| 1 | L1₹11.4 LAccepted-AOC 24 824 GOVERDHAN COLONY MAIN BHIND ROAD GOLE KA MANDIR | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹12.7 L+₹1.2 L (10.4%)Rejected-Finance 202 NEW RAM VIHAR COLONY PINTO PARK MORAR GWALIOR 474005 | GWALIOR | GWALIOR | MP | 474005 | L2 | Rejected-Finance Being not L1 |
| Sl No | Description | Qty | Unit | anand enterprises L1 | M/S AUTOMATION AND SWITCHGEAR CONTROL L2 |
|---|---|---|---|---|---|
| 1.00 | Supply, installation, connecting, commissioning and replacement of LT panel with CPRI approved main factory fabricated LT distribution panel board, outdoor type, both side openable including loking arrangement with sliding door bolt , cubical type, 3 phase, 4 wire, 415V, factory made free standing, floor mounting, dust and vermin proof, cubical type, fabricated from 3.15 mm thick MS sheet with anticorrosive coating and finally epoxy polyster powder coating of flint grey shade fully compartmentalised design with 4Nos insulated bus bar each made of high conductivity aluminium suitable for 1200 Amps, prewired with suitable size of copper cable/insulated copper strip including PCC work height from ground level .9 mtrs and Iron angle work for fixing arragement at site suitable earth strips conforming to IS, cable glands, lugs etc suitable for and comprising of the following including taking down old LT panel:-
(A) INCOMING
(i) ACB, 4 Pole,415V, 50HZ 630 Amps 65 KA Manual Drawout type with microprocessor release -01 Nos
(B) OUTGOING (i) MCCB adjustable thermal and magnetic of 400 Amps, 4pole, 415 Volts, 36 KA, with rotary mechanism - 04 Nos
(ii) MCCB adjustable thermal and magnetic of 250 Amps, 4pole, 415 Volts, 36 KA , with rotary mechanism - 04 Nos
iii) MCCB adjustable thermal and magnetic of 63 Amps, 4pole, 415 Volts, 16 KA , with rotary macanism - 02 Nos
(iv) Blank space for MCCBs of same capacity - 02 Nos
(v) Digital Multifuction meter with selector switch and three current transformers of suitable ratio and capacity -01 Set
(vi) Three phase Amp meter Accuracy Class 1.0, 0.5 Inbuilt selector switch for 3 phase meters CT/PT site programmable Frequency parameter available in 3Ph - 8 Nos
(vii) LED Type Phase indicator lamps for three phases set of three -08 Nos
(viii) Selector switch - 08 Nos
(ix) Busbar chamber having insulated aluminium busbar, each suitable for 1200 Amps for three phases and neutral -01 Set | 1 | Each | 4,50,000 ₹4,50,000 Lowest | 5,50,000 ₹5,50,000 |
| 2.00 | Supply, installation, connecting, commissioning and replacement of LT panel with CPRI approved main factory fabricated LT distribution panel board, outdoor type, both side openable including loking arrangement with sliding door bolt , cubical type, 3 phase, 4 wire, 415V, factory made free standing, floor mounting, dust and vermin proof, cubical type, fabricated from 3.15 mm thick MS sheet with anticorrosive coating and finally epoxy polyster powder coating of flint grey shade fully compartmentalised design with 4Nos insulated bus bar each made of high conductivity aluminium suitable for 720 Amps, prewired with suitable size of copper cable/insulated copper strip including PCC work height from ground level .9 mtrs and Iron angle work for fixing arragement at site suitable earth strips conforming to IS, cable glands, lugs etc suitable for and comprising of the following including taking down old LT panel:-
(A) INCOMING
(i) MCCB, 4 Pole,415V, 50HZ 400 Amps 36 KA adjustable thermal and magnetic with rotary mechanism-01 Nos
(B) OUTGOING (i) MCCB adjustable thermal and magnetic of 250 Amps, 4pole, 415 Volts, 36 KA, with rotary mechanism - 02 Nos
(ii) MCCB adjustable thermal and magnetic of 200 Amps, 4pole, 415 Volts, 16 KA , with rotary mechanism - 02 Nos
(iii) MCCB adjustable thermal and magnetic of 160 Amps, 4pole, 415 Volts, 16 KA , with rotary mechanism - 02 Nos
(iv) MCCB adjustable thermal and magnetic of 100 Amps, 4pole, 415 Volts, 1 KA - 01 Nos
(v) Three pole power contractor MNX-12 -01 Nos
(vi) Three pole power contractor MNX-12 -01 Nos -02 Nos (vii) Three pole power contractor MNX-12 -01 Nos -02 Nos
(viii) Change over switch 400 Amps 4 pole 415 volt with handle - 01 Nos
(ix) MCB SPN 'C' Series,240V/415V,50Hz,32 amps 10 KA-01 Nos
(x) Power factor Controller - 01 Nos (xi) Blank space for MCCBs of same capacity - 01 Nos
(xii) Digital Multifuction meter with selector switch and three current transformers of suitable ratio and capacity -01 Set
(xiii) LED Type Phase indicator lamps for three phases set of three -08 Nos
(Xiv) Selector switch - 08 Nos
(xii) Busbar chamber having insulated aluminium busbar, each suitable for 720 Amps for three phases and neutral -01 Set | 1 | Each | 2,70,000 ₹2,70,000 Lowest | 2,75,000 ₹2,75,000 |
| 3.00 | Supply, installation, connecting, commissioning and replacement of LT panel with CPRI approved main factory fabricated LT distribution panel board, outdoor type, both side openable including loking arrangement with sliding door bolt , cubical type, 3 phase, 4 wire, 415V, factory made free standing, floor mounting, dust and vermin proof, cubical type, fabricated from 3.15 mm thick MS sheet with anticorrosive coating and finally epoxy polyster powder coating of flint grey shade fully compartmentalised design with 4Nos insulated bus bar each made of high conductivity aluminium suitable for 225 Amps, prewired with suitable size of copper cable/insulated copper strip including PCC work height from ground level .9 mtrs and Iron angle work for fixing arragement at site suitable earth strips conforming to IS, cable glands, lugs etc suitable for and comprising of the following including taking down old LT panel:-
(A) INCOMING
(i) MCCB, 4 Pole, 415V, 50HZ,125 Amps 25KA micro processor -01 No.
(B) OUTGOING
(i) MCCB, 4 Pole,415V, 50HZ 63 Amps 16 KA adjustable thermal and magnetic -01 Nos
(ii) MCB, SPN 'C' Series,240V, 50HZ 63 Amps 10KA -02 Nos
(iii) MCB, SPN 'C' Series,240V, 50HZ 32 Amps 10KA -01 Nos (iv) Digital Multifuction meter with selector switch and three current transformers of suitable ratio and capacity -01 Set
(v) LED Type Phase indicator lamps for three phases set of three - 01 set
(vi) Busbar chamber having insulated aluminium busbar, each suitable for 720 Amps for three phases and neutral -01 Set
(vii) Spare space for MCCB of same capacity -01 Nos | 1 | Each Job | 1,00,000 ₹1,00,000 | 95,000 ₹95,000 Lowest |
| 4.00 | M & L for earthing complete with galvanised steel earth plate electrode 60 cm X 60 cm X 6.0 mm burried directly in ground level with top edge of earth plate at a depth not less than 1.5 m below ground level connected to and including galvanised iron strip 32 X 6 mm as earthing lead by means of bolts, nuts, check nuts and washers etc made of GI and connected to earthing test point all as shown in electric plate No. 5 of SSR indicated and testing on completion including excavation and earth work in any type of soil/rock, PCC (1:3:6) type C-1 earthing chamber, cast iron cover with lifting handle, funnel with GI watering pipe of 20 mm bore medium grade, wire mesh and lugs, GI protection pipe of 40 mm bore light grade 7.5 m long test point etc complete including taking down old U/S earthing.
Note :- (i) Cost of earth strip and GI protection pipe up to a distance 7.5 metre shall be included in the quoted rate. (ii )On testing after completion if the desired earth resistance less than 2 ohm is not obtained the earthing will be redone at no extra cost. | 6 | Each | 4,800 ₹28,800 Lowest | 5,000 ₹30,000 |
| 5.00Supply and Laying including jointing and testing electric under ground LT cable XLPE insulated armoured heavy duty aluminium conductor cable 1100 volts grade in trenches , ducts, pipe on walls, poles of following sizes | |||||
| 5.01 | 10 Sqmm 2 core | 105 | RM | 120 ₹12,600 Lowest | 120 ₹12,600 Lowest |
| 5.02 | 150 sqmm 3.5 core. | 100 | RM | 1,000 ₹1,00,000 | 980 ₹98,000 Lowest |
| 5.03 | 240 Sqmm 3.5 core | 50 | RM | 1,300 ₹65,000 Lowest | 1,400 ₹70,000 |
| 5.04 | 400 Sqmm 3.5 core | 50 | RM | 1,750 ₹87,500 Lowest | 2,000 ₹1,00,000 |
| 6.00Taking out existing LT under ground cable 1100 volts grade PVC insulated armoured aluminium conductor from tranches/ducts/pipe, on wall, poles of following size and removing unserviceable cable from site to store :- | |||||
Tender Value
₹11.9 L
EMD Value
₹23,780
Closing Date
7 Apr 2026, 6:00 pmClosed
Harikesh Meena EE
Opp Akashwani, Makarpura road PO-ONGC Baroda-390009
As per BOQ
2026_MES_752616_2
8938
Open Tender
Civil Works
Item Rate
150 days
GE ARMY BARODA
As per tender documents
9 documents required · 9 mandatory
₹500
GE ARMY BARODA
₹23,780
Yes
17 Jun 2026
25 Mar 2026
8 Apr 2026
25 Mar 2026
7 Apr 2026
2 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| - | Supply, installation, connecting, commissioning and replacement of LT panel with CPRI approved main factory fabricated LT distribution panel board, outdoor type, both side openable including loking arrangement with sliding door bolt , cubical type, 3 phase, 4 wire, 415V, factory made free standing, floor mounting, dust and vermin proof, cubical type, fabricated from 3.15 mm thick MS sheet with anticorrosive coating and finally epoxy polyster powder coating of flint grey shade fully compartmentalised design with 4Nos insulated bus bar each made of high conductivity aluminium suitable for 1200 Amps, prewired with suitable size of copper cable/insulated copper strip including PCC work height from ground level .9 mtrs and Iron angle work for fixing arragement at site suitable earth strips conforming to IS, cable glands, lugs etc suitable for and comprising of the following including taking down old LT panel:-
(A) INCOMING
(i) ACB, 4 Pole,415V, 50HZ 630 Amps 65 KA Manual Drawout type with microprocessor release -01 Nos
(B) OUTGOING (i) MCCB adjustable thermal and magnetic of 400 Amps, 4pole, 415 Volts, 36 KA, with rotary mechanism - 04 Nos
(ii) MCCB adjustable thermal and magnetic of 250 Amps, 4pole, 415 Volts, 36 KA , with rotary mechanism - 04 Nos
iii) MCCB adjustable thermal and magnetic of 63 Amps, 4pole, 415 Volts, 16 KA , with rotary macanism - 02 Nos
(iv) Blank space for MCCBs of same capacity - 02 Nos
(v) Digital Multifuction meter with selector switch and three current transformers of suitable ratio and capacity -01 Set
(vi) Three phase Amp meter Accuracy Class 1.0, 0.5 Inbuilt selector switch for 3 phase meters CT/PT site programmable Frequency parameter available in 3Ph - 8 Nos
(vii) LED Type Phase indicator lamps for three phases set of three -08 Nos
(viii) Selector switch - 08 Nos
(ix) Busbar chamber having insulated aluminium busbar, each suitable for 1200 Amps for three phases and neutral -01 Set | - | Each | - | - |
| - | Supply, installation, connecting, commissioning and replacement of LT panel with CPRI approved main factory fabricated LT distribution panel board, outdoor type, both side openable including loking arrangement with sliding door bolt , cubical type, 3 phase, 4 wire, 415V, factory made free standing, floor mounting, dust and vermin proof, cubical type, fabricated from 3.15 mm thick MS sheet with anticorrosive coating and finally epoxy polyster powder coating of flint grey shade fully compartmentalised design with 4Nos insulated bus bar each made of high conductivity aluminium suitable for 720 Amps, prewired with suitable size of copper cable/insulated copper strip including PCC work height from ground level .9 mtrs and Iron angle work for fixing arragement at site suitable earth strips conforming to IS, cable glands, lugs etc suitable for and comprising of the following including taking down old LT panel:-
(A) INCOMING
(i) MCCB, 4 Pole,415V, 50HZ 400 Amps 36 KA adjustable thermal and magnetic with rotary mechanism-01 Nos
(B) OUTGOING (i) MCCB adjustable thermal and magnetic of 250 Amps, 4pole, 415 Volts, 36 KA, with rotary mechanism - 02 Nos
(ii) MCCB adjustable thermal and magnetic of 200 Amps, 4pole, 415 Volts, 16 KA , with rotary mechanism - 02 Nos
(iii) MCCB adjustable thermal and magnetic of 160 Amps, 4pole, 415 Volts, 16 KA , with rotary mechanism - 02 Nos
(iv) MCCB adjustable thermal and magnetic of 100 Amps, 4pole, 415 Volts, 1 KA - 01 Nos
(v) Three pole power contractor MNX-12 -01 Nos
(vi) Three pole power contractor MNX-12 -01 Nos -02 Nos (vii) Three pole power contractor MNX-12 -01 Nos -02 Nos
(viii) Change over switch 400 Amps 4 pole 415 volt with handle - 01 Nos
(ix) MCB SPN 'C' Series,240V/415V,50Hz,32 amps 10 KA-01 Nos
(x) Power factor Controller - 01 Nos (xi) Blank space for MCCBs of same capacity - 01 Nos
(xii) Digital Multifuction meter with selector switch and three current transformers of suitable ratio and capacity -01 Set
(xiii) LED Type Phase indicator lamps for three phases set of three -08 Nos
(Xiv) Selector switch - 08 Nos
(xii) Busbar chamber having insulated aluminium busbar, each suitable for 720 Amps for three phases and neutral -01 Set | - | Each | - | - |
| - | Supply, installation, connecting, commissioning and replacement of LT panel with CPRI approved main factory fabricated LT distribution panel board, outdoor type, both side openable including loking arrangement with sliding door bolt , cubical type, 3 phase, 4 wire, 415V, factory made free standing, floor mounting, dust and vermin proof, cubical type, fabricated from 3.15 mm thick MS sheet with anticorrosive coating and finally epoxy polyster powder coating of flint grey shade fully compartmentalised design with 4Nos insulated bus bar each made of high conductivity aluminium suitable for 225 Amps, prewired with suitable size of copper cable/insulated copper strip including PCC work height from ground level .9 mtrs and Iron angle work for fixing arragement at site suitable earth strips conforming to IS, cable glands, lugs etc suitable for and comprising of the following including taking down old LT panel:-
(A) INCOMING
(i) MCCB, 4 Pole, 415V, 50HZ,125 Amps 25KA micro processor -01 No.
(B) OUTGOING
(i) MCCB, 4 Pole,415V, 50HZ 63 Amps 16 KA adjustable thermal and magnetic -01 Nos
(ii) MCB, SPN 'C' Series,240V, 50HZ 63 Amps 10KA -02 Nos
(iii) MCB, SPN 'C' Series,240V, 50HZ 32 Amps 10KA -01 Nos (iv) Digital Multifuction meter with selector switch and three current transformers of suitable ratio and capacity -01 Set
(v) LED Type Phase indicator lamps for three phases set of three - 01 set
(vi) Busbar chamber having insulated aluminium busbar, each suitable for 720 Amps for three phases and neutral -01 Set
(vii) Spare space for MCCB of same capacity -01 Nos | - | Each Job | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.16 MB
Tenderpages8938.pdf
Tender Documents • 0.42 MB
BOQ_848611.xls
BOQ • 18.74 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .