as earth continuity conductor connected to earthing point of DB box all as specified including dismantling old and making good to the disturbed surface by plastering and two coat of distamper matching with existing surfaces complete all as specified and directed Note : Two runs of 4 sqmm cable alongwith one run of 4.0 Sqmm PVC insulated unsheathed copper conductor as earth wire, conduit and conduit accessories will be measured as one length.
All as per BOQ srl item No 36 above but for 2x6 sqmm copper conductor FRLS cable and 1x6 sqmm copper conductor FRLS cable for earth continuity as a earth wire drawn in PVC conduit 25 mm dia conduit medium grade complete all as specified and directed by Eng-in-Charge.
S&F in replacement recess mounting LED down light of 15 watt of existing make/model complete all as specified and directed.
S&F in replacement recess mounting low height backlit round LED down light of 18 watt of existing make/model complete all as specified and directed.
S&F in replacement recess mounting low height backlit square LED down light of 6 watt of existing make/model complete all as specified and directed.
S&F in replacement recess mounting low height backlit square LED down light of 3 watt of existing make/model complete all as specified and directed.
S&F in replacement LED post top made in cast aluminium spigot housing with decorative opal acrylic diffuser and IP 65 protection of 40 watt with necessary connection of multistranded copper conductor complete all as specified and directed.
Supply and fix incl taking down LED garden light fitting with LED bulb upto 9 watt with clear acrylic cover in top section with IP 43 protection including all electrical connection with gi pipe light grade upto 90 cm including foundation complete all as directed by Engr in Charge.
S&F incl taking down LED strip 1 watt flexible type warm white in colour 10 mm width, complete all as specified and directed
S&F incl taking down driver suitable for LED strip of 1 watt, complete all as specified and directed
S&F in replacement LED bush light 6 watt (warm white) and input voltage 230 VAC , 50 Hz with cast aluminium housing with toughened glass IP-66 including fixing arrangement into wall/ pillar with necessary connection of suitable size of copper conductor cable complete all as specified and directed by Engr-in- charge at site.
S&F in replacement Aesthetically disigned LED post top lantern 15 Watt and input voltage 230 VAC , 50 Hz , with die cast aluminium spigot & prismatic diffuser , IP-65/66 including fixing arrengment like clamp nut bolts and washers and necessary connection of suitable size of copper conductor cable complete all as specified and directed by Engr-in- charge at site.
S&F in replacement Hylum Sheet of size 4X5, complete all as specified and directed
S&F in replacement Hylum Sheet of size 8X5 complete all as specified and directed
S&F in replacement Hylum Sheet of size 10X5, complete all as specified and directed
S&F in replacement Hylum Sheet of size 8 x 10 , complete all as specified and directed
S & F in replacement Hylum Sheet of size 10X12' complete all as specified and directed
S & F ( in repacement) PVC round plate cover of size 4" to 6"complete all as specified and directed
Taking out/dismantling of pressure pump of capacity 0.5 -1.0 HP at site transport to reputed workshop for rewinding the pressure pump with the same gauge of copper winding wire as well as number of turns and reassembling the pump after replacing the unserviceable spares part like bushes, shafts, fasteners, bearings, capacitors and copper wire for putting pump in serviceable condition including refixing the same after carrying out necessary repairs to original place complete all as specified and directed by Engineer-in-Charge . Note :- Spare parts , rewinding work etc required for repairing the pump shall be deemed to be included in the quoted rate by contractor.
Taking down old unserviceable Auto cut and supplying and fixing of new auto cut (pressure release valve ) suitable for pressure pump of capacity 0.5 -1.0 HP complete all as directed by Engr -in- charge at site.
S&F in replacement LED lamp 9 watt complete all as specified and directed
S&F in replacement LED lamp 7 watt complete all as specified and directed
S&F in replacement of casing caping of size 20 mm with necessary fitting complete all as specified and directed by the EIC.
S&F in replacement gang box 2 module suitable for mounting of 6 /16 switch and socket with necessary copper conductor cable complete all as specified and directed
S&F in replacement gang box 4 module suitable for mounting of 6 /16 switch and socket with necessary copper conductor cable complete all as specified and directed
S&F in replacement gang box 6 module suitable for mounting of 6 /16 switch and socket with necessary copper conductor cable complete all as specified and directed
S&F in replacement gang box 8 module suitable for mounting of 6 /16 switch and socket with necessary copper conductor cable complete all as specified and directed
S& F in replacement gang box 12 module suitable for mounting of 6 /16 switch and socket with necessary copper conductor cable complete all as specified and directed
S&F in replacement sheet metal enclosures 4 way TPN Vertiacal type loadline distribution board of 4 way incomer + 12 module outgoings , double door IP 43 protection 160 A rated bus bar blanking plates duly flush in wall and making good disturbed surfaces complete all as specified and directed .
S&F in replacement sheet metal enclosures for MCB distribution board 415 Volts three pole and neutral 4 way double door type flushed inside the wall with 200 Amp rated bus bar incl making the surface good complete all as specified and directed.
S&F in replacement sheet metal enclosures for MCB distribution board 230 Volts single pole and neutral 8 way double door type flushed inside the wall with 200 Amp rated bus bar incl making the surface good complete all as specified and directed.
S&F in replacement sheet metal enclosures for MCB distribution board 230 Volts single pole and neutral 4 way double door type flushed inside the wall with 200 Amp rated bus bar incl making the surface good complete all as specified and directed.
S&F in replacement sheet metal enclosures for MCB distribution board 230 Volts single pole and neutral 12 way double door type flushed inside the wall with 200 Amp rated bus bar incl making the surface good complete all as specified and directed.
S&F in replacement MCCB three pole 415 Volts, 100 A, 16 KA complete all as specified and directed.
S&F in replacement MCB three pole and neutral 415 Volts, 63 A, 10 KA complete all as specified and directed.
S&F in replacement MCBs 5 to 40 amp SPN C curve 240 Volts 10 KA finger proof terminal, bi-connect termination, label holder, 35 mm² terminal capacity, insulated sliding shutter, large two position dolly, ISI marked to be fixed on DB, complete all as specified and directed
S&F in replacement MCBs 5 to 32 amp SP C curve 240 Volts 10 KA finger proof terminal, bi-connect termination, label holder, 35 mm² terminal capacity, insulated sliding shutter, large two position dolly, ISI marked to be fixed on DB, complete all as specified and directed
Supply and fixing in replacement plug top of 15 Amp capacity 240V, single phase includingb connection complete all as specifeid and directed.
M&L earthing complete with galvanized steel earth plate electrode 600x600x6.0 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level,the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15cm on all side and including connected toand including galvanized earth lead wire 4.0 mm dia upto 7.5 mtrs long by means of nuts and bolts, check nuts and washers of GI and connected to earhing test point and earth dolly all as shown in electrical plate No 3 of MES SSR part I and testing on completion including necessary excavation and earth work in any type of soil,PCC(1:3:6) type C1 chamber,pre-cast RCC slab 50mm thic in cement concrete (1:2:4),type B1,reinforced with welded steel wire fabric or XPM,(weight not less than 4 Kg per Sqm) with cast iron frame,funnel with watering pipe 20mm dia medium grade,wire mesh and lugs,GI protection pipe,15mm dia,light grade,7.5 mtr long for protection of earth lead upto test point etc all as specified and as directed. Note : (i) Any variation in length of earth lead and protection pipe of earth lead shall be adjusted through DO. (ii) On testing, if the desired earth resistance is not obtained, enitre earthing shall be re-done by contractor till the desired earth resistance is obtained without accruing any extra cost to the government. (iii) The chamber shall be constructed atleast 1.5 mtr away from the earth electrode.
S&F, connecting & testing in replacement plug top & socket with sheet metal enclosures Single pole including one MCB 20 Amp, 240 Volts,10 KA complete all as specified & directed by Engineer-in-Charge.
S&F in replacement 1100 Volts grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connection twin core flat of size 6 sqmm sold aluminium conductor., complete all as specified & directed
S&F in replacement 1100 Volts grade heavy duty cable PVC insulated aluminium conductor derved with inner sheathing of PVC tape and overall PVC sheathed in service connection twin core flat of size 10 sqmm sold aluminium conductor, complete all as specified & directed
S&F in replacement PVC insulated single core copper conductor of 1.5 sqmm, complete all as specified & directed
S&F in replacement PVC insulated single core copper conductor of 2.5 sqmm, complete all as specified & directed
S&F in replacement PVC insulated single core copper conductor of 6 sqmm, complete all as specified & directed
S&F in replacement PVC insulated single core copper conductor of 4 sqmm, complete all as specified & directed
S&F in replacement 2 core Flexible wire of 23/2, complete all as specified & directed
Taking out/dismantling of old unserviceable check valve of pressure pump of capacity (0.5 to 1 HP) and supply and fixing of new check valve made of brass size 15/25/32 mm dia complete all as specified & directed
Mohinder Pal and Sons
gurchan singh & sons.
NAVIN KUMAR
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .