| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹22.9 LAccepted-AOC | 1 | Accepted-AOC Being the lowest bidder. | |
| 2 | 2₹25.4 L+₹2.5 L (11.1%)Rejected-AOC | 2 | Rejected-AOC Being other than the lowest bidder. |
Tender Value
₹34.9 L
EMD Value
₹69,860
Closing Date
23 Aug 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Bareilly
HEADQUARTERS, COMMANDER WORKS ENGINEER, MILITARY ENGINEER SERVICES, STATION ROAD, BAREILLY CANTT, PIN 243001
CA NO. CWE BLY /GE(W)/40 OF 2021-2022 REPAIR/MAINTENANCE OF TRANSFORMER INCL REPLACEMENT OF UNSV PARTS, DEHYDRATION, HT VCBs, OCBs AND CONNECTED WORKS UNDER GE(W) BAREILLY
2021_MES_462822_1
8100/B/680/E8
Open Tender
Civil Works
Item Rate
270 days
Bareilly
Class D Category b(ii) For Unenlisted Contractor - Meeting enlistment criteria of MES with regard to having satisfactory completed requisite value of work, Annual turnover, working capital , etc as mentioned in NIT.
6 documents required · 6 mandatory
₹500
GE(West) Bareilly
₹69,860
Yes
30 Sept 2021
26 Jul 2021
30 Aug 2021
26 Jul 2021
23 Aug 2021
11 Aug 2021
60 days
Amount
Opening up the top cover of transformer and taking out the transformer oil in a separate container after disconnecting the HT/LT side electric connections from both the primary & secondary side of the transformer of any type/description (indoor/out door type) installed on pole/floor, for carrying out necessary repair/rewinding to HT/LT side after shifting the transformer to contractors work shop including taking out complete core assembly, megger testing the defective winding portion/taking out , cleaning the laminated core and rewinding with appropriate gauge/winding wire/strip winding of existing description for transformer of capacity 50 to 100 KVA including assembling & testing on completion & installation the same at the site complete all as specified and directed. Note:- (a) Winding of coil shall be measured and paid seperately under respective item. (b) Transportation charges are deemed to be included in the quoted rate. (c) The cost for the dehyderation of transformer oil if required shall be measured and paid seperately. (d) The cost of insulation material such as paper, cotton tape, latheriod sheet, cork sheet etc are included in the quoted rate. (f) Proper shut down shall be taken by the contractor before execution of the work.
All as above Srl item No -1 here in before but of capacity exceeding 100 KVA and upto 200 KVA.
All as above Srl item No -1 here in before but of capacity exceeding 200 KVA and upto 400 KVA.
M&L for replacement of copper winding wire of any size/description suitable for step down transformer of any capacity, including winding of coil of HT side as per manufacturers design and specification to obtain rated KVA complete all as specified and directed.
All as above Srl item No -4 here in before but for strip winding of LT side
All as above Srl item No -4 here in before but for aluminium strip winding of HT side
All as above Srl item No -4 here in before but for aluminium strip winding of LT side
Shifting only transformer 100KVA to 400 KVA from one location to another location after carefully disconnecting from existing location and connecting at new location complete all as specified and directed Note:- Proper shut down shall be taken by the contractor before execution of the work.
M&L for Replacement of existing defective HT tap changer of suitable size with tapping arrangement 2.5% to 7.5% and one normal tapping including connecting up with HT coil and testing of transformer for capacity from 50 KVA to 200 KVA complete all as specified and directed .
All as above Srl item No 9 here in before but for capacity above 200KVA and upto 400 KVA
M&L for Replacement of synthetic rubberised cork sheet gasket, 1/4" thick suitable for main body top cover of transformer of capacity up to 500 KVA complete all as specified and directed.
M&L for air breather assembly complete with fresh blue colour silica gel suitable for indoor/outdoor transformer capacity upto 200 KVA connected to air column with conservator tank complete all as specified and as directed.
All as above Srl item No -12 here in before but for capacity above 200KVA and upto 400 KVA
S&F in replacement transformer oil temperature gauge 0 - 100, graduated, analogue dial type complete all as specified and directed.
M&L for dismantling and opening transformer tank cover, removing of worn out transformer oil tank gasket and supply, fix new rubberised gasket sheet 6.0 mm thick using gasket adhesive for the following capacities of transformers including refixing the top cover with conservator tank for transformer capacity 50 to 200 KVA complete all as specified and directed.
All as above Srl item No 15 here-in-before but for transformer of capacity exceeding 200 to 400 KVA complete all as specified and directed.
S&F in replacement HT porcelain bushing (set of three) of suitable size for transformer upto 250 KVA including nuts, bolts & washers complete all as specified and directed.
S&F in replacement of HT porcelain bushing (set of three) of suitable size for transformer above 250KVA and upto 400 KVA including nuts, bolts & washers complete all as specified and directed.
S&F in replacement LT porcelain bushing (set of four) of suitable size for transformer upto 250 KVA including nuts, bolts & washers complete all as specified and directed.
S&F in replacement LT porcelain bushing (set of four) of suitable size for transformer above 250KVA and upto 400 KVA including washers nuts, bolts & complete all as specified and directed.
S&F in replacement HT bush rod (set of three) made out of copper with brass nuts and washers of required length including connecting up with HT coil of transformer upto 200 KVA capacity complete all as specified and directed.
S&F in repairs HT bush rod (set of three) made out of copper with brass nuts and washers of required length including connecting up with HT coil of transformer above 200KVA and upto 400 KVA capacity complete all as specified and directed.
S&F in repairs LT bush rod (set of four) made out of copper with brass nuts and washers of required length including connecting up with LT coil of transformer upto 200 KVA capacity complete all as specified and directed.
S&F in repairs LT bush rod (set of four) made out of copper with brass nuts and washers of required length including connecting up with LT coil of transformer above 200KVA and upto 400 KVA capacity complete all as specified and directed.
S & F rubber seal for transformer HT/LT studs complete for any capacity of transformer complete all as specified and directed.
Supply and filling in replacement of silica gel inside the breather assembly and fixing properly with transformer complete all as specified and directed.
M&L for cutting worn out aluminium cable terminal lugs from the LT cable of size 120 to 300 Sqmm and S&F of new aluminium cable lugs of suitable size and reconnecting the cable with transfrormer, terminal stud including dressing of cable, excavation & surface dressing after providing sand cushioning and brick protection to match with the existing complete all as specified and directed.
M&L for Dehydration and filtering the transformer oil with dehydration machine to achive required di-electric strength of the oil up to 40 KV at 2.5 mm gap complete all as specified and directed. Note 1 :- Dehydration machine and other required equipments shall be arranged by the contractor and no extra cost shall be paid to the contractor on this effect. Note2 : BDV Test certificate shall be submitted by contractor after dehydration.
Supply and filling transformer oil for topping up the level of oil having dielectric strength 60 KV during filling after initial filtration, Make -:POWER/ INSOLE/ UNIVERSAL conforming to relevant IS-335 (Transformer oil shall be supplied in sealed container).
M&L for cleaning sprinkled transformer oil, grease and all other foregin materials from external surfaces of transformer (indoor/outdoor) of capacity upto 200 KVA and preparing the surfaces to receive paint and applying one coat of synthetic enamel paint by using spray gun paint including writing SM/MES Number and SM Number with white paint over black base in letters not less than 10cms in height complete all as specified and directed. Note (a) Painting & cleaning carried out at the existing location of transformer. (b) Proper shut down shall be taken by the contractor before execution of the work.
All as above Srl item No 30 here-in-before but for transformer exceeding 200 to 400 KVA capacity complete all as specified and directed.
M&L for construction brick masonry platform for mounting transformer of 200 KVA to 400 KVA capacity of overall finish size 3mx3mx1.25 mtr high above ground level with sub class 'B' bricks wall 230mm in CM 1:4 PCC 1:4:8 type D2 (using 40mm graded stone agregate) top of the platform finished even and fair without using extra cement including necessary form work, excavation in soft/loose soil, returning filling in and removal of surplus soil to a distance not exceeding 50 mtr and rendering 10 mm thick in CM 1:4 on all exposed vertical surfaces of platform wtih MS angle iron frame 50x50x6mm as in posts at an interval 1.2 mtr centre to centre and 2.25 mtr height duly grouted in PCC 1:3:6 type C-2 (using 40mm aggregate stone and painted with two coats of synthetic enamel paint over a coat of red oxide primer) alongwith 3 Nos Steps, complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 60cmx60cmx 3.15mm thick buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meter below normal ground level connected to galvanised iron strip 32x6 mm by means of bolts, nuts, check nuts and brass washer all as shown in electrical plate No 03 of SSR Part-I connected to continuous earth wire on pole all as specified and testing on completion, including provision of earth strip protected by 40mm dia GI light grade protection pipe from earthing plate to main board and 20mm GI medium grade watering pipe funnel, PCC earth pit and RCC cover charcoal, salt and GI wire including excavation and earth work in any type of strata & testing complete all as specified and directed.
S&F galvanised iron strip of size 32x6mm as earth continuity conductor provided in between earth test point terminal and upto the equipment including nuts, bolts & washers complete all as specified and directed.
S&F in replacement Cable end termination 11 KV HT (heat shrinkable) cable jointing kit for 11 KV ( Earthed) grade cable for indoor/outdoor termination, heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sq mm complete all as specified and directed.
S&F in replacement Cable end termination 11 KV HT (heat shrinkable) cable jointing kit for 11 KV ( Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 Sq mm complete all as specified and directed.
S&F in repair straight through 11 KV HT (heat shirnkable) cable jointing kit for 11 KV ( Earthed) grade cable straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 Sq mm complete all as specified and directed.
S&F in repair straight through 11 KV HT (heat shrinkable) cable jointing kit for 11 KV ( Earthed) grade cable straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sq mm complete all as specified and directed.
Maintenance and complete overhauling of 11 KV VCB of existing make/type/make/capacity including disassembling operating mechanism parts, well cleaning with petrol and CRC-226 and replacing unserviceable spare parts, reassembling of parts including well cleaning the complete panel board, main bus bar, decarbonizing all joints, bus bar, CTs, PTs spout metal parts and making VCB perfect operating in manual and electric mode and calibration and checking of tripping system of 11 KV circuit breaker through IDMT over current and earth fault relay and plug setting infected in service by primary current injection method to ensure proper function of trip coil control circuit etc, during fault condition setting by expert complete all as specified and directed. Note:- Spare parts required to make VCB functional shall be measured and paid separately under respective items.
Supply only the following spare parts of HT 11 KV VCB for replacement against item No. 39 above. (Spares shall be as approved by GE) complete all as specified and directed.
Bakelite Sheet
Shunt Tripping coil 30V DC
Ammeter 0/20 to 100/200 Amp analog type 145 x 145.
Vaccum interupter for indoor VCB
Spout incomming side to match with the existing
Spout outgoing side to match with the existing
Volt meter 0 to 15 KV digital type.
Breaker control switch 10A, 660V
Electronic hooter 40v DC 96 x 96mm
Push button Actuators with carrier & contact element- non -illuminated flush spring return push button with 1 NO block, 22mm dia Red colour
Push button Actuators with carrier & contact element- non -illuminated flush spring return push button with 1 NC block, 22mm dia Green colour.
Integrated LED pilot lamp suitable for operating at 24/110V (AC/DC) set of five (Red, Yelow, Blue, Green & White colour).
Toggle switch assembly
Fuse holders for british pattern fuse links as per IS,13703 2A
Fuse holders for british pattern fuse links as per IS,13703 5A
No volt coil 30 V DC
Copper bus bar of existing size
Spring charging gear to match with existing
S&F in reapir strip type heater 40/60 watt approx 4"/6" in length complete all as specified and directed
Spring charging motor to match with existing
Closing coil to match with existing 30/110 Volt
No volt coil to match with existing
Maintenance and complete overhauling of 11 KV , Oil circuit breaker of existing make/ type/model/capacity including disassembling of operating mechanism parts, well cleaning with petrol and CRC-226 and replacing unserviceable parts, and accessories, oiling / greasing of moving parts includng reassembling fine setting of mechanism removing of oil tank well cleaning and decarbonization of arc control pot fixed and moving contacts ,hinges contacts and repacement of unserviceable parts insulating oil and reassembling and making OCB in perfect operation in manual and electrical mode including well cleaning the complete panel board, main busbar, carbonizing all joints,busbar CTs,PTs, spouts metal parts and components etc and calibration & checking of tripping system of 11 KV circuit breaker through IDMT over current and earth fault relay at plug setting infented in service by primary current injection method to ensure proper function of relays trip coil control circuit etc. during fault condition setting by expert complete all as specified and directed.Note:- Spare parts required to make OCB functional will be measured and paid separately under respective items.
Supply only the following spare parts of HT 11 KV OCB for replacement against Srl item No 41 above as approved and directed:-
Push botton with NO coil, 22mm dia Red colour
Push botton with NO coil, 22mm dia Black colour
LED type indicator lamp assembly Red colour
LED type indicator lamp assembly Green colour
Toggle switch assembly
Moving Contact to match with existing size.
Fixed Contact block Assembly.
Shunt trip assembly (30/110 Volt DC)
Spout of 11 KV HT OCB to match with existing.
Terminal Bushing
Finger of 11 KV HT OCB to match with existing
Tulip Contact
Side Plate RH & LH to match with existing
Arc control Pot with Diaphragm
Tank Liner
Trip Bar
Bakelite Housing
S&F in replacement latest electronic over current and earth fault relay three phase, 03 OC and 1 EF, auxillary supply as per existing DC supply with 2 No + 2 NC contact suitable for SCADA compatible 11 KV VCB/OCB complete all as specified and directed.
M&L for repairing of 11 KV indoor PT with replacement of all damaged parts all male and female spouts and SRC fuses complete all as specified and directed.
S&F in replacement phase barriors support including brass bolt/washer for holding copper bus bar in the HT panel of existing type/size/capacity complete all as specified and directed.
M&L for painting the external /Internal exposed surfaces of HT Panels and connected accessories with one coat of red oxide primer and two coats of enamel paint including preparation of old painted surfaces and writing the details of HT panels complete all as specified and directed.
M&L for hiring of cable fault locator machine for HT cables working voltage upto 11 KV to find out the fault in underground trench at different location up to 500 RM after locating fault and jointing and testing the cable complete all as specified and directed. Note : (a) Excavation and earth work & Joints will be measured and paid separtely under relevant item. (b) If the complaint is not attended within one hour contractor shall be liable to pay a penalty of Rs 1000/- per Hour per complaint.
Taking down existing damaged/unsv/faulty PVC insulated, armoured, aluminium conductor 11000V grade cable of any size and core from trenches, pipe, ducts, pole etc, testing for serviceability of cable, cutting and segregating serviceable portion for relaying serviceable cable where directed complete all as specified and directed. Note: Excavation, earthwork, sand cushioning and cable protection shall be measured and paid separately.
Supply, lay, connect, test and commissioning XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11 KV grade earthed laid in trenches/ducts/encased in GI pipe/fixed to pole including jointing and testing of size 95 sqmm 3 core complete all as specified and directed.
Supply, lay, connect, test and commissioning XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11 KV grade earthed laid in trenches/ducts/encased in GI pipe/fixed to pole including jointing and testing of size 120 sqmm 3 core complete all as specified and directed. Note: For item No 49 & 50. Excavation, earthwork, sand cushioning and cable protection shall be measured and paid separately.
Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth for foundation etc. or for manholes, cesspits, shafts,UG cables etc. not exc. 10 Sqm on plan and getting out in soft/ loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick in each layer as in soil complete all as specified and directed.
Removing excavated soil to distance n.exc. 50m and depositing where directed at a level not exc. 1.50 m above the starting point complete all as specified and directed.
M & L for river washed and screened dry sand for filling in trench below and around the under ground cable for cushoining of cable including necessary punning complete all as specified and directed.Note:- For measurement purpose the punned down thickness of 18 cm only shall be considered.
Supply and laying un-reinforced precast concrete cable cover class HVP type I flat of size 300mm x 180mm x 40mm complete all as specified and directed.
M& L for Boring holes under road or cutting the road /pavement /hard standing or any other situation by mechanical or other means for inserting 25 to 40mm bore GI pipe for crossing the cable and making good both the ends complete all as specified and directed.
S&F in repair 100 mm nominal bore Mild steel galvanised water tubing , light grade ,with all fittings & fixed for road crossing/on wall/floor & as directed.
M & L for earthing complete, chemical type with copper earth plate electrode 900mmx600mmx5mm thick buried directly in ground (earth pit not less than 3 mtr deep 1.5 mtr width ) with top edge of the plate not less than 2.25 mtr below normal ground level connected and including copper strip earth lead 32mm x 6 mm size by means of copper brazing strip and layers of salt charcol and magnesium sulphate including funnel with wire mesh including testing of earthing complete all as specified and directed . (Minimum three chemical pits are to be made and connected in a grid to meet the earth resistance specifications of <0.50 Ohm). (a) Earthing to be done in presence of JE/Engr- in - Charge . (b) Charcoal small pieces 250 Kg , Salt (crystal)-250 Kg , Magnesium Sulphate (Crystal) 100 Kg. (c) Copper strip shall be brazed with copper elctrode plate . (d) Alternate layer of charcoal and salt should be laid in the earth pit on the top of the copper plate at least 5 layers should be laid. (e) After laying of the 5 alternate layers of charcoal and salt a two inch layer of magnesium sulphate to be laid. (f) The chemical salt and and magnesium sulphate should not be fixed but are to be laid in layers only. (g) Copper strip is to be extended inside the equipment and power room. It should be routed in the side wall of the under ground ducts fixed with ceramic /porcelain spacers. (h) Contractor shall pour sufficient water in earth pit before and after doing earthing. (j) 25 mm dia GI pipe light grade of suitable length to reach just above copper plate fitted with funnel meshed along with cap running with water tap to be provided for keeping soil wet. (k) Soft soil ( Black cotton soil) shall be used in case of rocky terrain. (i) Brass nuts and bolts with proper washer to be used for copper strip jointing and necessary brazing shall be done as directed. (m) Copper strip beyond 7.5 m shall be measured and paid seperately. (n) The test point of each pit shall be made as directed and the cost is same is deemed to be included in the qouted rate. (o) The test report should be submitted in triplicate. ( p) Construction of earth pit chamber with PCC (1.3.6) type C1 ( using 20mm gradeed stone aggregates) RCC 1.2.4 type B1 cover 50mm thick with 8mm dia TMT bars @ 100mm centre to centre with igting handles of suitable dia complete all as directed . Note: Earth resistance shall be less than 1.00 Ohms.
Dismantling air break gang operated switches vertical / horizontal mounted including insulators and operating mechanism for repair/ replacement of broken/worn out components and insulators etc complete all as specfied and directed.
Supply install testing and commissioning of Air-break, gang operated, triple pole switch, outdoor, vertical mounting type (ISI marked), mechanically operated, mounted on insulators 12 Nos including 400 Amp rating complete with (DO Fuse unit) fuse mounts, fuse carriers and HT fuse elements and frame work with operating mechanism worked from ground level, with locking arrnagments including Godrej pattern 65mm pad locks with two keys, complete suitable for HT 11 KV, 50 Hz AC supply including necessary electric connections, complete all as specified and directed
M&L for spraying chemical (Round up) on area to remove unwanted vegetation /grass at E/M installations/2pole/4pole structure complete all as specified and directed.
Dismantling posts or struts (wood, steel or RCC) any section including taking out embedded portion in concrete brick work, masonary etc and making good disturbed ground in concrete brick work masonary etc complete all as specified and directed.
Supply and fix mild steel angle iron post and struts in fencing incl cutting tops to shape as directed ,drilling holes,notching for wire etc complete all as specified.
M & L for PCC 1:4:8 mix, Type D2 (using 40mm graded stone aggregates) as in foundations, filling and mass concrete complete all as specified and as directed by the Engineer-in-Charge.
M&L for TMT bars ,10mm dia and over, cut to length bent to shape required including cranking bending spirally for hoping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
Dismantling fencing wire mesh any type complete all as specified and directed.
Fixing only chain link fencing including line wires any mesh size and type to any type of standards rails, straining bolts, etc including provision of binding wire complete all as specified and directed.
Supply only GI chain link fencing size of mesh (50x50mm) dia of mesh 4mm etc & fixed to angle iron post complete all as specified.
M&L for painting steel surfaces of any description exceeding 10cm width or girth with two coats of aluminium paint over a coat of red oxide primer including preparation of new or previously untreated surfaces complete all as specified and directed.
M&L for disconnecting the input and output electric supply from automatic voltage stablizer upto 100 KVA capacity and taking out from site and shifting to civil workshop for carrying out repair works including servicing of dimmer and gears and refixing the same after repair complete all as specified and directed. Note:- The rate quoted by the contractor shall include the rate of T&P, transportation and necessary man power required during loading and unloading.
Opening the top cover of voltage stablizer taking out the complete servo stablizer oil and keep it for reuse and taking out dimmer assembly and transformer assembly for checking the defects and carrying necessary repair work complete all as specified and directed.
S&F in replacement copper wound dimmer state unit of capacity 100KVA servo voltage stablizer complete all as specified and directed
S&F in replacement electronic cards including replacement of all worn out parts complete all as specified and directed.:-
Servo motor complete with RC network
Micro switch
RC Network for motor
Carbon bushes
Supply and laying graded stone aggregates for loose filling of gauge 40mm to 80mm complete all as specified and directed.
Supply only HT aluminium lugs of size 95 sqmm
Supply only HT aluminium lugs of size 120 sqmm
Note : Tenderers may note that amount of credit Rs 354860.00 will be deducted from the total amount arrived, at the time of Acceptance of contract.
M/S HINA ELECTRICALS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .