Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.0 LAccepted-AOC | L1 | Accepted-AOC Being L1 bidder | |
| 2 | L2₹24.8 L+₹1.4 L (5.84%)Rejected-Finance | L2 | Rejected-Finance Being not L1 bidder | |
| 3 | L3₹25.1 L+₹1.6 L (6.92%)Rejected-Finance NEAR NEELAMMA VEPACHETTU ASSAM GARDENS VISAKHAPATNAM 530 020 | VISAKHAPATANAM | ANDHRA PRADESH | 530020 | L3 | Rejected-Finance Being not L1 bidder | |
| 4 | L4₹25.4 L+₹2.0 L (8.43%)Rejected-Finance | L4 | Rejected-Finance Being not L1 bidder | |
| 5 | L5₹26.5 L+₹3.0 L (12.8%)Rejected-Finance D NO 4 96 40 27 FLAT NO 307 GREEN CASTLE APARTMENT GOPALAKRISHNA NAGAR SUJATHANAGAR VISAKHAPATNAM 530 051 | VISAKHAPATANAM | ANDHRA PRADESH | 530051 | L5 | Rejected-Finance Being not L1 bidder |
| Sl No | Description | Qty | Unit | MSN ENGINEERING WORKS L5 | Jessica Engineering Works L10 | ALPHA ENGINEERING CONSTRUCTIONS L6 | MONITOR ENGINEERING WORKS L8 | Bhuvaneswari Electrical Works L3 | SRI VINAYAKA INFRA L4 | PNR CONSTRUCTIONS L7 | SONI ENGINEERS CONTRACTORS L2 | NJ ENTERPRISES L9 | THE VENKATESWARA SUPPLIERS L1 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00NOTES / INSTRUCTIONS FOR STRICT COMPLIANCE :- (a) The contractor shall obtain sample approval for all materials incorporating in the work as per condition 10 of IAFW-2249 and Special Condition 11 of tender document mentioned here-in-after. (b) The Engineer-in-charge may direct the contractor in writing to procure and deposit up to 50% quantity of the material with in 30 days from the date of commencment as required at site out of quantity to complete the scope of work. Remaining 50% shall be procured as per site requirement during progress of work.The decision shall be final and binding on the contractor. (c) The contractor shall deposit the procured material to the store of concerned subdivision within 30 days from the receipt of written direction. Failing which contractor shall liable to pay a penal recovery of Rs. 5000/- per week, levied on the dues of contractor, subject to maximum up to 10% of the work done/CA Amount whichever is higher. (d)The contractor shall obtain approval of “Qualified Tradesman” as per condition 26 of IAFW-2249 before commencement of work at site and shall have sufficient manpower such as Electrician / FGM / Technician etc., readily available to meet the site requirement during emergency situation as per directions of Engineer-in-Charge. (e) The quoted rates shall be inclusive of cost of necessary Tools, Plants, Safety Equipments, Machinery etc., as per site requirement. | |||||||||||||
| 2.00 | Taking down existing un-serviceable cable from trenches, passing through pipes / ducts / or wells complete all as specified and directed.
Note:- Necessary earth work excavated will measured and paid separately. | 2,540 | RM | 31 ₹78,740 | 60 ₹1,52,400 | 20 ₹50,800 | 23 ₹58,420 | 10 ₹25,400 Lowest | 30 ₹76,200 | 80 ₹2,03,200 | 50 ₹1,27,000 | 20 ₹50,800 | 15 ₹38,100 |
| 3.00 | Supply & laying LT XLPE insulated, armoured heavy duty electric cable with alumimium conductor, 1100 volts grade, cross sectional area 300 Sqmm x 3.5 Core, laid in trenches / passing through pipe / duct / on wall complete all as specified and directed. | 100 | RM | 1,200 ₹1,20,000 | 2,280 ₹2,28,000 | 1,550 ₹1,55,000 | 1,253 ₹1,25,300 | 1,100 ₹1,10,000 | 1,000 ₹1,00,000 Lowest | 1,575 ₹1,57,500 | 1,700 ₹1,70,000 | 1,350 ₹1,35,000 | 1,070 ₹1,07,000 |
| 4.00 | All as per Sl item No. 3.00 here in before but cross sectional area 240 Sqmm x 3.5 Core | 180 | RM | 1,150 ₹2,07,000 | 1,850 ₹3,33,000 | 1,260 ₹2,26,800 | 1,123 ₹2,02,140 | 900 ₹1,62,000 | 900 ₹1,62,000 | 1,395 ₹2,51,100 | 1,400 ₹2,52,000 | 1,080 ₹1,94,400 | 875 ₹1,57,500 Lowest |
| 5.00 | All as per Sl item No. 3.00 here in before but cross sectional area 185 Sqmm x 3.5 Core | 220 | RM | 925 ₹2,03,500 | 1,470 ₹3,23,400 | 1,000 ₹2,20,000 | 1,023 ₹2,25,060 | 950 ₹2,09,000 | 700 ₹1,54,000 Lowest | 905 ₹1,99,100 | 1,100 ₹2,42,000 | 920 ₹2,02,400 | 700 ₹1,54,000 Lowest |
| 6.00 | All as per Sl item No. 3.00 here in before but cross sectional area 150 Sqmm x 3.5 Core | 140 | RM | 825 ₹1,15,500 | 1,175 ₹1,64,500 | 800 ₹1,12,000 | 993 ₹1,39,020 | 550 ₹77,000 Lowest | 600 ₹84,000 | 825 ₹1,15,500 | 872 ₹1,22,080 | 720 ₹1,00,800 | 570 ₹79,800 |
| 7.00 | All as per Sl item No. 3.00 here in before but cross sectional area 95 Sqmm x 3.5 Core | 450 | RM | 500 ₹2,25,000 | 770 ₹3,46,500 | 540 ₹2,43,000 | 733 ₹3,29,850 | 400 ₹1,80,000 | 450 ₹2,02,500 | 685 ₹3,08,250 | 580 ₹2,61,000 | 450 ₹2,02,500 | 395 ₹1,77,750 Lowest |
| 8.00 | All as per Sl item No. 3.00 here in before but cross sectional area 50 Sqmm x 3.5 Core | 350 | RM | 280 ₹98,000 | 470 ₹1,64,500 | 320 ₹1,12,000 | 313 ₹1,09,550 | 300 ₹1,05,000 | 250 ₹87,500 Lowest | 355 ₹1,24,250 | 350 ₹1,22,500 | 320 ₹1,12,000 | 250 ₹87,500 Lowest |
| 9.00 | All as per Sl item No. 3.00 here in before but cross sectional area 25 Sqmm x 4 Core | 500 | RM | 185 ₹92,500 | 300 ₹1,50,000 | 210 ₹1,05,000 | 213 ₹1,06,500 | 230 ₹1,15,000 | 150 ₹75,000 Lowest | 245 ₹1,22,500 | 210 ₹1,05,000 | 200 ₹1,00,000 | 175 ₹87,500 |
| 10.00 | All as per Sl item No. 3.00 here in before but cross sectional area 16 Sqmm x 4 Core | 450 | RM | 160 ₹72,000 | 250 ₹1,12,500 | 160 ₹72,000 | 163 ₹73,350 | 180 ₹81,000 | 120 ₹54,000 Lowest | 185 ₹83,250 | 170 ₹76,500 | 185 ₹83,250 | 145 ₹65,250 |
Tender Value
₹39.9 L
EMD Value
₹79,800
Closing Date
8 Dec 2025, 6:00 pmClosed
Garrison Engineer Utility-I Visakhapatnam
Garrison Engineer Utility-I Near Samudrika Naval Base Post Visakhapatnam -530 014
REPAIR/MAINT OF LT PANELS, DISTR FEEDER PILLAR BOXES, LT DISTR SYSTEM AND OTHER CONNECTED WKS AT CIRCAR, NOI, HQ ENC, MMT AND OTHER ALLIED AREAS UNDER AGE E/M NO-I OF GE(U-I) VISAKHAPATNAM
2025_MES_740211_1
8817/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Garrison Engineer Utility-I Visakhapatnam
As per NIT
7 documents required · 7 mandatory
₹500
Garrison Engineer Utility-I
₹79,800
Yes
27 Jan 2026
17 Nov 2025
10 Dec 2025
17 Nov 2025
8 Dec 2025
2 Dec 2025
Amount
NOTES / INSTRUCTIONS FOR STRICT COMPLIANCE :- (a) The contractor shall obtain sample approval for all materials incorporating in the work as per condition 10 of IAFW-2249 and Special Condition 11 of tender document mentioned here-in-after. (b) The Engineer-in-charge may direct the contractor in writing to procure and deposit up to 50% quantity of the material with in 30 days from the date of commencment as required at site out of quantity to complete the scope of work. Remaining 50% shall be procured as per site requirement during progress of work.The decision shall be final and binding on the contractor. (c) The contractor shall deposit the procured material to the store of concerned subdivision within 30 days from the receipt of written direction. Failing which contractor shall liable to pay a penal recovery of Rs. 5000/- per week, levied on the dues of contractor, subject to maximum up to 10% of the work done/CA Amount whichever is higher. (d)The contractor shall obtain approval of “Qualified Tradesman” as per condition 26 of IAFW-2249 before commencement of work at site and shall have sufficient manpower such as Electrician / FGM / Technician etc., readily available to meet the site requirement during emergency situation as per directions of Engineer-in-Charge. (e) The quoted rates shall be inclusive of cost of necessary Tools, Plants, Safety Equipments, Machinery etc., as per site requirement.
Taking down existing un-serviceable cable from trenches, passing through pipes / ducts / or wells complete all as specified and directed. Note:- Necessary earth work excavated will measured and paid separately.
Supply & laying LT XLPE insulated, armoured heavy duty electric cable with alumimium conductor, 1100 volts grade, cross sectional area 300 Sqmm x 3.5 Core, laid in trenches / passing through pipe / duct / on wall complete all as specified and directed.
All as per Sl item No. 3.00 here in before but cross sectional area 240 Sqmm x 3.5 Core
All as per Sl item No. 3.00 here in before but cross sectional area 185 Sqmm x 3.5 Core
All as per Sl item No. 3.00 here in before but cross sectional area 150 Sqmm x 3.5 Core
All as per Sl item No. 3.00 here in before but cross sectional area 95 Sqmm x 3.5 Core
All as per Sl item No. 3.00 here in before but cross sectional area 50 Sqmm x 3.5 Core
All as per Sl item No. 3.00 here in before but cross sectional area 25 Sqmm x 4 Core
All as per Sl item No. 3.00 here in before but cross sectional area 16 Sqmm x 4 Core
M&L for cutting the tarmac / hard standings in road and excavating trenches across the road in size not exceeding 0.45 m wide and 0.6 m depth for laying cable including refilling earth & making good top surface of the disturbed portion with 100mm thick PCC (1:3:6), type C2 (40mm graded stone aggregate) or bituminous mix as per existing & matching with the surroundings complete all as specified and directed. Note : Rate quoted shall deemed to inclusive of road cutting of any description, earth work excavation and making good on top with 100 thick PCC complete.
S&F MCB TPN 40 to 100 Amp, 10 kA, 415V 'C' curve complete all as specified and as directed.
S&F MCCB 4 pole 630 Amps, 415 V breaking capacity 50 kA, Ics = 100% Icu, thermal magnetic release type with adjustable overload setting (0.8-1.0 ln), lcu = 100% confirming to IEC - 947, IS-1347 adjustable short circuit setting (6-10 lr) including extended terminals, thimbles, nuts, bolts, washers etc., and including taking down existing un-serviceable MCCB complete all as specified and as directed.
All as per Sl Item No. 13.00 above but 400 Amps breaking capacity 36 KA
All as per Sl Item No. 13.00 above but 250 Amps breaking capacity 36 KA
All as per Sl Item No. 13.00 above but 200 Amps breaking capacity 25 KA
All as per Sl Item No. 13.00 above but 160 Amps breaking capacity 25 KA
All as per Sl Item No. 13.00 above but 100 Amps breaking capacity 25 KA
M&L straight through joint, heat shrinkable type complete with jointing materials and accessories, suitable for 1.1 KV, 3.5 core LT XLPE aluminium conductor cable of size 240 to 300 Sqmm complete all as specified and directed. Note:- The cost of earth work & excavation shall deemed to included in the unit rate quoted against this item.
All as per Sl Item No. 19.00 here in before but suitable for cable of size 150 to 185 Sqmm
All as per Sl Item No. 19.00 here in before but suitable for cable of size 90 to 120 Sqmm
All as per Sl Item No. 19.00 here in before but suitable for cable of size 25 to 70 Sqmm
Re-laying only old servicable (cable obtained from taking out old cable here-in-before after checking the fault) UG LT XLPE electric cable with alumimium conductor, 1100 volts grade of any size, laid in trenches / duct / on pole complete all as specified and directed. Note:- Serviceable cable ontained from taking down shall be used for re-laying.
M&L for removing electrical connections of 3 / 4 pole Air circuit breaker of capacity 400 to 1600 Amps, 415 V, 50 HZ of any make, strip opening of the ACB, inspecting the parts for serviceability / overhauling complete and carrying out following repairs / maintenance :- a) Cleaning insulation parts including bushings with CTC solution. b) Checking alignment and condition of movable and stationary contacts and adjust them all as per manufacturer's instructional manual. c) Checking the bolts, nuts, washers, cotter pins and all terminal connections are in place and tight, replacing worn-out parts. d) Checking arc chutes for damage and replacing damaged parts. e) Cleaning and lubricating the operating mechanism with light machine oil (SAE-20 or 30) for pins and bearings and with a non-hardening grease for wearing surfaces, adjusting breaker operating mechanism all as per manufacturer's instructional manual, replacing the same if there is excessive wear and tear. f) Checking / inspecting shunt trip coil for serviceability and replacing the same if required. g) Replacing worn or burned contacts, Checking control device free for operation. h) Checking after servicing the circuit breaker to verify the contacts move to the fully opened and fully closed positions, that there is an absence of friction and that the electrical operation is functional. Note : (i) The rate quoted deemed to be inclusive of T&P and minor spares like lubricants, nuts / bolts / washers / pins etc. (ii) Major spares like contacts, shunt trip coil, relays, CTs etc if replaced, shall be measured & paid separately.
S&F Under voltage / Tripping / closing contact coil / auxiliary contact block suitable for air circuit breakers of rating / capacity 400 to 1600 Amps all as specified and directed.
S&F arc chutes (for 415 V) suitable for air circuit breakers of rating / capacity 400 to 1600 Amps all as specified and directed.
S&F shunt release (110 / 220 V DC or 240 / 415 V AC) of make as per OEM & suitable for ACB of 400 to 1600 Amps capacity complete all as directed.
S&F arcing contacts (fixed / moving) suitable for ACB of 400 to 1600 Amps capacity including taking down existing un-serviceable arcing contacts complete all as specified and directed.
Comprehensive maint for Synchronizing panel of any Make as and when directed by Engr-in-Charge as per requirement by a qualified technician, comprising of the following outlined services:- Notes:- (i) The Contractors technical team shall visit the installation site for periodic preventive maintenance, check up of the synchronizing system. (ii) DC back up source will be maintained by checking / servicing. (iii) Apart from the periodic preventive maintenance visits, all break down calls for the systems covered under the contract shall be attended including Sunday and holidays. (iv) Cost of all minor spares (Nut bolts, control wires, lugs, minor soldering, multicolour resistors, capacitors varistors and circuit connectors etc.) to put the Synchornizing panel in working condition shall deemed to be included in unit rate qouted complete however major components like logic control board, drive boards and contractors if required shall deemed to be included in unit rate qouted. (v) Response time during normal working hours shall not be more than 4 Hrs from the time of receipt of complaint and the resolution time shall be maximum 48 hrs, based on the nature of complaint and replacement of components and boards. (vi) Transport / rent of the same shall be borne by the contractor during the contract period and unit rate qouted shall deemed to include this aspect complete all as directed by the Engr-in-Charge. (vii) The rate qouted deemed to be inclusive of any software updation required.
Comprehensive maint for PLC based LT panel of any Make as and when directed by Engr-in-Charge as per requirement by a qualified technician, comprising of the following outlined services:- Notes:- (i) The Contractors technical team shall visit the installation site for periodic preventive maintenance, check up of the PLC system. (ii) The rate qouted deemed to be inclusive of any software updation required. (iii) Apart from the periodic preventive maintenance visits, all break down calls for the systems covered under the contract shall be attended including Sunday and holidays. (iv) Cost of all minor spares (Nut bolts, control wires, lugs, minor soldering, multicolour resistors, capacitors varistors and circuit connectors etc.) to put the Synchornizing panel in working condition shall deemed to be included in unit rate qouted complete however major components like logic control board, drive boards and contractors if required shall deemed to be included in unit rate qouted. (v) Response time during normal working hours shall not be more than 4 Hrs from the time of receipt of complaint and the resolution time shall be maximum 48 hrs, based on the nature of complaint and replacement of components and boards. (vi) Transport / rent of the same shall be borne by the contractor during the contract period and unit rate qouted shall deemed to include this aspect complete all as directed by the Engr-in-Charge.
M&L for preparation of external surfaces of old existing LT panels indoor/outdoor type by scraping down old dusted paint by steel brush, brooming, rubbing and cleaning including spray painting with One coat of synthetic enamel paint and marking feeders complete all as specified and as directed by Engineer-in-Charge.
M&L for decarburizing / cleaning complete LT 415 Volts 3 phase panel / bus bar chamber with electrical connections, bus bar, cleaning with CTC and ensure proper decarburizing, re-fixing the same after applying becktol Red solution to the bus bar insulator & checking all the connections, tightening the nuts, bolts & thimbles of incoming / outgoing system complete including replacement of defective rusted bolts & nuts all as specified and directed.
M&L replacement of out door panel board canopy door, made out of 3.15 mm thick CRCA sheet, duly power coated with removable door hinges, water proof rubber beading and locking arrangement with SS aldrop & pad lock/ concealed locking arrangement, danger notice boards, mentioning panel details including gas welding for fixing the door complete all as directed. Note:-Unit rate quoted shall be considered to include locking arrangement with SS aldrop & pad lock/ concealed locking arrangement, danger notice boards, etc reqd for one LT panel. Contactor shall quote their rates accordingly.
M&L for detecting LT UG cable faults located in any stretch / depth with sophisticated cable fault locator consisting of microprocessor based pre-locator system, HV / LV surge generator, fault pin point surge wave receiver, cable identification instrument , cable tracer for exact location of under ground cable routes complete all as directed. Note:- The rate quoted deemed to be inclusive of arrangement of necessary fault locator equipment, transportation of equipment& charges for service engineer.
S&F on-load change over switch 250 Amp capacity, 4 pole, 415 volts, manual change over with Sheet metal enclosure including fixing in existing panel and necessary modification in the panel (if reqd) including taking down Un-serviceable on-load change over switch complete all as specified and directed.
All as per item No. 35.00 here in before but 400 Amps
S&F Digital Panel meter for Amp, Volt, KWH, power factor and other parameter Hz, pf, power, energy alongwith connected CTs.
S&F 3 core 2.5 sqmm flexible PVC stranded copper conductor cable, unsheathed, 1100 V grade for control wiring including taking down old unserviceable old cables complete all as directed by Engr-in-Charge.
M&L for disconnecting electrical connection of defective / burnt out UG LT cable of any size 2 to 4 core from LT Panels / main switch / DB / Junction boxe etc., excavating & taking out required length (3 to 5m) of existing cable from its loop, cleaning & cutting the defective portion of cable / old termination at end, providing new aluminium thimbles / lugs of suitable size and reconnecting the same with existing location and refilling of cable trench with existing sand and bricks complete all as directed. Note :- (i) The rate quoted shall include for necessary earth work and excavation. (ii) Serviceable sand and Bricks shall be re-used for protection.
S&F aluminium lugs to cable end suitable for cable of size of 25 Sqmm complete all as specified and directed.
All as per Sl item No. 40.00 here in before but suitable for cable of size of 50 Sqmm
All as per Sl item No. 40.00 here in before but suitable for cable of size of 70 Sqmm
All as per Sl item No. 40.00 here in before but suitable for cable of size of 95 Sqmm
All as per Sl item No. 40.00 here in before but suitable for cable of size of 150 Sqmm
All as per Sl item No. 40.00 here in before but suitable for cable of size of 185 Sqmm
All as per Sl item No. 40.00 here in before but suitable for cable of size of 240 Sqmm
All as per Sl item No. 40.00 here in before but suitable for cable of size of 300 Sqmm
M&L earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground in vertical position (earth pit not less than 2.25 m deep below the normal ground level) with top edge of the earth plate not less than 1.5 m below normal ground level, connected to earth lead of galvanised iron strip 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel, all as shown in electrical plate No. 3 connected to earthing test point including dismantling un-serviceable earthing complete all as specified and directed. Note:- The unit rate shall also include for earth work in any type of soil, PCC 1:3:6 type C1 chamber, RCC 1:1.5:3, type A1 cover slab, 50 mm thick reinforced with 8 mm dia TMT bar @ 140 mm C/C both ways, 10 mm dia plain bar lifting handle embedded in cover slab, Main earthing lead from earth electrode to test point upto 7.5 m length, 20 mm bore medium grade GI watering pipe, 40 mm bore GI medium grade earth lead protection pipe, funnel, wire mesh, copper lugs, charcoal and common salt in alternate layer etc.
S&F maintenance free battery of 12 V, 65 AH including terminal clamps, copper lead of suitable length including testing and commissioning including taking down existing unserviceable battery complete all as specified and directed by Engr-in-Charge.
Excavation in trenches, not exc 1.5 m wide and not exc 1.5 m in depth; laying of cable etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft / loose soil complete all as specified and directed.
Returning, filling in trenching with soil and including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and as directed.
Removing of excavated surplus soil to a distance n. exc 50 m and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed.
M&L sand cushioning with River sand in trenches for protection of UG cable and including punning down complete all as specified and directed. Note:- Punned thickness of sand coushioning shall only measured and paid.
Supply & laying sub class 'B', class designation 75 bricks of old size, laid over sand cushioning along alignment of cable as protection to cable in trenches including taking out old bricks complete all as specified and directed. Note : Sand cushioning will measured and paid seperately.
Re-laying of InterLocking Paver Blocks, 60 mm thick at the same or different location including Supply & laying a layer of 50 mm thick sand cushioning base of blocks including dismantling existing pavement complete all as specified and directed by Engr-in-Charge. Note:- (i) Rate qouted by the tenderer shall deemed to inclusive of 50mm thick sand cushioning and including packing with PCC of size 300x110 mm of PCC 1:2:4, type 'B' (20 mm graded stone aggregate) on both sides of pavement. (ii) Paver Blocks obtained from dismantling shall be used for re-laying.
S&F 100 mm bore dia galvanised steel tubing, light grade galvanised, laid under road crossing, for cable protection or fixed to poles, walls or laid under floors complete all as specified and directed.
All as per Sl item No. 56.00 here in before but 80 mm bore
All as per Sl item No. 56.00 here in before but 50 mm bore
S&F in repairs for cable route indicator for LT UG cable, 1100 Volt grade made out of 4mm thick MS sheet in round shape of dia not less than 200mm, embossed with LT Cable on it, bolted with 2 nut of suitable size at top of 40 x 6 mm MS flat iron of length not less than 1 meter, complete metal surfaces painted with 2 coats of synthetic enamel paint over a coat of primer & bottom of flat iron embedded in PCC (1:3:6), type C2 (40 mm graded stone aggregate) of size 200mm x 200mm x 500mm (400mm below ground level and 100mm above ground level), exposed surface of concrete painted with 3 coats of white wash including necessary earth work complete all as specified and directed. Note:- Rate qouted shall deemed to be inclusive of cable route indicator, earth work, excavation and concrete complete.
SONI ENGINEERS CONTRACTORS (BID ID -3492384)
Bhuvaneswari Electrical Works (BID ID -3492121)
SRI VINAYAKA INFRA (BID ID -3492055)
MSN ENGINEERING WORKS (BID ID -3491434)
ALPHA ENGINEERING CONSTRUCTIONS (BID ID -3492056)
PNR CONSTRUCTIONS (BID ID -3491419)
MONITOR ENGINEERING WORKS (BID ID -3492079)
NJ ENTERPRISES (BID ID -3492612)
Jessica Engineering Works (BID ID -3492031)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.45 MB
8817Tender.pdf
Tender Documents • 0.75 MB
BOQ_828839.xls
BOQ • 0.63 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .