Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹29.4 LAccepted-AOC | 1 | Accepted-AOC L1 | |
| 2 | 2₹33.9 L+₹4.2 L (14.2%)Rejected-Finance 201 BARI CO OPERATIVE COLONY SECTOR 12 TENTULYA BOKARO JHARKHAND 827012 | BOKARO | JHARKHAND | 827012 | 2 | Rejected-Finance L2 | |
| 3 | 3₹34.6 L+₹4.9 L (16.3%)Rejected-Finance 10B DR LAHIT BANERJEE SARANI GROUND FLOOR KOLKATA 700 073 | KOLKATA | KOLKATA | WEST BENGAL | 700073 | 3 | Rejected-Finance L3 | |
| 4 | Rejected-Technical 86 TOLLYGUNGE CIRCULAR ROAD KOLKATA WEST BENGAL 700053 | KOLKATA | KOLKATA | WEST BENGAL | 700053 | - | Rejected-Technical Techno-Commercially Disqualified. |
Tender Value
₹36.3 L
EMD Value
₹72,700
Closing Date
5 Nov 2021, 6:00 pmClosed
THE GM(STPS)
ADMIN BUILDING, STPS,THE WBPDCL.
02(Two) year Rate Contract for maintenance of Air Conditioning machines at both STPS Plant and Township under the maintenance scope of OPH (EM) Dept. STPS.
2021_WBPDC_345740_1
WBPDCL/STPS/NIT/E2549/21-22
Open Tender
MISC ELECTRICAL WORKS
Item Rate
730 days
ADMIN BUILDING, STPS, THE WBPDCL.
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹72,700
Yes
ADMIN BUILDING, STPS,THE WBPDCL.
26 May 2022
28 Sept 2021
9 Nov 2021
28 Sept 2021
5 Nov 2021
7 Oct 2021
5 Oct 2021
Amount
Immediate attending of the trouble of 1 TR / 1.5 TR / 2 TR / 3 TR capacity Window / Split / Floor A.C. Machine, Refrigerator during day or night per machine, at STPS plant or township.
Shifting of the A.C. m/c from OPH (EM) working bay to the A.C. working area and then Installation of the Window type AC Machine of capacity 1 TR / 1.5 TR / 2 TR with wooden frame & required materials at different locations of Plant & Township.
Shifting of the A.C. m/c from OPH (EM) working bay to the A.C. working area and then Installation of the Split type AC Machine of capacity 1 TR / 1.5 TR / 2 TR /3 TR with wooden frame & required materials at different locations of Plant & Township.
Shifting of the A.C. m/c from OPH (EM) working bay to the A.C. working area and then Installation of the Floor type AC Machine of capacity 3.01 TR with required materials at different locations of Plant & Township.
Disconnection from its own base & then shifting to OPH (EM) working bay of Window type AC Machine of capacity 1 TR / 1.5TR / 2 TR from different locations of Plant & Township
Disconnection from its own base & then shifting to OPH (EM) working bay of Split type AC Machine 1 TR / 1.5 TR / 2 TR / 3 TR from different locations of Plant & Township.
Disconnection from its own base & then shifting to OPH (EM) working bay of Floor type AC Machine of capacity 3.01 TR from different locations of Plant & Township.
Disconnection and reinstallation of Window type AC Machine 1 TR / 1.5 TR / 2TR at different locations of Plant & Township.
Disconnection and reinstallation of Split type AC Machine 1 TR / 1.5 TR / 2TR / 3 TR at different locations of Plant & Township
Disconnection and reinstallation of Floor type AC Machine of capacity 2 TR at different locations of Plant & Township
Replacement of the Compressor of 1 TR capacity Window type AC m/c including supply of the compressor
Replacement of the Compressor of 1.5 TR capacity Window type AC m/c including supply of the compressor
Replacement of the Compressor of 2 TR capacity Window type AC m/c including supply of the compressor
Replacement of the Compressor of 1 TR capacity split type AC m/c including supply of the compressor
Replacement of the Compressor of 1.5 TR capacity split type AC m/c including supply of the compressor
Replacement of the Compressor of 2 TR capacity split type AC m/c including supply of the compressor
Replacement of the Compressor of 3 TR capacity split type AC m/c [voltage level: 415 volt] including supply of the compressor
Replacement of the Compressor of 3.01 TR capacity Floor type AC m/c including supply of the compressor
Replacement of the Compressor of 7.5 TR capacity Ductable type AC m/c including supply of the compressor
Repair of Control Card for Window type AC m/c of Capacity 1 TR / 1.5 TR / 2 TR
Repair of Control Card for Split type AC m/c of Capacity 1 TR / 1.5 TR / 2 TR
Repair of Control Card for Split type AC m/c of Capacity 3 TR [voltage:415V
Repair of Control Card for Floor type AC m/c of Capacity 3.01 TR
Repair of Control Card for Ductable type AC m/c of Capacity 7.5 TR
Replacement of Control Card including supply for 1 TR capacity Split/Window type AC m/c.
Replacement of Control Card including supply for 1.5 TR capacity Split/Window type AC m/c.
Replacement of Control Card including supply for 2 TR capacity Split/Window type AC m/c.
Replacement of Control Card including supply for 3 TR capacity Split/Window type AC m/c.
Replacement of Control Card including supply for 3.01 TR capacity Floor type AC
Replacement of Control Card including supply for 7.5 TR Ductable type AC m/c.
Fitting of 1/4 inch dia Copper tube per meter for Split/Window/Floor type AC m/c including supply of Copper Tube & Insulation.
Fitting of 1/2 inch dia Copper tube per meter for Split/Window/Floor type AC m/c including supply of Copper Tube & Insulation.
Fitting of 5/8 inch dia Copper tube per meter for Split/Window/Floor type AC m/c including supply of Copper Tube & Insulation.
Fitting of 3/8 inch dia Copper tube per meter for Split/Window/Floor type AC m/c including supply of Copper Tube & Insulation.
Fitting of Copper tube Insulation per meter with supply.
Replacement of Suction Valve for Split/Window/Floor type AC m/c including supply.
Replacement of Discharge Valve for Split/Window/Floor type AC m/c including supply.
Replacement of Thermostat Switch for 1 TR / 1.5 TR / 2 TR capacity Window/Split type AC m/c including supply.
Replacement of Thermostat Switch for 3 TR capacity Split type AC m/c including supply.
Replacement of Thermostat Switch for 3.01 TR capacity Floor type AC m/c including supply.
Replacement of Thermostat Switch for Refrigerator including supply of switch.
Fabrication of Frame with MS Flat, Angles, nut-bolts and then Erection & Mounting the Frame on wall for protection of 1 TR / 1.5 TR / 2 TR capacity Window type AC m/c, with supply of materials.
Fabrication of Frame with MS Flat, Angles, Erection & Mounting on wall for protection of 1 TR / 1.5 TR / 2 TR capacity Split type AC Outdoor Unit with supply of materials.
Replacement of Total Copper Condenser coil for I TR / 1.5TR Window type AC with supply.
Replacement of Total Copper Condenser coil for I TR / 1.5TR split type AC with supply.
Replacement of Total Copper Condenser coil for 2 TR window type AC with supply.
Replacement of Total Copper Condenser coil for 2 TR split type AC with supply.
Replacement of Total Copper Condenser coil for 3 TR split type AC with supply.
Replacement of Total Copper Cooling coil for I TR / 1.5TR Window type AC with supply.
Replacement of Total Copper Cooling coil for I TR / 1.5TR split type AC with supply.
Replacement of Total Copper Cooling coil for 2 TR window type AC with supply.
Replacement of Total Copper Cooling coil for 2 TR split type AC with supply.
Replacement of Total Copper Cooling coil for 3 TR split type AC with supply.
Repair of Copper Condenser coil for I TR / 1.5 TR / 2 TR Window type AC.
Repair of Copper cooling coil for I TR / 1.5 TR / 2 TR / 3 TR split type AC.
Replacement of Runner of I TR / 1.5 TR / 2 TR Split type AC with supply.
Replacement of Runner of 3 TR Split type AC with supply.
Replacement of Runner of I TR / 1.5 TR / 2 TR Window type AC with supply.
Replacement of Runner for 7.5 TR Ductable type AC with supply.
Replacement of Fan/Blower Motor for window type AC 1 TR Capacity with supply.
Replacement of Fan/Blower Motor for window AC 1.5 TR / 2 TR Capacity with supply.
Replacement of Fan/Blower Motor for Split AC 1 TR Capacity with supply.
Replacement of Fan/Blower Motor for Split AC 1.5 TR / 2 TR Capacity with supply.
Replacement of Fan/Blower Motor for Floor AC 3.01 TR Capacity with supply.
Replacement of Fan/Blower Motor for Split AC 3 TR Capacity with supply.
Replacement of Condensor Motor (Single phase, 0.5 HP)for Ductable AC of 7.5 TR Capacity with supply.
Replacement of cooling Motor (3 phase, 3 HP) for Ductable AC of 7.5 TR Capacity with supply.
Replacement of Starting Relay of Refrigerator with supply.
Replacement of Starting Relay for 1 TR / 1.5 TR / 2 TR Split/Window AC with supply.
Installation/Replacement of MCB at AC power line without supply of MCB.
Installation/Replacement of 2 pole MCB at AC power line with supply of MCB, Make Havells, Rating 25 Amp
Installation/Replacement of 3 pole MCB at AC power line with supply of MCB, Make Havells, Rating 25 Amp
Extension of Electrical wiring for AC machine with 4 sq mm Copper wire (Make: Havells) with earthing in PVC casing / pipe per meter with supply of the wire, casing etc. wiring materials per meter.
Replacement of Starting/Running Capacitor with supply for 1 TR Window/Split type AC.
Replacement of Starting/Running Capacitor without supply for 1 TR Window/Split type AC.
Replacement of Starting/Running Capacitor with supply for 1.5 TR Window/Split type AC.
Replacement of Starting/Running Capacitor without supply for 1.5 TR Window/Split type AC.
Replacement of Starting/Running Capacitor with supply for 2 TR Window/Split type AC.
Replacement of Starting/Running Capacitor without supply for 2 TR Window/Split type AC.
Replacement of Strainer Capillary with supply for 1 TR / 1.5 TR / 2 / 3 TR Split/Window Type AC machine.
Connection with supply of Drain pipe per meter for Split/Window/Floor type AC m/c of capacity 1 TR /1.5 TR /2 TR /3 TR.
AC machine Split / Window compressor repairing capacity 1 TR.
AC machine Split / Window compressor repairing capacity 1.5 TR / 2 TR.
AC machine Split compressor repairing capacity 3 TR.
AC machine compressor repairing for Ductable type capacity 7.5 TR [Make- Cobland].
Compressor repairing for refrigerator.
Replacement of compressor for refrigerator with supply
Supply & Filling of gas R-22 / Mafron for Window Type AC machine Capacity 1 TR.
Supply & Filling of gas R-22 / Mafron for Window Type AC machine Capacity 1.5 TR.
Supply & Filling of gas R-22 / Mafron for Window Type AC machine Capacity 2 TR.
Supply & Filling of gas R-22 / Mafron for Split Type AC machine Capacity 1 TR.
Supply & Filling of gas R-22 / Mafron for Split Type AC machine Capacity 1.5 TR
Supply & Filling of gas R-22 / Mafron for Split Type AC machine Capacity 2 TR
Supply & Filling of gas R-22 / Mafron for Split Type AC machine Capacity 3 TR
Supply & Filling of gas R-22 / Mafron for Floor Type AC machine Capacity 2 TR
Supply & Filling of gas R-22 / Mafron for Ductable Type AC machine Capacity 7.5 TR
Repairing/Rewinding of Blower Motor/Cooling Motor for Split/Window/Floor type AC Machine of capacity 1 TR /1.5 TR /2 TR /3 TR.
Repairing/Rewinding of Cooling Motor (3 phase, 3 HP) for Ductabler type AC Machine of capacity 7.5 TR.
Repairing/Rewinding of Condensor Motor (Single phase, 0.5 HP) for Ductable type AC Machine of capacity 7.5 TR.
Overhauling of Window A.C. machine Capacity 1 TR
Overhauling of Window A.C. machine Capacity 1.5 TR
Overhauling of Window A.C. machine Capacity 2 TR
Overhauling of Split A.C. machine Capacity 1 TR
Overhauling of Split A.C. machine Capacity 1.5 TR
Overhauling of Split A.C. machine Capacity 2 TR
Overhauling of Split A.C. machine Capacity 3 TR
Overhauling of Floor A.C. machine Capacity 3.01 TR
Overhauling of Ductable A.C. machine Capacity 7.5 TR
Overhauling of Refrigerator
Filter pad replacement of 1 TR / 1.5 TR Split/Window type AC Machine with supply
Filter pad replacement of 2 TR / 3 TR Split/Window/Floor type AC Machine with supply
Filter pad replacement of 7.5 TR Ductable type AC Machine with supply
Fan Blade replacement for Split / Window AC M/c of capacity 1 TR /1.5 TR /2 TR.
Fan Blade replacement for Split AC Machine of capacity 3 TR
Fan Blade replacement for Ductable type AC Machine of capacity 7.5 TR
Refrigerator Timer replacement with supply
Air filter checking and cleaning for Split / Window AC M/c of capacity 1 TR /1.5 TR /2 TR /3 TR.
Condenser coil, cooling coil cleaning& tit-bit jobs as required including cleaning of area of A.C machines
Electrical connection checking & rectification of minor Tit-Bit jobs regarding electric supply line.
Replacement of Front Grille for 1 TR /1.5 TR /2 TR window type AC m/c
Replacement of Flapper for 1 TR /1.5 TR /2 TR window/split type AC m/c
Replacement of Flapper motor/air swing motor for 1 TR /1.5 TR /2 TR window/split type AC m/c
V-Belt Replacement For 7.5 TR capacity Ductable type A.C.
Total Duct Cleaning For 7.5 TR capacity Ductable type A.C.
Servicing of KUCHINA MAKE kitchen Chimney, Cap.- 1400 m3/Hr
Servicing of KUCHINA MAKE kitchen Chimney, Cap.- 1200 m3/Hr
CARRION AIR COOLING
DIPSAN UDYOG
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .