Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.5 CrAccepted-AOC MANATHA ENCLAVE 3RD FLOOR OLIMUGAL KAKKANAD P O KOCHI 682 030 KERALA | ERNAKULAM | KERALA | 682030 | ₹8.5 Cr | L1 | Accepted-AOC ACCEPT BEING L1 |
| 2 | L2₹9.6 Cr+₹1.1 Cr (13.4%)Rejected-Finance GP KIZHAKKAMBALAM KOLENCHERY | THRISSUR | KERALA | 680667 | ₹9.6 Cr+₹1.1 Cr (13.4%) | L2 | Rejected-Finance REJECT BEING L2 |
| 3 | L3₹9.9 Cr+₹1.5 Cr (17.3%)Rejected-Finance BLDG NO 22 2079 COAST GUARD ROAD NEAR COAST GUARD FAMILY ACCOMMODATION MUNDAMVELI PO PALLURUTHY VII ERNAKULAM 682 507 | ERNAKULAM | ERNAKULAM | KERALA | 682507 | ₹9.9 Cr+₹1.5 Cr (17.3%) | L3 | Rejected-Finance REJECT BEING L3 |
| 4 | L4₹10.1 Cr+₹1.7 Cr (19.9%)Rejected-Finance THOTTAPPALLY HOUSE EMILY KALPETTA P O KERALA 673121 | WAYANAD | KERALA | 673121 | ₹10.1 Cr+₹1.7 Cr (19.9%) | L4 | Rejected-Finance REJECT BEING L4 |
Tender Value
Refer Docs
EMD Value
₹7.8 L
Closing Date
12 Jun 2023, 6:00 pmClosed
CE NW KOCHI
CE NW KOCHI, KATARIBAGH, NAVAL BASE PO-682004
PROVISION OF DEFICIENT TOWER FOR ANTENNA OF ASR RADAR AT INS GARUDA KOCHI
2023_MES_582291_3
891021/E8
Open Tender
Civil Works
Lump-sum
540 days
KOCHI
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹3,000
GE P KOCHI
₹7.8 L
Yes
18 Aug 2023
20 May 2023
14 Jun 2023
20 May 2023
12 Jun 2023
28 May 2023
Amount
Total amount of Sch 'A' Part-I (BUILDINGS/STRUCTURES)
Total amount of Sch 'A' Part-II (EARTHWORK, SITE CLEARANCE & DEVELOPMENT)
Total amount of Sch 'A' Part-III (INTERNAL ELECTRIFICATION)
Total amount of Sch 'A' Part-IV (INTERNAL WATER SUPPLY)
Total amount of Sch 'A' Part-V (EXTERNAL WATER SUPPLY)
Total amount of Sch 'A' Part-VI (EXTERNAL ELECTRIFICATION AND STANDBY DG SUPPLY)
Total amount of Sch 'A' Part-VII (LIGHTNING PROTECTION)
Total amount of Sch 'A' Part-VIII (FIRE ALARM SYSTEM AND WIRE ROPE ELECTRIC HOIST)
Total amount of Sch 'A' Part-IX (ROAD/ PATH/ HARD STANDING)
Total amount of Sch 'A' Part-X (SEWAGE DISPOSAL)
Total amount of Sch 'A' Part-XI (AREA DRAINAGE)
Sch 'A' Part- XII (MISCELLANEOUS ITEMS) (Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.)
PILE FOUNDATION:
Boring for cast-in-situ bored piles of 1000mm dia to any depth through any type of soil/strata by DMC method using bentonite slurry including removal of bored materials to place outside MD land all as specified and as directed. Note:- The rate shall include mobilisation, erection, dismantling and demobilisation of equipment for pile boring including all labours and material. Nothing extra shall be payable for mobilisation of equipment seperately.
Boring for cast-in-situ under-reamed piles with two bulbs of 500mm dia to any depth through any type of soil/strata by DMC method using bentonite slurry including removal of bored materials to place outside MD land all as specified and as directed. Note:- The rate shall include mobilisation, erection, dismantling and demobilisation of equipment for pile boring including all labours and material. Nothing extra shall be payable for mobilisation of equipment seperately.
RCC with ready mix concrete grade M-30 design mix as per IS-456 with min 400Kg cement per cum of any length /any sections in cast in situ bored pile complete all as specified and as shown on drg including non destructive integrity test on all pile as per IS 2911 part IV complete all as shown on drawing and as specified and directed. Note:- (i)The unit rate quoted under this item is deemed to be inclusive of charges for non destructive test (ii)Reinforcement will be measured and paid separately under relevant items
RCC with ready mix concrete grade M-30 design mix as per IS-456 with min 400Kg cement per cum of any length /any sections in cast in situ under-reamed pile complete all as specified and as shown on drg including non destructive integrity test on all pile as per IS 2911 part IV complete all as shown on drawing and as specified and directed. Note:- (i)The unit rate quoted under this item is deemed to be inclusive of charges for non destructive test (ii)Reinforcement will be measured and paid separately under relevant items
RCC with Ready Mix Concrete(RMC) M30 grade in pile cap, grade beam/ tie beam of any length/section including test pile complete all as specified and shown on drg. Note :- Reinforcement will be measured and paid for separately under relevant items of this Schedule.
CRS/HCRS/CRM TMT bars in reinforcement 10mm dia and over including cut to length, bend to required shape, cranking/hooking ends if necessary and binding with 0.9mm dia MS wire annealed or welding so as to secure the bar firmly in position/required shape complete all as specified and shown on drgs as in Piles.
CRS/HCRS/CRM TMT bars in reinforcement 10mm dia and over including cut to length, bend to required shape, cranking/hooking ends if necessary and binding with 0.9mm dia MS wire annealed or welding so as to secure the bar firmly in position/required shape complete all as specified and shown on drgs as for Grade beams/tie beams and pile caps.
CRS/HCRS/CRM TMT bars 5mm to 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality complete all as specified and shown on drgs as in Helicals for piles.
CRS/HCRS/CRM TMT bars in reinforcement 10mm dia and over for Ring/Stiffener for piles including cut to length, bend to required shape, cranking/hooking ends if necessary and binding with 0.9mm dia MS wire annealed or welding so as to secure the bar firmly in position/required shape complete all as specified and shown on drgs .
CRS/HCRS/CRM TMT bars 5mm to 10mm dia and over including 12mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality complete all as specified and shown on drgs as in raft foundation/pile cap stirrups.
Providing testing equipment & load and testing of 1000mm dia bored pile (Initial Load test) all as per IS IS 2911 part IV Cl 5.1.1 including removing the testing equipments from site after testing is completed all as specified and directed.
Providing testing equipment & load and testing of 500mm dia bored pile (Initial Load test) all as per IS IS 2911 part IV Cl 5.1.1 including removing the testing equipments from site after testing is completed all as specified and directed.
Providing testing equipment & load and testing of 1000mm dia bored pile (Routine Load test) all as per IS including removing the testing equipments from site after testing is completed all as specified and directed.
Providing testing equipment & load and testing of 500mm dia bored pile (Routine Load test) all as per IS including removing the testing equipments from site after testing is completed all as specified and directed.
Conducting standard penetration test all as per IS-2131 at levels and locations as directed for 1000mm dia cast in situ bored piles all as specified and as directed.
Conducting standard penetration test all as per IS-2131 at levels and locations as directed for 500mm dia cast in situ bored piles all as specified and as directed.
Plain Cement Concrete (1:4:8) type D2 using 40mm graded stone aggregate for concrete layer below pile caps/ grade beams and foundation complete all as specified and shown on drgs.
Formwork to sides of pile caps, grade beams and tie beams for rough finished flat concrete surfaces all as specified .
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m deep or area not exceeding 10 sqm on plan in any type of soil including bailing out/pumping out water on account of spring/rain or any other causes using any method as required and as directed by Engr-in-Charge for pile caps/grade beams etc all as specified and shown on drawings.
Excavation over areas 1.5m deep and not exceeding 3m deep in any type of soil including bailing out/pumping out water on account of spring/rain or any other causes using any method as required and as directed by Engr-in-Charge for pile caps/grade beams/ raft foundation etc all as specified and shown on drawings.
Excavation over areas exceeding 3.0m deep and not exceeding 4.5m deep in any type of soil including bailing out/pumping out water on account of spring/rain or any other causes using any method as required and as directed by Engr-in-Charge for pile caps/grade beams/ raft foundation etc all as specified and shown on drawings.
Returning filling in around pile cap, plinth beams, raft foundation etc using excavated soil including spreading levelling and well ramming in layers not exc 25 cm thick complete all as specified and as directed.
Removal of surplus soil to a distance exceeding 50m and not exc. 100m deposited as directed.
INTERNAL ELECTRIFICATION:
Material and Labour for Point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), with multi-stranded copper conductor 1.5 Sq. mm nominal cross-sectional area, single core, PVC insulated and sheathed FRLS cable 1100 volts grade, ISI-694 marked including heavy duty PVC concealed conduit and conduit accessories concealed in wall/roof/floor etc, ISI marked including modular GI flush box of suitable size with inner and outer white plastic plate (Same make of approved switch and socket) including PVC insulated multi-stranded copper conductor 1.5 Sqmm nominal cross sectional area single core F.R.L.S. cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed at site for the following:-
One light point controlled by one 5/6 amps one way switch.
One light point controlled by one 5/6 amps two way switch.
One Ceiling fan point controlled by one 5/6 amps one way switch.
One exhaust fan point controlled by one 5/6 amps one way switch.
One Socket outlet, three/five pin, 5 Amp, independent controlled by one 5/6 amps one way switch or switch/ socket combination 5 amps, 5 pin.
All as per item No 38 above but with 2.5 sqmm copper conductor including 2.5 sqmm copper cable as earth wire for One Socket outlet, three/five pin, 15 Amp, independent controlled by one 15/16 amps one way switch or switch/socket combination 15 amps, 5 pin complete all as specified and as directed.
Supply and fixing ceiling fan complete with blade, down rods and accessories, 230 V, 1200mm sweep copper wound having Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) as per IS 374:2019 including fixing of down rod and connecting up complete with and including three core flexible PVC insulated multi stranded copper conductor cable of size 0.5 Sq mm from connector to fan complete all as specified and as directed.
Supply and fix exhaust fan steel body AC single phase 230V, 50 Hz, RPM 1200 of size 300mm sweep with blades and frame and louvers complete including making necessary provisions for mounting on walls complete all as specified and as directed.
Supply and fixing LED lights fitting 1x 22W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete and including connecting 3 core 1sqmm PVC insulated multistranded copper conductor's sleeve color matching to fitting and connecting up complete all as specified and directed.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete and including connecting 3 core 1.0 Sqmm PVC insulated multistranded copper conductor color of sleeve matching to fitting and connecting up complete all as specified and directed.
Supply and fixing building LED security light 1x35W new generation energy saving and environmental friendly long life made of pressure die cast alluminium housing with hogh power LED as lighting source and lens embded PC cover having TOP OPENING seperade driver compartment with IP66 protection and impact resistance of IK 07 complete with and including wall mounted bracket fabricated out of 40mm GI pipe light grade bend to shape1.5 mtr long and two nos wall mounting clamps using 25x4mm thick MS strip bend to shape and welded with pipe to form solid structure and one run of 1sqmm PVC insulated multistranded copper conductor wire conecting pvc terminal to fitting complete all as specified and directed.
Supply and fixing Recess mounted commercial luminaire 36 watt, 50 Hz, 220 volts, 5700 Kd down lighter 2' x 2' including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete and including connecting 3 core 1sqmm PVC insulated multistranded copper conductor's sleeve color matching to fitting and connecting up complete all as specified and directed. Make Philips cat Part No RC383B-LED 36S-6500 PSU OD WH PIR or equivalents as given in approved makes
Supply and fix MCCB DB VTPN 4 way double door 415 Volts with provision for MCCB as incomer and SP/TP MCBs as out going with IP 43 protection, door earthing, isolated neutral bar, mechanical impact strength IK 09 including cement spill protector complete all as specified and as directed. Make Legrand Cat No 5077 45 or equivalents as given in approved makes
Supply and fixing Sheet metal enclosure distribution board MCB DB TPN 6 way with metal double door 240 Volts with IP-43 protection including door earthing complete all as specified and as directed.
Supply and fixing Sheet metal enclosure distribution board MCB DB TPN 4 way with metal double door 240 Volts with IP-43 protection including door earthing complete all as specified and as directed.
Supply and fixing Sheet metal enclosure distribution board MCB DB SPN 8 way with metal double door 240 Volts with IP-43 protection including door earthing complete all as specified and as directed.
Supply and fixing Sheet metal enclosure distribution board MCB DB SPN 7 way with metal double door 240 Volts with IP-43 protection including door earthing complete all as specified and as directed.
Supply and fixing MCCB 4 pole of current rating capacity 100 Amps with breaking capacity Icu AC 25kA @ 415V AC 50 Hz conforming to IS/IEC 60947-2 & EN 60947-2 of thermal magnetic release with ON-TRIP-OFF indication complete all as specified and as directed. Make Legrand Cat No 420054 or equivalents as given in approved makes
Supply and fixing MCCB 4 pole of current rating capacity 63 Amps with breaking capacity Icu AC 25kA @ 415V AC 50 Hz conforming to IS/IEC 60947-2 & EN 60947-2 of thermal magnetic release with ON-TRIP-OFF indication complete all as specified and as directed. Make Legrand Cat No 420053 or equivalents as given in approved makes
Supply and fixing MCCB 4 pole of current rating capacity 40 Amps with breaking capacity Icu AC 25kA @ 415V AC 50 Hz conforming to IS/IEC 60947-2 & EN 60947-2 of thermal magnetic release with ON-TRIP-OFF indication complete all as specified and as directed. Make Legrand Cat No 420052 or equivalents as given in approved makes
Supply and fixing TPN 40 to 100 AMP 415V 10KA 'C' curve miniature circuit breaker (MCB) 4 poles and current carrying capacity in the DB complete with connection testing and commissioning all as specified and as directed.
Supply and fixing TPN 32 AMP 415V 10KA 'C' curve miniature circuit breaker (MCB) 4 poles and current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and as directed.
Supply and fixing TPN 25 AMP 415V 10KA 'C' curve miniature circuit breaker (MCB) 3 poles and current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and as directed.
Supply and fixing MCB SPN 32 Amps 10 kA with charaterestic "C" Curve complete all as specified and as directed.
Supply and fixing MCB SP 06-32 Amps 10 kA with characteristic "C" curve conforming to IS/IEC 60898 complete all as specified and as directed.
Material and labour submain wiring with 2 single core 4 sqmm PVC insulated unsheathed multistranded copper conductor cable 1100 volts grade drawn through and including PVC rigid conduit concealed wiring including necessary PVC conduit specials including chases cutting complete exceapt beam and RCC roof and one run of 4 sqmm PVC insulated unsheathedv single core 1100 volts grade multistranded copper conductor cable as earth continuity conductor and connecting with suitable size thimble complete all as specified and as directed. Note : Three run of 4 sqmm size PVC cable and one run of PVC conduit shall be measured as one unit length.
Material and labour submain wiring with 2 single core 6 sqmm PVC insulated unsheathed multistranded copper conductor cable 1100 volts grade drawn through and including PVC rigid conduit concealed wiring including necessary PVC conduit specials including chases cutting complete exceapt beam and RCC roof and one run of 6 sqmm PVC insulated unsheathedv single core 1100 volts grade multistranded copper conductor cable as earth continuity conductor and connecting with suitable size thimble complete all as specified and as directed. Note : Three run of 6 sqmm size PVC cable and one run of PVC conduit shall be measured as one unit length.
Material and labour submain wiring with 4 single core 6 sqmm PVC insulated unsheathed multistranded copper conductor cable 1100 volts grade drawn through and including PVC rigid conduit concealed wiring including necessary PVC conduit specials including chases cutting complete exceapt beam and RCC roof and one run of 6 sqmm PVC insulated unsheathedv single core 1100 volts grade multistranded copper conductor cable as earth continuity conductor and connecting with suitable size thimble complete all as specified and as directed. Note : Five run of 6 sqmm size PVC cable and one run of PVC conduit shall be measured as one unit length.
Material and labour XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 sq. mm 4 core in wall /duct complete all as specified and as directed.
Material and labour XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 sq. mm 4 core in wall /duct complete all as specified and as directed.
Supply and fix Triple pole enclosure with three pin earth and earth plug and socket complete with one TP MCB 20 amps having breaking capacity 10 kA complete all as specified and as directed.
Supply and fix SPN pole enclosure with two pin earth and earth plug and socket complete with one SP MCB 20 amps having breaking capacity 10 kA complete all as specified and as directed.
Supply and fix LED light fitting 1x9W/ 1X10W bulk head luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
INTERNAL WATER SUPPLY:
Supply and Fix 15mm dia Bib tap with crutch or butterfly handle, screwed down, screwed for iron pipe, fancy type, cast copper alloy, chromium plated with flange complete all as specified and as directed. Make: CERA Cat No. F3002151 or equivalent as listed in approved makes
Supply and Fixing in angular stop cock 15 mm bore of cast copper alloy Chromium plated with wall flange screwed down high pressure with crutch or butter fly handle screwed both ends for CPVC pipe complete all as specified and as directed. Make: Jaquar Cat Part No. SOL-CHR-6053 or equivalent in approved list of makes
Supply and fix mild steel with chromium plated health faucet with 8 mm dia, 1.25 mtr long flexible tube & wall hook complete all as specified and as directed. Make: Cat No. ALD-WHM-573 of Jaguar or equivalent as per approved makes.
Supply and fix in brass chromium plated shower rose 125mm with or with swivel joints any size including fixing to steel pipe or union complete all as specified and directed. Make: CERA Cat No.F7020101 or equivalent as listed in approved makes
Supply and fix shower arm 15 mm size, 195mm long with bend of 45degree with flange of PTMT any colour.(Minimum weight 40gms) complete all as specified and directed.n complete all as specified and directed. Make: CERA Cat No. F7040102 or equivalent as listed in approved makes
EXTERNAL WATER SUPPLY:
Material & Labour for construction of brick masonry valve chamber of internal dimensions 600 x 600 x 750 mm, bottom floor of the pit shall be constructed in PCC (1:3:6) 15 cm thick with 20 mm stone aggregate, inner and exposed surfaces and bottom floor of the pit should be plastered in CM (1:4) 15 mm thick. The top cover of the pit shall be made out of MS sheet min 3 mm thick with angle iron frame made out of MS angle 40 mm x 40 mm x 6 mm with 02 nos steel hinges and locking arrangements duly painted with two coats of synthetic enamel paint over one coat of red oxide primer all as specified and as directed.
Cutting existing 80mm bore CPVC pipe for addition/ alterations and inserting tee of size 80X80X50mm including fittings, excavation and earth work, lead joints complete all as specified and as directed.
EXTERNAL ELECTRICFICATION AND STANDBY DG SUPPLY:
Supply and laying UG cable XLPE insulated, screened, PVC bedded, galvanised steel wire/strip armoured electric power cables, heavy duty LT 1100 Volt grade, with aluminium conductor of size 150 Sqmm 3.5 core including cable glands, aluminium lugs, nuts, bolts, washers etc and connections laid in trenches/ fixing on wall/ poles/ passing through pipes complete all as specified and as directed. NOTE: Excavation and earth work shall be measured and paid separately
All as per item No. 82 here in before, but for 3.5 core 70 Sqmm
All as per item No. 82 here in before, but for 3.5 core 35 Sqmm
All as per item No. 82 here in before, but for 4 core 25 Sqmm
All as per item No. 82 here in before, but for 4 core 16 Sqmm
All as per item No. 82 here in before, but for 2 core 6 Sqmm
Supply, fabricate, erection, connecting, testing and commisioning LT panel board outdoor type, weather and vermin proof made out of MS sheet of 3 mm thick as per IS 8623 with front and rear opening and locking arrangement and inner compartment made from CRCA sheet 1.6mm thick for switch gear, epoxy powder coated having colour seimens grey 1000A capacity aluminum bus bar for 3 phase and 1 No. 600A bus bar for neutral, mounted on epoxy insulator including necessary copper control wiring, heat shrinkable , RYB coloured sleeves over bus bar for identification, earth sheilds, circular holes at bottom /top to receive incoming and outgoing cable, cable lugs, cable gland of sizes as required , fixed on base frame of MSC 75mm grouted on PCC 1:3:6 type C1 foundation upto 45cm above ground level suitable for the following control/fitments sensible for 3 phase 50Hz, 415V system complete with and include following accessories suitable for incoming/outgoing arrangements:
(a) MCCB 250 Amp 4 pole (microprocessor based release) - 01 No (incoming) (b) Aluminium bus bar 400 Amp TPN - 01 set (c) Multi function digital meter (VAF & PF) - 01 No (d) Indicating lamp - 01 No (Set of three) (e) CT of suitable ratio - Set of 03 Nos (f) MCCB160 Amp 35 KA 4 pole - 02 Nos outgoing, ( DG 82.5 KVA & spare) (g) MCCB 100 Amp 35 KA 4 pole - 01 No outgoing, (DG 55 KVA),
Supply, fabricate, erection, connecting, testing and commisioning LT panel board outdoor type, weather and vermin proof made out of MS sheet of 3 mm thick as per IS 8623 with front and rear opening and locking arrangement and inner compartment made from CRCA sheet 1.6mm thick for switch gear, epoxy powder coated having colour seimens grey 1000A capacity aluminum bus bar for 3 phase and 1 No. 600A bus bar for neutral, mounted on epoxy insulator including necessary copper control wiring, heat shrinkable , RYB coloured sleeves over bus bar for identification, earth sheilds, circular holes at bottom /top to receive incoming and outgoing cable, cable lugs, cable gland of sizes as required , fixed on base frame of MSC 75mm grouted on PCC 1:3:6 type C1 foundation upto 45cm above ground level suitable for the following control/fitments sensible for 3 phase 50Hz, 415V system complete with and include following accessories suitable for incoming/outgoing arrangements:
(a) MCCB 160 Amp 35 KA 4 pole - 01 No ( Incomer) (b) MCCB 63 Amp 25 KA 4 pole - 1 Nos ( outgoing, bldg G'floor) (c) MCCB 40 Amp 25 KA 4 pole - 3 No (outgoing, VTPN DB1st floor, 2nd floor + 3rd floor) (d) MCCB 100 Amp 25 KA 4 pole - 1 No (outgoing, VTPN DB for Package type A/C) (e) MCB SPN 20 Amp - 2 No (1No Aviation Light + 01 No Perimeter light) (f) Aluminium bus bar 300 Amp TPN - 01 set (g) Multi function digital meter (VAF & PF) - 01 No (h) Indicating lamp - 01 No (Set of three) (j) CT suitable ratio - 01No (set of 3)
Supply, fabricate, erection, connecting, testing and commisioning LT panel board indoor type, weather and vermin proof made out of MS sheet of 2 mm thick as per IS 8623 with front and rear opening and locking arrangement and inner compartment made from CRCA sheet 1.6mm thick for switch gear, epoxy powder coated having colour seimens grey 1000A capacity aluminum bus bar for 3 phase and 1 No. 600A bus bar for neutral, mounted on epoxy insulator including necessary copper control wiring, heat shrinkable , RYB coloured sleeves over bus bar for identification, earth sheilds, circular holes at bottom /top to receive incoming and outgoing cable, cable lugs, cable gland of sizes as required , floor mounted fixed on base frame of MSC 75mm grouted on PCC 1:3:6 type C1 foundation upto 150mm above ground level suitable for the following control/fitments sensible for 3 phase 50Hz, 415V system complete with and include following accessories suitable for incoming/outgoing arrangements:
(a) Aluminium bus bar 400 Amp TPN - 01 set (b) Indicating lamp - 01 No (Set of three) (c) CT of suitable ratio - Set of 03 Nos (d) MCCB 250 Amp 4 pole (microprocessor based release) - 02 Nos (incomer - 01, outgoing to proposed panel - 01) (e) MCCB 63 Amp 4 pole (microprocessor based release) - 01 Nos (outgoing to existing bldg panel - 01)
Supply and fix LED street light fitting 60 W, 230 V AC out door type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed.
Supply and erect steel tubular swaged poles 410 SP-31, 9 meter long, conforming to IS 2713-1980 and MS tubing as per IS-1161, brought in two pieces welded at site complete with cast iron base plate, final taper plug, bolts, nuts and screws including two coats of aluminium paint over a coat of primer complete all as specified and as directed. Note: Earthwork shall be measured and paid seperately
Supply and fixing KD thermo plastic junction boxes IP 55 with metric knockouts for cable entry and four terminals suitables for LT cable upto the size of 2 core 10 sqmm and the size of the box is 200mm x 160mm x 98mm including MCB DP 10 Amps - 01 No & MCB SP 6.0 Amps - 01 No complete all as specified and as directed.
Riddled soil as earth cushioning to UG cable by using IS sieve to separate the composite particle/roots etc. and filling/spread in trenches as cushioning and punned to required thickness to form a solid bed complete all as specified and as directed. Note:1. Punned thickness only will be measured and paid . 2. Excavated approved soil shall be riddled by using sieve to separate composite particles etc as per IS.
Design, Supply, installation, testing and commissioning of wire mesh cable tray with cover all as per drg & details attached suitable for appx height 45 RM in vertical position on wall, made of stainless steel 316L- low carbon content (suitable for high temp & high corrosion applications) grade, specific fire resistance with complete accessories like coupler, standard supports, base frame and fixing arrangement suitable to hold designd load, clips, bolts, nuts, washers and Earth continuety conductor etc complies to Class 9D IEC 61537(10-2006). Cable tray shall be manufactured with a longitudinal 'T' weldes safety edge. Mounting accessories mechanically tested & supplied by cable tray manufacturer must be used with same finish as that of tray. Tray should comply satandard EN 10088-2-AISI 304L-X2CrNi 18.09 degreased, pickled & passivated at least 1000hrs of Salt Spray Test (SST) in accordance with the standard EN 9227/ ISO 9227. In addition stainless steel must be able to withstand at least 10 cycles of Kesternich SO2 test in accordance with DIN 50018. Assemblies with specific fire resistant properties must have an E30-E90 certificate. The cable tray system shall consist following sizes complete all as specified and as directed.
(a) Size- 600mm Width X105mm Depth (b) Size of member - As per drg attached (3.9 mm to 5.5 mm) (c) Length of each cable tray frame - 3000 mm (minimum) (d) Mesh cofiguration - 50mmx 100mm mesh (e) Maximum deflection on working loads = Span (L)/ 200, splicing at one fifth of the span (f) Resistance class against corrosion - Class 9D- IEC 61537 (g) MOC for tray cover - SS 316 l grade with minimum thickness 0.75 mm (h) Length of tray cover - 2000 mm/each (minimum) (j) Wiremesh jointing mechanism - Click fix type
Note:- Rate quoted shall deemed to be included for the following: (i) Cable tray shall manufacture with longitudinal 'T' weldedsafty edges. (ii) The deflection of cable tray must be not more than 1/200th of distance between two supports and tested accordance with the standered IEC 61537. (iii) All accessories including couplers, mounting accessories must be supplied by cable tray manufacturer and shall be same to same finish as tray. (iv) Wire tray must be designed with an optimum span of 1.5m taking in to account the maximum carring capacity authourised by manufacture. (v) All fixing arrangement, scafolding, safety measures, suitable clamps for holding cable up to 16 mm to 100 mm dia, base frame etc and other items which are not included in specification above but required to install the cable tray at position. (vi) Necessary certificate for strength and grade of steel issued by recogonised lab shall be submitted by the contractor. (vii) Rate also inclusive all fixing arrangement on wall and other fittings which are not mentioned in specification but required technically for proper fixing of cable tray at site all as per manufacturer recommendation.
(viii) Load testing as per manufacturer recommendation and shall be carried out in presence of user upto satisfaction of GE. (ix) Contractor shall submit copy of OEM test results duly signed by user and GE. (x) All joints and accessories shall be as per recommendation of OEM only (xi) Fixing arrangement of cable , wave guards shall be provide by the OEM as per site requirements.
All as per item No. 95 here in before, but for size 400mm width x 105mm depth without cover.
Supply, installation, testing & commissioning silent type diesel engine driven generating set comprising of capacity 82.5 KVA/ 66KW, 415 volts, 3 phase 4 wire, 1500 RPM 0.8 Power factor, 50 Hz directly coupled with diesel engine capable of taking 10% overload for one hour for every 12 hours (as per BS-5514) coupled directly to alaternator mounted on a rigid bed plate with suitable aqoustic enclosure and complete with standard control panel, battery, battery lead and fuel tank of suitable capacity with flexible coupling mounted on common base plate on vibration pads on foundation as recommended by manufacturer including AMF panel alongwith connected accessories with relay panel for automatic starting on main electric supply failure, control panel having meters, AVR control excitation. The DG set shall comprise of electric starter motor, turbo charger, water cooled and comprising all standard fittings/fixtures and all piping etc as below:-
ENGINE:- Diesel Engine direct injection, 4 stroke vertical in line cylinders, liquid cooled with specified shaft output after reduction of power for engine auxiliaries and when operating at a governed speed of 1500 RPM at NTP condition. The engine is suitable for continuous duty and conforms to IS 10000 (execpt for HA 694 and turbo chrged engines which confirm to BS 5514). The engine is complete with all standard accessories and fittings as detailed below. The emission from DG set shall not exceed the limits set by CPCB norms and the environment protection third amendment rules 2013, issued by Ministry of Environment and Forest GoI amended upto date.
1. Flywheel and flywheel housing. 2. 12 V DC electric start arrangement with maintenace free battery suitable capacity. 3. Exhaust Silencer 4. Fuel Filter (Pre and Micro) 5. Lube oil filter 6. Radiator (For liquied cooled DG set only) 7. Dry type Air Cleaner 8. Battery charging Alternator 9. Fuel hoses 10. Maintenance manual and spare parts catalogue. 11. Radiator fan (For liquid cooled DG set only) 12. Fuel injection pump with mechanical governor and fuel feed pump. 13. Engine safety protection for High Liquid / Cylinder Temperature and Low Lube Oil Pressure.
14. Closed Coupled Engine with inbuilt Anti Vibration Mounting Pads. 15. First Fill of Lube Oil. 16. First Fill of Coolant. 17. Genset Controller consists of Engine parameters like R.P.M, Liquid /Cylinder Temperature, Oil Pressure, Fuel level indication, Engine Hours run & Alternator parameters like Voltage, Frequency, Amps, KW, KVAR, PF etc. 18. Genset Controller also have protection for High Liquid Temperature, Low Lube Oil Pressure, Under speed & Over speed.
ALTERNATOR:- self - excited, self- regulated, screen protected, drip proof alternator with static excitation system, capable of developing rated output at 415V, 0.8 p.f, 50Hz when running at 1500 RPM at NTP conditons and conforms to the IS 4722 standards. ACOUSTIC ENCLOSURE:- Acoustic enclosure shall be powder coated and fabricated as per CPCB-II norms as per CPCB-II norms as amended upto date, sound level 75 dB (A) at 1 mtr from enclosure in free field conditions as per ISO 8528.The emission from DG set shall not exceed the limits set by CPCB norms and the environment protection third amendment rules 2013, issued by Ministry of Environment and Forest GoI amended upto date
CONTROL PANEL: Floor mounting fabricated sheet steel construction, suitable for single running manual operations and rated for system output. The panel should be made of 1.6 mm sheets and with one/two hinged front doors of 2mm sheet steel bolted back / sides, totally enclosed and vermin proof.
MATERIAL FOR AMF CONTROL PANEL: The micro processor based AMF panel shall be with AMF controller suitable to start the engine on main failure after 10-15 second time delay and to switch off engine only after 60-90 seconds after the main supply restored. The AMF controller shall have under/ over voltage, over load protection, coolant temp cut off, fuel control upto 10% tank capacity. The panel shall also have one change over switch and switch gears of suitable capacity to bypass main supply when the AMF control become defective. The panel should be made of 2 mm sheets and with hinged front doors.
Note : The following are included in the scope of work :- (a) The panel will be complete with internal wiring with suitable size of multi stranded copper cable. The suitable control of AMF panel with all meters, control wires. (b) Tools as supplied by the manufacturer (c) Fuel tank shall be provided inside canopy (d) Thermostat switch inside the acoustic enclosure shall be provided to shut off the DG set incase of temperature increases beyond its rated temperature inside the acoustic enclosure (e) There shall be proper air circulation and windows with glass in the acoustic enclosure suitably located to read the meters of various controls from outside (f) Necessary grouting including mild steel work and anti vibration pad shall be provided (g) Necessary foundation of installation and plinth protection of the DG set shall be provided as per manufactuers recommendation (h) Necessary 10% overload test shall be carried out in the presence of testing officer nominated by Accepting Officer.
AVIATION OBSTRUCTION LIGHT:
Supply and fix aviation obstruction light LED type medium indensity type 'C' luminious of 2000 Cadla Red obstruction light, Aluminium housing, covered by transparent glass/ polycarbonite input voltage 150-240 VAC range with mounting brackets, foundation complete at height appx 40m building complete all as specified and as directed.
Supply and lay UG cable XLPE insulated, screened, PVC bedded, galvanised steel wire/strip armoured electric power cables (heavy duty) LT 1100 Volt grade, with aluminium conductor of size 2.5 Sqmm 3 core in trenches/fixing on wall/poles/passing through pipes complete all as specified and as directed. NOTE: Excavation and earth work shall be measured and paid separately.
Supply and fixing MCB distribution board in sheet metal enclosure, powder coated, factory made IP 43 protection, IP 09 single door type SPN 2 way with 200 Amps without bus bar for use of MCB 5-32 Amps, SP fixed properly at directed place by using suitable required fixing arrangement all as specified and as directed.
Supply and fix MCB SP, 230 Volts, 5-32 Amps, 'C' series breaking capacity of 10KA complete all specified and as directed.
FIRE ALARM SYSTEM:
Supply, laying, testing and commissioning of flexible 2 core 1.5 Sqmm copper conductor, PVC insulated, cross laid up, overall Aluminum Mylar tape shielded along with ATC drain wire PVC outer sheated cable laid in existing complete all as specified and as directed .
Supply, installation, testing and commissioning of Fire Alarm Repeater/ Annunciator Panel shall display fire/ fault messages simultaneousely with FACP. It shall be capable of interfacing with the FACP on a single RS 485 Bus. The panel shall have a 2 x 40 charactet backlit alphanumeric LCD display, which shall display date, time & description of alarm/ trouble events that are displayed in the FACP with an inbuilt buzzer to indicate fault/ fire alarm. The repeater panel shall have the following LED's indications supply, fault, mute, silent disabled and fire. The panel shall be capable of operating on 24 V DC supply. The systems should have Modbus RTU/ASCII and Modbus TCP protocols.Users can easily intergate Modbus TCP and Modbus serial devices UL Listed and EN approved complete all as specified and as directed.
Supply, draw, connecting, testing and commissioning of 2 core 1.5 sqmm stranded copper conductor, PVC insulated PVC sheathed, aluminium myler tape shielded FRLS armoured cable fiited on surface/ in trenches etc for repeator panel complete all as specified and as directed. Note: Earth work shall be measured and paid seperately
Supply fire extinguisher dry chemical powder (ABC) type conf to IS: 15683, capacity 6.0 Kg complete all as specified and as directed.
Supply fire extinguisher CO2 type (light weight squeeze grip type) conf to IS: 15683, capacity 4.5 Kg complete all as specified and as directed.
Supply fire extinguisher Clean Agent type HFC 236, wall mounted conf to IS: 15683, capacity 4.0 Kg complete all as specified and as directed.
Supply fire extinguisher dry powder (ABC) type conf to IS: 15683, capacity 9.0 Kg complete all as specified and as directed.
Supply Mechanical Foam Extinguisher (stored pressure type) conf to IS: 15683, capacity 9.0 Ltr complete all as specified and as directed.
Supply fire buckets (Dry sand) conf to IS: 2546 complete all as specified and as directed.
AIR CONDITIONING:
Supply, install, testing and commissioning hi wall split Air conditioner units, indoor & outdoor unit invertor type complete with cordless remote control unit, refrigerant line & drain pipe of required length at site, fixing arrangement on wall as recommended by OEM and in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity 1.5 TR complete all as specified and as directed.
Supply, install, testing and commissioning hi wall split Air conditioner units, indoor & outdoor unit invertor type complete with cordless remote control unit, refrigerant line & drain pipe of required length at site, fixing arrangement on wall as recommended by OEM and in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity 2.0 TR complete all as specified and as directed.
Supply and fix voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variatiuon between 150 V to 290 V with output voltage stabilized at 230V with accuracy of +/- 2.5 % suitable for air conditioner 1.5 TR with minimum capacity 3 KVA complete all as specified and as directed.
Supply and fix voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variatiuon between 150 V to 285 V with output voltage stabilized at 230V with accuracy of +/- 2.5 % suitable for air conditioner 2.0 TR with minimum capacity 4 KVA complete all as specified and as directed.
Design, supply, install, testing and commissioning of air cooled, packaged ductable air conditioning system, complete with Machine (High side) floor mounted inverter type packaged AC units of sepecified capacities with scroll compressor, condensing unit with all standard fittings, safety devices, like HP/LP cutout, initial filling of refrigerent Gas, PVC drain piping with insulation, SA/ RA duct & grills as per design approved by GE, single phase preventor, overload relays, vibration isolation pads etc required for commissioning and smooth functioning of air-conditioning unit compressing the following:.
TECHNICAL SPECIFICATION: Minimum nominal cooling capacity :3 x 11 TR (Two working + 01 standby) Type: Floor mounted, Aircooled, package air conditioner Room Size: As per Drg (Ground Floor room Size 5700 x10200 mm) Design Temp: 20+/-2 degree centigrade. User Data sheet enclosed. Refrigerant: R410a Power supply: 415 volt, Three phase, 50 Hz (indoor) & 230 volt 01 phase for outdoor. Type of blower: Centrifugal forward curved, double Inlet, double width. Controller: Innovative Intelligent Inverter Controller Compressor: Hermetically sealed Inverter scroll Foundation: PCC 1:3:6 upto 60 cm above ground level
NOTE: Rate quoted rate shall deemed to be included for the following:- (i) Refrigerant piping (suction & discharge) hard drawn from hard copper tube of suitable sizes, with copper elbows, tees etc as required and recommended by OEM , Referigerent piping for ductable units. (ii) Ducting:- GI rectangular ducts, complete with all fittings such as tee, bends, special off shoots, inspection doors, tranformation pieces etc. as required as per IS 655 including suspension and supporting arregement for plenum, duct etc as required. (iii) Duct insulation & Lining:- Acoustic insulation of ducts should be 9 mm open cell Nitrile rubber. Thermal insulation of ducts should be 9 mm open cell Nitrile rubber-Canvas Connection.
(iv) Powder coating Aluminium grille for supply/ return air grille ( with coller damper for supply grills) (v) Fresh air duct with bird screen cowl heater banks etc. (vi) Electrical wiring from DB to indoor unit & outdoor units including control switches. (vii) Contractor shall submit GA drg, design details for refrigeration, duct, SA grills etc for approval.
WATER COOLER:
Supply, installation, commissioning water cooler with Stainless steel body, water purifier system single phase 230 volt, with RO + UV technology of capacity of appx flow rate 100 L/ hr with 3 Nos (normal, hot and cold water) outlet having minimum 15 Litre Normal & 15 Litre Cold water storage capacity complete all as specified and as directed.
Supply and fixing Voltage stabilizer for auto operation, single phase, naturally air cooled indoor type and designed working voltage range 150 to 280 V for capacity 2.0 KVA complete all as specified and as directed.
WIRE ROPE ELECTRIC HOIST:
Design, Supply, installation, testing and commissioning of wire rope electric hoist with electric trolly of capacity 1.0 Ton (minimum, complete with ISMB for Mono rail as per approved design & bldg plan, cable trailing system for trolley movement on monorail, wire rope for travelling, rope tightness, U clamps, Rope tightness, U clamps, MS brackets, wiring from isolator to hoist with 4 core copper cable, cable trolleys, clamp, brackets etc. all as per technical specification given below suitable to facilitate hoisting and lowering of heavy equipment/ Antenna drive motor and other items is to be provided on roof top complete al las specified and as directed.
NOTE: Unit rate quoted shall deemed to be included for the following: (i) Design, supply & installation of ISMB mono rail required size & length as shown in Drg. (ii) Contractor shall submit GA drg and technical specification and design detail for approval of GE. (iii) Arrangement for load testing by GE. (iv) Load testing shall be carried out in presence of user and upto the satisfaction of GE.
TECHNICAL SPECIFICATION: Type: Wire rope electric hoist with electric trolly. Capacity: 1 Ton (Minimum) Lift: 40 Mtr (appx) Lift speed: 5.0 - 6.0 mtr per minutes Travelling speed: 15.0 - 17.0 Mtr per minutes No of falls: Two Mono rail: ISMB with flange width 90 mm (Min) - 180 mm (Max), length as shown in bldg plan / Drg and approved by GE. Hook: High resistance hook with safety latch. Breake: Robust design & built hoist brake motor.
Safety: Geared rotary limit switch, Mechanical stoper, oveload slipping clutch. Motor (hoist & trolly): 2 Nos, 3 phase 415 volt, capacity As per manufacturer design. Operation: Pendent push button. Wire rope: As per IS standard and size not less than 8 mm dia. Electric Control panel : As per OEM recommendation
Supply and lay UG cable XLPE insulated, screened, PVC bedded, galvanised steel wire/strip armoured electric power cables(heavy duty) LT 1100 Volt grade, with aluminium conductor of size 6 Sqmm 4 core in trenches/fixing on wall/poles/passing through pipes complete all as specified and as directed. NOTE: Excavation and earth work shall be measured and paid separately.
Supply and fix perforated gavanised iron cable tray of size 300mm width 50mm depth made of 2mm thick GI sheet metal including all fixing arrangement on wall in vertical of height approximate 40m NOTE: Excavation and earth work shall be measured and paid separately.
SEWAGE DISPOSAL:
Soakage wells of size 1.8mx3.00m effective depth excavation in any type of soil and removal, foundation in PCC 1:3:6 walls of honey combed masonry with top ring of M25 concrete including interception chamber and screen chamber made of brick masonry in CM, RCC cover slab in M25/SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats all as specification and directed.
On site Hume pipe septic tank for 10 users capacity incl necessary earth work in soft/loose soil and removal designed to carry sewage and sullage water excavation in any type of soil, PCC 1:4:8 below foundation vent shaft connection etc complete all as shown in drg and as directed by Engr-in-Charge.
VIJAY CONSTRUCTIONS
FUTURE ONE FACILITY MANAGEMENT
SHAIJAL T M
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .