Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹37.8 LAccepted-AOC | 1 | Accepted-AOC AWARDED BEING THE LOWEST TENDERER | |
| 2 | 2₹38.7 L+₹22,907.10 (0.60%)Rejected-Finance ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530001 | 2 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER | |
| 3 | 3₹41.9 L+₹3.4 L (8.90%)Rejected-Finance MIG 1 12 GULLALAPALEM VUDA COLONY SRIHARIPURAM MALKAPURAM POST VISAKHAPATNAM 530 011 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530011 | 3 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER | |
| 4 | 4₹42.9 L+₹4.4 L (11.5%)Rejected-Finance | 4 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER | |
| 5 | 5₹43.9 L+₹5.4 L (14.1%)Rejected-Finance 24 85 7 SANATH NAGAR GAJUWAKA VISAKHAPATNAM 530 026 | VISAKHAPATANAM | ANDHRA PRADESH | 530026 | 5 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER |
Tender Value
₹44.2 L
EMD Value
₹88,400
Closing Date
15 Nov 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER NAVAL BASE VISAKHAPATNAM
Garrison Engineer (Naval Base) Nausenabaugh Gandhigram PO Visakhapatnam 530 005
AS AND AS TO BLDG NO P-150 IN NEW NAUSENA BAUGH AND PROVN OF REAR WALL TO ASSEMBLY STAGE AT NCS SECONDARY AND PRIMARY WING AT NSB UNDER GE (NB) VISAKHAPATNAM
2022_MES_558445_1
C/8101/22-23/E8 / Token 71 of 2022-23
Open Tender
Civil Works
Item Rate
180 days
VISAKHAPATNAM
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GARRISON ENGINEER NAVAL BASE
₹88,400
Yes
1 Dec 2022
18 Oct 2022
17 Nov 2022
18 Oct 2022
15 Nov 2022
1 Nov 2022
Amount
Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water and removing rubbish to outside MD land complete all as specified and directed
Demolition of brick work or stone / boulder masonry, built in cement mortar including all quoins, pillars etc stacking the serviceable bricks after removing mortar and cleaning for re-use and disposal of debris and rubbish to a distance n.exc 100m as directed by the Engr-in-Charge.
M & L for Brick work with fly ash brick, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 using old size brick complete all as specified and directed.
M & L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished the surfaces even and fair without using extra cement complete all as specified and directed.
M & L for rendering 15 mm thick in two coats (10mm+5mm each) on fair faces of brick work or concrete surfaces in cement mortar 1:4, mixed with integral water proofing compound with weight of cement in top layer as per manufacturer's instructions and finished the surface even and fair without using extra cement complete all as specified and directed. (Note : WPC shall be measured and paid separately against respective item).
Supply only integral water proofing compound (ISI marked) complete all as specified and directed.
M & L for preparing newly plastered surfaces of internal walls, etc by "Vacuum based sandng machine" and applying two coats of Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification over a coat of alkali resistant primer by Auto Roller machine and over one or more coats of wall care putty to a smooth surface complete all as specified and directed. (Note: Multipurpose mixer shall be used for uniform and proper mixing of putty)
M & L for preparing old plastered surfaces of walls by complete removal of existing treatment "Vacuum based sandng machine" and applying two coats of Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification over a coat of alkali resistant priming coat by Auto Roller machine over one or more coat of wall care putty complete all as specified and directed. (Note: Multipurpose mixer shall be used for uniform and proper mixing of putty)
M & L for preparation new external surfaces of wall etc "Vacuum based sandng machine" and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces by "Auto Roller" machine complete all as specified and directed.
M & L for preparation old decorated external surfaces of wall, chajja, facia etc after complete removing old paints by mechanical scrubber without disturbing the plastered surfaces and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm by "Auto Roller" machine complete all as specified and directed.
Demolition of un-reinforced cement Concrete of any description and in any position not otherwise specifically provided for and removing rubbish to outside MD land complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and disposal of debris and rubbish to outside MD land complete all as specified and directed.
M & L for 30 mm thick, plain cement concrete 1:2:4, type B-1 (using 20 mm graded stone aggregate) as in sub-base of flooring, etc and finished the surface even and rough complete all as specified and directed.
M & L for preparing surfaces of sunken floor and applying a coat of Brush bond of M/s Fosroc Chemicals or equivalent approved water proofing coating as per manufacturer's instructions complete all as required and as directed.
M & L for injecting/grouting cement slurry mixed with Conbextra EP 10 (Epoxy resinj injection grout) of M/S Fosroc Chemicals or equivalent approved Chemicals in to roof/sunken slabs of toilet by drilling holes to a depth of 60mm by 20mm dia at 1 mtr interval by mechanical means with required pressure complete all as per manufacturer's instructions and as directed
M & L for rendering 10 mm thick in cement mortar 1:3 on fair faces of brick masonry or concrete surfaces and finishing the surfaces even and fair without using extra cement mixed with water proofing compound as per manufacturer's instructions complete all as specified and directed. (Note: WPC shall be measured and paid seperately)
M & L for Plain cement concrete 1:5:10, type E-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete, etc complete all as specified and directed.
M & L for non-skid, ceramic, coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.06 sqm but n.exc 0.11 sqm, in floors etc, including 15 mm thick screed bed in cement mortor 1:6 and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed.
M & L for glazed, coloured, ceramic, tiles of size (350mm x 250 mm/450mm x 350mm/300mmx450mm) x 6 to 7 mm thick, on vertical surfaces such as skirting, dados etc, including 10 mm thick bedding in cement mortor 1:4 and set & jointed in neat cement slurry & pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed.
M & L for Vitrified, designed, dark shade/double charged/ ultracharged coloured, tiles, 7 to 8 mm thick, (square/rectangular) polished, area of each tiles not exc 0.36 sqm, in floors, etc including 15 mm thick screed bed in cement mortor 1:6 and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed.
M & L for Vitrified, designed, dark shade/double charged/ ultracharged coloured, tiles, 7 to 8 mm thick, (square/rectangular) polished, area of each tiles not exc 0.36 sqm as in vertical surfaces such as skirting,dado, etc including 10 mm thick bedding in cement mortar 1:4 and necessary cutting of tiles complete all as specified and directed.
Demolition of reinforced cement concrete in any position not otherwise specifically provided for and removing rubbish to outside MD land complete all as specified and directed.
M & L for use & waste Form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizonal or sloping) for flat rough finished surfaces of concrete complete all as specified and directed.
M & L for Reinforced Cement Concrete M-30 Design Mix (Using 20 mm graded stone aggregate) as in slab supported on walls, beams and columns in floors, roofs, landings, balconies, and in shelves and the like etc complete all as specified and directed. (Note: Reinforcement will be measured and paid seperately)
S & F high strength corrosion resistant TMT steel bars 10 mm dia., and over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality complete all as specified and directed.
S & F high strength corrosion resistant TMT steel bars 6mm to 8mm dia., and over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality complete all as specified and directed.
M & L for 18 to 20mm thick Granite (of any type) work (table rubbed and polished), bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting a hole in the granite slab for gas pipe to any shap and rounding off exposed edges and polishing as in cooking platforms, water through, flooring, stair case and like including 3 Nos V grove over including 15 mm thick screed bed in cement mortor 1:6 & cutting, polishing complete all as specified and directed.
Dismantling 100mm bore, cast iron or reinforced concrete drain pipes jointed in cement mortar and taking out of trenches if required and as directed.
Dismantling 75mm bore, cast iron or reinforced concrete drain pipes jointed in cement mortar and taking out of trenches if required and as directed.
Taking up or down 15mm bore, Steel tubing and connections and keeping serviceable pipes in safe custody for reuse in the work after and including cleaning as directed.
Taking up or down 20mm bore, Steel tubing and connections and keeping serviceable pipes in safe custody for reuse in the work after and including cleaning as directed.
Taking up or down 25 or 32 mm bore, Steel tubing and connections and keeping serviceable pipes in safe custody for reuse in the work after and including cleaning as directed.
Supply, laying, connection and testing, 16mm outer dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed
Supply, laying, connection and testing, 20mm outer dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed
Supply, laying, connection and testing, 25mm outer dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed
S & F 75 mm bore, PVC (SWR), Soil waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors, etc complete all as specified and directed.
S & F 110 mm bore, PVC (SWR), Soil waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors, etc complete all as specified and directed.
S & F 75 mm bore, PVC (SWR), Soil, waste and vent pipes, single socketed in any length with rubber ring joints fixed to walls, etc complete all as specified and directed.
S & F 110 mm bore, PVC (SWR), Soil waste and vent pipes in any length with or without ears, with cement joints fixed to wall, etc with all necessary fixing arrangement complete all as specified and directed.
S & F 75 mm bore, PVC (SWR) bends of any radius with oval access door complete all as specified and directed.
S & F 110 mm bore, PVC (SWR) bends of any radius with oval access door complete all as specified and directed.
S & F 75 mm bore, PVC (SWR) bends of any radius complete all as specified and directed.
S & F 110 mm bore, PVC (SWR) bends of any radius complete all as specified and directed.
S & F 110 mm bore, PVC (SWR) vent cowl complete all as specified and directed.
S & F in repair 75 mm bore, PVC (SWR) floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed.
S & F in repairs Vitreous China Single piece-WC with PP Soft Seat cover, Hinges, Fixing Accessories Set and Accessories Set, Cistern fittings, Size: 370 x 690 x 680mm, S trap-300mm and all fittings and fixtures including connection to outgoing drain including making good damaged/disturbed surfaces complete all as specified and directed. (Make: Jaquar Cat No. CNS-WHT-851S300SPP or equivelant of make as per list of manufacturer's)
S & F in repairs, Vitreous China wash basin, Table Top Basin, Size: 630 x 425 x 160mm excluding taps but including CP waste coupling, PVC waste pipe fixed on granite slab complete all as specified and directed.(Make : Jaquar Cat No. JDS-WHT-25901 or equivalent of make as per List of manufacturer's)
S & F in repair 15 mm bore, Pillar Cock with 140mm Extension Body, fancy type, cast copper alloy, chromium plated, high pressure with all fittings, screwed for iron pipe complete all as specified and directed. (Make: Jaquar Cat No. LYR-38021 or equivelant of make as per list of manufacturer's)
S & F in repairs 15mm bore, Two Way Bib Cock with Wall Flange, fancy type cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. (Make: Jaquar Cat No. LYR-38041 or equivelant of make as per list of manufacturer)
S & F in repair 15 mm bore, Hand Shower (Health Faucet) with 8mm Dia, 1.2 Meter Long Flexible Tube & Wall Hook with all accessories complete all as specified and directed. (Make: Jaquar Cat No. ALD-573 or equivelant of make as per List of manufacturer's)
S & F in repair 15mm bore, Bib Cock with Wall Flange, fancy type cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. (Make: Jaquar Cat No. LYR-38037 or equivelant of make as per list of manufacturer)
S & F in repair 15 mm bore, angular stop cock with wall flange, cast copper alloy, chromium plated, fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. (Make: Jaquar Cat No. LYR-38053 or equivelant of make as per list of manufacturer)
S & F Toilet Roll Holder, brass, chromium plated fixed to wall with brass screw complete all as specified and directed. (Make: Jaquar Cat No. AKP-35751P or equivelant of make as per List of manufacturer's)
S & F Sun Disc Border Twin, decorative LED (3000K) Mirror, warm white light, round of size 30x30 inch, high quality LED mirror with touch sensor with one touch on/off, shadow less view, eneragy saving including all necessary fixing accessories and connecting up complete all as specified and directed. (Make: FlairGlass (of Saint Gobain) Cat No. SKU:LED-FG-RM-28W-3030 or equivelant models of make as per List of Manufacturer's)
S & F Soap Dispenser with Glass bottle, brass chromium plated, fixed in walls with plugs & chromium plated brass screws complete all as specified and directed. (Make: Jaquar Cat No. AKP-35735P or equivelant of approved make)
S & F Double Coat Hook chromium plated complete all as specified and directed. (Make: Jaquar Cat No. ACN-1161N or equivelant of make as per List of manufacturer's)
S & F in repairs 20 mm bore, Brass chromium plated, tubular towel rail, D type, 60 cm long between flanges with brackets complete all as specified and directed.
S & F in repairs, 15mm bore, PVC connection pipe 600mm long with PTMT nuts at both ends complete all as specified and directed.
Taking down chowkats or frame, n.exc 1.5 Sqm each with shutters (without taking off shutter from the frame) complete all as specified and directed.
Taking down chowkats or frames, exc 1.5 but n.exc. 4 Sqm in each with shutter (without taking off shutter from the frame) complete all as specified and directed.
S & F Solid PVC factory made solid PVC door frame of size 50 mm x 95 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube manufactured as per SSR Part I specifications and drawing complete all as specified and as directed
S & F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded, plain colour PVC 'C' channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, as per specification and drawing and as directed.
S & F 100 mm long, stainless steel butt hinges fixed with stainless steel hinge pin etc complete all as specified and directed.
S & F 150 mm long, Aluminium anodised, barrel tower bolts of extruded section complete all as specified and directed.
S & F 100 mm size, Extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
S & F Powder coated (minimum 50 micron) Anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. and anodised aluminium fittings such as peg stay 150mm long (01 No), hinge type B-21, 100mm long (02 Nos) and suitable size of handle complete all as specified and directed.
S & F PVC solid ventilators with frame size 55x47mm with wall thickness 5mm made out of extruded PVC sheet, mitre cut at corners and jointed with 2 Nos, 150mm long brackets of 15x15mm MS Square tube, the two vetted profiles are to be reinforced with 19x19mm MS square tube, 50% of bottom portion shall be fixed with 4mm thick pin headed glass and balance 50% of top portion shall be fixed with 4mm thick pin headed glass lowers and covered with 0.36mm dia stainless steel wire mesh at top portion including necessary PVC beading with screw and 3 Nos 12mm dia MS guard bars fixed in ventilator frame including two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer to MS guard bars and necessary fixtures complete all as specified and as directed.
S & F Powder coated (minimum 50 micron) Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed. (Note : (i) Thickness of aluminium section shall not be less than 1.5 mm).
S & F 5 mm thick, tinted sheet glass, ordinary quality and glazing with neoprene rubber beading for aluminium door/window etc in square exceeding 0.5 Sqm and n.exc 1Sqm in each pane complete all as specified and directed. (Note: The cost of neoprene rubber beads etc are already included with the cost of respective doors/windows)
M & L for 12 mm thick, Prelaminated particle board, exterior grade, prelaminated both side with decorative choice lamination fixed with screws to timber frame work complete all as specified and directed.
S & F Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
Providing and fixing Powder coated Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineerin-charge complete all as specified and directed.
S & F Aluminium alloy anodised sliding door bolt with hasp & staple (bolt type) and fixing clipes of sheet, cast or extruded sections and fixing bolts of extruded sections or cast aluminium alloy, length of bolt of 300 mm complete all as specified and directed.
S & F 125 mm long, stainless steel butt hinges fixed with stainless steel hinge pin etc complete all as specified and directed.
S & F 150 mm size, extruded Aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
S & F Aluminium (Die cast) body door Closer hydraulically regulated, designation No 3, universal type, suitable for door shutter of 851 to 1000 mm in width and of weight between 61 to 80 Kg complete all as specified and directed.
S & F 100 mm, 4 lever, Brass, Mortice Lock, vertical type complete all as specified and directed.
Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 m in depth for foundation, etc and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm as in soft/loose soil complete all as specified and directed.
Removing excavated materials exc 1.5 Km but n. exc 5 Km and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed.
M & L for Plain cement concrete 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete, etc complete all as specified and directed.
M & L for use & waste Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundations and plinth beams and similar work, vertical or to batter complete all as specified and directed.
M & L for use & waste Formwork to sides of pillars, posts, struts, piers, columns and stanchions for flat rough finished surfaces of concrete complete all as specified and directed.
M & L for Reinforced Cement Concrete M-30 (Design Mix) (using 20 mm graded stone aggregate) as in foundations including rafts, footings, beams and mass concrete, etc complete all as specified and directed. (Note" Reinforcement will be measured and paid seperately)
M & L for Reinforced Cement Concrete M-30 (Design Mix) (using 20 mm graded stone aggregate) as in columns, pillars, posts and struts complete all as specified and directed. (Note : Reinforcement will be measured & paid seperately)
S & F high strength corrosion resistantMild steel TMT bars 5mm dia and over upto and including 10mm dia in strirrups, spacers and binders spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips etc complete all as specified and directed.
M & L for Rolled mild steel fo grade Fe 410-W (Gde-E- 250) quality-A as in Stairs (framed) including stringers, treades, landing, balusters, hand rails etc. including cleats, brackets, etc. complete complete all as specified and directed.
S & F Rolled mild steel in Plates (plain or chequered) channels fo grade Fe 410-W (Gde-E- 250) quality-A, square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as speicfied and directed.
S & F Mild steel screw bolts of 11 to 15 mm diameter of shank (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 5cm and n exc 10cm long complete all as specified and directed.
M & L for Rolled mild steel fo grade Fe 410-W (Gde-E- 250) quality-A as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat section) including distance pices, cleat etc complete all as specified and directed.
S & F Mild steel screw bolts of 11 to 15mm dia of shank (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 10cm and n. exc 15cm long complete all as specified and directed.
S & F Pre-Painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as per manufacturer's instruction complete all as specified and directed.
S & F Pre-Painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridges/vally gutter, fixed with self tapping screws as per manufacturer's instruction complete all as specified and directed.
M & L for Preparation of new steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide, zine chrome primer complete all as specified and directed.
S & F 1000 litres capacity rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top), hoisted and fixed in position including taking down old unserviceable one as specified in SSR Part I and directed.
S & F in repairs, 20 mm bore, Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight - 210 gms) complete all as specified and directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc.) any thickness including cover fillets/snap grid etc complete all as specified and directed.
S & F aluminium Anodised snap grid frame work of size 605mm x 605mm frame work for ceiling with aluminium T section of size 38mm x 25mm x 1.5mm thick for main runners, 25x25x1.5mm thick for cross runner and angle size 25x25x1.5mm thick alongwith wall suspended and including Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to ceiling members in proper position, fixed with aluminium staple on snap grid as per manufacturer's instructions complete all as specified and directed by the Engr-in-Charge.
M & L for Providing and fixing Gypsum Board, 12mm thick in ceiling fixed with screw as per manufacturers instructions complete all as specified and directed.
M & L for preparing new surfaces of ceiling, etc by "Vacuum based sandng machine" and applying two coats of distemper oil emulsion over a coat of alkali resistant primer by "Auto Roller" machine complete all as specified and directed.
M & L for use & waste Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etcetc complete all as specified and directed.
M & L Reinforced Cement Concrete M-30 (Design Mix) (using 20 mm graded stone aggregate) as in beams, cantilevers, lintels over 1.5m span complete all as specified and directed. (Note : Reinforcement will be measured & paid seperately)
Excavating in post holes (or similar holes) each n. exc 0.5 Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers n. exc 25cm, watering and removing surplus soil to a distance n. exc 50m and making good surface in hard/dense soil complete all as specified and directed.
M & L for Plain cement concrete 1:3:6, type C-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete, etc complete all as specified and directed.
S & F MS steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S. 1161-1979 grade St-240 complete all as speicfied and directed.
Taking down carefully unserviceable aluminium/copper point wiring (light, fan, socket or power) complete, (fitting such as switches, ceiling roses, pendants, regulators, sockets, etc to be measured separately if found serviceable), removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.
Taking down unserviceable main switches, DBs, bus bars chambers any capacityincluding all fittings and fixtures such as MCBs, isolator, etc and removing from site complete all as specified and directed.
Taking down unserviceable sub-main wiring (any numbers of cable) with rigid PVC/steel conduits/PVC casing-caping including cutting chases for conduits and making good disturbed surfaces complete all as specified and directed.
M & L for Point wiring with two runs of single core 1.5 Sq.mm. (Nominal area) PVC insulated unsheathed multistranded copper conductor cable FRLS (ISI marked) drawn through and including non metallic PVC conduit 20 mm bore (Minimum) medium grade (ISI marked) concealed type including metal GI boxes of suitable module including modular white cover plate of suitable module for fixing modular type switches, sockets, regulators etc. including provision of multistranded 1.5 Sq.mm copper conductor cable FRLS [ISI marked] as earth wire connected to common earth dolly and earth in distribution board complete all as specified and as directed, for one light/exhaust fan/fan point/call bell controlled by one way switch. (Note.: (i) The rate quoted is deemed to include making good the disturbed sufaces and to match the adjoining surface. (ii) The quoted rate is deemed to include cutting chases for concealed wiring including making good the same as per the existing one)
All as per item No. 109 above but for One 3/5 pin socket outlet 6 amps on independent board complete ditto
All as per item No. 109 above but for One 3/5 pin socket outlet 6 amps point on same board complete ditto
All as per item No. 109 here in before but for one 15 Amps power point on the independent board with two runs of PVC insulated and unsheathed copper conductor cable of size 2.5 sqmm multistranded FRLS (ISI marked) and 2.5 sqmm PVC insulated unsheathed solid copper conductor cable FRLS (ISI marked) as earth lead complete ditto
S & F switch modular single pole one way 6 amp 240 volts,1 Module complete all as specified and as directed.
S & F switch modular single pole one way 16 amp 240 volts,1 Module complete all as specified and as directed.
S & F Modular socket outlet 6A, 2/3 pin combined, 2 module, AC 230V, 50HZ complete all as specified and as directed.
S & F Modular socket outlet 6A/16A, 2/3 pin combined, 2 module, AC 230V, 50HZ complete all as specified and as directed.
S & F ceiling rose, 65 X 50mm two to three terminals, PVC/polycarbonate, insolated body complete all as specified and directed.
S & F steped type modular fan regulator ,100/120 W 1/ 2 module complete all as specified and as directed.
S & F Concealed sheet metal enclosure with socket plug top and MCBs having single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 20Amp 240V, B-curve complete all as specified and as directed.
M & L for Sub main wiring with 2 runs of Single core 1.5 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including concealed PVC conduit of suitable size (medium grade) with all conduit accesories and fittings along with 1 run of single core 1.5 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- (i) Two runs of 1.5 sqmm and one runs of 1.5 sqmm cable as earth wire and one run of conduit shall be measured as one length, (ii) The quoted rate is deemed to include cutting chases for concealed wiring including making good the same as per the existing one)
M & L for Sub main wiring with 2 runs of Single core 2.5 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including concealed PVC conduit of suitable size (Medium grade) with all conduit accesories and fittings along with 1 run of single core 2.5 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- (i) Two runs of 2.5 sqmm and one runs of 2.5 sqmm cable as earth wire and one run of conduit shall be measured as one length, (ii) The quoted rate is deemed to include cutting chases for concealed wiring including making good the same as per the existing one )
M & L for Sub main wiring with 2 runs of Single core 4 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including concealed PVC conduit of suitable size (medium grade) with all conduit accesories and fittings along with 1 run of single core 4 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- (i)Two runs of 4 sqmm and one runs of 4 sqmm cable as earth wire and one run of conduit shall be measured as one length, (ii) The quoted rate is deemed to include cutting chases for concealed wiring including making good the same as per the existing one )
M & L for Sub main wiring with 2 runs of Single core 6 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including concealed PVC conduit of suitable size (medium grade) with all conduit accesories and fittings along with 1 run of single core 6 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- Two runs of 6 sqmm and one runs of 6 sqmm cable as earth wire and one run of conduit shall be measured as one length, (ii) The quoted rate is deemed to include cutting chases for concealed wiring including making good the same as per the existing one)
S & F Vertical DB double door for provision for four pole MCCB upto 250A incommer 8 way 24 outgoing with IP 43 protection complete all as specified and as directed. (Make : Legrand cat part No. 5077 59 or equivelant of make as per List of manufacturer's)
S & F Vertical TPN DB double door for provision for four pole MCCB upto 160 A incommer 4 way 12 outgoing with IP 43 protectioncomplete all as specified and as directed. (Make : Legrand cat part No. 5077 45 or equivelant of make as per List of manufacturer's)
S & F Distribution Board, SPN 12 Way, 240V, Double door with IP 43 protection, IK 09 complete all as specified and as directed. (Make: Legrand cat part No. 5076 12 or equivalent make as per List of Manufacturer's)
S & F Distribution Board, SPN 8 Way, 240V, Double door with IP 43 protection IK 09 complete all as specified and as directed. (Make: Legrand cat part No. 5076 11 or equivalent make as per List of Manufacturer's)
Supply, fixing, commissioning and testing MCB SP 6 to 32 Amps, 240 Volts, 10KA, C Curve, complete all as specified and as directed (Make: Legrand cat part No. 4085 87 to 95 or equivalent make as per List of Manufacturer's)
Supply, fixing, commissioning and testing MCB SPN 6-32A Amps, 240 Volts, 10KA, C Curve complete all as specified and as directed (Make: Legrand cat part No. 4086 14 to 17 or equivalent make as per List of Manufacturer's)
Supply, fixing, commissioning and testing MCB SPN 40-63 Amps, 240 Volts, 10KA, C curve complete all as specified and as directed (Make: Legrand cat part No. 4086 18 to 20 or equivalent make as per List of Manufacturer's)
S & F 2x2 recessed mounting, LED panel light fittings, 36 Watt with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including tube lamp complete all as specified and directed. (Make: Havell's Cat No. VENUSNEOHE2X2R36WLED840PIRSENSOR or equivelant of make as per list of manufacturer)
S & F LED tube light fittings, retro bar professional WH 5700K to 6000K, 20 Watt and 2000 Lumens of cool white with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including tube lamp complete all as specified and directed. (Make: Havell's Cat No. LUMILINEPLUSBS20WLED865SPCSS or equivelant of make as per list of manufacturer)
S & F Surface and wall mounted LED batten, 10W, 220V, AC, 2 feet, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver with industrial grade heavy duty driver having THD<10% including lamp, fixing accessories and connecting up complete all as specified and directed. (Make : Havell's Cat No. ENDURALINEARNEOBS10WLED865SPCWH and equivelant model of make as specified in list of manufacturer).
S & F LED outdoor Security light fittings, Min IP 65 rated, aluminium die cast housing with powder coating, pole mounted, 30 Watt, Lumen ≥ 3000, Luminous afficacy ≥ 100 Lum/Watt, CCT:WW/NW/CW, CRI > 70 Ra, 4KV surge Protection with open and short circuit protections as per IS: 10322 with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including lamp complete all as specified and directed. (Make: Jaquar Cat No. JQM-GRY-LSRT015030XC or equivelant of make as per list of manufacturer)
S & F in repairs stationary louvers suitable for exhaust fan of 300mm sweep made out of powder coated aluminium anodised sheet of Min 1mm thick with non removable blades fixed permanantly at 45 degree angle for protection from rain including aluminium wire mesh of suitable size for bird control Complete all as per the existing specification and as directed. (Note: Louver has to fixed upto sixty metre height multistoried building. The unit quoted rate shall deemed to be inclusive of necessary scafolding and safety measure for fixing of louver upto 15 metre height. No extra claim on this account shall be entertained later on)
M & L for Earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to galvanized steel earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in Electrical Plate No 3 of SSR Part - I, including necessary excavation and earth work, P.C.C (1:3:6) type C-I with 50 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab (reinforced with 8 mm dia deformed bar @ 10 cm C/C both ways and suitable handle of 12 mm dia round bar), including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (light grade), wire mesh, aluminium lugs, complete in all respect, GI earth wire protected by 15 mm bore (medium grade) galvanized iron pipe and other end connected with main switch board or Earthing test point as directed, including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessary testing on completion inclduing taking down old one complete all as specified and as directed by the Engineer-in-Charge.
Taking down carefully by unscrewing from boards/outlet boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and regulators, etc. for reuse at site or carrying to the store (To be measured only when found serviceable in all respects complete for reuse) complete all as directed.
Fixing only serviceable light fittings any type including connecting up complete all as specified and directed (Note: Old serviceable light fittings as obtained from serial Item No 137 here -in-before shall be re-used).
Taking down ceiling fan / exhaust fan/wall mounted fan, any sweep from the site and replacing the defective parts such as shakle & clamps including, rubber bush, bolts, nuts & split pin (Chera Pin), washer etc. for ceiling fan and ensure proper inserting the quarter/ Split pin to hold the nut and bolt on fan downrod at fix position including servicing, oiling and greasing and re-fixing the ceiling fan / exhaust fan/ wall mounted of any sweep again at existing site all as specified and as directed
SRI SRK ENGINEERS
S A R CONSTRUCTIONS
M/s VENKATA JAHNAVI CONSTRUCTIONS
V R K CONSTRUCTIONS
SRI VENKATA SAI MANIKANTA CONSTRUCTIONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .