Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.5 LAccepted-AOC 224 OFFICERS ENCLAVE BEHIND PLV MEMORIAL COLLEGE SHIKARGARH ARMY AREA JODHPUR RAJ 342001 | JODHPUR | RAJASTHAN | 342001 | L1 | Accepted-AOC Lowest Bidder, Hence accepted | |
| 2 | L2₹18.9 L+₹16,026 (0.86%)Rejected-Finance 77 KAILASH PURI BIKANER RAJ C 15 SWC JAIPUR | BIKANER | RAJASTHAN | 331801 | L2 | Rejected-Finance Not Lowest Bidder, Hence Rejected |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
14 Mar 2022, 6:00 pmClosed
GE (AF) Phalodi
Military Engineer Services Garrison Engineer (AF) Near Kundal Village, Phalodi (Rajasthan)-342 301
REPAIR AND MAINTENANCE OF AIR CONDITIONERS, WATER COOLERS, REFRIGERATORS, DEEP FREEZERS AND CONNECTED ITEMS AT AF STN PHALODI
2022_MES_507856_1
8405
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (AF) Phalodi
E Class c (i)
7 documents required · 7 mandatory
₹500
GE (AF) Phalodi
₹50,000
2 May 2022
14 Feb 2022
16 Mar 2022
14 Feb 2022
14 Mar 2022
28 Feb 2022
Amount
M & L for servicing and maintenance of split type AC's of capacity 1 TR/ 1.5 TR/ 2.0 TR comprising of the following works & installed at different locations & including testing, painting of outdoor unit and including writting MES Nos with black synthetic enamel paint (height of letters not less than 10mm) on indoor and outdoor unit complete all as specified and directed :- (i) Inspecting and checking the Indoor/outdoor units for noise free operation. (ii) Checking the electrical connection for tightness. (iii) Cleaning the condenser with cleaning agent followed with pressurized water and cleaning the cooling coil with air blower. (iv) Greasing/Oiling of condenser fan motor and blower motor. (v) Checking for any refrigerant leakage. (vi) Checking for serviceability of remote control unit. Note:- (i) Any parts found unserviceable/defective shall be measured and paid separately under respectively item (here-in-after) of BOQ. (ii) Make of parts shall be as per original & Genuine make of AC. (iii) Make(s) of AC's to be repaired are specified in Appx 'D'. (Voltas, Hitachi, Lloyd, Godrej, Bluestar)
All as per Srl Item No 1.00 (here-in-before) but for Vertical/Tower type AC's of capacity 3.0 TR complete all as specified and directed.
All as per Srl Item No 1.00 (here-in-before) but for VRF 18.0 TR AC complete all as specified and directed.
S & F in renewal of capacitor combo running 45+2 mfd for split type AC unit as per existing as required at Site complete all as specified and directed.
S & F in renewal of running capacitor 45 mfd for split type AC unit as per existing as required at Site complete all as specified and directed.
S & F in renewal of running capacitor combo 50+6 mfd for split type AC's of capacity 1.5/2.0 TR complete all as specified and directed.
S & F in renewal of running capacitor 50 mfd for split type AC's of capacity 1.5/2.0 TR complete all as specified and directed.
S & F in renewal of indoor blower fan motor, single phase, 230 Volt of split type AC Suitable for 1.5 TR capacity complete all as specified and directed.
S & F in renewal of indoor blower fan motor, single phase, 230 Volt of split type AC Suitable for 2.0 TR capacity complete all as specified and directed.
S & F in renewal of burnt compressor of capacity 2.0 TR of split type AC unit make original compressor as per existing Rotary Type Make & Model and including gas charging complete all as specified and directed. Note :- (i) Cost of Refrigerant gas (R-22/R-410A/R-32) shall be deemed to be included in the quoted rate. (ii) Empty /filled cylinder shall be responsibility of contractor and contractor shall liable for all risk against the same.
S & F in renewal of burnt compressor of capacity 1.5 TR of split type/ Window type ACs unit and re-fixing the same after renewal from the company make original compressor as per existing Rotary Type Make & Model and including gas charging complete all as specified and directed. Note :- (i) Cost of Refrigerant gas (R-22/R-410A/R-32) shall be deemed to be included in the quoted rate. (ii) Empty /filled cylinder shall be responsibility of contractor and contractor shall liable for all risk against the same.
M & L for repair to leaking area of split type AC unit of capacity 2.0 TR and including dehydration, gas charging of gas R22/R410A/R-32 as applicable, pressure check & testing complete all as specified and directed. Note :- (i) Cost of Refrigerant gas (R-22/R-410A/R-32) shall be deemed to be included in the quoted rate. (ii) Empty /filled cylinder shall be responsibility of contractor and contractor shall liable for all risk against the same.
M & L for repair to leaking area of split type / Window type AC unit of capacity 1.5 TR and including dehydration, gas charging of gas R22/R410A/R-32 as applicable, pressure check & testing complete all as specified and directed. Note :- (i) Cost of Refrigerant gas (R-22/R-410A/R-32) shall be deemed to be included in the quoted rate. (ii) Empty /filled cylinder shall be responsibility of contractor and contractor shall liable for all risk against the same.
S & F in renewal of air filter of indoor unit for split type AC units of capacity 1.5/2.0 TR as per existing Make & Model complete all as specified and directed.
S&F in renewal of insulation for Split AC Copper Tube 5/8 inch with Nitrile rubber insulation tube of OD thickness 10mm and length 6 ft per piece (minimized heat gain and loss, Good condensation control) followed with clamps complete all as specified and directed.
S&F in renewal of insulation for Split AC Copper Tube 1/2 inch with Nitrile rubber insulation tube of OD thickness 10mm and length 6 ft per piece (minimized heat gain and loss, Good condensation control) followed with clamps complete all as specified and directed.
S&F in renewal of insulation for Split AC Copper Tube 1/4 inch with Nitrile rubber insulation tube of OD thickness 10mm and length 6 ft per piece (minimized heat gain and loss, Good condensation control) followed with clamps complete all as specified and directed.
S & F in renewal of 3 core copper PVC insulated FRLSH cable of size 4.0 Sqmm, flexible cables, 1100 Volts and confirming to IS: 694 complete all as specified and directed.
S & F in renewal of swing motor of indoor unit as per existing Make & model for split type AC, 1.5 TR complete all as specified and directed.
S & F in renewal of swing motor of indoor unit as per existing Make & model for split type AC, 2.0 TR complete all as specified and directed.
S & F in renewal of suction line (1/4") copper pipe or suitable size as per existing dia and length with Nitrile Rubber protection as required at site complete all as specified and directed.
S & F in renewal of discharge line (5/8") copper pipe or suitable size as per existing dia and length with Nitrile Rubber protection as required at site complete all as specified and directed.
S & F in renewal of discharge line (1/2") copper pipe or suitable size as per existing dia and length with Nitrile Rubber protection as required at site complete all as specified and directed.
S & F in renewal of PCB as per existing Make & model for Split type AC of Capacity 2.0 TR/ 1.5 TR complete all as Specified and Directed.
S & F in renewal of electronic cordless remote control unit as per existing Make & model of split type AC's of capacity 1.5/2.0 TR complete all as specified and directed.
S & F in renewal of Flexible PVC drain pipe of size 15mm bore & suitable for Split type AC of Capacity 1.5/2.0 TR complete all as specified and directed.
S & F in renewal of outdoor unit fan blade as per existing Make and model & suitable for Split type AC of Capacity 1.5 TR complete all as Specified and directed.
S & F in renewal of outdoor unit fan blade as per existing Make and model & suitable for Split type AC of Capacity 2.0 TR complete all as Specified and directed.
S & F in renewal of outdoor unit condenser fan motor as per existing Make & model and suitable for 1.5 TR capacity air conditioner complete all as specified and directed.
S & F in renewal of outdoor unit condenser fan motor as per existing Make & model and suitable for 2.0 TR capacity air conditioner complete all as specified and directed.
S & F in renewal of indoor unit complete set (Refrigerant Compatibility R22, R410A & R-32) with & including cordless remote, compatable with all BEE Star Ratings AC's, copper tubes in evaporator coil as per existing Make & model & suitable for 1.5 TR capacity air conditioner and including gas charging complete all as specified and directed. Note :- (i) Cost of Refrigerant gas (R-22/R-410A/R-32) shall be deemed to be included in the quoted rate. (ii) Empty /filled cylinder shall be responsibility of contractor and contractor shall liable for all risk against the same.
S & F in renewal of indoor unit complete set (Refrigerant Compatibility R22, R410A & R-32) with & including cordless remote, compatable with all BEE Star Ratings AC's, copper tubes in evaporator coil as per existing Make & model & suitable for 2.0 TR capacity air conditioner and including gas charging complete all as specified and directed. Note :- (i) Cost of Refrigerant gas (R-22/R-410A/R-32) shall be deemed to be included in the quoted rate. (ii) Empty /filled cylinder shall be responsibility of contractor and contractor shall liable for all risk against the same.
S & F in renewal of outdoor unit (Refrigerant Compatibility R22, R410A & R-32) without compressor, Compressor compatibility; Rotary or Reciprocating both as per existing Make & model & suitable for 1.5 TR capacity air conditioner and including gas charging complete all as specified and directed. Note :- (i) Cost of Refrigerant gas (R-22/R-410A/R-32) shall be deemed to be included in the quoted rate. (ii) Empty /filled cylinder shall be responsibility of contractor and contractor shall liable for all risk against the same.
S & F in renewal of outdoor unit (Refrigerant Compatibility R22, R410A & R-32) without compressor, Compressor compatibility; Rotary or Reciprocating both as per existing Make & model & suitable for 2.0 TR capacity air conditioner and including gas charging complete all as specified and directed. Note :- (i) Cost of Refrigerant gas (R-22/R-410A/R-32) shall be deemed to be included in the quoted rate. (ii) Empty /filled cylinder shall be responsibility of contractor and contractor shall liable for all risk against the same.
S & F in renewal of copper condenser coil as per existing and suitable for 1.5 TR capacity of air conditioner, outdoor unit, ISI marked and including gas charging complete all as Specified and directed. Note :- (i) Cost of Refrigerant gas (R-22/R-410A/R-32) shall be deemed to be included in the quoted rate. (ii) Empty /filled cylinder shall be responsibility of contractor and contractor shall liable for all risk against the same.
S & F in renewal of copper condenser coil as per existing and suitable for 2.0 TR capacity of air conditioner, ISI marked and including gas charging complete all as Specified and directed. Note :- (i) Cost of Refrigerant gas (R-22/R-410A/R-32) shall be deemed to be included in the quoted rate. (ii) Empty /filled cylinder shall be responsibility of contractor and contractor shall liable for all risk against the same.
S & F in renewal of Low pressure valve as per existing Make & model of size 1/4 inch, ISI marked complete all as specified and directed.
S & F in renewal of Low pressure valve as per existing Make & model of size 1/2 inch, ISI marked complete all as specified and directed.
S & F in renewal of Low pressure valve as per existing Make & model of size 5/8 inch, ISI marked complete all as specified and directed.
S & F in renewal of four way valve as per existing Make & model and suitable for 2.0 TR / 1.5 TR capacity of air conditioner, ISI marked complete all as specified and directed.
S&F in renewal of AC refrigerant charging Pin NRV Valve
S & F in renewal of wall mounted outdoor metal bracket of size 36 inch of heavy duty of minimum weight 5.50 Kg and Load capacity of 50 kgs for outdoor unit of split AC's 1.5/2.0 TR capacity with & including connected accessories viz fastner, nuts and bolts complete all as specified and directed.
S & F in removal in shifting of Split AC's of capacity 1.5/2.0 TR with indoor, outdoor and including all the connected accessories after pumping down the gas, refitting, topping up the gas, testing and commissioning complete all as specified and directed.
S & F in renewal of ducting insulation sheet (9mm thick) for insulating refrigeration pipe line for 1.5/2.0 TR capacity of air conditioner complete all as specified and directed.
S & F in renewal of brass flare union connector 5/8 inch (Pack of 4) for gas pipe line connection both in 1.5/2.0 TR capacity of Split Type AC complete all as specified and directed.
S & F in renewal of brass flare union connector 1/2 inch (Pack of 4) for gas pipe line connection both in 1.5/2.0 TR capacity of Split Type AC complete all as specified and directed.
S & F in renewal of brass flare union connector 1/4 inch (Pack of 4) for gas pipe line connection both in 1.5/2.0 TR capacity of Split Type AC complete all as specified and directed.
S & F in renewal of brass flare nut 5/8 inch (Pack of 4) for gas pipe line connection both in 1.5/2.0 TR capacity of Split Type AC complete all as specified and directed.
S & F in renewal of brass flare nut 1/2 inch (Pack of 4) for gas pipe line connection both in 1.5/2.0 TR capacity of Split Type AC complete all as specified and directed.
S & F in renewal of brass flare nut 1/4 inch (Pack of 4) for gas pipe line connection both in 1.5/2.0 TR capacity of Split Type AC complete all as specified and directed.
M & L for repair and maintenance of window type AC's of capacity 1.5 TR comprising of the following works at different locations & including refixing, commissioning, testing, painting of AC's and including writting MES Nos with black synthetic enamel paint (height of letters not less than 10mm) complete all as specified and directed :- (i) Inspecting, taking down, brushing cleaning with blower & including acid/detergent wash of condenser and cooling coil. (ii) Carry out running test of operation of blower and compressor and ensure that satisfactory functioning of all parts. (iii) Inspecting for leakage in the system. (iv) Checking the earth continuity of electrical parts. (v) Checking the functioning of thermostat. (vi) Inspection of all electrical parts. (vii) Testing the machine for satisfactory operation. Note:- (i) Any parts found unserviceable/defective shall be measured and paid separately under respectively item (here-in-after) of BOQ. (ii) Make of parts shall be as per original make of window type AC. (iii) Make(s) of AC's to be repaired are specified in Appx 'D'. (Voltas, Hitachi, Voltas, Bluestar)
S & F in renewal of air filter of window type AC of capacity 1.5 TR as per existing Make & Model as required at site complete all as specified and directed. Make :- Coir foam or equivalent Make ISI Marked as approved.
Disconnecting & taking down of window type AC of any Make and Re-fixing the same after renewal of cooling coil as per existing Make and Model & including soldering/welding, commissioning & testing complete all as specified and directed.
Disconnecting & taking down of window type AC of any Make and Re-fixing the same after renewal of condenser coil as per existing Make and Model & including soldering/welding, commissioning & testing complete all as specified and directed.
S & F in renewal of fan and blower motor as per existing Make & Model and suitable for window air conditioner of capacity 1.5 TR complete all as specified and directed.
S & F in renewal of blower as per existing Make & Model and suitable for window air conditioner of capacity 1.5 TR complete all as specified and directed.
S & F in renewal of fan blade as per existing Make & Model and suitable for window air conditioner of capacity 1.5 TR complete all as specified and directed.
M & L for repair & maintenance of water coolers of capacity 40/80 Ltrs comprising of the following works at different location and including painting and including writting MES Nos with black synthetic enamel paint (height of letters not less than 10mm) complete all as specified and directed :- (i) Inspection, taking down, opening, dismantling, descaling, brushing & cleaning of storage tanks. (ii) Examination water tightness, leak proof of storage tank after cleaning. (iii) Carry out operation of all stop cock, push cock, float valve etc. (iv) Inspect overflow and remove blockage if any. (v) Check and correct earth continuity of electric items. (vi) Check thermostat and test its functioning. (vii) Inspect drain pipe and remove blockage if any. (viii) Check and correct all electrical wiring & test its functioning. (ix) Testing of water cooler after repair. Note:- (i) Any parts found unserviceable/defective shall be measured and paid separately under respectively item (here-in-after) of BOQ. (ii) Make of parts shall be as per original make of water coolers. (iii) Make(s) of water cooler to be repaired are all as specified in Appx 'D'. (Usha Sriram, Voltas, Bluestar)
All as per Srl Item No 58.00 (here-in-before) but for water coolers of capacity 60/120 Ltrs complete all as specified and directed.
S & F in renewal of thermostat switch as per existing Make & Model for water cooler of any Capcity complete all as specified and directed.
S & F in renewal of overload protector relay as per existing Make & Model for compressor of water cooler of any capacity as reqd at site complete as specified and directed.
Disconnecting and rewinding of condenser fan motor, single phase of 1/30 HP as per existing for water cooler of capacity 40/80 Ltrs & re-fixing the same with clamps, bolts, nuts and rubber bushes & including connecting & testing complete all as specified and directed.
Disconnecting and rewinding of condenser fan motor, single phase of 1/20 HP as per existing for water cooler of capacity 60/120 Ltrs & re-fixing the same with clamps, bolts, nuts and rubber bushes & including connecting & testing complete all as specified and directed.
S & F in renewal of condenser fan motor, single phase of 1/30 HP as per existing Make and Model & suitable for water cooler of capacity 40/80 Ltrs complete all as specified and directed.
S & F in renewal of condenser fan motor, single phase of 1/20 HP as per existing Make and Model & suitable for water cooler of capacity 60/120 Ltrs complete all as specified and directed.
S & F in renewal of 15mm bore brass float valves accessories as per existing Make and Model & suitable for water coolers at site, ISI marked complete all as specified and directed.
Disconnecting and taking down water coolers of capacity 40/80 Ltrs & 60/120 Ltrs of any make and size for repairs & including detection of leakage in the system rectifying the same, dehydration & recharging of gas (R-22/R-134A/Environmental Friendly Gas) suitable for compressor model & testing the water cooler for smooth & satisfactory operation complete all as specified and directed. Note :- (i) Cost of Refrigerant gas (R-22/R-134A/Environmental Friendly Gas) shall be deemed to be included in the quoted rate. (ii) Empty /filled cylinder shall be responsibility of contractor and contractor shall liable for all risk against the same.
S & F in renewal of CP push cock of size 15mm dia as per existing Make & model, ISI marked complete all as specified and directed.
S & F in renewal of capacitor 10 Mfd as per existing Make & model, ISI marked for water cooler of any capacity complete all as specified and directed.
M & L for repair rusted body as per existing of water cooler and replacing MS sheet and fixing new MS sheet (size upto 1.50 Sqm) thickness 21 SWG by remitting/gas welding and including renewal of angle iron of size 35mm x 35mm x 4mm (Minimum Weight-2.5 Kg) and including painting complete all as specified and directed.
S & F in renewal of burnt compressor as per existing original Make & model and suitable for water cooler of capacity 40/80 Ltrs and including gas charging complete all as specified and directed. Note :- (i) Cost of Refrigerant gas (R-22/R-134A/Environmental Friendly Gas) shall be deemed to be included in the quoted rate. (ii) Empty /filled cylinder shall be responsibility of contractor and contractor shall liable for all risk against the same.
S & F in renewal of burnt compressor as per existing original Make & model and suitable for water cooler of capacity 60/120 Ltrs and including gas charging complete all as specified and directed. Note :- (i) Cost of Refrigerant gas (R-22/R-134A/Environmental Friendly Gas) shall be deemed to be included in the quoted rate. (ii) Empty /filled cylinder shall be responsibility of contractor and contractor shall liable for all risk against the same.
M & L for repair & maintenance of Refrigerator of capacity 180 Ltrs to 340 Ltrs comprising of the following works at different location and writting MES Nos with black synthetic enamel paint (height of letters not less than 10mm) complete all as specified and directed :- (i) Inspecting, taking down, brushing cleaning with blower including acid/detergent wash of condenser and cooling coil. (ii) Carry out operation of blower and compressor and ensure that satisfactory functioning of all parts. (iii) Inspecting the leakage in the system. (iv) Checking of the earth continuity of electrical parts. (v) Checking the functioning of thermostat. (vi) Inspection of all electrical parts. (vii) Testing the machine for satisfactory operation. (viii) Check and correct all electrical wiring & test its functioning. (ix) Testing of Refrigerator after repair. Note:- (i) Any parts found unserviceable/defective shall be measured and paid separately under respectively item (here-in-after) of BOQ. (ii) Make of parts shall be as per original make of Refrigerator. (iii) Make(s) of Refrigerators to be repaired are specified in Appx 'D'. (Bluestar, Voltas, Samsung, LG, Whirlpool)
S & F in renewal of burnt compressor as per existing Company Make original & model and suitable for refrigerator of capacity 165-190 Ltrs and including gas charging complete all as specified and directed. Note :- (i) Cost of Refrigerant gas (R-134A/Environmental Friendly Gas) shall be deemed to be included in the quoted rate. (ii) Empty /filled cylinder shall be responsibility of contractor and contractor shall liable for all risk against the same.
S & F in renewal of burnt compressor as per existing Company Make original & model and suitable for refrigerator of capacity 280-350 Ltrs and including gas charging complete all as specified and directed. Note :- (i) Cost of Refrigerant gas (R-134A/Environmental Friendly Gas) shall be deemed to be included in the quoted rate. (ii) Empty /filled cylinder shall be responsibility of contractor and contractor shall liable for all risk against the same.
Disconnecting and taking down refrigerator (165 to 320 Ltrs Cap) of any make and size for repairs & including detection of leakage in the system rectifying the same, dehydration & recharging of gas (R-134A/ Environmental Friendly Gas) & testing the refrigerator for smooth & satisfactory operation complete all as specified and directed. Note :- (i) Cost of Refrigerant gas (R-134A/Environmental Friendly Gas) shall be deemed to be included in the quoted rate. (ii) Empty /filled cylinder shall be responsibility of contractor and contractor shall liable for all risk against the same.
M & L for repair & maintenance of Deep Freezer of capacity 200 to 320 Ltrs comprising of the following works at different location and including writting MES Nos with black synthetic enamel paint (height of letters not less than 10mm) complete all as specified and directed :- (i) Inspecting, taking down, brushing cleaning with blower including acid/detergent wash of condenser and cooling coil. (ii) Carry out operation of blower and compressor and ensure that satisfactory functioning of all parts. (iii) Inspecting the leakage in the system. (iv) Checking of the earth continuity of electrical parts. (v) Checking the functioning of thermostat. (vi) Inspection of all electrical parts. (vii) Testing the machine for satisfactory operation. (viii) Check and correct all electrical wiring & test its functioning. (ix) Testing of Refrigerator after repair. Note:- (i) Any parts found unserviceable/defective shall be measured and paid separately under respectively item (here-in-after) of BOQ. (ii) Make of parts shall be as per original make of Deep freezer. (iii) Make(s) of Deep Freezer to be repaired are specified in Appx 'D'. (Voltas, Blustar)
S&F in renewal fan motor of deep freezer 16 watts, 230 Volts single phase.
M & L for repair and servicing of Voltage Stabilizer of capacity upto 5 KVA complete all as specified and directed.
S & F in renewal of single pole and neutral sheet metal enclosure with a two pin and earth plug and socket and including one MCB SPN 20 Amps, 240 Volt, MCB, 'C' curve type with AC box, rupturing capacity 10 KA complete all as specified and directed.
S & F in renewal of MCB single pole 6 to 32 Amp, 'C' curve having rupturing capacity 10 KA conforming to IS-8828-1996, IEC-60898, complete all as specified & directed.
S & F in renewal of metal clad plug 2P+E for all type of AC's as per existing Make and size complete all as specified & directed.
S & F in renewal of metal clad socket 2P+E for all type of AC's as per existing Make and size complete all as specified & directed.
S&F in renewal of AC Changeover Guard ATM Timer (Response time 16 ms) should prevent Low Voltage start, having Compressor Lockout/ Anti-Short Cycle timer, Should eliminate relay xchatter due to thermostat bounce or tampering. Make: Totaline, Powercool, Ryoku.
M/S SOLANKI GENERAL SUPPLIERS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .