Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.7 LAdmitted-Finance | ₹7.7 L | L1 | Admitted-Finance |
| 2 | L2₹7.8 LAdmitted-Finance MAALGODAM ROAD FURNITURE MARKET HALDWANI 263139 DISTT NAINITAL UTTARAKHAND | HALDWANI | NAINITAL | UTTARAKHAND | 263139 | ₹7.8 L | L2 | Admitted-Finance |
| 3 | L3₹8.2 LAdmitted-Finance BEHIND NIRMALA CONVENT SCHOOL CANAL ROAD KATHGODAM 263126 | NAINITAL | UTTARAKHAND | 263126 | ₹8.2 L | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | R C ENTERPRISES L3 | UTTARANCHAL ENGINEERS L2 | JOSHI ENTERPRISES L1 |
|---|---|---|---|---|---|---|
| 1.00 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.(in cement mortar) | 21 | CuM | 56,700 ₹66,906 | 49,350 ₹58,233 | 49,245 ₹58,109.10 |
| 2.00 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means in foundation trenches or pits of any size including dressing of sides and ramming of bottoms,, including getting out the excavated soil and disposal of surplus excavated soil as directed, including all leads and lifts. | 11 | CuM | 4,785 ₹5,646.30 | 4,763 ₹5,620.34 | 4,730 ₹5,581.40 |
| 3.00 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. | 3.24 | CuM | 7,776 ₹9,175.68 | 7,857 ₹9,271.26 | 7,840.8 ₹9,252.14 |
| 4.00 | Providing and laying in position cernent concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:4:8 (1 Cement , 4 coarse sand (zone-lll) derived from natural sources:B graded stone aggregate 40 mm nominal size derived from natural sources) | 2.2 | CuM | 16,500 ₹19,470 | 15,840 ₹18,691.20 | 15,840 ₹18,691.20 |
| 5.00 | Brick work wiith common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: cement motar 1:4 (1 cement : 4 coarse sand). | 10.9 | CuM | 97,010 ₹1.1 L | 93,031.5 ₹1.1 L | 92,650 ₹1.1 L |
| 6.00 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15" landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reintorcement with 1:1.5:3 (1 cement:1.5 coarse sand (zone-lll) derived from natural sources:3 oraded stone aggregate. | 5.1 | CuM | 56,100 ₹66,198 | 54,595.5 ₹64,422.69 | 54,570 ₹64,392.60 |
| 7.00 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all work complete above plinth level. ThermoMechanically Treated bars of grade Fe-500D or more. | 508 | Kgs | 60,960 ₹71,932.80 | 51,308 ₹60,543.44 | 50,800 ₹59,944 |
| 8.00 | 12mm thick plaster with cement mortar in proportion 1:4 cement and coarse sand 2.5 finest modulus over brick work min. thickness not to be less than 1 cm. lincluding supply of all materials ,labour and T&P etc. required for proper completion of work. | 165 | SqM | 47,850 ₹56,463 | 47,025 ₹55,489.50 | 46,200 ₹54,516 |
| 9.00Centering and shuttering including strutting,propping etc. and removal of foam. | ||||||
| 9.10 | Suspended roof floors, landing,balconies and access | 19.5 | SqM | 16,477.5 ₹19,443.45 | 16,380 ₹19,328.40 | 16,341 ₹19,282.38 |
Updated dates
Tender Value
₹7.8 L
EMD Value
₹25,000
Closing Date
4 Feb 2026, 5:00 pmClosed
SE(OandM)Haldwani
SE(OandM)Office Haldwani
Construction of Security guard room, parking shed and miscellaneous civil works at 132 KV Substation Kathgodam under 220KV OandM Division, PTCUL, Haldwani
2025_PTC13_90364_1
SE(OandM)/PTCUL/HLD/13/25-26
Open Tender
Civil Works
180 days
Haldwani
Please refer Tender documents.
3 documents required · 3 mandatory
₹590
Yes
EE 220KV OaM Division, PTCUL, Haldwani
₹25,000
Yes
SE(OandM)Office Haldwani
5 Mar 2026
26 Dec 2025
5 Feb 2026
26 Dec 2025
4 Feb 2026
26 Dec 2025
2 Jan 2026
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.(in cement mortar)
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means in foundation trenches or pits of any size including dressing of sides and ramming of bottoms,, including getting out the excavated soil and disposal of surplus excavated soil as directed, including all leads and lifts.
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
Providing and laying in position cernent concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:4:8 (1 Cement , 4 coarse sand (zone-lll) derived from natural sources:B graded stone aggregate 40 mm nominal size derived from natural sources)
Brick work wiith common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: cement motar 1:4 (1 cement : 4 coarse sand).
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15" landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reintorcement with 1:1.5:3 (1 cement:1.5 coarse sand (zone-lll) derived from natural sources:3 oraded stone aggregate.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all work complete above plinth level. ThermoMechanically Treated bars of grade Fe-500D or more.
12mm thick plaster with cement mortar in proportion 1:4 cement and coarse sand 2.5 finest modulus over brick work min. thickness not to be less than 1 cm. lincluding supply of all materials ,labour and T&P etc. required for proper completion of work.
Centering and shuttering including strutting,propping etc. and removal of foam.
Suspended roof floors, landing,balconies and access
Coulmns, pillars, Piers, Abutments
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to lS: 15622' of approve make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement 4 coarse sanq),jointing with grey cement slurry @ 3.3kg/ sqm including grouting the.joints with white cement and matching pigments etc., complete Size of Tile 600x600 mm.
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface, etc. complete.(On steel work)
Finishing with Deluxe surface paint system fo. interiors and exteriors using Primer as per manufacturers Specifications : Two or mofe coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Speclal primef applied @0.75 lk /10 sqm
Providing and applying white cement based putty of average thickness 1 mm, in approved brand and manufacturer. over the plastered wall surface to prepare the surface even and smooth complete.
Aluminium structural work for door and windows with extruded built up standard tubular sections/appropiate Z sections and other sections of approved make conforming to IS:733 and IS:1285 fixing with desh fastners of required dia and size including necessary filling up the gaps to the junctions i.e. at top bottom and side with required EPDM rubber/neoprene gasket etc. Aluminium section shell be polyster powder coated aluminium (minimum thickness of polyster powder coating 50 micron)smooth, rust, free, straight, mitered and jointed mechanically wherever required including cleat angle aluminioum snap beading for glazing/paneling, CP brass stainless steel screws etc. including cost of all consumables material, labours and T&P complete in all respect as per direction of engineer incharge.
Wiring for light point/power point/fan points/exhaust fan point/call bell point etc.with 1.5 sqmm FRLS PVC insulated copper conductor single core cable in surface/recessed medium the point with 1.5 sqmm FRLS PVC insulated copper conductor single core cable etc. required as per site conditions including cost of all consumables, material,labour and T&P complete in all respect as per the direction of engineer in charge.
Supply installation and commissioning of following electrical accessories including cost of all labour and T&P complete in all respect as per the direction of engineer in charge
5/6 A Switch
5/6 A Socket
12 Modular iron box complete with modular plate of best quality
Ceiling Rose/Holder
Installation, testing and commissioning of wall fan of reputed make, including cost of all consumables, material, labour and T&P complete inall respect as per the direction of engineer in charge.
Electrical Work Wiring for circuit/sub main wiring along with earthwire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.
(2x2.5 sq.mm + 1x2.5 sq.mm earth wire.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed.
Supplying and fixing following modular switch/socket existing modular plate & switch box including.
15/16 A switch
6 pin 15/16 A socket outlet.
Supply of pre-wired recess mounting 18W slim LED panel light, constant current integrated driver, Light Color 6000K lumen input voltage 220-240Volt,CRl >80, high efficiency, IEC complaint for safety and performance.Supply of pre-wired surface mounting LED Batten 2 Feet, 10 Watt, constant current integrated driver.
Supply of pre-wired surface mounting LED Batten 2 Feet, 10 Watt, constant current integrated driver,Light Color 6000K, input voltage 220- Nos. 240Volt,CRI >80, high efficiency, IEC complaint for, safety. performance.
Supply of 200 mm sweep exhaust fan, plastic frame, single phase, 220- 240 Volt, white colour, gravity shutter etc complete as required.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required, upto 450mm sweep.
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.49 MB
BOQ_107073.xls
BOQ • 0.30 MB
TD13.pdf
Tender Documents • 1.14 MB
PQR13.xls
Other Document • 0.16 MB
Download all tender documents and submit your bid