Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.4 LAccepted-AOC 22 JANKALYAN SOCIETY NAVJIVAN AJWA ROAD BARODA 390 019 | BARODA | VADODARA | GUJARAT | 390019 | L1 | Accepted-AOC Being lowest tenderer | |
| 2 | L2₹27.9 L+₹96,393.85 (3.58%)Rejected-Finance | L2 | Rejected-Finance Not being lowest tenderer | |
| 3 | L3₹28.5 L+₹1.6 L (5.97%)Rejected-Finance NEAR RAZZAQ FARM DEVPUR DEVKA POST OFFICE KATHGANIA HALDWANI DISTRICT NAINITAL U K | L3 | Rejected-Finance Not being lowest tenderer | |
| 4 | L4₹28.9 L+₹2.0 L (7.24%)Rejected-Finance FEDRICK VILLA NEAR ELECTRIC POWER HOUSE RANIKHET 263 645 UK | ALMORA | UTTARAKHAND | 263645 | L4 | Rejected-Finance Not being lowest tenderer | |
| 5 | L5₹29.7 L+₹2.8 L (10.3%)Rejected-Finance | L5 | Rejected-Finance Not being lowest tenderer |
Tender Value
₹42.7 L
EMD Value
₹85,500
Closing Date
15 Nov 2023, 6:00 pmClosed
GE RANIKHET
GE (MES) RANIKHET
SPECIAL REPAIR TO BLDG NO P 99 1 2 3 4 AND P 101 1 2 3 4 OR MD ACCN OF 19 KUMAON AT GHINGHARIKHAL RANIKHET UNDER GE RANIKHET
2023_MES_623900_1
GE/RKT/55 OF 2023-24
Open Tender
Civil Works
Item Rate
180 days
Ghingharikhal Ranikhet under GE Ranikhet
As per NIT
6 documents required · 6 mandatory
₹500
Yes
GE RANIKHET
₹85,500
Yes
28 Feb 2024
18 Oct 2023
22 Nov 2023
18 Oct 2023
15 Nov 2023
1 Nov 2023
Amount
BOQ ( Sch 'A') B/R items Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M & L for screed bed or bedding layer 15mm thick in cement mortar(1:6) for laying floor finishes complete all as specified and directed.
M & L for non skid ceramic coloured /printed tiles 7 to 8 mm thick (square / Rectangular) area of each tiles exceeding 0.18 Sqm but not exceeding 0.36 sqm in floors etc set and jointed in neat cement slurry and pointed in coloured cement to match the tiles complete all as specified and directed.
M & L for non skid ceramic coloured /printed tiles 7 to 8 mm thick (square / Rectangular) area of each tiles exceeding 0.11 Sqm but not exceeding 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in coloured cement to match the tiles complete all as specified and directed.
M & L for ceramic coloured /printed tiles 7 to 8 mm thick (square / Rectangular) area of each tiles exceeding 0.18 Sqm but not exceeding 0.36 sqm in skirting/dado/on verticle surfaces, etc set and jointed in neat cement slurry and pointed in coloured cement to match the tiles complete all as specified and directed.
M&L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 for backing/screed bed of dado/ skirting & Vertical Tiles complete all as specified and directed.
M & L for glazed ceramic coloured / printed tiles 300mm x 450mm, 6 to 7mm thick, on vertical surfaces set and jointed in neat cement slurry and pointed in white/coloured cement to match the tiles, complete all as specified and as directed.
M & L for Black Granite (of any type) tiles 20 mm thick machine cut , bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishig, in cooking platforms and like complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) complete all as specified and directed.
M & L for 75 mm thick PCC (1:3:6) type C2 using 40mm graded stone aggregate as in plinth protection finishing the surface even and smooth without using extra cement, laid in bays including necessary form work complete all as specified and directed.
Taking down cement or cement lime plaster of any description on brick or PCC block masnory or stone walls, etc including racking out joints, hacking for key, scrubbing down with water etc & removing rubbish to a disance not exc 250m complete all as specified and directed.
M&L for rendering 15 mm thick on other than fair faces of brick work or stone masonry or concrete surfaces in cement mortar 1:4 and finished even and smooth without using extra cement includig mixing of water proofing compound of approved make @3% by weight of cement complete all as specified and directed. Note: Water proofing compound shall be measured and paid separately.
M & L for 15mm thick rendering in cement mortar 1:6 on stone masnory surfaces or other than fair faces of brick work, surface finished even & smooth with a dubbing out average 10mm thick on irregular face of walls, complete all as specified and directed.
M/L for preparing newly plastered wall surfaces and applying two coat of distemper oil emulsion over a coat of primer(Priming the plastered and other surface preparatory to distempering) complete all as specified and directed.
M&L for preparation of newly plastered surface of external wall all as prescribed by manufacture of paint and applying two coats of exterior anti fungal acrylic emulsion paint (walmista of Berger paint or equivalent in Asian paint, Nerolac etc having three years of performance warranty) over a coat of exterior water based primer of same make all as specified and prescribed by manufacture of paint complete all as specified and as directed. Note:- (i) The newly plastered surface must be prepared in a manner so that there should not be any impression of dent and it should be made even all as per manufacture instruction before application of emulsion paint. The cost of all materials, T&P and labour required for preparation of surface shall deemed to be included in the rate quoted by the contractor. (ii). The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor. The authorised applicator of manufacturer shall be got approved from GE before commencement of work. (iii). All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by department for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacturer. (iv). After carrying out preparation of surface the same shall be got approved from GE before application of distemper for each building. (v). The colour / shade will be all as approved by GE. (vi) The cost of Scaffolding wherever required shall deemed to be included in the rate Quted by the Contractor.
M & L for complete removal of existing treatment for preparing old painted surfacess and applying two coats of distemper oil emulsion over a coat of primer complete all as specified and directed.
M&L for preparation of old decorated surface of internal wall by removing existing treatment with mechanical sander (rpm 1500-2700) along with internal dust extraction system for clean environment certified by reputed paint manufacturers and applying two coats of acrylic distemper over a layer of wall care putty to make the surface smooth using roller all as specified and prescribed by manufacturer of paint complete all as specified and as directed. Note:- (i) The old surface must be prepared in a manner so that there should not be any impression of dent and it should be made even and smooth all as per manufacturer's instruction before application of distemper. The cost of materials, labour & T&P required for preparation of surface shall deemed to be included in the rate quoted by the contractor. (ii) The work must be got executed through authorised applicator of manufacturer after concluding an MoU with manufacture for company back guarantee by the contractor. The authorised applicator of manufacturer shall be got approved from GE before commencement of work. (iii) All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by department for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacturer. (iv) After carrying out preparation of surface the same shall be got approved from GE before application of distemper for each building.
Demolition brick work or stone/ boulder or PCC block masonery built in cement mortar including all quoins , pillars etc complete all as specified and directed
M&L for brick work using sub class ‘B’ old size bricks, straight or curved on plan exceeding 6m mean radius, built in CM (1:6) complete all as specified and directed.
M&L for brick work using sub class ‘B’ old size bricks, straight or curved on plan to any radius in half brick thick walls, built in CM (1:4) complete all as specified and directed.
M & L for 10mm thick rendering on fair faces of brick work or concrete surfaces in cement mortar 1:4, finished even & fair complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frame) not exc 1.5 sqm each & removing from site complete all as specifed & directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frame) exc 1.5 sqm but not exc 4 sqm each & removing from site complete all as specifed & directed.
Taking down shutters ( per leaf ) of any description not exceeding 1 Sqm each complete all as specified and directed.
M&L for second class hard wood plain, solid, straight chowkats and frames, wrought, frame rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed.
S&F factory Made Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded includinf gauged Shutter and fly Proof Shutter with wire mesh 0.5mm dia complete all as specided and directed
S&F factory made 35mm thick Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specided and directed
S & F 35 mm thick Second class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass etc sizes of members of shutters as specified in SSR Part-I, section 8, clause 8.24 (a), supplied and fitted to chowkats complete all as specified and directed.
S & F 100 mm long Mild steel barrel tower bolts, stove enamelled black, with bright bolt and fixed complete all as specided and directed
S & F 100 mm long Aluminium, anodised, barrel tower bolts of extruded section complete all as specided and directed
S & F floor door stopper of chromium plated body with rubber shoe fixed in door, overall length of cover plate 140 mm complete all as specided and directed
S & F butt hinges, medium weight, Mild steel and fixed, size of hinges 75mm complete all as specified and directed.
S & F butt hinges, medium weight, Miled steel and fixed, size of hinges 100mm complete all as specified and directed.
S & F 150 mm long Extruded Aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
S & F 100 mm long Extruded Aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
S & F 300 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast Aluminium alloy complete all as specified and directed.
S&F Block boards , 25 mm thick, grade 1 quality, exterior grade, decorative face on both faces Veneering ditto , , fixed with screw to timber frame work in cup board shutters/shelves incl teak wood beading complete all as specified and directed.
S&F Continuous (piano) hinges width 30 mm mild steel, bright finish or eletrogalvanised complete all as specified and directed.
M &L for Pre laminated exterior grade both side laminated board , 19/20 mm thick, grade 1 quality, exterior grade,Commercial type, fixed with screw to timber frame work in cup board shutters/shelves complete all as specified and directed.
M & L for preparation of old painted steel and iron surfaces of any description, over 10 cm in width or girth, not otherwise described and applying one coat of synthetic enamel complete all as specified and directed.
M & L for preparation of new steel and iron surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
M & L for mild steel rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates fe 290 gde E -165 complete all as specified and directed.
S & F in repair Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with Stainless steel wire staples complete all as specified and directed.
Hacking out old broken glass ( any thickness ) size or description from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and directed.
S & F in repair sheet glass, 3mm thick figured , pin headed and glazing with beadings in square not exceeding 0.5 Sqm in each pane complete all as specified and directed.
S & F 3 mm thick Sheet glass, ordinary quality and glazing with oil putty in squares not exceeding 0.5 Sqm in each pane complete all as specified and directed.
S&F Factory made single extruded WPC (wood polymer Composite) solid door/ window/ Ceosetory window & other Frames/ Chowkhat of size 45 x 70 mm comprising of PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms ) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded stat headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N / mm 2 and resistance to spread of flame of Class A catogory with property of being termite/ borer proof, water / moisture proof and fire retardant and fixed in position with MS hold fast/lugs / SS dash fasteners of required dia and length complete as per direction (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately).
S&F Factory made single extruded WPC (wood polymer Composite) solid plain flush door shutter of 35 mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/ cum and screw withdrwal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N mm2 modulus of elasticity 850 N / mm2 and resistance to spread of flame of Class A catogary with property of being termite/ borer proof, water/ moisture proof and fire retardanat and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk SS screws, all as per direction (Note:- stainless steel butt hinges and necessary SS screws shall be paid separately.
M & L for preparation of new wood and wood based surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M&L for preparation of old painted wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat of Synthetic enamel paint (Ordinary tint) complete all as specified and directed.
Taking up or down 15 mm bore steel tubing and connections, including cleaning for refixing or removal from site complete all as specified and directed
Taking up or down 20mm bore steel tubing and connections, including cleaning for refixing or removal from site complete all as specified and directed
Cutting chases, for water tubing or concealed , etc, and making good to facings where required and plastering in cement mortar (1:4) cutting not exceeding 10cm girth in brick walls complete all as specified and directed.
S&F GI water tubing of 15mm dia ,medium grade conforming to IS-1239(Part -1) including all GI fittings such as bends,tees,short pieces,connectors,elbows,reducers,union dockets etc & fixed to walls,ceilings, & laid on floors complete all as specified and directed.
Refixing of old 15 mm bore steel tubing and connections in new or old position (walls, ceiling, floors etc.) complete all as specified and directed
S&F GI water tubing of 20 mm dia ,medium grade conforming to IS-1239(Part -1) including all GI fittings such as bends,tees,short pieces,connectors,elbows,reducers,union dockets etc & fixed to walls,ceilings, & laid on floors complete all as specified and directed.
S&F in repairs stop valves, cast copper alloy, fency type chromium plated , screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed for 15mm bore dia of pipe complete all as specified and directed.
S&F in repairs stop valves, cast copper alloy, fency type chromium plated with long shank & cup (concealed) , screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed for 15mm bore dia of pipe complete all as specified and directed..
S & F vitreous china wash basin, white, flat back, size 620X480X185 mm, (flat back or angle back type) including brackets and including cutting for and pinning in ends of brackets or erecting stand, fixed in repairs complete all as specified and directed. Make i ( Jaquar cat Part No:- FNS-WHT-40801 ii ( Cera cat Part No :- 1067 A or equivalent in make Kajaria Bathware Pvt Ltd .
S & F in repairs 15 mm bore Fancy type pillar taps, Cast Copper alloy, with capstan heads, chromium plated, screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts, screwed for iron pipe and fixed complete all as specified and directed. Make i ( Jaquar cat Part No:- COP -001BPM ii ( Marc cat Part No :- MFX- 2010 or equivalent in make Cera Sanitaryware Ltd/Kajaria Bathware Pvt Ltd
S & F in repairs 15 mm bore Fancy type chromium plated Wall Mixer with provision for overhead shower with 115mm long bend pipe on upper side, connecting legs and wall flanges, screwed down high pressure with or without lettered hot and cold screwed for iron pipe complete all as specified and directed. Make i ( Jaquar cat Part No:- FUS- 29281 ii ( Marc cat Part No :- MDM - 2350 or equivalent in make Cera Sanitaryware Ltd/Kajaria Bathware Pvt Ltd .
S&F 32mm dia waste fittings, brass, chromium plated for glazed ware sinks, basins, etc with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed complete all as specified and directed.
S & F in repairs bib taps, cast copper alloy, 15 mm dia, Chromium Plated, fancy type with crutch or butterfly handle, screwed down for iron pipe and fixed etc complete all as specified and directed. Make i ( Jaquar cat Part No:- KUP- 35037 PM ii ( Marc cat Part No :- MFX - 2170 or equivalent in make Cera Sanitaryware Ltd/Kajaria Bathware Pvt Ltd .
S&F in repairs health faucet mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed. Make i ( Jaquar cat Part No:- ALD - 577 ii ( Marc cat Part No :- MAC - 3050 or equivalent in make Cera Sanitaryware Ltd/Kajaria Bathware Pvt Ltd .
S&F in repairs vitreous china squatting pan, 'Orissa' pattern, size 580mm x 440mm, white, with integral foot rests with 'P; or 'S' trap, including connection to trap, and to flushing pipe, anti-syphonage pipe, etc. in reapairs including Provn of lime concrete bedding and making good to floor complete all as specified and directed. Make ( Cera cat Part No:- 2071 or equivalent in make Jaqura/ Kajaria Bathware Pvt Ltd .
S&F in repair Traps 100 mm P or S with long arm complete all as specified and directed.
M&L for sunken floor treatment as described as under (i) to (vii) :- (i) Demolition of cement concrete of any description and in any position not otherwise specifically provided or in any type of filling in sunken portion & cleaning the sunken portion incl vertical wall surface complete as directed. (ii) M&L for filling the sunken floor with PCC ( 1:5:10) type E-2 using brick aggregate over the treated surface complete all as specified and directed. (iiii) M& L for 40mm thick (Min) PCC (1:2:4) type B-0 using 12.5 mm graded stone aggregate mixed with integral water proofing compound as per manufacturer instructions on bottom of sunken portion with proper slope towards spout (water proofing compound shall be measured and paid separately). (iv) Vertical sides shall be plastered in CM (1:3) 15 mm thick mixed with water proofing compound as per manufacturer instructions (water proofing compound shall be measured and paid separately). Plaster shall be extended over PCC coving when the same is green i.e. PCC & plaster be carried out at the same time complete all as specified and directed. (v) After laying sewage/ plumbing pipes with fixtures in position 2 coats of OMIPLAS EP-101 epoxy compound shall be applied complete all as specified and directed. (vi) Spouts of 25mm dia GI pipe light grade projecting 450mm clear of face outer a wall with mosquito proof cap on inner face of pipe shall be provided to drain out seepage water ,including cutting holes and making good if needed as specified and directed. (vii) Test again of water tightness by pounding for 72 hours & rectify defects if any till total elimination of defects complete all as specified and directed.The sunken portion shall be tested for leakage / seepage / dampness by pounding with water for 72 hours. In case any defect is noticed the portion shall be grouted with cement slurry mixed with suitable chemical & tested again. The process of grouting and testing shall be repeated till leakage / seepage / dampness is eliminated.
S & F in repairs 10 Liters capacity, PVC Valve less, Syphonic action type, low level flushing cistern, white, with inlet ball valve, float, handle, flush pipe of polyethylene of low or high density of PVC, 32mm dia including brackets and connections to pipe complete all as specified and as directed. Make i ( Cera cat Part No:- CIRIL-2617or equivalent in make Parryware/Kajaria Bathware Pvt Ltd .
S&F in repairs 600mmx450mm bevelled edge looking mirror and fixed to wooden plug with CP brass screws and cup washers complete all as apecified & directed
M & L for 32mm bore high density polyethylene pipes (HDPE), 600-750mm long complete all as specified and directed.
M&L for 75mm dia Cast iron floor trap with grating including jointing to waste pipe fixed in cement concrete (1:2:4) type B1 complete all as specified and directed.
S & F in repair 100 mm bore Cast iron soil, waste & vent pipe (spun pipes) in any length with or without ears , with cement joints fixed to walls or floor complete all as specified and directed.
S & F 100mm dia cost iron cowls complete all as specified and directed.
S & F in repair 75 mm bore Cast iron soil, waste & vent pipe (spun pipes) in any length with or without ears , with cement joints fixed to walls or floor complete all as specified and directed.
S&F in repairs brass chromium plated tubular towel rail, 20 mm dia, D; type, 60 cm long between flanges complete all as specified and directed. Make i ( Jaquar cat Part No:- ACN 11815 or equivalent in make Marc/Cera
S&F in repairs chromium plated Soap disk fixed to plug with chormium plated brass screws all as specified and directed. Make i ( Jaquar cat Part No:- ACN-1131N or equivalent in make Marc/Cera
S&F in repairs Chromium plated shower rose 125 mm swivel type Make i ( Jaquar cat Part No:- OHS-35495 ii ( Marc cat Part No :- MSR - 1170N or equivalent in make Cera
S & F in repairs 20mm Dia Aluminium alloy anodised curtain rod decorative fency type with brackets complete all as specified and directed
S & F in repairs PVC connections 15mm dia , 450mm long, , with PTMT nuts & washers at both ends complete all as specified and directed
Dismatling PVC Water tank Exc 250 & n exc 500 ltr and removing from site complete all as specified and directed
S & F Rotational moulded PVC water storage tanks 500 Ltrs capcity three layer (cylindrical vertical with closed top) hoissted and fixed in position complete all as specified and directed
S and F Ball brass valve 20 mm dia high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule complete all as specified and directed.
Dismantaling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strenth of 550 Mpa as in roof covering / clading to wall , fixed with self tapping screws complete all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of an colour having tensile strenth of 550 Mpa as in roof covering / clading to wall , fixed with self tapping screws complete all as specified and directed.
Dismantling of wall and ceiling boards (fiber, pulp, insulation etc,) or insulation boards/slabs/blankets, any thickness including cover fillet complete all as specified and directed.
S & F Aluminium anodised snap grid frame work for false ceiling comprising of following section for making partitions of 605 X 605 mm size fixed to walls with rawl plugs and screws and hang to roof with 4 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I.flat 40 x 3 mm size 60mm long and expansion hold fasteners12.5mm dia. 40mm long complete all as specified and directed, size of main tee shall be as under :- (i) 36.5mmx25mmx1.4mm thick, Weighing 0.24Kg/RM (ii) Cross Tee 23.5mmx36.4mmx1.4mm thick Weighing 0.191 Kg/RM and (iii) Wall angle 40mmx25mmx2mm thick. Weighing 0.36 Kg/RM
S & F 4 mm thick non asbestos fiber disigner ceiling (E-board classic) board / tiles for insulation and accoustic purpose, 600 X 600 mm size fixed with staples on snap grid as in ceiling with and including dusting of surface and applying two coats of oil bond distemper over a coat of primer complete all as specified and directed
M&L for 25 mm thick Cement concrete type-B-1, 1:2:4 (using 20 MM graded stone aggregate) laid in any situation/location complete all as specified and directed
Surface Excavation in hard/dense soil not exceeding 30cm deep and averaging 15cm deep and getting out complete all as specified and directed.
M & L for hard core of gauge not exc. 63mm, deposited, spread and leveled in layers not exc. 15 cm thick, watered and rammed to a true surface using broken stone or boulders complete all as specified and directed.
M&L for 75 mm thick cement concrete 1:4:8 type D-2 (using 40 MM graded stone aggregate) as in sub base, finished fair and even complete all as specified and directed.
M&L for chequred cement concrete tiles of size 300x300x25 mm thick coloured rubber pressed glossy finish, set and jointed in neat cement slurry and pointed in white or colour cement and match the surace of tiles as foor/staps, complete as all specified and directed.
Removing Excavated soil to a distance exceeding 250m but not exceeding 500m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
M & L for 15mm thick rendering in cement mortar 1:6 on fair faces of brick work or concrete surfaces finished even & smooth without using extra cement complete all as specified and directed.
M & L for providing plain cement concrete type B-1, 1:2:4 (using 20 mm graded crushed stone aggregate) as in coping, bed block for embedding hold fasts, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work as required complete all as specified and directed.
Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, laying of under ground cable etc., and getting out in Hard/ Dense soil complete all as specified and directed.
Demolition and breaking up drain pipes 150 mm (salts glazed ware, AC or Reinforced concrete) set in cement mortar complete all as specified and directed.
M & L for 150 mm dia Salt Glazed stone ware drain pipes, grade 'A' laid in trenches and jointed as specified complete all as specified and directed.
M & L for PCC 1:3:6 type C2 (using 40 mm graded stone aggregate) in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for pipes of 150mm bore complete all as specified and directed.
Returning, fillingin, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in hard/dense soil complete all as specified and directed.
M&L for cement concrete 1:3:6 type C-2 (using 40 mm graded stone aggregate) as in surface channel/ drain complete all as specified and directed.
M&L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mi- tred/stopped ends etc complete all as specified and directed.
BOQ ( Sch 'A') E/M items Taking down carefully Aluminium/copper wiring of any size (for light, fan, socket or power etc complete) ( fittings such as switches, sockets, ceiling roses, pendent holders regulators, tube lights etc to be measured and paid separately) and making good disturbed surfaces of wall, roof etc to match with existing surface complete all as specified and directed.
S & F point wiring for one light point / fan point / bell point / 5 Ampere socket outlet point (independent point), controlled by one, one way switch with 1.50 sqmm size PVC insulated unsheathed 1100 volts grade single core (multi-stranded) copper conductor cable (FRLS) drawn into and including medium grade PVC conduit concealed (not less than 20 mm dia) all necessary fittings and accessories fixed concealed (including chase cutting in brick/stone masonery/ pre cast PCC block masnory wall for fixing conduit and plastering the external surfaces and matching the same with existing suface) and sunk cast iron or pressed steel terminal boxes for mounting fitting like switches, sockets, lamp holders, sketch fittings and covered with 3 mm thick plastic laminated bakelite sheet cover fixed with brass screws and cup washers including one continuous run of PVC insulated (green colour) 1.50 sqmm size (FRLS) multi stranded copper conductor cable as in earth wire and connected to common earth dolly complete all as specified and directed, are as follows :- (a) One light/one fan/one bell point controlled by one, one way switch.
All as per item No 106 above but one light point controlled by two Nos of two way switch.
All as per item No 106 above but one socket outlet 5 pin 5 Amp controlled by one, one way switch on same board.
All as per item No 106 above but one socket outlet 5 pin 5 Amp controlled by one, one way switch on independent board.
All as per item No 106 above but wiring with using cable 2.50 sqmm size multi stranded copper wire (FRLS) and earth wire of PVC insulated (Green colour) 2.50 Sqmm size multi stranded copper wire (FRLS) for one 6 pin socket outlet, 16 Amperes on independent board.
S&F switch piano flush type single pole, one way 5 Amp complete all as specified and directed.
S&F switch piano flush type single pole, Two way 6 Amp complete all as specified and directed.
S&F socket out let multi 5 pin, 5 Amps, flush type complete all as specified and directed.
S&F switch piano flush type single pole, one way 15 Amp complete all as specified and directed.
S&F socket out let 2 in1,3 pin, 5 and 15 Amp, flush type complete all as specified and directed.
S&F ceiling rose, PVC/ Poly carbonate,isolated body three terminal complete all as specified and directed.
S & F lamp holder angle type PVC/Poly carbonate type insulated body with back plate suitable for batten/wall fitting complete all as specified and directed.
Supply and fixing LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder includingLED tube light connecting up with two core flexible copper conductor cable of suitable size from ceiling rose complete all as specified & directed.
Taking down unservicable MCB and S&F MCB SP, 240 volts,AC C curve, 10 KA 6 to 32 Amps complete all as specified & directed.
Taking down unservicable MCB and S&F MCB SPN , 240 volts,AC B curve, 10 KA 40 Amps complete all as specified & directed.
Taking down unservicable MCB and S&F MCB DP , 240 volts,AC C curve, 10 KA 40 Amps complete all as specified & directed.
Taking down unserviceable MCB S & F MCB TPN , 415 volts, AC C curve, 10 KA 100 Amps complete all as specified & directed.
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection complete. all as specified and directed .
Taking down unservicable DB and S&F sheet metal enclusure for DBs(double door type) single pole and neutral 8 way including blanking platge as required with 200 Amps rated bus bar, 240 volts fixed complete all as specified and directed .
S&F sheet metal enclusure for DBs(double door type) Triple pole and neutral 4way including blacking platge as required with 200 Amps rated bus bar, 415 volts fixed complete all as specified and directed .
S & F LED bulk head fitting, 1 x 10 watt with PDC aluminium housing and milky diffuser including LED light driver holder, complete with all accessories and including connecting up with three core twisted flexible copper conductor cable with suitable size of 230 Volts, 50 Hz complete all as specified and directed.
Taking out old unserviceable Sub main wiring for replacement including S&F sub main wiring with two single core FRLS PVC insulated and sheathed 1100 Volts grade, 6 Sqmm size cables, PVC insulated stranded copper conductor fixed in PVC conduite pipe 25mm dia with all accessories and one continuous run of 6.0 Sqmm stranded copper conductor PVC insulated and sheated complete all as specified and directed (Note :- Two single core cables along with earth wire and conduit shall be measured as one unit length).
M&L for earthing complete with galvanised steel, earth plate electode 600x600x6mm thick buried directly in gournd ( earth pit not less than 2.25mtrs below ground level ) with the top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanised earth lead wire 4mm dia by means of bolts, nuts check nuts and washers of galvanised iron/steel all as shown in electrical plate No 3 on page 497 of MES schedule 2009 Part I connected to main switch board/main DBs/earthing test point including all necessary excavation and earth work in hard/dense soil common salt and charcoal dust mixed and packed 150mm thick all-round the GI earth plate, watering pipe 20 mm dia GI medium grade, GI sheet 0.63 mm thick funnel, wire, gauge, 50mm thick RCC cover in PCC 1:2:4 type B1 duly reinforced with MS round suitable lifting handle to cover, GI protection pipe 15mm dia 'light grade' upto 7.5 Mtr from electrode etc, complete all as specified and directed including testing on completion. NOTE:- i) Earth lead beyond 7.5 m from electrode to earth terminal point/main switch board & GI pipe light grade 15 mm dia for protection against mechanical damage to lead shall be measured separately. (ii) On testing after completion if desired earth resistance is not obtained, the earthing will be redone by the contractor at no extra cost.
S & F call bell ding dong AC, 230V single pole fixed over with and including sunk spressed steel box of size 175mmx100mm with 3mm thick plastic laminated backalite shut cover fixed with brass screw complete all as specified and directed,
S&F bell push piano flush type single pole, one way 5 Amp complete all as specified and directed.
S& F LED Bulb of 9 watt alongwith 5 year warranty complete all as specified and directed.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with two core flexible copper conductor cable of suitable size complete all as specified and directed
Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc. complete all as specified and directed.
S&F sheet metal enclosure single pole and neutral with a two pin and earth plug and socket complete with one single pole MCB 240 Volts 20 Amps complete all as specified and directed.
S & F Exhaust fan plastic body heavy duty ISI mark, 250 mm size with louvers including all connecting accessories and cutting opening on wall and making good as per existing surface complete all as specified and directed
S&F Exhaust fan metallic body ISI mark, 300 mm size with louvers including cutting openings, through brick/ stone wall , making of holes and grouting of suitable size of nuts and bolts for 300 mm exhaust fan and making good dismantled portion and making connection with wire of suitable size and connecting accesssories complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core complete all as specified and directed.
Removing Excavated soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
M&L for sand cushioning in trenches spreading and consolidation 8cm thick before laying the cable & 15 cm of sand after laying the cable complete all as specified and directed. Note: Punnned thickness shall be measured and paid seperately
M&L for laying of bricks well burnt sub class ‘B’ (old size) laid flat for cable protection width equal to the lengrth of brick complete all as specified and directed.
M & L for galvanised steel water tubing 'light grade' 40 mm bore with all GI fittings laid under the roads, drains, culverts and fixed on poles etc complete all as specified and directed .
M/S S R Construction
M/s RK JOSHI&SONS
DEEPAK KUMAR BINWAL
M/s RN Kharwar & Sons
SS Construction Co
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .