Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹40.5 LAccepted-AOC DOOR NO 38 I H COLONY MALKAPURAM POST VISAKHAPATNAM 530 011 | VISAKHAPATANAM | ANDHRA PRADESH | 530011 | 1 | Accepted-AOC AWARDED BEING THE LOWEST TENDERER | |
| 2 | 2₹46.9 L+₹6.3 L (15.5%)Rejected-Finance ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | 2 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER | |
| 3 | 3₹49.4 L+₹8.8 L (21.6%)Rejected-Finance | 3 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER | |
| 4 | 4₹49.6 L+₹9.0 L (22.3%)Rejected-Finance | 4 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER | |
| 5 | 5₹50.3 L+₹9.7 L (23.9%)Rejected-Finance | 5 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER |
Tender Value
₹49.5 L
EMD Value
₹99,000
Closing Date
20 Feb 2024, 6:00 pmClosed
GARRISON ENGINEER NAVAL BASE VISAKHAPATNAM
GARRISON ENGINEER NAVAL BASE GANDHIGRAM POST VISAKHAPATNAM 530005
PROVISION OF INTERLOCKING TILES IN FRONT TO BUILDING NO P-150 (FAMILY WELFARE CENTRE) FOR CAR/SCOOTER PARKING AT NAUSENA BAUGH , AS AND AS TO RUSSIAN LANGUAGE TRAINING LABS WITH PROVISION OF AIR CONDITIONS (ACS) STABILISER, ELECTRIC CABLING AND
2024_MES_639795_1
C/8286/23-24/E8 / Token 109 of 2023-24
Open Tender
Civil Works
Item Rate
180 days
VISAKHAPATNAM
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GARRISON ENGINEER NAVAL BASE
₹99,000
Yes
27 Mar 2024
30 Jan 2024
27 Feb 2024
30 Jan 2024
20 Feb 2024
13 Feb 2024
Amount
Surface excavation n. exc 30 cm deep and averaging 21 cm deep and getting out in hard/dense soil complete all as specified and directed.
Rolling and consolidating formation surfaces in cutting with power roller exc 8 tonne and nexe 12 tonne complete all as specified and directed.
M & L for hardcore of gauge n.exc 63 mm of broken stone or boulders, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
Removing excavated material exc. 1.00 Km but nexc 1.5 Km and outside MOD land depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed.
M & L for 75 mm thick, plain cement concrete 1:4:8, type D-2 (using 40mm graded stone aggregate) as in sub base complete all as specified and directed.
M & L for Sand filling under floors or in foundations including spreading, levelling, watering and consolidation complete all as specified and directed.
M & L for Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment complete all as specified and directed.
M & L for plain cement concrete (1:2:4), type B1 (using 20mm graded stone aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including necessary formwork complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and disposal of debris and rubbish to outside MD land complete all as specified and directed.
M & L for 25 mm thick, plain cement concrete 1:2:4, type B-0 (using 12.5 mm graded stone aggregate) as in sub-base of flooring, etc and finished the surface even and rough complete all as specified and directed.
M & L for non-skid, ceramic, coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.11 sqm but n.exc 0.18 sqm, in floors etc, including 15 mm thick screed bed in cement mortor 1:6 and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed.
M & L for glazed, coloured, ceramic, tiles of size 450mm x 350mm x 6 to 7 mm thick, on vertical surfaces such as skirting, dados etc, including 10 mm thick bedding in cement mortor 1:4 and set & jointed in neat cement slurry & pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed.
M & L for non-skid, ceramic, coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.18 sqm but n.exc 0.38 sqm, in floors by providing 3 mm spacers and filling with epoxy grout of shade matching with tiles, including 15 mm thick screed bed in cement mortor 1:6 and set & jointed in neat cement slurry complete all as specified and directed.
All as per item no 13 here-in-before but on vertical surfaces such as skirting, dados etc, including 10 mm thick bedding in cement mortor 1:4 and set & jointed in neat cement slurry & pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed.
Material and labour for preparation of old decorated surface of wall by complete removal of existing treatment, washing, rubbing, stopping etc and applying two coats of oil bound washable distemper over a coat of alkali resistant primer including applying one or more coat of wall care putty to a smooth surface including making good any undulations on the surfaces complete all as specified and as directed. Note :- Painting work shall be carried out acoording to Smart Painting procedure mentioned in PS
Material and labour for preparation of old decorated surface of ceiling by complete removal of existing treatment, washing, rubbing, stopping etc and applying two coats of oil bound washable distemper over a coat of alkali resistant primer complete all as specified and as directed. Note :- Painting work shall be carried out acoording to Smart Painting procedure mentioned in PS
Material and labour for preparation of new platered surface of wall and applying two coats of weather proof exterior acrylic emulsion paint having dart pick up resistant,silicon enhanced and PU enhanced property including all necessary scaffolding,complete all as specified and directed. Note :- Painting work shall be carried out acoording to Smart Painting procedure mentioned in PS
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and directed.
S & F 8 mm thick, heat absobing glass, glazing with oil putty including solar control film 25 micron reflective type sticker fixed on glass panes in square exceeding 0.5 Sqm in each pane complete all as specified and as directed.
S & F Aluminium (Die cast) body door Closer hydraulically regulated, designation No 3, universal type, suitable for door shutter of 851 to 1000 mm in width and of weight between 61 to 80 Kg complete all as specified and directed.
S & F Floor door stopper, 150 mm overall length of cover plate, brass body and tongue with hard drawn steel spring, fixed in floor complete all as specified and directed.
Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water and removing rubbish to outside MD land complete all as specified and directed
M & L for rendering 15 mm thick in two coats (10mm+5mm each) on fair faces of brick work or concrete surfaces in cement mortar 1:4, mixed with integral water proofing compound with weight of cement in top layer as per manufacturer's instructions and finished the surface even and fair without using extra cement complete all as specified and directed. (Note : WPC shall be measured and paid separately against respective item).
Supply only integral water proofing compound (ISI marked) complete all as specified and directed.
M & L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished the surfaces even and fair without using extra cement complete all as specified and directed.
M & L for rendering 5 mm thick in cement mortor 1:3 on concrete surfaces as in ceilings and finishing surfaces even and fair without using extra cement complete all as specified and directed.
Material and labour for preparing newly plastered surfaces of internal walls, etc and applying two coats of oil emulsion distemper over a coat of alkali resistant primer complete all as specified and as directed. Note :- Painting work shall be carried out acoording to Smart Painting procedure mentioned in PS
Material and labour for preparing newly plastered surfaces of ceiling, etc and applying two coats of oil emulsion distemper over a coat of alkali resistant primer complete all as specified and as directed. Note :- Painting work shall be carried out acoording to Smart Painting procedure mentioned in PS
Demolition of un-reinforced cement concrete in ground floors and pavings n.exc 15cm thickness, (Below or above Ground level) and disposal of debris and rubbish to a distance upto outside MD land complete all as directed by the Engr-in-Charge
M & L for Sub main wiring with 4 runs of Single core 10 sqmm PVC insulated, unseathed, multi stranded FRLSH (ISI marked) copper cable drawn through and including surface PVC conduit of suitable size with all conduit accesories and fittings along with 1 run of single core 10 sqmm PVC insulated ,unseathed multi stranded FRLSH (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- Four runs of 10.00 sqmm and one runs of10.00 sqmm cable as earth wire and one run of conduit shall be measured as one length)
M & L for Sub main wiring with 4 runs of Single core 6.00 sqmm PVC insulated, unseathed, multi stranded FRLSH (ISI marked) copper cable drawn through and including surface PVC conduit of suitable size with all conduit accesories and fittings along with 1 run of single core 6.00 sqmm PVC insulated ,unseathed multi stranded FRLSH (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- Four runs of 6.00 sqmm and one runs of 6.00 sqmm cable as earth wire and one run of conduit shall be measured as one length)
M & L for Sub main wiring with 2 runs of Single core 4.00 sqmm PVC insulated, unseathed, multi stranded FRLSH (ISI marked) copper cable drawn through and including surface PVC conduit of suitable size with all conduit accesories and fittings along with 1 run of single core 4.00 sqmm PVC insulated ,unseathed multi stranded FRLSH (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- Two runs of 4.00 sqmm and one runs of 4.00 sqmm cable as earth wire and one run of conduit shall be measured as one length)
Supply and fixing MCB TPN DB ,Double door, made up with sheet metal, phosphorised, power coated, neutral link, earth bar and din rail, 6 way TPN with 200 Amps rated busbar, 240 volts complete all as specified and directed.
Supply and installation of Tower AC indoor and outdoor unit, 4.00 TR capacity , BEE 5 star rated ,three phase, 415 volt,50 Hz, 100% copper, High energy efficient invertor Compressor ,inbuilt air ioniser and plama filter with cordless remote control complete all as specified and directed. Make: Bluestar,Carrier,Voltas,LG, Daikin ,Hitachi
S&F MCB TP 50-63 Amps, 415 Volts, 10KA, C curve complete all as specified and as directed
S&F MCB TPN 50-63 Amps, 415 Volts, 10KA, C curve complete all as specified and as directed
Supply and fixing copper pipe line heavy duty 3/8" dia with flair nuts and insulation as sunction/ discharge pipe of split AC/Tower AC complete all as specified and directed.
All as per item no 37 but 5/8" dia copper pipe complete all as specified and directed.
All as per item no 37 but 1/4" dia copper pipe complete all as specified and directed.
All as per item no 36 but 1/2" dia copper pipe complete all as specified and directed.
S&F 25mm outer dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings fixed on wall for air condition water discharge pipe and connecting into rain water discharge pipe complete all as specified and directed
S & F UPVC cable trunking casing and capping of size 100x100 mm including cover, bends, elbow, coupler, tees, internal and external bends, arranging existing cables/copper refrigerator pipe etc and making good the disturbed surfaces to match with existing surfaces complete all as specified and directed.
S & F Vertical DB double door for provision for four pole MCCB upto 160A incommer 4 way12 outgoing with IP 43 protection complete all as specified and as directed. (Make : Legrand cat part No. 5077 58 or equivelant of make as per List of manufacturer's)
S & F MCCB 415 Volt, 25 KA, 4 Pole, 160 Amps Capacity complete all as specified and as directed. (Make: Legrand Cat Part No. 4200 57 or equivelant of make as per List of Manufacturer's)
S & F Distribution Board, SPN, 12 way, 415V, Double door with IP 43 protection complete all as specified and as diretced complete all as specified and directed. (Make : Legrand Cat Part No. 5076 02 or equivelant of make mention in PS)
S & F Distribution Board, TPN, 4 way, 415V, Double door with IP 43 protection complete all as specified and as diretced complete all as specified and directed. (Make : Legrand Cat Part No. 5076 70 or equivelant of make mention in PS)
S&F MCB SPN 40 Amps, 415 Volts, 10KA, C curve complete all as specified and as directed
S&F MCB SP 32 Amps, 415 Volts, 10KA, C curve complete all as specified and as directed
S&F MCB TP 63 Amps, 415 Volts, 10KA, C curve complete all as specified and as directed
S&F Socket Residual Current Device (SRCD) With Steel Enclosure two pin and earth plug including 20 Amps MCB SP complete all as specified and as directed (Make : Havells Cat Part No. DHDDCDP025202003 or equivelant model of make mention in PS)
S & F MS stand for mounting outdoor unit of Tower Ac of capacity 4.00 Ton complete all as specified and as directed.
S & F sheetmetal TPN MCB encloser with and including one TPN MCB of capacity 32 Amps 415 Volt complete all as specified and as directed. Make : (a) Encloser : Legrand Cat Part No.5077 92 or equivelant of make mention in PS (b) MCB :- Legrand Cat Part No. 4086 79 or equivelant of make mention in PS
S & F MS stand for mounting outdoor unit of Split Ac of capacity 1.5 Ton complete all as specified and as directed.
Supply, installation and testing inverter split AC units indoor/outdoor complete with cordless remote control with inbuilt air ioniser and plasma filter for better indoor air quality, minimum 5 star rating,copper condenser,copper cooling coil and EER 3.2 of capacity 1.5 TR including 2.5 sqmm 4 core flex copper cable connection from indoor to outdoor unit as per site requirement including making holes of required dia on walls and necessary masonry work for making good distrubuted surface and match with the existing colour complete all as specified. Note :- Copper pipe , insulation and connecting cable, angle iron bracket will be neasured and paid separately under respective item MAKE:- Daikin Model No. FTKM50UV16U/V / Hitachi Model No. RSRG518FFEO KIYORA5200 / O- General Model No. ASGG18CETAB”
S & F voltage stabilizer of capacity 4 KVA, single phase, input working voltage 170-270 Volts, metal body with time delay system, wall mountable, built in thermal overload protection, low & high voltage cut-off protection, micro controller based design complete all as specified and directed. Make: V-Gaurd model no VG-400 or equivalent model of make mentioned in PS
Supply and laying XLPE insulated PVC sheathed, armoured, aluminium conductor cable 1100 Volt grade 70 Sqmm 3.5 core in duct / floor / wall with provision of saddle lugs, clamps,joints etc including connection complete all as specified and directed by Engineer-in-Charge.
SRI LAKSHMI ENGINEERING ENTERPRISES
M/S S K ENGINEERS
SRI DHANESWARI ENGINEERING WORKS
BHARATHI ENTERPRISES
SRI VIJAYA LAKSHMI ENTERPRISES
SSV CONSTRUCTIONS
RAVITEJA ENGINEERING WORKS
BHAVANA ENTERPRISES
ALLURI CONSTRUCTIONS
Bidder Name
ALLURI CONSTRUCTIONS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .