Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance HOUSE NO 43 SILCHAR HOUSE NO 43 VIVEKANANDA ROAD LANE NO 28 VILLAGE TOWN SILCHAR CITY SILCHAR CACHAR ASSAM 788007 INDIA | CACHAR | ASSAM | 788007 | Admitted-Finance |
| 2 | Rejected-Technical S M C ROAD GHUNGOOR SILCHAR DIST CACHAR ASSAM PIN 788014 | SILCHAR | CACHAR | ASSAM | 788014 | Rejected-Technical BIDDER DID NOT SUBMITTAPDCL EMPANELMENT CERTIFICATE AND WORK EXPERIENCE CERTIFICATE AS PER NIT |
Tender Value
₹34.4 L
EMD Value
₹68,810
Closing Date
16 Jul 2025, 11:00 amClosed
EXECUTIVE ENGINEER
ENGINEERING SECTION ASSAM UNIVERSITY SILCHAR
SITC of 11/0.4KV 500 KVA DTR Copper Wound opposite to Warden Complex at Assam University Silchar.
2025_AUS_868202_1
AU/ENGG/MAINT/ELECT-10/2025
Open Tender
Electrical Works
Works
60 days
ASSAM UNIVERSITY SILCHAR
Please refer Tender documents.
3 documents required · 3 mandatory
₹2,500
Assam University Silchar
₹68,810
ENGINEERING SECTION ASSAM UNIVERSITY SILCHAR
25 Jul 2025
10 Jul 2025
17 Jul 2025
10 Jul 2025
16 Jul 2025
10 Jul 2025
15 Jul 2025
Amount
1C X120sqmm unarmored 1.1 KV grade Al cable
DTR cubical for 500 kVA DTRs comprising of requisite one no TM based MCCB/ACB for incoming and three TM release MCCB/FN for outgoing , Static TVM , CT Vmeter, Ameter, LED pilot lamp indicator complete with bus bar etc.
GI earthing pipe 50mm dia 3m length ,3.15 mm thickness with perforated holes of 15 mm dia at 30 cm interval along the pipe
Supply, installation & testing of G.I. Plate earth station with 600 mmx600 mmx6 mm heavy duty G.I. earth plate with necessary 40 mm dia. G.I. watering pipe with G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mmx40 mm G.I. reducing socket for funnel including locking arrangement with 300 mmx300 mmx6 mm hinged cover C.I. cover plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt .
GI trip 25X3mm for DRT earthing
GI trip 50X6 mm for DRT neutral earthing
11/0.4KV 500 KVA DTR Copper Wound - BIS Level certified
GI Steel Tubular Pole SP-60
ll KV DO Fuse Set 200A Assembly
11 KV 400A GOAB switch cum horn type fuse set
Disc insulator (Poly) 70 KN (T&C)
Pin insulator poly 5 KN
LT pin insulator
LT Guy insulator
LT shackel insulator
GI 11 KV T Cross arm with angle size 50X50X6 mm
GI channel cross arm (100X50X6X2200)mm
GI channel cross arm (100X50X6X2800)mm
GI channel cross arm (100X50X6X3200)mm
LT angle cross arm (40X40X6X500)mm
11Kv 5KA LA (Line type Distribution class)
Transformer oil EHV grade insulating oil
H/W fitting for disc insulator T&C 70kN tension type
LT GI Shackel strap with bolts
DTR fencing as per REC standards specification complete with labour and materials.
Earth filling with river sand including watering leveling compacting grading etc including payment for forest royalty and other duties as per site condition and technical specification.
Grouting and mufflerring of steel tubular pole as per specification and drawing with minimum planting depth of 2.15 mtr
Grouting and mufflerring of 8.5 mtr pole as per specification and drawing with minimum planting depth of 1.5 mtr
Grouting of stay set with PCC and boulder
DTR fencing including all material complete with RCC footing beam ,brick wall etc as per specification Rates include all material and labour.
Transformer pad for 500 KVA distribution transformer complete
Testing of transformer: Testing of transformer performing following test in presence of department representative. (i)Open circuit & short circuit testing to determine transformer losses (ii)Oil die-electric strength test (iii)Winding resistance test complete and as directed by department.
Supplying and erection of L.T. stay set complete (Galvanize with 19mm dia x1.8m long stay rod anchor plate of size 30cm x 30cm x 6.4 mm thimble stay clamps tube buckle (19mmx 60c 7/14 SWG dia G.I stay and strain insulation etc. in cement concrete 1:3:6:(1Cement:3Course sand:6graded stone aggregate 40mm nominal size foundation including excavation and refilling etc. as required and as directed by the department.
Supplying and erection of H.T. stay set complete (Galvanize with 19mm dia x1.8m long stay rod anchor plate of size 30cm x 30cm x6.4 mm thimble stay clamps tube buckle (19mmx 60c 7/3.15 mm dia G.I stay and strain insulation etc. in cement concrete 1:3:6:(1Cement:3Course sand:6graded stone aggregate 40mm nominal size foundation including excavation and refilling etc. as required and as directed by the department.
Supplying and string up of 3 Ph , 3 Wire AAAC/ACSR Racoon conductor in the existing P.S.C./ M.S/ Galvanized pole with binding etc. as required and as directed by the department. Directed by the department.
Any other SOR item based on APDCL SOR 2021-22.
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .