Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.0 CrAccepted-AOC | ₹3.0 Cr | L1 | Accepted-AOC Awarded |
| 2 | L2₹3.8 Cr+₹78.9 L (26.4%)Rejected-Finance | ₹3.8 Cr+₹78.9 L (26.4%) | L2 | Rejected-Finance Rejected |
| 3 | L3₹3.9 Cr+₹86.2 L (28.8%)Rejected-Finance | ₹3.9 Cr+₹86.2 L (28.8%) | L3 | Rejected-Finance Rejected |
Tender Value
₹2.9 Cr
EMD Value
₹3.3 L
Closing Date
16 Aug 2022, 9:00 amClosed
Executive Engineer Jal Shakti Division Shillai
Executive Engineer Jal Shakti Division Shillai
SH CO RCC Intake CO Slow Sand Filter CO Sedimentation Tank CO Raw water tank CO Pump House CO Storage Tank at various Node PLJ of Rising Main for Stage 1st and 2nd SE Pumping Machinery for Stage 1 and 2nd LJ of GI pipes for D System and balance FH
2022_HPIPH_63474_1
SHL-SMR03-780-JSV DIV-SHILLAI-3469-3520DT 06.08.22
Open Tender
Pumps/Motors
Item Rate
365 days
Shillai
Please refer Tender documents.
13 documents required · 13 mandatory
₹2,500
Executive Engineer Jal Shakti Division Shillai
₹3.3 L
13 Feb 2023
6 Aug 2022
16 Aug 2022
6 Aug 2022
16 Aug 2022
6 Aug 2022
Amount
Pumping Machinery 1st Stage
Supply, erection, testing & commissioning of Cenrtifugal pumping set of reputed make such as KSB/BS/ Johnston/ Worthington/Suitable alloyas per BIS 5659 or latest up to date ammendments suitable for raw/clear water having greased packed bearings and shell with wound starter on motor side and with shaft protecion sleeve on pump side ensuring better life for shaft confirming BIS specifications. The pump shall be directly cuppled to a submesible squirrel cage electric induction motor of Kirlosker/ NGEF/ Jyoti/ Crompton conforming to relevent BIS Code with upto date ammendments totaly dust and water proof for submersible duly isolated from the pump by intermediate casing with double machenical seal in oil chamber and grese packed lubricated bearings and provided with stainless steel thrust bearing plate to with stand no vertical loads with minimum wear and tear. It should also be fitted with a device take up expansion of water with the heating of motor. The pump set should include water level guard, erection clamps, cable clip and depth gauge etc and suitable for operation on data given below:-
Total Head 591.52 mtrs
Capacity of each pump set 4.71 LPS
Dia of R/Main 80 mm
Dia of column pipe (mm) 65 mm
Supply of suitable direct on line/oil immersed star delta /ATS/stator rotor starter of standard make such as MEI/Kilburn/Jyoti/ Siemens/Larson & Tubro conforming to BIS-8544-1979 latest with up to date ammendments for squirrel cage/slip-ring motor (make to be specified by the tenderers) mounted on panel board with magnetic type over load release & dashpot,time lag,under voltage release with initial oil filling .
Note:- Star - delta - starter upto 37.5 KW , ATS between 37.5 KW to 50 KW
Providing &fixing at site M.S. sheet 16 SWG steel fabricated floor mounted closed almirah type switch board including angle iron post of suitable height and size ISA 40x40x6mm duly painted comprising and capable of mounting the following accessories with all internal electric connections. The drawing of panel board shall be subject to approval of Engineer in charge.
ICTP switches with HRC fuses of Kilburn/Larsen & Tubro/Standard/Siemen/Havells make and having capacity 30% extra of the operational rating of motor as per BIS 4064-1978 with upto date ammendments immediatly after the power meter of HPSEB.
Busbar chamber having three copper bars of suitable rating for full length equal to width of board of three live phases and one copper bar of half rating of full length for neutral conforming to BIS 8084-1976 and 11353-1985 read with 5578-1985 all latest with upto date ammendments.
ACB/MCB/Oil circuit breaker of suitable capacity of Kilburn/L &T/MEI/GEC/Standard make on incomming feeder for motors offered by the tenderer conforming to BIS 2516-1985 latest with upto date ammendments with initial oil filling whenever required & neutral linked under voltage release.
Three phase indicating lamps complete with toggle switches for individual motors conforming to BIS 3452 part I & II latest with up to date ammendments.
Earth leakage circuit breaker/relay of recommended make such as Kilburn/L&T/MET/GEC conforming to BIS-2516-1977 with upto date ammendments and of suitaible range which should have control box, oprating handel and trip/reset push button, on/ off indicators, re-indicating off spring condition of the circut breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tap CTS. It should also be fitted earth fault for tripping of breaker on occurance of earth fault on/ of breaker load side.
Hour run meter of reputed make of four digit capacity conforming to BIS-722 (latest edition)/ recommendations.
Suitable three phase voltage monitor relay with all protections & usual indicators with electric sirens against single phasing, No/low voltage, high voltage & overloading & phase voltage difference as per IS-3842 with up to date ammendments.
Change over Switch of reputed make & suitable capacity
Single phase preventor of reputed make & suitable capacity conforming to IS:1248 (P-V)-1983 with up to date ammendments
supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/Bir/Kartar make of cast iron/cast steel double flanged sluice valve having size one size higher than the nominal delivery size of pump and capable of withstanding nominal seat pressure as mentionmed in item No. 1(a) & conforming to BIS/API-standards with up to date ammendments for delivery line of pump
(NOTE:- The sluice valve shall conform to BIS 780-1984 latest with up to date ammendments However, if the seat pressure exceeds the limits prescribed in BIS 780 then the sluice valves shall be of cast steel conforming to class 150 ASA (Seat pressure 21 Kg/cm^2) or class 300 ASA (seat pressure 52 Kg/cm^2) as per BS 1414 (API 600)
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader make of suitable size cast iron/cast steel double flanged swing check type reflux valve for delivery line of pump having bye pass arrangement & size one size higher than the nominal delivery size of pump and capable of withstanding nominal seat pressure as mentionmed in item No. 1(a) & conforming to BIS/API-standards with up to date ammendments for delivery line of pump
NOTE:- The reflux valve shall conform to BIS 5312-1984 (part I) latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 5312 then the reflux valves shall be of cast steel conforming to class 150 ASA (Seat pressure 21 Kg/cm^2) or class 300ASA (seat pressure 52 Kg/cm^2) as per BS-1414 (API600)
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/Kartar/Pelicon make of suitable size cast iron /Cast Steel double flanged swing check type reflux valve conirming to API/BIS standard with up to date ammendments for R/main as mentioned in item No.1 (c) for withstanding nominal seat pressure as per item No.1(a) The size of reflux valve shall be equal to size of Rising main of the same shall be provided with suitable bye pass arrangements.
NOTE:- The reflux valve shall conform to BIS 5312-1984 (part I) latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 5312 then the reflux valves shall be of cast steel conforming to class 150 ASA (Seat pressure 21 Kg/cm^2) or class 300 ASA (seat pressure 52 Kg/cm^2) as per BS 1414 (API 600)
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader make cast iron double flanged sluice valve (In case Suction is +ve) for suction pipe having size one or two size larger than suction size of pump such that valocity of flow in suction pipe is not more than 3.00 mtr/sec and capable of withstanding nominal seat pressure as mentionmed in item No. 1(a) & conforming to BIS/API-standards with up to date ammendments.
(NOTE:- The sluice valve shall conform to BIS 780-1984 latest with up to date ammendments However, if the seat pressure exceeds the limits prescribed in BIS 780 then the sluice valves shall be of cast steel conforming to class 150 ASA (Seat pressure 21 Kg/cm^2) or class 300 ASA (seat pressure 52 Kg/cm^2) as per BS 1414 (API 600)
P/L suitable size copper PVC insulated armoured power three & half core cable conforming to BIS 1554 (Part I) -1988 or latest with up to date ammendments of Siemen/Gloster/ ICC/EICO /National /IEC make from meter of HPSEB to circuit breaker & from circuit breaker to bus bar switch & starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles,flexible pipe,solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor. The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
P/L suitable size copper PVC insulated armoured power three core cable conforming to BIS 1554 (part I)-1988 or latest with up to date ammendments of Siemen/ Gloster /ICC/ EICO/National / IEC make from switch to starter & starter to motor (one cable carrying all three phases) including all other electrical equipment /accesories such as thimbles,flexible pipes, solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor.The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
P/L double loop earthing with copper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt ,GI pipes,thimbles,nuts & bolts,digging of pits,GI wiring & 25x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendments suitable for above motors & other electrical equipments.
Supply & errection of floor/wall mounted power factor shunt capacitor of suitable KVAR conforming to BIS 2834-1986 or latest with upto date ammendments of BHEL/GEC/Machneil/ Mager/Bajaj/L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually,of required KVAR according to HP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including L&T//Kilburn/Standard/Siemen/Havells make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer).
Supply of 100mm dia circular dial pressure gauge of suitable range & standard make such as Fiebeg/Bourden/ Precision/PREGA with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 or latest with up to date ammendments.
P/F double flanged suction, delivery pipe & common header considering site requirements, NPSH required & available & common header having area equal to two times the area of delivery branch of pump including tapers,flanges,rubber gaskets 3mm thick as per BIS-2712-1978 nuts & bolts as per 1364-1983 & special up to 5 mtrs. away from the outer wall of pump house as per layout drawings approved by Engineer-in-Charge. The pipes shall be capable of withstanding 1.5 times the total presure indicated in item no. 1 (E)-(ii). The size of suction pipe shall be one or two sizes larger than the suction size of pump such that valocity of flow in suction pipe is not more than 3.00 mtr/sec & delivery pipe shall be of size one size larger than nominal delivery size of pump.
(In case of Sumpwelll/Percolation well) or
Providing and lowering of GMS/MSERW column pipe assembly of size as included in item 1(d) including MS flanges of approperiate table capable to with stand nominal pressure as mantioned in item No 1(a) and conforming to IS 6392-1971 with up to date ammendments including the cost of rubber/ asbestos gasket of maximum 3 mm thickness as per IS-2712-1979 & required numbers of nuts & bolts as per 1364-1983 The column pipe should be provided & lowered as per direction of Engineer -in-Charge. The same shalll be of suitable thickness and grade specification capable of withstanding minimum 1.50 times the total pressure as indicated in item No 1(a) unless othewise specified and properly jointed at every three meter including all necessary accesaries like increaser / reducer , flanges , tees , bends etc. including suppoting clamps (2 Nos) at the top of assembly and as per the direction of Engineer- in- Charge.
(In case of Source is Sumpwelll/Percolation well)
Errection of all equipments from S.No.1 to 4 & 6 i/c cost of tees,bends tapers & any other fittings required as per site conditions & as per directions of Engineer-in-Charge.
Pumping machinery. ( 2nd stage ).
Supply, erection, testing & commissioning of Submersible pumping set of reputed make KSB /BS/Johnston/ Worthington conforming to latest relevent BIS code. The pump should be fitted with free flow impellers of bronze /suitable alloy as per BIS 5659 or latest with up to date ammendments suitable for raw/clear water having greased packed bearings & shell with wound stator on motor side & with shaft protection sleeve on pump side ensuring better life for shaft conforming to BIS specifications. The pump shall be directly coupled to a submersible squirrel cage electric induction motor of Kirloskar/NGEF/Jyoti / Crompton make conforming to relevent BIS code with up to date ammendments totally dust & water proof for submersible duty isolated from the pump by intermediate casing with double mechanical seal in oil chamber chamber & grease packed lubricated bearings & provided with stainless steel thrust bearing plate to withstand non vertical loads with minimum wear & tear. It should also be fitted with a device to take up expansion of water with the heating of motor . The pump set should include water level guard, errection clamps, cable clips & depth gauge etc. & suitable for operation on data given below:-
Total Head in mtrs (i/c depth of column pipe in case of t/well) 276.78 mtrs
Capacity (in LPS) 0.86 LPS
Dia of R/Main (in mm) 40 MM
Dia of column (in mm)
Supply of suitable direct on line/oil immersed star delta /ATS/stator rotor starter of standard make such as MEI/Kilburn/Jyoti/ Siemens/Larson & Tubro conforming to BIS-8544-1979 latest with up to date ammendments for squirrel cage/slip-ring motor (make to be specified by the tenderers) mounted on panel board with magnetic type over load release & dashpot,time lag,under voltage release with initial oil filling .
Note:- Star - delta - starter upto 37.5 KW , ATS between 37.5 KW to 50 KW
Providing &fixing at site M.S. sheet 16 SWG steel fabricated floor mounted closed almirah type switch board including angle iron post of suitable height and size ISA 40x40x6mm duly painted comprising and capable of mounting the following accessories with all internal electric connections. The drawing of panel board shall be subject to approval of Engineer in charge.
ICTP switches with HRC fuses of Kilburn/Larsen & Tubro/Standard/Siemen/Havells make and having capacity 30% extra of the operational rating of motor as per BIS 4064-1978 with upto date ammendments immediatly after the power meter of HPSEB.
Busbar chamber having three copper bars of suitable rating for full length equal to width of board of three live phases and one copper bar of half rating of full length for neutral conforming to BIS 8084-1976 and 11353-1985 read with 5578-1985 all latest with upto date ammendments.
ACB/MCB/Oil circuit breaker of suitable capacity of Kilburn/L &T/MEI/GEC/Standard make on incomming feeder for motors offered by the tenderer conforming to BIS 2516-1985 latest with upto date ammendments with initial oil filling whenever required & neutral linked under voltage release.
Three phase indicating lamps complete with toggle switches for individual motors conforming to BIS 3452 part I & II latest with up to date ammendments.
Earth leakage circuit breaker/relay of recommended make such as Kilburn/L&T/MET/GEC conforming to BIS-2516-1977 with upto date ammendments and of suitaible range which should have control box, oprating handel and trip/reset push button, on/ off indicators, re-indicating off spring condition of the circut breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tap CTS. It should also be fitted earth fault for tripping of breaker on occurance of earth fault on/ of breaker load side.
Hour run meter of reputed make of four digit capacity conforming to BIS-722 (latest edition)/ recommendations.
Suitable three phase voltage monitor relay with all protections & usual indicators with electric sirens against single phasing, No/low voltage, high voltage & overloading & phase voltage difference as per IS-3842 with up to date ammendments.
Change over Switch of reputed make & suitable capacity
Single phase preventor of reputed make & suitable capacity conforming to IS:1248 (P-V)-1983 with up to date ammendments
supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/Bir/Kartar make of cast iron/cast steel double flanged sluice valve having size one size higher than the nominal delivery size of pump and capable of withstanding nominal seat pressure as mentionmed in item No. 1(a) & conforming to BIS/API-standards with up to date ammendments for delivery line of pump
(NOTE:- The sluice valve shall conform to BIS 780-1984 latest with up to date ammendments However, if the seat pressure exceeds the limits prescribed in BIS 780 then the sluice valves shall be of cast steel conforming to class 150 ASA (Seat pressure 21 Kg/cm^2) or class 300 ASA (seat pressure 52 Kg/cm^2) as per BS 1414 (API 600)
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader make of suitable size cast iron/cast steel double flanged swing check type reflux valve for delivery line of pump having bye pass arrangement & size one size higher than the nominal delivery size of pump and capable of withstanding nominal seat pressure as mentionmed in item No. 1(a) & conforming to BIS/API-standards with up to date ammendments for delivery line of pump
NOTE:- The reflux valve shall conform to BIS 5312-1984 (part I) latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 5312 then the reflux valves shall be of cast steel conforming to class 150 ASA (Seat pressure 21 Kg/cm^2) or class 300ASA (seat pressure 52 Kg/cm^2) as per BS-1414 (API600)
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/Kartar/Pelicon make of suitable size cast iron /Cast Steel double flanged swing check type reflux valve conirming to API/BIS standard with up to date ammendments for R/main as mentioned in item No.1 (c) for withstanding nominal seat pressure as per item No.1(a) The size of reflux valve shall be equal to size of Rising main of the same shall be provided with suitable bye pass arrangements.
NOTE:- The reflux valve shall conform to BIS 5312-1984 (part I) latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 5312 then the reflux valves shall be of cast steel conforming to class 150 ASA (Seat pressure 21 Kg/cm^2) or class 300 ASA (seat pressure 52 Kg/cm^2) as per BS 1414 (API 600)
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader make cast iron double flanged sluice valve (In case Suction is +ve) for suction pipe having size one or two size larger than suction size of pump such that valocity of flow in suction pipe is not more than 3.00 mtr/sec and capable of withstanding nominal seat pressure as mentionmed in item No. 1(a) & conforming to BIS/API-standards with up to date ammendments.
(NOTE:- The sluice valve shall conform to BIS 780-1984 latest with up to date ammendments However, if the seat pressure exceeds the limits prescribed in BIS 780 then the sluice valves shall be of cast steel conforming to class 150 ASA (Seat pressure 21 Kg/cm^2) or class 300 ASA (seat pressure 52 Kg/cm^2) as per BS 1414 (API 600)
P/L suitable size copper PVC insulated armoured power three & half core cable conforming to BIS 1554 (Part I) -1988 or latest with up to date ammendments of Siemen/Gloster/ ICC/EICO /National /IEC make from meter of HPSEB to circuit breaker & from circuit breaker to bus bar switch & starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles,flexible pipe,solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor. The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
P/L suitable size copper PVC insulated armoured power three core cable conforming to BIS 1554 (part I)-1988 or latest with up to date ammendments of Siemen/ Gloster /ICC/ EICO/National / IEC make from switch to starter & starter to motor (one cable carrying all three phases) including all other electrical equipment /accesories such as thimbles,flexible pipes, solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor.The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
P/L double loop earthing with copper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt ,GI pipes,thimbles,nuts & bolts,digging of pits,GI wiring & 25x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendments suitable for above motors & other electrical equipments.
Supply & errection of floor/wall mounted power factor shunt capacitor of suitable KVAR conforming to BIS 2834-1986 or latest with upto date ammendments of BHEL/GEC/Machneil/ Mager/Bajaj/L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually,of required KVAR according to HP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including L&T//Kilburn/Standard/Siemen/Havells make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer).
Supply of 100mm dia circular dial pressure gauge of suitable range & standard make such as Fiebeg/Bourden/ Precision/PREGA with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 or latest with up to date ammendments.
P/F double flanged suction, delivery pipe & common header considering site requirements, NPSH required & available & common header having area equal to two times the area of delivery branch of pump including tapers,flanges,rubber gaskets 3mm thick as per BIS-2712-1978 nuts & bolts as per 1364-1983 & special up to 5 mtrs. away from the outer wall of pump house as per layout drawings approved by Engineer-in-Charge. The pipes shall be capable of withstanding 1.5 times the total presure indicated in item no. 1 (E)-(ii). The size of suction pipe shall be one or two sizes larger than the suction size of pump such that valocity of flow in suction pipe is not more than 3.00 mtr/sec & delivery pipe shall be of size one size larger than nominal delivery size of pump.
(In case of Sumpwelll/Percolation well) or
Providing and lowering of GMS/MSERW column pipe assembly of size as included in item 1(d) including MS flanges of approperiate table capable to with stand nominal pressure as mantioned in item No 1(a) and conforming to IS 6392-1971 with up to date ammendments including the cost of rubber/ asbestos gasket of maximum 3 mm thickness as per IS-2712-1979 & required numbers of nuts & bolts as per 1364-1983 The column pipe should be provided & lowered as per direction of Engineer -in-Charge. The same shalll be of suitable thickness and grade specification capable of withstanding minimum 1.50 times the total pressure as indicated in item No 1(a) unless othewise specified and properly jointed at every three meter including all necessary accesaries like increaser / reducer , flanges , tees , bends etc. including suppoting clamps (2 Nos) at the top of assembly and as per the direction of Engineer- in- Charge.
(In case of Source is Sumpwelll/Percolation well)
Errection of all equipments from S.No.9 to 12 & 14 i/c cost of tees,bends tapers & any other fittings required as per site conditions & as per directions of Engineer-in-Charge.
Pumping Machinery
1st Stage
Supply, erection, testing & commissioning of Cenrtifugal pumping set of reputed make such as KSB/BS/ Johnston/ Worthington/Suitable alloyas per BIS 5659 or latest up to date ammendments suitable for raw/clear water having greased packed bearings and shell with wound starter on motor side and with shaft protecion sleeve on pump side ensuring better life for shaft confirming BIS specifications. The pump shall be directly cuppled to a submesible squirrel cage electric induction motor of Kirlosker/NGEF/Jyoti/Crompton conforming to relevent BIS Code with upto date ammendments totaly dust and water proof for submersible duly isolated from the pump by intermediate casing with double machenical seal in oil chamber and grese packed lubricated bearings and provided with stainless steel thrust bearing plate to with stand no vertical loads with minimum wear and tear. It should also be fitted with a device take up expansion of water with the heating of motor. The pump set should include water level guard, erection clamps, cable clip and depth gauge etc and suitable for operation on data given below:-
Total Head 470.29 mtrs
Capacity of each pump set 5.89 LPS
Dia of R/Main 100 mm
Dia of column pipe (mm) 80 mm
Supply of suitable direct on line/oil immersed star delta /ATS/stator rotor starter of standard make such as MEI/Kilburn/Jyoti/ Siemens/Larson & Tubro conforming to BIS-8544-1979 latest with up to date ammendments for squirrel cage/slip-ring motor (make to be specified by the tenderers) mounted on panel board with magnetic type over load release & dashpot,time lag,under voltage release with initial oil filling .
Note:- Star - delta - starter upto 37.5 KW , ATS between 37.5 KW to 50 KW
Providing &fixing at site M.S. sheet 16 SWG steel fabricated floor mounted closed almirah type switch board including angle iron post of suitable height and size ISA 40x40x6mm duly painted comprising and capable of mounting the following accessories with all internal electric connections. The drawing of panel board shall be subject to approval of Engineer in charge.
ICTP switches with HRC fuses of Kilburn/Larsen & Tubro/Standard/Siemen/Havells make and having capacity 30% extra of the operational rating of motor as per BIS 4064-1978 with upto date ammendments immediatly after the power meter of HPSEB.
Busbar chamber having three copper bars of suitable rating for full length equal to width of board of three live phases and one copper bar of half rating of full length for neutral conforming to BIS 8084-1976 and 11353-1985 read with 5578-1985 all latest with upto date ammendments.
ACB/MCB/Oil circuit breaker of suitable capacity of Kilburn/L &T/MEI/GEC/Standard make on incomming feeder for motors offered by the tenderer conforming to BIS 2516-1985 latest with upto date ammendments with initial oil filling whenever required & neutral linked under voltage release.
Three phase indicating lamps complete with toggle switches for individual motors conforming to BIS 3452 part I & II latest with up to date ammendments.
Earth leakage circuit breaker/relay of recommended make such as Kilburn/L&T/MET/GEC conforming to BIS-2516-1977 with upto date ammendments and of suitaible range which should have control box, oprating handel and trip/reset push button, on/ off indicators, re-indicating off spring condition of the circut breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tap CTS. It should also be fitted earth fault for tripping of breaker on occurance of earth fault on/ of breaker load side.
Hour run meter of reputed make of four digit capacity conforming to BIS-722 (latest edition)/ recommendations.
Suitable three phase voltage monitor relay with all protections & usual indicators with electric sirens against single phasing, No/low voltage, high voltage & overloading & phase voltage difference as per IS-3842 with up to date ammendments.
Change over Switch of reputed make & suitable capacity
Single phase preventor of reputed make & suitable capacity conforming to IS:1248 (P-V)-1983 with up to date ammendments
supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/Bir/Kartar make of cast iron/cast steel double flanged sluice valve having size one size higher than the nominal delivery size of pump and capable of withstanding nominal seat pressure as mentionmed in item No. 1(a) & conforming to BIS/API-standards with up to date ammendments for delivery line of pump
(NOTE:- The sluice valve shall conform to BIS 780-1984 latest with up to date ammendments However, if the seat pressure exceeds the limits prescribed in BIS 780 then the sluice valves shall be of cast steel conforming to class 150 ASA (Seat pressure 21 Kg/cm^2) or class 300 ASA (seat pressure 52 Kg/cm^2) as per BS 1414 (API 600)
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader make of suitable size cast iron/cast steel double flanged swing check type reflux valve for delivery line of pump having bye pass arrangement & size one size higher than the nominal delivery size of pump and capable of withstanding nominal seat pressure as mentionmed in item No. 1(a) & conforming to BIS/API-standards with up to date ammendments for delivery line of pump
NOTE:- The reflux valve shall conform to BIS 5312-1984 (part I) latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 5312 then the reflux valves shall be of cast steel conforming to class 150 ASA (Seat pressure 21 Kg/cm^2) or class 300ASA (seat pressure 52 Kg/cm^2) as per BS-1414 (API600)
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/Kartar/Pelicon make of suitable size cast iron /Cast Steel double flanged swing check type reflux valve conirming to API/BIS standard with up to date ammendments for R/main as mentioned in item No.1 (c) for withstanding nominal seat pressure as per item No.1(a) The size of reflux valve shall be equal to size of Rising main of the same shall be provided with suitable bye pass arrangements.
NOTE:- The reflux valve shall conform to BIS 5312-1984 (part I) latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 5312 then the reflux valves shall be of cast steel conforming to class 150 ASA (Seat pressure 21 Kg/cm^2) or class 300 ASA (seat pressure 52 Kg/cm^2) as per BS 1414 (API 600)
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader make cast iron double flanged sluice valve (In case Suction is +ve) for suction pipe having size one or two size larger than suction size of pump such that valocity of flow in suction pipe is not more than 3.00 mtr/sec and capable of withstanding nominal seat pressure as mentionmed in item No. 1(a) & conforming to BIS/API-standards with up to date ammendments.
(NOTE:- The sluice valve shall conform to BIS 780-1984 latest with up to date ammendments However, if the seat pressure exceeds the limits prescribed in BIS 780 then the sluice valves shall be of cast steel conforming to class 150 ASA (Seat pressure 21 Kg/cm^2) or class 300 ASA (seat pressure 52 Kg/cm^2) as per BS 1414 (API 600)
P/L suitable size copper PVC insulated armoured power three & half core cable conforming to BIS 1554 (Part I) -1988 or latest with up to date ammendments of Siemen/Gloster/ ICC/EICO /National /IEC make from meter of HPSEB to circuit breaker & from circuit breaker to bus bar switch & starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles,flexible pipe,solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor. The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
P/L suitable size copper PVC insulated armoured power three core cable conforming to BIS 1554 (part I)-1988 or latest with up to date ammendments of Siemen/ Gloster /ICC/ EICO/National / IEC make from switch to starter & starter to motor (one cable carrying all three phases) including all other electrical equipment /accesories such as thimbles,flexible pipes, solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor.The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
P/L double loop earthing with copper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt ,GI pipes,thimbles,nuts & bolts,digging of pits,GI wiring & 25x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendments suitable for above motors & other electrical equipments.
Supply & errection of floor/wall mounted power factor shunt capacitor of suitable KVAR conforming to BIS 2834-1986 or latest with upto date ammendments of BHEL/GEC/Machneil/ Mager/Bajaj/L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually,of required KVAR according to HP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including L&T//Kilburn/Standard/Siemen/Havells make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer).
Supply of 100mm dia circular dial pressure gauge of suitable range & standard make such as Fiebeg/Bourden/ Precision/PREGA with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 or latest with up to date ammendments.
P/F double flanged suction, delivery pipe & common header considering site requirements, NPSH required & available & common header having area equal to two times the area of delivery branch of pump including tapers,flanges,rubber gaskets 3mm thick as per BIS-2712-1978 nuts & bolts as per 1364-1983 & special up to 5 mtrs. away from the outer wall of pump house as per layout drawings approved by Engineer-in-Charge. The pipes shall be capable of withstanding 1.5 times the total presure indicated in item no. 1 (E)-(ii). The size of suction pipe shall be one or two sizes larger than the suction size of pump such that valocity of flow in suction pipe is not more than 3.00 mtr/sec & delivery pipe shall be of size one size larger than nominal delivery size of pump.
(In case of Sumpwelll/Percolation well) or
Providing and lowering of GMS/MSERW column pipe assembly of size as included in item 1(d) including MS flanges of approperiate table capable to with stand nominal pressure as mantioned in item No 1(a) and conforming to IS 6392-1971 with up to date ammendments including the cost of rubber/ asbestos gasket of maximum 3 mm thickness as per IS-2712-1979 & required numbers of nuts & bolts as per 1364-1983 The column pipe should be provided & lowered as per direction of Engineer -in-Charge. The same shalll be of suitable thickness and grade specification capable of withstanding minimum 1.50 times the total pressure as indicated in item No 1(a) unless othewise specified and properly jointed at every three meter including all necessary accesaries like increaser / reducer , flanges , tees , bends etc. including suppoting clamps (2 Nos) at the top of assembly and as per the direction of Engineer- in- Charge.
(In case of Source is Sumpwelll/Percolation well)
Errection of all equipments from S.No.1 to 4 & 6 i/c cost of tees,bends tapers & any other fittings required as per site conditions & as per directions of Engineer-in-Charge.
2nd Stage Phase I
Supply, erection, testing & commissioning of Cenrtifugal pumping set of reputed make such as KSB/BS/ Johnston/ Worthington/Suitable alloyas per BIS 5659 or latest up to date ammendments suitable for raw/clear water having greased packed bearings and shell with wound starter on motor side and with shaft protecion sleeve on pump side ensuring better life for shaft confirming BIS specifications. The pump shall be directly cuppled to a submesible squirrel cage electric induction motor of Kirlosker/NGEF/Jyoti/Crompton conforming to relevent BIS Code with upto date ammendments totaly dust and water proof for submersible duly isolated from the pump by intermediate casing with double machenical seal in oil chamber and grese packed lubricated bearings and provided with stainless steel thrust bearing plate to with stand no vertical loads with minimum wear and tear. It should also be fitted with a device take up expansion of water with the heating of motor. The pump set should include water level guard, erection clamps, cable clip and depth gauge etc and suitable for operation on data given below:-
Total Head 122.62 mtrs
Capacity of each pump set 4.26 LPS
Dia of R/Main 80 MM
Dia of column pipe (mm) 65 mm
Supply of suitable direct on line/oil immersed star delta /ATS/stator rotor starter of standard make such as MEI/Kilburn/Jyoti/ Siemens/Larson & Tubro conforming to BIS-8544-1979 latest with up to date ammendments for squirrel cage/slip-ring motor (make to be specified by the tenderers) mounted on panel board with magnetic type over load release & dashpot,time lag,under voltage release with initial oil filling .
Note:- Star - delta - starter upto 37.5 KW , ATS between 37.5 KW to 50 KW
Providing &fixing at site M.S. sheet 16 SWG steel fabricated floor mounted closed almirah type switch board including angle iron post of suitable height and size ISA 40x40x6mm duly painted comprising and capable of mounting the following accessories with all internal electric connections. The drawing of panel board shall be subject to approval of Engineer in charge.
ICTP switches with HRC fuses of Kilburn/Larsen & Tubro/Standard/Siemen/Havells make and having capacity 30% extra of the operational rating of motor as per BIS 4064-1978 with upto date ammendments immediatly after the power meter of HPSEB.
Busbar chamber having three copper bars of suitable rating for full length equal to width of board of three live phases and one copper bar of half rating of full length for neutral conforming to BIS 8084-1976 and 11353-1985 read with 5578-1985 all latest with upto date ammendments.
ACB/MCB/Oil circuit breaker of suitable capacity of Kilburn/L &T/MEI/GEC/Standard make on incomming feeder for motors offered by the tenderer conforming to BIS 2516-1985 latest with upto date ammendments with initial oil filling whenever required & neutral linked under voltage release.
Three phase indicating lamps complete with toggle switches for individual motors conforming to BIS 3452 part I & II latest with up to date ammendments.
Earth leakage circuit breaker/relay of recommended make such as Kilburn/L&T/MET/GEC conforming to BIS-2516-1977 with upto date ammendments and of suitaible range which should have control box, oprating handel and trip/reset push button, on/ off indicators, re-indicating off spring condition of the circut breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tap CTS. It should also be fitted earth fault for tripping of breaker on occurance of earth fault on/ of breaker load side.
Hour run meter of reputed make of four digit capacity conforming to BIS-722 (latest edition)/ recommendations.
Suitable three phase voltage monitor relay with all protections & usual indicators with electric sirens against single phasing, No/low voltage, high voltage & overloading & phase voltage difference as per IS-3842 with up to date ammendments.
Change over Switch of reputed make & suitable capacity
Single phase preventor of reputed make & suitable capacity conforming to IS:1248 (P-V)-1983 with up to date ammendments
supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/Bir/Kartar make of cast iron/cast steel double flanged sluice valve having size one size higher than the nominal delivery size of pump and capable of withstanding nominal seat pressure as mentionmed in item No. 1(a) & conforming to BIS/API-standards with up to date ammendments for delivery line of pump
(NOTE:- The sluice valve shall conform to BIS 780-1984 latest with up to date ammendments However, if the seat pressure exceeds the limits prescribed in BIS 780 then the sluice valves shall be of cast steel conforming to class 150 ASA (Seat pressure 21 Kg/cm^2) or class 300 ASA (seat pressure 52 Kg/cm^2) as per BS 1414 (API 600)
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader make of suitable size cast iron/cast steel double flanged swing check type reflux valve for delivery line of pump having bye pass arrangement & size one size higher than the nominal delivery size of pump and capable of withstanding nominal seat pressure as mentionmed in item No. 1(a) & conforming to BIS/API-standards with up to date ammendments for delivery line of pump
NOTE:- The reflux valve shall conform to BIS 5312-1984 (part I) latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 5312 then the reflux valves shall be of cast steel conforming to class 150 ASA (Seat pressure 21 Kg/cm^2) or class 300ASA (seat pressure 52 Kg/cm^2) as per BS-1414 (API600)
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/Kartar/Pelicon make of suitable size cast iron /Cast Steel double flanged swing check type reflux valve conirming to API/BIS standard with up to date ammendments for R/main as mentioned in item No.1 (c) for withstanding nominal seat pressure as per item No.1(a) The size of reflux valve shall be equal to size of Rising main of the same shall be provided with suitable bye pass arrangements.
NOTE:- The reflux valve shall conform to BIS 5312-1984 (part I) latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 5312 then the reflux valves shall be of cast steel conforming to class 150 ASA (Seat pressure 21 Kg/cm^2) or class 300 ASA (seat pressure 52 Kg/cm^2) as per BS 1414 (API 600)
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader make cast iron double flanged sluice valve (In case Suction is +ve) for suction pipe having size one or two size larger than suction size of pump such that valocity of flow in suction pipe is not more than 3.00 mtr/sec and capable of withstanding nominal seat pressure as mentionmed in item No. 1(a) & conforming to BIS/API-standards with up to date ammendments.
(NOTE:- The sluice valve shall conform to BIS 780-1984 latest with up to date ammendments However, if the seat pressure exceeds the limits prescribed in BIS 780 then the sluice valves shall be of cast steel conforming to class 150 ASA (Seat pressure 21 Kg/cm^2) or class 300 ASA (seat pressure 52 Kg/cm^2) as per BS 1414 (API 600)
P/L suitable size copper PVC insulated armoured power three & half core cable conforming to BIS 1554 (Part I) -1988 or latest with up to date ammendments of Siemen/Gloster/ ICC/EICO /National /IEC make from meter of HPSEB to circuit breaker & from circuit breaker to bus bar switch & starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles,flexible pipe,solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor. The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
P/L suitable size copper PVC insulated armoured power three core cable conforming to BIS 1554 (part I)-1988 or latest with up to date ammendments of Siemen/ Gloster /ICC/ EICO/National / IEC make from switch to starter & starter to motor (one cable carrying all three phases) including all other electrical equipment /accesories such as thimbles,flexible pipes, solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor.The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
P/L double loop earthing with copper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt ,GI pipes,thimbles,nuts & bolts,digging of pits,GI wiring & 25x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendments suitable for above motors & other electrical equipments.
Supply & errection of floor/wall mounted power factor shunt capacitor of suitable KVAR conforming to BIS 2834-1986 or latest with upto date ammendments of BHEL/GEC/Machneil/ Mager/Bajaj/L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually,of required KVAR according to HP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including L&T//Kilburn/Standard/Siemen/Havells make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer).
Supply of 100mm dia circular dial pressure gauge of suitable range & standard make such as Fiebeg/Bourden/ Precision/PREGA with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 or latest with up to date ammendments.
P/F double flanged suction, delivery pipe & common header considering site requirements, NPSH required & available & common header having area equal to two times the area of delivery branch of pump including tapers,flanges,rubber gaskets 3mm thick as per BIS-2712-1978 nuts & bolts as per 1364-1983 & special up to 5 mtrs. away from the outer wall of pump house as per layout drawings approved by Engineer-in-Charge. The pipes shall be capable of withstanding 1.5 times the total presure indicated in item no. 1 (E)-(ii). The size of suction pipe shall be one or two sizes larger than the suction size of pump such that valocity of flow in suction pipe is not more than 3.00 mtr/sec & delivery pipe shall be of size one size larger than nominal delivery size of pump.
(In case of Sumpwelll/Percolation well)
Providing and lowering of GMS/MSERW column pipe assembly of size as included in item 1(d) including MS flanges of approperiate table capable to with stand nominal pressure as mantioned in item No 1(a) and conforming to IS 6392-1971 with up to date ammendments including the cost of rubber/ asbestos gasket of maximum 3 mm thickness as per IS-2712-1979 & required numbers of nuts & bolts as per 1364-1983 The column pipe should be provided & lowered as per direction of Engineer -in-Charge. The same shalll be of suitable thickness and grade specification capable of withstanding minimum 1.50 times the total pressure as indicated in item No 1(a) unless othewise specified and properly jointed at every three meter including all necessary accesaries like increaser / reducer , flanges , tees , bends etc. including suppoting clamps (2 Nos) at the top of assembly and as per the direction of Engineer- in- Charge.
(In case of Source is Sumpwelll/Percolation well)
Errection of all equipments from S.No.1 to 4 & 6 i/c cost of tees,bends tapers & any other fittings required as per site conditions & as per directions of Engineer-in-Charge.
2nd Stage Phase II
Supply, erection, testing & commissioning of Cenrtifugal pumping set of reputed make such as KSB/BS/ Johnston/ Worthington/Suitable alloyas per BIS 5659 or latest up to date ammendments suitable for raw/clear water having greased packed bearings and shell with wound starter on motor side and with shaft protecion sleeve on pump side ensuring better life for shaft confirming BIS specifications. The pump shall be directly cuppled to a submesible squirrel cage electric induction motor of Kirlosker/NGEF/Jyoti/Crompton conforming to relevent BIS Code with upto date ammendments totaly dust and water proof for submersible duly isolated from the pump by intermediate casing with double machenical seal in oil chamber and grese packed lubricated bearings and provided with stainless steel thrust bearing plate to with stand no vertical loads with minimum wear and tear. It should also be fitted with a device take up expansion of water with the heating of motor. The pump set should include water level guard, erection clamps, cable clip and depth gauge etc and suitable for operation on data given below:-
Total Head 560.20 mtrs
Capacity of each pump set 1.62 LPS
Dia of R/Main 50 mm
Dia of column pipe (mm) 40 mm
Supply of suitable direct on line/oil immersed star delta /ATS/stator rotor starter of standard make such as MEI/Kilburn/Jyoti/ Siemens/Larson & Tubro conforming to BIS-8544-1979 latest with up to date ammendments for squirrel cage/slip-ring motor (make to be specified by the tenderers) mounted on panel board with magnetic type over load release & dashpot,time lag,under voltage release with initial oil filling .
Note:- Star - delta - starter upto 37.5 KW , ATS between 37.5 KW to 50 KW
Providing &fixing at site M.S. sheet 16 SWG steel fabricated floor mounted closed almirah type switch board including angle iron post of suitable height and size ISA 40x40x6mm duly painted comprising and capable of mounting the following accessories with all internal electric connections. The drawing of panel board shall be subject to approval of Engineer in charge.
ICTP switches with HRC fuses of Kilburn/Larsen & Tubro/Standard/Siemen/Havells make and having capacity 30% extra of the operational rating of motor as per BIS 4064-1978 with upto date ammendments immediatly after the power meter of HPSEB.
Busbar chamber having three copper bars of suitable rating for full length equal to width of board of three live phases and one copper bar of half rating of full length for neutral conforming to BIS 8084-1976 and 11353-1985 read with 5578-1985 all latest with upto date ammendments.
ACB/MCB/Oil circuit breaker of suitable capacity of Kilburn/L &T/MEI/GEC/Standard make on incomming feeder for motors offered by the tenderer conforming to BIS 2516-1985 latest with upto date ammendments with initial oil filling whenever required & neutral linked under voltage release.
Three phase indicating lamps complete with toggle switches for individual motors conforming to BIS 3452 part I & II latest with up to date ammendments.
Earth leakage circuit breaker/relay of recommended make such as Kilburn/L&T/MET/GEC conforming to BIS-2516-1977 with upto date ammendments and of suitaible range which should have control box, oprating handel and trip/reset push button, on/ off indicators, re-indicating off spring condition of the circut breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tap CTS. It should also be fitted earth fault for tripping of breaker on occurance of earth fault on/ of breaker load side.
Hour run meter of reputed make of four digit capacity conforming to BIS-722 (latest edition)/ recommendations.
Suitable three phase voltage monitor relay with all protections & usual indicators with electric sirens against single phasing, No/low voltage, high voltage & overloading & phase voltage difference as per IS-3842 with up to date ammendments.
Change over Switch of reputed make & suitable capacity
Single phase preventor of reputed make & suitable capacity conforming to IS:1248 (P-V)-1983 with up to date ammendments
supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/Bir/Kartar make of cast iron/cast steel double flanged sluice valve having size one size higher than the nominal delivery size of pump and capable of withstanding nominal seat pressure as mentionmed in item No. 1(a) & conforming to BIS/API-standards with up to date ammendments for delivery line of pump
(NOTE:- The sluice valve shall conform to BIS 780-1984 latest with up to date ammendments However, if the seat pressure exceeds the limits prescribed in BIS 780 then the sluice valves shall be of cast steel conforming to class 150 ASA (Seat pressure 21 Kg/cm^2) or class 300 ASA (seat pressure 52 Kg/cm^2) as per BS 1414 (API 600)
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader make of suitable size cast iron/cast steel double flanged swing check type reflux valve for delivery line of pump having bye pass arrangement & size one size higher than the nominal delivery size of pump and capable of withstanding nominal seat pressure as mentionmed in item No. 1(a) & conforming to BIS/API-standards with up to date ammendments for delivery line of pump
NOTE:- The reflux valve shall conform to BIS 5312-1984 (part I) latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 5312 then the reflux valves shall be of cast steel conforming to class 150 ASA (Seat pressure 21 Kg/cm^2) or class 300ASA (seat pressure 52 Kg/cm^2) as per BS-1414 (API600)
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/Kartar/Pelicon make of suitable size cast iron /Cast Steel double flanged swing check type reflux valve conirming to API/BIS standard with up to date ammendments for R/main as mentioned in item No.1 (c) for withstanding nominal seat pressure as per item No.1(a) The size of reflux valve shall be equal to size of Rising main of the same shall be provided with suitable bye pass arrangements.
NOTE:- The reflux valve shall conform to BIS 5312-1984 (part I) latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 5312 then the reflux valves shall be of cast steel conforming to class 150 ASA (Seat pressure 21 Kg/cm^2) or class 300 ASA (seat pressure 52 Kg/cm^2) as per BS 1414 (API 600)
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader make cast iron double flanged sluice valve (In case Suction is +ve) for suction pipe having size one or two size larger than suction size of pump such that valocity of flow in suction pipe is not more than 3.00 mtr/sec and capable of withstanding nominal seat pressure as mentionmed in item No. 1(a) & conforming to BIS/API-standards with up to date ammendments.
(NOTE:- The sluice valve shall conform to BIS 780-1984 latest with up to date ammendments However, if the seat pressure exceeds the limits prescribed in BIS 780 then the sluice valves shall be of cast steel conforming to class 150 ASA (Seat pressure 21 Kg/cm^2) or class 300 ASA (seat pressure 52 Kg/cm^2) as per BS 1414 (API 600)
P/L suitable size copper PVC insulated armoured power three & half core cable conforming to BIS 1554 (Part I) -1988 or latest with up to date ammendments of Siemen/Gloster/ ICC/EICO /National /IEC make from meter of HPSEB to circuit breaker & from circuit breaker to bus bar switch & starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles,flexible pipe,solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor. The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
P/L suitable size copper PVC insulated armoured power three core cable conforming to BIS 1554 (part I)-1988 or latest with up to date ammendments of Siemen/ Gloster /ICC/ EICO/National / IEC make from switch to starter & starter to motor (one cable carrying all three phases) including all other electrical equipment /accesories such as thimbles,flexible pipes, solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor.The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
P/L double loop earthing with copper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt ,GI pipes,thimbles,nuts & bolts,digging of pits,GI wiring & 25x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendments suitable for above motors & other electrical equipments.
Supply & errection of floor/wall mounted power factor shunt capacitor of suitable KVAR conforming to BIS 2834-1986 or latest with upto date ammendments of BHEL/GEC/Machneil/ Mager/Bajaj/L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually,of required KVAR according to HP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including L&T//Kilburn/Standard/Siemen/Havells make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer).
Supply of 100mm dia circular dial pressure gauge of suitable range & standard make such as Fiebeg/Bourden/ Precision/PREGA with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 or latest with up to date ammendments.
P/F double flanged suction, delivery pipe & common header considering site requirements, NPSH required & available & common header having area equal to two times the area of delivery branch of pump including tapers,flanges,rubber gaskets 3mm thick as per BIS-2712-1978 nuts & bolts as per 1364-1983 & special up to 5 mtrs. away from the outer wall of pump house as per layout drawings approved by Engineer-in-Charge. The pipes shall be capable of withstanding 1.5 times the total presure indicated in item no. 1 (E)-(ii). The size of suction pipe shall be one or two sizes larger than the suction size of pump such that valocity of flow in suction pipe is not more than 3.00 mtr/sec & delivery pipe shall be of size one size larger than nominal delivery size of pump.
(In case of Sumpwelll/Percolation well)
Providing and lowering of GMS/MSERW column pipe assembly of size as included in item 1(d) including MS flanges of approperiate table capable to with stand nominal pressure as mantioned in item No 1(a) and conforming to IS 6392-1971 with up to date ammendments including the cost of rubber/ asbestos gasket of maximum 3 mm thickness as per IS-2712-1979 & required numbers of nuts & bolts as per 1364-1983 The column pipe should be provided & lowered as per direction of Engineer -in-Charge. The same shalll be of suitable thickness and grade specification capable of withstanding minimum 1.50 times the total pressure as indicated in item No 1(a) unless othewise specified and properly jointed at every three meter including all necessary accesaries like increaser / reducer , flanges , tees , bends etc. including suppoting clamps (2 Nos) at the top of assembly and as per the direction of Engineer- in- Charge.
(In case of Source is Sumpwelll/Percolation well)
Errection of all equipments from S.No.1 to 4 & 6 i/c cost of tees,bends tapers & any other fittings required as per site conditions & as per directions of Engineer-in-Charge.
Rising Main
Excavation in drains and channels etc, in earth work in all kinds of soil such as kankar Moorum, shingles, Coglomerate saturated soil decomposed or soft rock and hard rock by blasting by chiselling (where blasting prohabitated) including dressing of sides and beds disposing of excavated earth with all leads and lifts disposed earth to be levelled and neatly dressed and then returning the stacked soil into foundation and trenches, etc, including ramming and consolidating the same wherever required with all leads and lifts and including jungle clearance and as per direction of Engieer-in-charge
Providing, laying, testing & commissioning at site in trenches bevelled ended MSERW pipes confirming of various Grades confirming to IS/ISO 3183-2017, latest with up to date amendments having wall thickness & per Rmt weight as mentioned below & capable of withstanding required test pressure as prescribed in BIS code, in random lengths of 5.5 to 6.5 mtr. The pipes ends shall be bevelled suitable for butt welding including the cost of jointing with butt welding confirming to IS 816-1969 or latest as applicable ends with up to date ammendments (leak proof) in three layers at site of work with welding rods of standard make and allied accessories whatever required welding at site,tails pieces, tees,bends & other specials manufactured from parent pipes as applicable to the particular reach & of approved specification as per site conditions and cutting of pipes wherever required as per site requirement including carriage in all leads & lifts and as directed by Engineer-Incharge. The pipe shall have zinc coating inside & outside confirming to IS-4736-1986 or latest with up to date ammendments The laying shall confirm to BIS 5822-1970 or latest with up to date ammendments to the entire satisfaction of Engineer-Incharge (Earth work shall be measured & paid for seperately).
GP Naya Panjor
Stage 1st
Dia From RD to RD wall thicness FT Grade
GP Panog
STAGE 1ST
Dia From RD to RD wall thicness FT Grade
100mm 0 900 4.80 34 X-42 or L-290
100mm 900 1200 4.80 28 X-42 or L-290
STAGE 2ND Phase II
50mm 0 300 4.80 34 Grade-A or L-210
Laying, jointing , testing & commissioning at site in trenches bevelled ended GMS pipes of various diameter of heavy/medium grades as under confirfirming to BIS 1239 (PART-1) 1990 as latest with upto date amendements having wall thicness & per Rmt weight as mantioned below and capable of with standing required test pressure as prescribed in BIS code in random lengths of 5.5 to 6.5 mtr. The pipes ends shall be bevelled suitable for butt welding including the cost of jointing with butt welding conforming to IS 816-1969 or latest as applicable (leak proof) in three layers at site of work with welding rods of standard make and all allied accessories whatever required for welding at site, tail pieces, tees, bends and other specials manufactured from parent pipes as applicable to the particular reach & of approved specification as per site conditions and cutting of pipes wherever required as per site requirement including carriage in all leads & lifts and as directed by Engineer-Incharge. The pipe shall have zinc coating inside & outside confirming to IS-4736-1986 or latest with up to date ammendments The laying shall confirm to BIS 5822-1970 or latest with up to date ammendments to the entire satisfaction of Engineer-Incharge (Earth work shall be measured & paid for seperately).
GP Naya Panjor
Stage 1st
Dia From RD to RD wall thicness FT Grade
80mm 1500 1810 4.00 17 GI (M)
Stage 2nd
40mm 0 600 4.00 28 GI Heavy
40mm 600 1300 3.20 5 GI (M)
GP Panog
STAGE 1ST
Dia From RD to RD wall thicness FT Grade
100mm 1200 1450 4.00 5 GI (M)
STAGE 2ND Phase I
80mm 0 100 4.80 17 GI (H)
80mm 100 350 4.00 5 GI (M)
STAGE 2ND Phase II
50mm 300 600 4.50 17 GI (H)
50mm 600 900 3.65 5 GI (M)
Providing welding and fixing M.S plate flanges of following dia (nominal bore) of following flange Table conforming to IS 6392-1971 or latest with upto date amendments to MSERW/G.I. pipe after every 100 metres or as per site requirement including cutting of pipes wherever required welding in three layers (leak proof) conforming to specifications as prescribed in relevent IS code i.e IS 816-1969 or latest as applicable with upto date amendments with nuts, bolts & washers and specials etc. conforming to IS 1963 or latest with upto date amendments including packing sheet i.e. asbestos fibre sheet minimum 3mm thick and painting with anticrossive paints complete in all respect in all leads lifts and carriage of material at site and as directed by the Engineer-in-charge.
GP Naya Panjor
STAGE 1ST
Dia From RD to RD wall thicness FT
Stage 2nd
GP Panog
STAGE 1ST
Dia From RD to RD wall thicness FT Grade
STAGE 2ND Phase II
STAGE 1st and 2ND
STAGE 2ND Phase 1st
STAGE 2ND Phase II
Civil work
Cutting in earth wark and dispose of excavated earth all leads in P/J work 50%
Excavation in foundation and trenches etc.in earth work in all kinds of soil such as pick work ,jumper work decomposed conglomerate saturated soil soft and hard rock upto all leads lifts stacking the excavated soil not more than 3mtr.clear from the edge of excavation and then returning the stacked soil in 15cm layers when required in to plinth sides of foundation etc. consolidating each deposited layers by ramming and watering and then disposing of all surplus excavated earth as directed with in all leads lifts and as per directions of the Engineer-incharge 20mtrs in all kind of soil in P.W & J.W 50% each
Providing and laying cement concrete 1:4:8(1cement:4sand:8 graded stone agg.40mm nominal size)and curing complete excluding the cost of form work in foundation & plinth including all leads lifts and carriage of material and as per the directions of Engineer-in-charge.
Providing and laying cement concrete 1:6:12(1cement:6sand:12 graded stone agg.40mm nominal size)and curing complete excluding the cost of form work in foundation & plinth including all leads lifts and carriage of material and as per the directions of Engineer-in-charge.
Providing and laying cement concrete 1:5:10 (1cement: 5app.sand: 10app. graded stone agg. 40mm nominal size) with 15% plum and curing complete excluding the cost of form work in retaining wall/ breast wall the size of plums shall be 150mm to 300mm as per HP specifications including all leads lifts and carriage of material at site and as directed by the Engineer in charge.
Providing and laying cement concrete work 1:1/2:3 (1cement:1-1/2 sand: 3 gradeds stone agg. 20mm nominal size & curing complete) excluding cost of form work and reinforcement for RCC work including all leads lifts complete and carriage of material etc. as per directions of Engineer incharge.
a) Foundation and plinth
b) In vertical wall any thickness but not less than 0.10 mtrs thick
Random rubble masonry / polygonal rubble masonry(Uncoursed/ brought to course) with hard stone ofapproved quality in foundation and plinth including levelling up with cement concerete 1:6:12 (1Cement:6 Sand : 12 Graded stone aggrete of 20 mm nominal size) in cement mortar 1:6 (1cement:6Sand ) in foundation and plinth i/c all leads, lifts and carriage of material etc. and as direction by the Engineer in Charge completed in all respect
Square rubble masonry course with hard stone of approved quality in foundation and plinth including racking out joints in cement motar 1:4 (1Cement: 4Sand )
Providing and laying Damp proof course 38mm thik cement concrete 1:2:4(1cement:2sand:4 graded stone agg. 12.55mm nominal size)and plinth level and curring.
Applying a coat of hot bitumin [mexphalt 80/100 or equivelent using 1.70 kg/sq.mt. on D.P.C. after cleaning the surface with a piece of cloth lightly soaked with kerosene oil.]
1st class brick work using common burt clays building bricks in super structure in cement otar 1:6(1 cement : 6 sand)2nd class brick .
Providing and fixcing pressed steel door frames manufactured from commercial mild steel of 1.25 mm thicknesss including hinges jamb lock jamb by machinical beed and if required angle of section 50*25 mm or base ties of 1.25 mm pressed mild steel welded orrigidly fixed together and specified and applying a coat of appr. steeel primer after pretretment of the surface as direct by the engineer in charge including all leads lifts and carriage of material at site and as directed by the engineer in charge
Providing 40x3mm flat iron hold fast 40 cm long including fixing to frames 10 mm dia. Bolts and nuts and wooden plug and embend in cement concrete block 30x10x15cm in 1:3:6 (1cement : 3 sand :6 gradedstone agg. 20mm nominal size )
Providing form work with steel plates 3.15 thick welded with angle iron in frame 30X30X5mm so as to give rough finish including centering shuttering strutting and propping etc. with wooden battens and bellies, highs or propping and centering below supporting floor to ceiling not exceeding 4mtrs and removal of the same for insitu- RCC work and PCC work including all leads lifts and carriage of material at site and as per direction of Engineer in charge in : -
Flat surfaces such as sofits and suspended floors, roofs landing and the like floors etc. up to 200 mm in thickness.
Vertical surface such as wall (any thickness. Partition and the like i/c attached plasters, buttress , plinth and string course and the like.
Providing and laying cement concrete work :1.5:3 (1cement:1-1.5 sand: 3 gradeds stone agg. 20mm nominal size & curing complete) excluding cost of form work and reinforcement for rainforced conrete work in lintels, beams, and girders bresummers and cantilever up to floor two level.
Providing and laying cement concrete 1:2:4 (1cement : 2 app. sand : 4app. graded stone agg. 20mm nominal size) and curing complete excluding cost of form work and reinforcement for reinforced work in suspended floors, roofs landings shelves and their supports balconies, beams, girders bressumers and cantilevers up to floor two level in all height and depth, including all leads lifts and carriage of material at site and as per directions of the Engineer in charge.
Providing Mild Steel/Tor steel reinforcement for RCC work including bending binding & placing in positing I/c all leads lifts and carriage of material and as per direction of the Engineer-in-charge.
Providing and fixing 200mm wide C.I. rugs with chequered of rubber or non- slip surface including fixing in tank with 200x200mm C.C.1:3:6 (1cement : 3 app. sand : 6app. graded stone agg. 20mm nominal size)
Suplying Cast iron manhole cover of 455x610 mm size C.I.(medium)duty the weight of manhole cover not less than 23 kgs.including all leads lifts and carriage of materials as per direction of the Engineer-in-charge.
Steel work welded in builtup section, Trusses & famed work i/c cutting hoisting fixing in position and applying a printing coat of red lead paint ingrating framed guard bars ladders railing , bracckets and similar items.
Proving and fixing M.S. foot rest of 22mm dia size including embedded in C.C in block 225 mm X 225mmX75mm including all leads and carriage of material at site as per direction of Engineer in Charge
Providing and laying Brick layer in cm 1:3 in inner Drain
Providing and placing horizontal layers filtering media duly graded screened washed and cleaned as specification by the Engineer in Charge
Top Layer
Second Layer Coursed Sand
Third Layer Bazari 6mm to20mm
Fourth Layer 20mm to25mm
Fifth Layer Broken Stone
Providing and fixing M.S. grills of required pattern in wooden frames of window etc. with M.S. flats squar or rounded bars with rounded headed bolts and nuts or by screws.
Providing and fixing 1 mm thick M.S. sheet door with frames of 40x40x6mm angle iron 3.13mm M.S. guest plate at the juctions and corners ,all necessary fiotting complete including applying a primery coat pof red lead paint
Applying priming coat over new wood and wood based surfaces after and including preparing the surface by throughly cleaning oil grease & dirt and other foreigm matter and sand parering and knotting ready mixed paint brushing stell primer red oxuide paint.
Painting two coats(excluding priming coat) on new steel and steel based surfaces with ready mixed paint brushing to give even shade including cleaning all dirt, dust and other foreign matter white paint
Boulder filling under floor packed tightly including all leads & lifts as per the direction of Engineer- in- charge
Cement concrete 1:2:4 (1cement : 2 app. sand : 4app. graded stone agg. 40mm nominal size) laid in one layer finished with a floating coat of near cement 40mm thik.
15 mm thick cement plaster in single coat of rough side of bricks/stone masonary for interior plastering upto floor two level including arrises internal rounded angles chamfers rounded angles not exceeding 80mm in girth and finished even and smooth in cement mortor 1:3(1cement:3 sand) and curing complete including all leads lifts and carriage of materials at site as per direction of Engineer-incharge.
6 mm thick cement plastering in cement mortar 1;3 (1Cement 3sand) including all leads lift and carriage of materials at site as per direction of Engineer-incharge.
White washing with lime on un-decorated walls surfaces two coats to give an even shade including thoroughly brooming the surfaces to remove all dirt and dust and other foreign matter
Hiramchi colour wash on un decorated wall surface( two coat ) to give an even shade including thoughtly brooming the surface tom removal of oil grease , dirt dust and other forgin matter.
Providing under layer 75mm thick unconsolidated bed dryb brick/stone (40mm nominal size) including finishing top surface
Providing plinth protection 50mm thick in cement concrete 1:3:6 (1 Cement: 3sand: 6graded stone agg. 20mm nominal size) including finishing the top surfaces of concrete smooth.
Providing and fixing oxiozed Alumunium sliding door bolts with nuts and screws etc. .300mmX16mm
Providing and fixing tower bolts (barrel type) 250X10mm
Providing and fixing oxidized alumunium handle with screws 100mm
Distribution system
Excavation in drains and channels etc. in earth work in all kinds of soil such as pick work jumper work, blasting work decomposed conglomerate saturated soil soft rock and hard rock including dressing of sides and beds and preparation of sub grade to level or slope including refilling the trenches and disposing of surplus earth up to all leads lifts disposed earth to be leveled and neatly dressed including jungle clearance and as per direction of Engineer in charge.
Laying & Jointing of GMS pipes of various dia in trenches (earth work in trenches to be measured and paid for separately) including all leads lifts and carriage of material at site as per direction of Engineer in charge.
15 mm dia
20 mm dia
25 mm dia
32mm dia
40 mm dia
50mm dia
65mm dia
Manufecturing and supply of GI pipe manifold distributor vertical with 65mm dia (G.I. pipe will be issued by the department free of cost) by cutting and welding the distributor shall be 50cm long having 4 Nos 15cm dia connection at the top with 107 long nipple of 15mm dia GI pipe both side (G.I. pipe will be supplied by the department free of cost) & providing elbow 15mm dia and 25 mm dia to 32mm dia bottom inlet by properly pluging at the top with GI socket adn with MS sheet 3.15mm thick at the bottom as per the direction of the engineer in charge at the site of work.
Providing and fixing GI/MS Hexagoned 15 mm dia threaded nipple with 6mm internal hole to control the water in house hold connection conmpete with all leads and lift as per direction of Engineer in charge.
Providing and Fixing MS Bib tap
SURENDAR HANSRETTA
Dogra Construction Company Pvt Ltd
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .