Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.5 LAccepted-AOC | ₹37.5 L | L1 | Accepted-AOC Competent committee approved the tender in favour of Ist Lowest Bidder |
| 2 | L2₹40.3 L+₹2.8 L (7.40%)Rejected-AOC | ₹40.3 L+₹2.8 L (7.40%) | L2 | Rejected-AOC Competent committee rejected the file due to higher rates |
| Sl No | Description | Qty | Unit | M/S SAMAR ELECTRICALS L1 | M/S R.S. ENGINEERING TRADERS L2 |
|---|---|---|---|---|---|
| 1.00The work of safe carriage of the following material from CB Ganj store center to work site under the jurisdiction of EDD-Rampur Road, Bareilly. Approx. distance upto 80 Km. Including safe loading and unloading. | |||||
| 1.01 | PCC Pole 8.5 meter long. | 300 | Nos. | 900 ₹2,70,000 Lowest | 920 ₹2,76,000 |
| 1.02 | STP 9 Mtr Long | 40 | Nos. | 600 ₹24,000 Lowest | 700 ₹28,000 |
| 1.03 | STP 11 Mtr Long | 40 | Nos. | 900 ₹36,000 Lowest | 920 ₹36,800 |
| 1.04 | 11 KV Incoming Panel (VCB) | 4 | Nos. | 4,000 ₹16,000 Lowest | 5,000 ₹20,000 |
| 1.05 | 11 KV Outgoing Panel (VCB) | 4 | Nos. | 4,000 ₹16,000 Lowest | 5,000 ₹20,000 |
| 1.06 | LT Cable 1x240 sq mm | 40 | Mtr | 8 ₹320 Lowest | 9 ₹360 |
| 1.07 | LT Cable 1x400 sq mm | 40 | Mtr | 8 ₹320 Lowest | 9 ₹360 |
| 1.08 | Line material i.e., cross arm/ conductor/ pin insulator/stay/earthing rod/Disc Fitting/Disc Insulators/11 KV XLPE Cable etc | 400 | Qtl | 390 ₹1,56,000 Lowest | 410 ₹1,64,000 |
| 1.09 | 11/0.4 KV 1 Phase 10/16 KVA T/F | 6 | Nos. | 1,000 ₹6,000 Lowest | 2,000 ₹12,000 |
Tender Value
₹40 L
EMD Value
₹40,000
Closing Date
18 Oct 2025, 11:00 amClosed
SUPERINTENDING ENGINEER
ELECTRICITY DISTRIBUTION CIRCLE, KATJU MARG, BAREILLY
Running Contract forDeposit Works under EDD-Rampur Road, Bareilly
2025_MVVNL_1080050_1
19/EDCB/2025-26
Open Tender
Electrical Works
Item Rate
90 days
WORK
AS PER TENDER FORM
3 documents required · 3 mandatory
₹3,540
SE,EDC
₹40,000
8 Jun 2026
5 Oct 2025
18 Oct 2025
5 Oct 2025
18 Oct 2025
5 Oct 2025
Amount
The work of safe carriage of the following material from CB Ganj store center to work site under the jurisdiction of EDD-Rampur Road, Bareilly. Approx. distance upto 80 Km. Including safe loading and unloading.
PCC Pole 8.5 meter long.
STP 9 Mtr Long
STP 11 Mtr Long
11 KV Incoming Panel (VCB)
11 KV Outgoing Panel (VCB)
LT Cable 1x240 sq mm
LT Cable 1x400 sq mm
Line material i.e., cross arm/ conductor/ pin insulator/stay/earthing rod/Disc Fitting/Disc Insulators/11 KV XLPE Cable etc
11/0.4 KV 1 Phase 10/16 KVA T/F
11/0.4 KV 3 Phase 25 KVA T/F
11/0.4 KV 3 Phase 63 KVA T/F
11/0.4 KV 3 Phase 100 KVA T/F
11/0.4 KV 3 Phase 250 KVA T/F
11/0.4 KV 3 Phase 400 KVA T/F
11 KV Pilfer proof Metering cubical and CT PT Unit
33 KV Pilfer proof Metering cubical and CT PT Unit
Erection of new PCC Single/Double pole in H.T/L.T lines including fitting of all accessories as per RESSPO Norms
PCC Pole 8.5 Mtr Long Single Pole
PCC Pole 8.5 Mtr Long Double Pole
ST Pole 9 Mtr Long Single Pole.
ST Pole 9 Mtr Long Double Pole.
ST Pole 11 Mtr Long Single Pole.
ST Pole 11 Mtr Long Double Pole.
Grouting with 1:4:8 mixture in size(450x450x1500mm.) including cost of cement/BB & sand Required as per RESSPO Norms
PCC Pole 8.5 Mtr Long Single Pole
PCC Pole 8.5 Mtr Long Double Pole
ST Pole 9 Mtr Long Single Pole.
ST Pole 9 Mtr Long Double Pole.
ST Pole 11 Mtr Long Single Pole.
ST Pole 11 Mtr Long Double Pole.
The work of Driving the earthing electrode and making connections with 6 S.W.G. GI wire as per RESSPO Norms
Erection/Installation of following new panel (VCB) in control room including grouting of Anchor bolt of Panel and making/repairing of pocket for cable to insert in panel from trench and fixing, taping of bus bar with wiring for PT. AC, DC connection including providing of AC & DC Supply.
11 KV Incoming Panel (VCB)
11 KV Outgoing Panel (VCB)
Providing cutting, fixing and welding of MS Strip from existing, earthing to new 11 KV VCB Complete in all respect, all material shall be arranged by the Contractor.
Dismantling of Old and damaged conductor complete in all respect
Dismantling of PCC/ST Pole due to line shifting/damaged complete in all respect
Dismantling of Existing Distribution Transformer for increasing capacity/Shifting complete in all respect
11/0.4 KV 3 Phase 25 KVA T/F
11/0.4 KV 3 Phase 63 KVA T/F
11/0.4 KV 3 Phase 100 KVA T/F
11/0.4 KV 3 Phase 250 KVA T/F
11/0.4 KV 3 Phase 400 KVA T/F
Laying, Stringing & Sagging of Following Conductor complete in all respect
ACSR Weasal Conductor
ACSR Rabbit Conductor
ACSR Dog Conductor
3 Phase Arial Bunched Conductor
1 Phase Arial Bunched Conductor
LT Cable 1x240 sq mm
LT Cable 1x400 sq mm
After Mounting of CT PT unit on double pole, laying of 50 Mtr 11 KV 3cx70 sq mm cable in single circuit on river sand form Double Pole to metering room complete in all respect. Alongwith filling of 04 nos cable jointing kits
After Mounting of CT PT unit on double pole, laying of 50 Mtr 33 KV 3cx120 sq mm cable in single circuit on river sand form Double Pole to metering room complete in all respect. Alongwith filling of 04 nos cable jointing kits
Under ground laying of Following cable in Single circuit on river sand to Double pole situated at both sides of road complete in all respect. Minimum depth should be 0.75 Mtr and cable should be covered by bricks from three sides. Alongwith filling of 04 nos cable jointing kits
11 KV XLPE Cable Size 3x70 sqmm
11 KV XLPE Cable Size 3x120 sqmm
11 KV XLPE Cable Size 3x185 sqmm
33 KV XLPE Cable Size 3x120 sqmm
33 KV XLPE Cable Size 3x185 sqmm
33 KV XLPE Cable Size 3x300 sqmm
Under ground laying of Following cable in Single circuit by drill method to Double pole situated at both sides of NH/SH/Railway Crossing complete in all respect. Alongwith filling of 04 nos cable jointing kits
11 KV XLPE Cable Size 3x70 sqmm
11 KV XLPE Cable Size 3x120 sqmm
11 KV XLPE Cable Size 3x185 sqmm
33 KV XLPE Cable Size 3x120 sqmm
33 KV XLPE Cable Size 3x185 sqmm
33 KV XLPE Cable Size 3x300 sqmm
Hoisting of Following size 11 KV & 33 KV XLPE Cable on double pole with GI pipe of size 6 " dia 4 Mtr long including the jumpering complete with clamps , nut and bolts.
11 KV XLPE Cable Size 3x70 sqmm
11 KV XLPE Cable Size 3x120 sqmm
11 KV XLPE Cable Size 3x185 sqmm
33 KV XLPE Cable Size 3x120 sqmm
33 KV XLPE Cable Size 3x185 sqmm
33 KV XLPE Cable Size 3x300 sqmm
Supply & Laying of 6" dia G Pipe at various places i.e road crossing & Hoisting etc. complete in all respect ((ISO certified GI pipe 150 NB 3 mm thick dia 6" would be Provided by contractor at his own cost)
Construction of T/F plinth 1.5x1.5x2 m3 for mounting 250/400 KVA T/F including foundation work (below ground 0.5 M), Brick work, RCC slab of 4” thickness and plastering in 1:6 ratio with 02 Nos channel pieces of 1.5 mtr long of size 100x50x6 mm compete in all respect All manpower, material and T&P provided by the contractor to complete the work.
Cage fencing of 250/400 KVA Plinth mounted transformer in Town areas to avoid electrical human/cattle accidents by fabrication of cage (1 Inch Sq wiremesh) made of 10 No gauge in suitable size angle iron frame of size 7.5'(L)x5'(W)x8’(H) by strengthening of wire mesh 20x3 mm M.S. flat horizontally as well as vertically, Grouting the panel with 1:2:4 cement/coorse send/brick ballast. The Frame should be bolted on angles at the four corners so that frame may be un-bolted/bolted at the time of replacement of the transformer. Provision of 1 gate should be there for maintenance of the transformer. Painting (1 coat of red oxide + 2 coat of Bus green enamel paint). The wire mesh should be earthed with 50x6 mm MS earthing strip with existing earthing of Transformer Body. All manpower, material and T&P provided by the contractor to complete the fabrication, transportation and installation.
Pipe Earthing of Transformer (By boring of 4 inch diameter 20 m deep, 40 mm diameter A class GI pipe is inserted to a depth of 20 m and a holed pipe of 1.5 m length is inserted at the bottom. Tighten one end of the MS strip of size 50x6mm with the nut bolt with the neutral of the converter and weld the other end with the GI pipe inserted in the boring for earthing. Putting a socket on the upper part of the pipe (mouth) so that water can be poured into it to retain moisture. To complete the work Contractor will provide all material, Manpower, T&P, safe carriage of material to worksite. Above work will be carried out under supervision of concerned JE/SDO/EE)
The work of digging of pits, erection of Stay Clamp, Insulator etc.
Grouting of stays, 1:4:8 cc ratio (600x600x300mm.) as per RESPO norms.
Installation of 11 KV Pilfer Proof Metering Cubicle in metering room complete in all respect
Installation of 33 KV Pilfer Proof Metering Cubicle in metering room complete in all respect
Mounting of Following Capacity Transformers as per norms complete in all respect -
10/16 KVA T/F
25 KVA T/F
63 KVA T/F
100 KVA T/F
250 KVA T/F
400 KVA T/F
Fixing of Distribution Box complete in all respect
Guarding at road crossing complete in all respect
Supply & Fixing of Following Items to complete the work (If Not available in stores)
LT Clamps as per RESSPO Norms for PCC/ST pole
Nut & Bolt off size
F Clamp as per RESSPO Norms
Shackle Insulator as per RESSPO Norms
Holding Clamp as per RESSPO Norms
Stay Clamps as per RESSPO Norms
11 KV Composite Polymer Disc insulator as per RESSPO Norms
Top Channel of size 100x50x2240 mm as per RESSPO Norms
T off Channel as per RESSPO Norms
11 KV Polymer Pin Insulator as per RESSPO norms
Battery & Battery Charger 24 V
Aluminium Lug 240 sqmm with Nut&Bolt
Aluminium Lug 400 sqmm with Nut&Bolt
Safe back carriage of Scrap (if any) from work site to C.B. Ganj store Bareilly approx distance upto 80 Km including safe loading & unloading.
Safe back carriage of Distribution Transformer from work site to C.B. Ganj store Bareilly approx distance upto 80 Km including safe loading & unloading.
11/0.4 KV 3 Phase 25 KVA T/F
11/0.4 KV 3 Phase 63 KVA T/F
11/0.4 KV 3 Phase 100 KVA T/F
11/0.4 KV 3 Phase 250 KVA T/F
11/0.4 KV 3 Phase 400 KVA T/F
M/S R.S. ENGINEERING TRADERS (BID ID -5617609)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.68 MB
Tender_form.pdf
Tender Documents • 1.32 MB
BOQ_1975939.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .