| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.8 LAccepted-AOC | L1 | Accepted-AOC Being Lowest L1 | |
| 2 | L2₹8.3 L+₹45,223.84 (5.78%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹8.4 L+₹53,384.90 (6.82%)Rejected-AOC | L3 | Rejected-AOC L3 |
Tender Value
Refer Docs
EMD Value
₹15,600
Closing Date
1 Feb 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer (I) (P) Fy Avadi Chennai 600054
Garrison Engineer (I) (P) Fy Avadi Chennai 600054
PROVISION OF MINOR WORK AND SANCTIONED WORK AT OFT TRICHY UNDER GE I P FY AVADI
2021_MES_411286_1
8588/E8
Open Tender
Civil Works
Item Rate
90 days
Garrison Engineer (I) (P) Fy Avadi Chennai
As per Tender Documents
7 documents required · 7 mandatory
₹500
Yes
Garrison Engineer (I) (P) Fy Avadi
₹15,600
Yes
11 Feb 2021
11 Jan 2021
6 Feb 2021
11 Jan 2021
1 Feb 2021
20 Jan 2021
12 Jan 2021 - 19 Jan 2021
60 days
Amount
Surface excavation n. exc. (not exceeding) 30 cm deep and averaging 15 cm deep and getting out in hard / dense soil all as specified .
Excavation in trenches, n. exc. 1.5 m wide and n. exc. 1.5 m in depth; for foundation, etc. n exc 10 sq m on plan and n exc 1.5m in depth and getting out in soft/loose soil all as specified.
Excavating over areas, n. exc. 1.5m deep and getting out hard / dense soil complete all as specified and as directed.
All as per item No 3 above but exc 1.5m and n. exc. 3.0m deep and getting out hard/ dense soil complete all as specified and as directed.
All as per item No 3 above but depth exc 3.0 mtr and n. exc. 4.5 mtr and getting out hard / dense soil complete all as specified and as directed.
Boring holes any depth in any type of soil / soft disintegrated rock / hard rock for 150 mm dia pipe including inserting the pipe inside bore and disposal of soil to a distance of n exc 50 m as directed. Note: a) UPVC pipe wshall be measured & paid seperatly under Sl Item No. 18 as supply only. b) Performance of pipe shall be done for 1 Mtr lenght at 3 to 4 Mtr below GL in 150 mm dia UPVC Pipe.
M & L for loose filling with broken stone or boulders aggregates of guage 80 mm to 150 mm in well and bore holes etc complete all as specified & as directed.
M & L for loose filling with broken stone or boulders aggregates of guage 40 mm to 80 mm in well and bore holes etc complete all as specified & as directed.
M & L for sand filling for rain water harvesting under floors, in foundations etc including watering and consolidation complete all as specified & as directed.
M&L for plain cement concrete Type C-2, 1:3:6 (using 40 mm graded aggregate) in foundation filling and mass concrete complete all as specified and directed
M&L for PCC block masonry , type C-1, mix 1:3:6 (using 20mm graded stone aggregate) with solid blocks, exc 10cm in width and setting in CM 1:6, complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed
Removing excavated surplus material (soil) not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed.
M&L for Plain cement concrete 1:2:4, type B1 (using 20 mm graded stone aggregate) as in haunching / channel inside manholes, Coping etc surfaces finished even and smooth using extra cement, including necessary formwork, all as specified and as directed.
M&L for rendering 15 mm th in CM 1:6 on fair faces of brickwork or concrete surfaces finished even & smooth without using extra cement all as specified and directed.
M&L for Precast reinforced cement concrete 1:2:4 type B1 using 20mm graded stone aggregate as in coping slab,cover slab etc including necessary form work etc., complete all as specified and as directed by Engineer in Charge. Note : Reinforcement shall be measured and paid separately.
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required including cranking hooking ends and binding with and including MS wire (annealed) not less than 0.9 mm dia complete all as specified and as directed.
Supply only 150mm bore UPVC Pipes (SCH-80) all as specified and as directed.
M&L Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walkways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 all as specified and as directed by Engineer in Charge.
M&L for Welded steel wire fabric supplied and fixed complete to wood or steel members n.exc 4Kg per Sqm all as specified and as directed.
M&L for PVC (SWR) vent cowl of 150mm dia all as specified and as directed.
M&L for Walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar 1:4 complete all as specified and as directed by Engineer in Charge.
M&L for Keyed pointing to random rubble masonry, uncoursed or brought upto courses in CM 1:3 all as specified and as directed by Engineer in Charge.
Forming embankments including raising (or lowering) earth, spreading in layers n.exc 30cm thk, watering/ rolling and finishing to required size, shape etc n.exc 1.5m high from base of soil complete all as specified and as directed by Engineer in Charge. ( Earth obtained from Excavation)
M&L for Hard core of gauge not exceeding 63 mm using broken stone/boulder, deposited, spread and levelled in layers n.exc 150 mm thick watered and rammed to a true surface complete all as specified and directed
M&L for 100 mm thick plain cement concrete Type D-2, mix 1:4:8 (using 40 mm graded stone aggregate) in sub base complete all as specified and directed
M&L 75 mm thick plain cement concrete (1:2:4) type B1 using 20 mm graded crushed stone aggregate as in floor complete finished even & fair without using extra cement all as specified and directed.
Forming 12 mm thick Expansion joints in 100 mm thick concrete slab filled with pre-formed bituminiuos filler and top 30 mm primed and sealed with sealing compound Grade 'B' all as specified & as directed.
M & L for finishing concrete surfaces roads, pavement, path etc by brooming
S&F anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified & as directed.
S&F anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips,rubber packing, anodised aluminium snap beading, screws,anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1no.) complete all as specified & as directed.
S&F 3mm thick plain ordinary glass fixed in squares exc 0.5 Sqm in each panes with wooden beading or glazing putty
S&F aluminium anodised grills (pattern DG-102) weight of 2.00 to 3.20 Kg/Sqm for windows, ventilators, etc including jointing, cleats etc and fixed with medium screws into walls / frame work etc complete all as specified and as directed.
S & F 12 mm thick Ceiling board fibre insulation with fire retardant type coating treatment on only one side for insulation and acoustic of size 600 x 600 mm with aluminium, anodised frame work of grid 600 x 600 mm of fixed with screws 6 mm dia GI wire hanged from roof truss/ roof slabs by means of ceiling cleats made out of GI flat 40x3 mm size minimum 60 mm long and expansion hold fasteners 12.5mm dia 40 mm long or as per site requirement fixed in flat or sloping roof complete all as specified and as directed
Supply and install hi wall split type airconditioner unit indoor and outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2 of capacity 2 TR complete all as specified and directed. Make LG 2 ton 3 star LS-Q24HNXA1 inverterr split AC or equivalent make in VOLTAS / BLUESTAR / CARRIER / SAMSUNG / PANASONIC
S & F Industrial type plug socket and plug top complete with SP MCB 20 Amps all as specified and directed.
Taking down Ceiling fan, and disconecting from ceiling and refixing the same as its own position including provision of extension rod up to 3ft of the fan connection from ceiling rose to fan complete all as directed by Engr-in-charge.
M&L for Point wiring complete with FRLSH PVC insulated unsheathed , 1100 V grade conforming to IS 694 , 1.5 Sq mm for power point (Norminal area) multistranded ,copper conductor cable drawn through in non metallic rigid PVC conduit medium grade ,minimum 20 mm dia, ISI Marked, and connected accessories, mounting on surface of walls / ceilings /roofs etc or concealed in wall all as per site requirement with shunken box pressed type mild steel made out by 16 gauge mild steel sheet with hold fasts and concealed in suface of wall/ ceiling / roof etc, 3 mm thick laminated sheet cover for mounting of switches, sockets outlets, regulators etc, fixed by suitable size of 04 Nos cadmium screws including provision of FRLSH PVC insulated unsheathed 1.5 Sqmm muiltistranded copper conductor cable as earth connectivity and connecting to common earth dolly complete all as specified and directed for One light point controlled by one, one way switch SP 5 Amps 240 Volts including taking down old existing point wiring with all fittings etc
All as per item No. 38 here-in-before but with One ceiling fan point controlled by one, one way switch SP 5 Amps 240 volts
M&L for ceiling rose surface type polycarbonate / bakelite 65x20 mm size three terminal complete all as specified and directed
S&F for Switch piano flush type 5 Amps SP one way 240 volts
S&F LED light fitting 1 x 22 W (4 feet),240volts,50 Hz with indoor decorative PVC extruded batten integrated LED driver complete with all accesories internally pre-wired and including LED tube rod and connecting up with twin core twisted flexible copper conductor cable of suitable size, PVC Square/round box (2 Nos) complete all as specified and directed. Make:Havells Cat No. ENDURALINEARNEOBS22WLED 865SPCWH or its eqlt in Wipro/Philips/GE lighting / CG/ Bajaj
S&F stepped type electronic fan regulator, 240Volts, 50Hz ,minimum 100 watt flush type complete all as specified and as directed.
M&L for Sub main wiring complete with two runs of 4.0 Sqmm for phase and neutral 1100 volts grade single core FRLSH insulated unsheathed multistranded copper conductor, drawn through and including metalic steel conduit of minimum 20mm nominal dia, ISI marked with all conduit accessories mounting on surface of walls / roofs / floors etc. with one run of 4 Sqmm single core FRLSH insulated unsheathed with one copper conductor as earth wire complete all as specified and as directed. Note: (1) Two runs of 4 Sqmm cable, one run of 4 Sqmm earth conductor and one run of conduit will be measured as one unit lenght. (2) Quoted rate deemed to include for making good the disturbed surface to match with the existing adjoining undisturbed surface / finishes complete all as specified and as directed by Engineer-in-Charge.
Green Ray Technologies
SINI PROMPT
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .