Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.8 LAccepted-AOC HARIBHAVAN NORTH ARIYAD P O ALAPPUZHA | L1 | Accepted-AOC L1 | |
| 2 | L2₹7.1 L+₹29,532.90 (4.31%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹7.7 L+₹83,279 (12.2%)Rejected-AOC NALLOOR H NALUKODY P O CHANGANCHERRY | L3 | Rejected-AOC L3 | |
| 4 | L4₹7.8 L+₹92,625 (13.5%)Rejected-AOC CHANGANACHERRY GENERAL ELECTRICAL WORK | L4 | Rejected-AOC L4 |
Tender Value
Refer Docs
EMD Value
₹20,300
Closing Date
15 Jan 2021, 6:00 pmClosed
Executive Engineer
PWD Electrical Division Civil Station Alappuzha
Supply and providing Street lights in Nursing College to Boys Hostel at Govt. Nursing College, Vandanam, Alappuzha
2021_PWD_404478_1
EDA/D1-2018/1259
Open Tender
Electrical Works
Item Rate
30 days
Vandanam- Alappuzha
Please refer Tender documents.
5 documents required · 5 mandatory
₹1,800
₹20,300
18 Mar 2021
7 Jan 2021
19 Jan 2021
7 Jan 2021
15 Jan 2021
7 Jan 2021
Amount
street light
od47474/2018_2019 : Supply , conveyance, erection testing and commissioning of Octagonal pole Height 7 mtr Top dia 70mm Bottom dia 155mm having sheet thickness 3mm base plate 250 x 250 x 16 mm with 4x24 mm Dia 750mm foundation bolts and with Single arm bracket 1.5 mtr long The Octagonal pole shall be hot dip galvanized in single section with Bakelite sheet with one 6A SP MCB and 16 sq mm stud type connector including Reiforced Cement concrete foundation of size not less than 500x500x2000mm etc. complete
od47476/2018_2019 : Supply,installation of 70W LED Street light fittings with aluminium casting,toughed glass cover,assemetric beam angle of 130x50 degree with typical luminare efficiecy>85 lumen per watt,IP66 protection on existing GI pipe and giving connection(BRTFG 72WLED Bajaj or rquivalent)
90.12.1.40 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).4 core 10 sq mm
90.12.5.40 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 10 sq mm
90.12.7.40 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp
90.12.9.2 : Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size
9.1.32 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
od47482/2018_2019 : Supply and laying bare earthing conductors of the 3.15 mm copper conductor (10 SWG) laid 0.6 m below ground level including excavating trench of suitable size and refilling etc. as required (in ordinary soil).
90.11.1.15 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
2.23.1 : Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with testing and commissioning etc. as required. 2For 6 way, Double door SPN MCBDB
od47504/2018_2019 : Supply and installation of the 40 A and 63 A, 10 kA, TP MCB (C curve) suitable for 50 Hz , AC supply conforming to IS 8828-1995/ IEC 60898 of the following current ratings in the existing enclosure and giving connections as required
2.13.1 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
5.4 : Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, andproviding masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
5.9 : Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earthelectrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
od47718/2018_2019 : Supply and providng 4 pole 25A AC1 rating power contactor on suitable size metal enclosure with illuminated flush head push button with LED with 24hr timer and giving connection as required for switching Street Lights
MOHSIN N BASHEER
Xavier Joseph
M Y ASSOCIATES
Bidder Name
M Y ASSOCIATES
HARISH AND CO
MOHSIN N BASHEER
Xavier Joseph
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .