| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.2 LAccepted-AOC PLOT NO 3 DIVINE SCHOOL ROAD NEAR BJP KARYALAY PORBANDAR KHAMBHALIYA HIGHWAY BOKHIRA PORBANDAR 360 579 | PORBANDAR | GUJARAT | 360579 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹30.8 L+₹1.2 L (3.91%)Rejected-Finance 0 HISAR HISAR HARYANA 125004 UDYAM HR 06 0052049 | HISAR | HARYANA | 125004 | L2 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹74,000
Closing Date
10 Jun 2025, 6:00 pmClosed
GE Navy Porbandar
GE Navy Porbandar Tija Mile Porbandar
REPAIR / MAINT OF INDOOR AND OUTDOOR UNITS OF WINDOW / SPLIT AIR CONDITIONERS AT VARIOUS LOCATION AND REPAIR / REPLACEMENT OF CERTAIN COOLING AND REFRIGIRATION APPLIANCES AND ALLIED WORKS AT TECHNICAL AREA PORBANDAR UNDER GE NAVY PORBANDAR
2025_MES_701468_2
9290/PBR/E8
Open Tender
Electrical and Maintenance Works
Item Rate
334 days
GE Navy Porbandar
Please refer Tender Documents
7 documents required · 7 mandatory
₹500
Garrison Engineer Navy
₹74,000
22 Jul 2025
8 May 2025
12 Jun 2025
8 May 2025
10 Jun 2025
22 May 2025
8 May 2025 - 21 May 2025
Amount
Labour for servicing of Window AC's upto 1.50 Tonne capacity of any make, complete health check-up of the unit and carrying out 2 dry & 1 wet service by removing dust with blower, complete cleaning of unit using cleansing solution ,soap /water, checking all connections , Lubrication of fan motor and other parts as and when required and identifying faults and making the Air conditioner fully functional & serviceable complete all as specified & directed by Engineer-in-Charge.
Labour for servicing of split AC's upto 1.50 Tonne capacity of any make, complete health check-up of the unit indoor /outdoor and carrying out 2 dry & 1 wet service by removing dust with blower, complete cleaning of outer & indoor unit using cleansing solution ,soap /water, checking all connections , Lubrication of fan motor and other parts as and when required and identifying faults and making the split AC fully functional complete all as specified & directed by Engineer-in-Charge.
Labour for servicing of split AC's of 2.0 Tonne capacity of any make , complete health check-up of the unit indoor /outdoor and carrying out 2 dry & 1 wet service by removing dust with blower, complete cleaning of outer & indoor unit using cleansing solution ,soap /water checking all connections , Lubrication of fan motor and other parts as and when required and identifying faults and making the split AC fully functional complete all as specified & directed by Engineer-in-Charge.
Labour for servicing of Cassette AC's of capacity 2.0 Tonne, complete health check-up of the unit indoor /outdoor and carrying out 2 dry & 1 wet service by removing dust with blower, complete cleaning of outer & indoor unit using cleansing solution ,soap /water checking all connections , Lubrication of fan motor and other parts as and when required and identifying faults and making the split AC fully functional complete all as specified & directed by Engineer-in-Charge.
Labour for servicing of Cassette AC's of capacity 3.0 Tonne, complete health check-up of the unit indoor /outdoor and carrying out 2 dry & 1 wet service by removing dust with blower, complete cleaning of outer & indoor unit using cleansing solution ,soap /water checking all connections , Lubrication of fan motor and other parts as and when required and identifying faults and making the split AC fully functional complete all as specified & directed by Engineer-in-Charge.
Material and labour for Detecting the gas leakage, using nitrogen & soap solution, rectifying the defects by sealing the leakage by brazing/repair of part, vacumizing and charging fresh mafron gas/R-22/ F-134A / R-32as per requirement and commissioning and testing the window type air conditioner of 1.5 Ton capacity complete all as specified and directed.
Material and labour for Detecting the gas leakage, using nitrogen & soap solution, rectifying the defects by sealing the leakage by brazing/repair of part, vacumizing and charging fresh mafron gas/R-22/ F-134A / R-32as per requirement and commissioning and testing the split type air conditioner upto 1.5 Ton capacity complete all as specified and directed.
Material and labour for Detecting the gas leakage, using nitrogen & soap solution, rectifying the defects by sealing the leakage by brazing/repair of part, vacumizing and charging fresh mafron gas/R-22/ F-134A / R-32as per requirement and commissioning and testing the split type air conditioner of 2.0 Ton capacity complete all as specified and directed.
Material and labour for Detecting the gas leakage, using nitrogen & soap solution, rectifying the defects by sealing the leakage by brazing/repair of part, vacumizing and charging fresh mafron gas/R-22/ F-134A / R-32as per requirement and commissioning and testing the Cassette type air conditioner of 2 Ton capacity complete all as specified and directed.
Material and labour for Detecting the gas leakage, using nitrogen & soap solution, rectifying the defects by sealing the leakage by brazing/repair of part, vacumizing and charging fresh mafron gas/R-22/ F-134A / R-32as per requirement and commissioning and testing the Cassette type air conditioner of 3 Ton capacity complete all as specified and directed.
M&L for dismantling of indoor,outdoor unit of Split AC of any make , capacity complete from existing location and fixing it to a new location,making all connections , making good of old location, complete testing & commisioining all as specified & directed by Engineer-in-Charge.
S& F in replacement of air conditioner outdoor unit stand consisting of wall brackets with fasteners suitable for all brands air conditioner outdoor units, Load carrying capacity for 2 ton outdoor unit , Rust proof sturdy design in powder coated metal with accessories for installation complete all as specified and directed.
M& L for taking down AC to workshop & replacement unserviceable rotary compressor suitable for window air condtioner of capacity upto 1.5 TR , fixing,assembling & refixing AC back to location complete testing for good cooling and smooth functioning to the satisfaction of Engr-in-charge ,& complete all as specified and directed.
M& L for taking down outdoor , indoor unit of AC to workshop & replacement unserviceable rotary compressor suitable for split air condtioner of capacity upto 1.5 TR , fixing ,assembling & refixing of AC back to location complete, testing for good cooling and smooth functioning to the satisfaction of Engr-in-charge , complete all as specified and directed.
M& L for taking down outdoor , indoor unit of AC to workshop & replacement of rotary compressor suitable for split air condtioner of capacity 2.0 TR, fixing ,assembling & refixing of AC back to location complete, testing for good cooling and smooth functioning to the satisfaction of Engr-in-charge , complete all as specified and directed.
M& L for taking down outdoor , indoor unit of AC to workshop & replacement of rotary compressor suitable for Cassette of capacity upto 3 .TR , fixing ,assembling & refixing of AC back to location , testing for good cooling and smooth functioning to the satisfaction of Engr-in-charge , complete all as specified and directed.
S& F in replacement of blower motor suitable for split type Air conditioner upto 1.5 Ton capacity complete all as specified and directed.
S& F in replacement of blower motor suitable for split type Air conditioner 2.0 Ton capacity complete all as specified and directed.
S& F in replacement of louver motor suitable for split type Air conditioner upto 2.0 Ton capacity complete all as specified and directed.
S& F in replacement of thermostat switch,sensor suitable for split type Air conditioner upto 2.0 Ton capacity complete all as specified and directed.
S& F in replacement of PCB circuit boards suitable for split type Air conditioner upto 2.0 Ton capacity complete all as specified and directed.
S& F in replacement of display PCB suitable for split type Air conditioner upto 2.0 Ton capacity complete all as specified and directed.
M& L for taking down indoor unit of AC to workshop & replacement of evaporator coil suitable for split type Air conditioner upto 1.5 Ton capacity fixing ,assembling & refixing of AC back to location testing for good cooling & smooth functioning all as specified and directed by Engr-in charge
M& L for taking down indoor unit of AC to workshop & replacement of evaporator coil suitable for split type Air conditioner 2.0 Ton capacity fixing ,assembling & refixing of AC back to location testing for good cooling & smooth functioning all as specified and directed by Engr-in charge
S& F in replacement of blower suitable for split type Air conditioner upto 2.0 Ton capacity complete all as specified and directed by Engr-in charge
S& F in replacement of remote handset with cell suitable for split type Air conditioner upto 2.0 Ton capacity complete all as specified and directed by Engr-in charge
S& F in replacement of outdoor unit fan motor from window / split type AC of capacity 1.5 / 2 Ton and replacing the same with brand new fan motor of same capacity including connecting up and testing complete all as specified and directed.
M& L for taking down outdoor , indoor unit of AC to workshop & replacement of condensor coil suitable for split type Air conditioner upto 1.5 Ton capacity fixing ,assembling & refixing of AC back to location testing for good cooling & smooth functioning all as specified and directed by Engr-in charge
M& L for taking down outdoor , indoor unit of AC to workshop & replacement of condensor coil suitable for split type Air conditioner 2.0 Ton capacity fixing ,assembling & refixing of AC back to location testing for good cooling & smooth functioning all as specified and directed by Engr-in charge
S& F in replacement of suction/discharge valve suitable for split type Air conditioner 2.0 Ton capacity complete all as directed by Engr-in charge
S& F in replacement of capilary tube filter set suitable for air conditioner upto 2 TR capacity complete iall as specified and directed by Engr-in charge
S& F in replacement of fan blade suitable for window/split type Air conditioner of 1.5 Ton capacity complete all as specified and directed.
S& F in replacement of fan blade suitable for window/split type Air conditioner of 2.0 Ton capacity complete all as specified and directed.
S& F in repair of PCB circuit boards for split type Air conditioner upto 2.0 Ton capacity complete all as specified and directed.
S& F in replacement of PCB circuit boards for inverter split type Air conditioner upto 2.0 Ton capacity complete all as specified and directed.
S& F in replacement capacitor upto 3 MFD 230 volts, 50 Hz, type suitable for window/split air conditioner of capacity upto 2TR complete above complete all as specified and directed by Engr-in charge
S& F in replacement capacitor above 3 MFD & upto 60 MFD 230 volts, 50 Hz, type suitable for window/split air conditioner of capacity upto 2TR complete above complete all as specified and directed by Engr-in charge
S& F in replacement PVC front grill suitable for window type room AC of make Carrier/Voltas/Usha suitable complete all as specified and directed by Engr-in charge
S& F in replacement return air filter made of PVC suitable for window air conditioner of capacity upto 2TR complete mentioned above complete all as specified and directed by Engr-in charge
S& F in replacement of magnetic contactor 240V 26/20A 440V, 50Hz suitable for split ac 1.5/2 type & capacity fixed in complete all as specified and directed.
S& F in replacement of foam heat insulating flexible hollow tube for suction and discharge tubes of 1.5/2 Ton capacity split AC complete all as specified and directed.
S& F in replacement 3 core X 1.5 Sqmm PVC insulated and FR PVC Round sheathed, copper conductor, flexible industrial cable,1100 V conforming to IS :694 all as specified and directed by Engr-in charge Make: Standrad/Polycab/Finolex
S& F in replacement 3 core X 2.5 Sqmm PVC insulated and FR PVC Round sheathed, copper conductor, flexible industrial cable,1100 V conforming to IS :694 all as specified and directed by Engr-in charge Make: Standrad/Polycab/Finolex
S& F in replacement 6A, 240V, 3Pin Plug top all as specified and directed by Engr-in charge Make: Standrad/Havells Reo
S& F in replacement 16A, 240V, 3Pin Plug top all as specified and directed by Engr-in charge Make: Standrad/Havells Reo
S & F in replacement of earth enclosure with 2 pin earth plug sokcet complete with MCB SP 25 amp,flush mounting type all as specified and directed by Engr-in charge Make: Standrad/Havells Reo
S& F in replacement PVC pipe 20 mm dia heavy duty inclusive of all tees,bends, elbows etc & fixing accessories for drain out condensing water of split AC including cutting of floor/opening of hole in wall and making good after laying of pipe etc to match the existing surface complete.
S & F in replacement of PVC pipe 25 mm dia heavy duty inclusive of all tees,bends, elbows etc & fixing accessories for drain out condensing water of split AC including cutting of floor/opening of hole in wall and making good after laying of pipe etc to match the existing surface complete.
S & F in replacement of clamping jointing copper tubing of size 1/4",1/2", 3/8" ,5/8" for suction line and for liquid discharge line duly insulated with suitable insulation material including making hole in wall for passing through and making good to the disturbed surface complete all as specified and directed.
Repairs to refrigerator of capacity upto 240 Ltr of any make by taking down unserviceable compressor , S&F hermatically sealed compressor with Relay and OLP unit, mounting bush suitable for above mentioned capacity refrigerator with one year warranty, fixing & assembling in refrigerator ,vacuming and gas charging with R-134a /Hydrocarbon gas per pressure and quantity recommended by the company, testing for good cooling & smooth functioning to the satisfaction of Engr-in-charge etc complete all as specified and directed Note:- Rate is inclusive of compressor & required gas charging
Repairs to refrigerator of capacity above 240 & upto 320 Ltr of any make by taking down unserviceable compressor , S&F hermatically sealed compressor with Relay and OLP unit, mounting bush suitable for above mentioned capacity refrigerator with one year warranty, fixing & assembling in refrigerator ,vacuming and gas charging with R-134a /Hydrocarbon gas per pressure and quantity recommended by the company, testing for good cooling & smooth functioning to the satisfaction of Engr-in-charge etc complete all as specified and directed Note:- Rate is inclusive of compressor & required gas charging
Material and labour in replacement of outdoor unit Grill for Air Condiening Split AC for suitable size of 1.5 /2 ton complete all as specified and directed.
Material and labour in replacement of door rubber seal/ gasket refrigerator of capacity upto 180-240 Ltr of any make complete all as specified and directed.
Material and labour in replacement of Led bulb 10 watt for refrigerator of capacity upto 180- 240 Ltr of any make complete all as specified and directed.
Material and labour of split AC Polycarbonate water & dustproof indoor split AC Cover of any make complete all as specified and directed.
S & F in replacement of open type relay with Over load protector suitable for refrigerator of capacity upto 320 Ltr all as specified and directed by Engr-in charge
S & F in replacement of thermostatic switch defrost type including plastic regulating knob suitable refrigerator of capacity upto 320 Ltr all as specified and directed by Engr-in charge
S & F in replacement of set of copper strainer with silica filter suitable refrigerator of capacity upto 320 Ltr all as specified and directed by Engr-in charge
S & F in replacement of capillary tube 0.036'' maximum suitable refrigerator of capacity upto 320 Ltr all as specified and directed by Engr-in charge
S & F in replacement of running capicitor , Cap 4 MFD suitable for refrigerator .Make : Epcos all as specified and directed by Engr-in charge
S & F in replacement of running capicitor , Cap 6 MFD suitable for refrigerator .Make : Epcos all as specified and directed by Engr-in charge
S & F in replacement of running capicitor , Cap 10 MFD suitable for refrigerator .Make : Epcos all as specified and directed by Engr-in charge
S & F in replacement of condensor coil suitable refrigerator of capacity upto 320 Ltr ,fitting & assembling in refrigerator and including gas charging with R-134a /Hydrocarbon R600a as per pressure and quantity recommended by the company,testing for good cooling and smooth functioning all as specified and directed by Engr-in charge
S & F in replacement of evaporator /cooling coil with frame suitable refrigerator of capacity upto 320 Ltr, fitting & assembling in refrigerator and including gas charging with R-134a/Hydrocarbon R600a gas per pressure and quantity recommended by the company, testing for good cooling & smooth functioning all as specified and directed by Engr-in charge
S & F in replacement of non return valve suitable for refrigerator/Watercooler/Deep freezer all as specified and directed by Engr-in charge
Material and labour for Detecting the gas leakage, using nitrogen & soap solution, rectifying the defects by sealing the leakage by brazing/repair of part, vacumizing and charging fresh gas/R-22/ F-134A / R-32 as per requirement and commissioning and testing the refrigerator upto 320 Ltr capacity complete all as specified and directed.
Repairs to Deep freezer of capacity upto 400 Ltr of any type & make by taking down unserviceable compressor and S&F New hermetically sealed compressor with Relay and OLP unit suitable for above mentioned capacity with one year warranty , fixing & assembling in deepfreezer complete with welding /brazing and gas charging with R-134a gas as per the pressure and quantity directed, testing for good cooling and smooth functioning to the satisfaction of Engr-in-charge , complete all as specified and directed. Note:- Rate is inclusive of compressor & required gas charging.
S & F in replacement of starting capacitor of capacity 80-100 Mfd suitable for deep freezer of capacity upto 400 Ltr complete all as specified and directed by Engr-in charge Make:-EPCOS
S & F in replacement of thermostat switch suitable for deep freezer suitable for deep freezer of capacity upto 400 Ltr complete all as specified and directed by Engr-in charge
S & F in replacement of over load protector with relay and capacitor set suitable for deep freezer of capacity upto 400 Ltr complete all as specified and directed by Engr-in charge
S & F in replacement of capillary tube 0.044'' dia for deep freezer suitable for deep freezer of capacity upto 400 Ltr complete all as specified and directed by Engr-in charge
S & F in replacement of copper strainer silica filter for deep freezer suitable for deep freezer of capacity upto 400 Ltr complete all as specified and directed by Engr-in charge
S & F in replacement of fan motor condenser 230 volts, 8 to 10 watts suitable for deep freezer of capacity upto 400 Ltr complete all as specified and directed by Engr-in charge
Material and labour for Detecting the gas leakage, using nitrogen & soap solution, rectifying the defects by sealing the leakage by brazing/repair of part, vacumizing and charging fresh gas/R-22/ F-134A / R-32 as per requirement and commissioning and testing the Deepfrezzer upto 400 Ltr capacity complete all as specified and directed.
Repairs to Water Cooler of capacity of any type & make by taking down unserviceable compressor and S&F New hermetically sealed compressor with Relay and OLP unit suitable for water cooler with one year warranty , fixing & assembling in water cooler complete with welding /brazing and gas charging with R-134a gas as per the pressure and quantity directed, testing for good cooling and smooth functioning to the satisfaction of Engr-in-charge , complete all as specified and directed. Note:- Rate is inclusive of compressor & required gas charging.
S & F in replacement of pencil drier type strainer suitable for water cooler of any type & capacity complete all as specified and directed by Engr-in charge
S & F in replacement of Box type Relay with over load protector suitable for water cooler of any type & capacity complete all as specified and directed by Engr-in charge
S & F in replacement of running capacitor upto 15 MFD 230 Volts AC 50 Hz suitable for water cooler of any type & capacity complete all as specified and directed by Engr-in charge Make: EPCOS
S & F in replacement of starting capacitor upto 40-60 MFD 230 volts , 50 Hz suitable for water cooler of any type & capacity complete all as specified and directed by Engr-in charge
S & F in replacement of thermostat switch with plastic regulating knob suitable for water cooler of any type & capacity complete all as specified and directed by Engr-in charge
S & F in replacement of fan motor capacity 1/35 HP of condenser suitable for water cooler of any type & capacity complete all as specified and directed by Engr-in charge
S & F in replacement of float valve 15 mm bore dia complete with PVC ball ,brass chromium plated rod suitable for water cooler mentoned above complete all as specified and directed by Engr-in charge
S & F in replacement of PVC connection pipe, type 15 mm dia 450 mm long complete with PVC union at both end suitable for water cooler of any type & capacity complete all as specified and directed by Engr-in charge
S & F in replacement of PVC flexible connection pipe high density 32 mm dia including jublee clamps ouutlet connection for drain water suitable for water cooler of any type & capacity complete all as specified and directed by Engr-in charge
S & F in replacement of spring loaded self closing water tap ( push type) 15 mm bore dia , internal theaded , brass chromium plated suitable for water cooler of any type & capacity complete all as specified and directed by Engr-in charge
S & F in replacement of spring loaded self closing water tap ( push type) 15 mm bore dia, External threaded , brass chromium plated suitable for water cooler of any type & capacity complete all as specified and directed by Engr-in charge
Material and labour for Detecting the gas leakage, using nitrogen & soap solution, rectifying the defects by sealing the leakage by brazing/repair of part, vacumizing and charging fresh gas/R-22/ F-134A / R-32 as per requirement and commissioning and testing the watercooler of any capacity complete all as specified and directed.
S & F in replacement filter catridge suitable upto 25 ltrs RO Plant including taking out old filter cartridge complete all as specified and directed.
S & F in replacement filter catridge suitable for 50 ltrs RO Plant including taking out old cartridge complete all as specified and directed.
S & F in replacement RO memebrane suitable upto 25 ltrs RO Plant including taking out old RO membrane complete all as specified and directed.
S & F in replacement RO memebrane suitable 50 ltrs RO Plant including taking out old RO membrane complete all as specified and directed.
S & F in replacement RO inlet valve for all type of RO Plant including taking out old RO Inlet valve complete all as specified and directed.
S & F in replacement RO solenoid valve for RO Plant including taking out old RO solenoid valvecomplete all as specified and directed.
S & F in replacement Plastic pipe for RO, UV & water purifiess 1/4 size for all type of RO Plant including taking out old Plastic pipe for RO, UV & water purifiess complete all as specified and directed.
S & F of Stickers duly marked as GE (NAVY) PBR (MES) of size 2'' width & 10 '' Length and paste over all AC's , Refrigerators, Water coolers, RO's & Geysers, The colour & Font of sticker as specified and directed by Engr-in-charge.
RAJ ENTERPRISE (BID ID -3303875)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .