Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.3 LAccepted-AOC 46 S P MUKHERJEE ROAD KOLKATA 700026 | KOLKATA | KOLKATA | WEST BENGAL | 700026 | ₹24.3 L | L1 | Accepted-AOC AOC |
| 2 | L2₹25.1 L+₹78,803 (3.24%)Rejected-Finance | ₹25.1 L+₹78,803 (3.24%) | L2 | Rejected-Finance Being L2 Bidder |
| 3 | L3₹26.1 L+₹1.8 L (7.34%)Rejected-Finance 230 S N ROY ROAD SAHAPUR COLONY KOLKATA WEST BENGAL 700038 | KOLKATA | WEST BENGAL | 700038 | ₹26.1 L+₹1.8 L (7.34%) | L3 | Rejected-Finance Being L3 Bidder |
| 4 | L4₹27.9 L+₹3.6 L (15.0%)Rejected-Finance VILL CHHOTO CHAND GHAR PO BARA CHAND GHAR DIST NADIA PIN 741196 | 741196 | ₹27.9 L+₹3.6 L (15.0%) | L4 | Rejected-Finance Being L4 Bidder |
| 5 | L5₹29.3 L+₹5.1 L (20.8%)Rejected-Finance | ₹29.3 L+₹5.1 L (20.8%) | L5 | Rejected-Finance Being L5 Bidder |
| Sl No | Description | Qty | Unit | switching avo Electro Power Ltd L3 | ASCO L6 | GHANASHYAM ELECTRIC STORES L9 | THE INDIAN OVERSEAS TRADING COMPANY L8 | ATREYA INDUSTRIAL POWER SOLUTIONS LLP L5 | ASIM KRISHNA MODAK L4 | Dcon Enterprise L2 | UNITED CONSTRUCTION SERVICE L7 | C. CHOWDHURY & CO. L1 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | SITC of 30 KVA UPS including Battery Bank of 24960 VAH or higher (SMF Battery) 12 Volt 3ph Input / 3ph Output, inbuilt/External Isolation Transformer, static by pass arrangement, compitable with D.G. Set, DSP controlled IGBT based rectifire with minimum 90% efficincy on 100% Load. The UPS shall be provided with active input P.F. Correction system to obtain 0.9 lag at 1.00% resistive Load, Wave form Pure line wave. It Should be capable of operating in 50'c above ambient temprature, Built in Solid State float cum boost charger with automatic boost / trickel charge mode with current Limiting features. The charger should be designed for at least 15% of the total battery current. The UPS Should have current limiting protection, built in over load / Short circuit protection with snubber circuits for current limit. Soft start arrangement, Over voltage / under voltage protection, mains ON, Inverter ON/ OFF/ FAULTY/ TRIP (Reason), Charger ON/ FAULTY or TRIP, Battery Low, Static by-pass ON, Over temperature. Battery set Complete with self-standing cubicle or cabinet. The UPS should have external automatic load transfer switch for parallel operation.
Regulated Sealed Lead Acid Battery, Construction type
: AGM or VRSLAB in ABS Flame Retardant Rating, (12V, 65 AH SMF Battery -1 Lot) (Battery Make Amararaja Quntra/Exide Power Safe). Back up time 30 Min at full load. Warranty: One Year on UPS and two Years on SMF Battery on site against any manufacturing defects. Certificate : ISO 9001:2015, ISO 14001:2015, IOS 18001, OHSAS 18001. CE Certification: IEC/EN 62040-1-1, IEC/ EN50091-1,IEC/EN 60950(Safety), IEC/EN 5009 1-2, IEC/EN 62040-2(EMC Emmission), IEC/EN 62040-3 (Performance & Design), IEC/EN 61000 4(EMC Emmunity) & IEC/EN 60146 (Design & Manufacture) (Make: APC- Schneider Electric / NUMERIC/ Powersafe/ Delta/ Power One/ VERTIV/ Switching AVO) | 3 | Job | 6,06,330 ₹18,18,990 | 7,56,900 ₹22,70,700 | 7,75,000 ₹23,25,000 | 7,00,000 ₹21,00,000 | 7,12,439.91 ₹21,37,319.73 | 6,63,000 ₹19,89,000 | 5,34,968 ₹16,04,904 Lowest | 6,90,000 ₹20,70,000 | 5,75,000 ₹17,25,000 |
| 1.01Terms and condition: 1. The Agency must procure the materials from the Manufacturer / OEM or from their authorised sales channel so that the standard warranty / support of the Manufacturer / OEM becomes applicable to the products to be delivered and installed by them. 2.Documents that authenticates such procurement from the Manufacturer / OEM or from their authorized sales channel and standard warranty / support should be sent from the e-mail of the Manufacturer / OEM / authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution, of work/submission of bill. 3. If any refurbished material is supplied and installed, penal action will be taken as per existing rules Agency should have a permanent Office/service centre at Kolkata, West Bengal, Authentic in support of the same should be uploaded alomgwith GSTIN no. During DLP any breakdown call must be attended with in 24 hrs without any delay | ||||||||||||
| 2.00 | Dismantaling all the UPS System along with damaged batteries and submit all the material to office / authority.(As per direction of EIC) (NS) | 1 | Job | 20,000 ₹20,000 | 8,000 ₹8,000 | 25,000 ₹25,000 | 25,000 ₹25,000 | 2,770.86 ₹2,770.86 | 4,000 ₹4,000 | 5,000 ₹5,000 | 25,000 ₹25,000 | 1,000 ₹1,000 Lowest |
| 3.00 | Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 25mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required(for three phase industrial plug)
i)4 x 56/0.3 (4 sqmm) + 2 x 36/0.3 (2.5 sqmm) ECC [E-14/b(V)] | 120 | mtr | 420 ₹50,400 | 296 ₹35,520 | 650 ₹78,000 | 409 ₹49,080 | 289.95 ₹34,793.52 | 220 ₹26,400 | 350 ₹42,000 | 450 ₹54,000 | 100 ₹12,000 Lowest |
| 3.01 | ii)4x80/0.4 (10 sqmm) + 2x84/0.3 (6 sqmm) as ECC [E9/1d1+E16/7b] | 60 | mtr | 1,000 ₹60,000 | 575 ₹34,500 | 550 ₹33,000 | 780 ₹46,800 | 822.95 ₹49,376.76 | 850 ₹51,000 | 820 ₹49,200 | 1,140 ₹68,400 | 400 ₹24,000 Lowest |
| 4.00 | Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
4 sqmm | 10 | set | 44 ₹440 | 6 ₹60 Lowest | 10 ₹100 | 48 ₹480 | 484.9 ₹4,849.01 | 30 ₹300 | 50 ₹500 | 50 ₹500 | 10 ₹100 |
| 4.01 | 10 sqmm | 6 | set | 64 ₹384 | 8 ₹48 Lowest | 10 ₹60 | 92 ₹552 | 761.99 ₹4,571.92 | 70 ₹420 | 75 ₹450 | 70 ₹420 | 10 ₹60 |
| 5.00 | Supply and installation of 12 Volt 42 AH VRLA Battery of Lead Acid, Sealed Maintenance Free (SMF) and conforming to relevant IS Specification with Low/High Battery Voltage and Weak Battery warning. [Make- Exide, Model- EP42-12 or equivalent model of Amaron / Luminous] as per GS. ( 64 no for 20KVA +16 no for 5KVA) including buy back option. | 80 | Nos | 3,775 ₹3,02,000 | 3,745 ₹2,99,600 Lowest | 5,500 ₹4,40,000 | 5,028 ₹4,02,240 | 4,641.2 ₹3,71,295.6 | 4,150 ₹3,32,000 | 4,800 ₹3,84,000 | 5,250 ₹4,20,000 | 4,600 ₹3,68,000 |
| 6.00 | Supply and installation of 12 Volt 100 AH VRLA Battery of Lead Acid, Sealed Maintenance Free (SMF) and conforming to relevant IS Specification with Low/High Battery Voltage and Weak Battery warning. [Make- Exide, Model- EP100-12 or equivalent model of Amaron / Luminous] as per GS. including buy back option. | 32 | Nos | 7,863 ₹2,51,616 | 7,880 ₹2,52,160 | 7,500 ₹2,40,000 | 10,612 ₹3,39,584 | 7,446 ₹2,38,272 Lowest | 9,500 ₹3,04,000 | 10,450 ₹3,34,400 | 8,500 ₹2,72,000 | 8,250 ₹2,64,000 |
| 7.00 | Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 25mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required(for three phase industrial plug input output connection)
i)4 x 56/0.3 (4 sqmm) + 2 x 36/0.3 (2.5 sqmm) ECC ( E-14) | 100 | mtr | 420 ₹42,000 | 296 ₹29,600 | 100 ₹10,000 Lowest | 409 ₹40,900 | 214.2 ₹21,420 | 320 ₹32,000 | 340 ₹34,000 | 450 ₹45,000 | 100 ₹10,000 Lowest |
Tender Value
Refer Docs
EMD Value
₹60,715
Closing Date
8 Jul 2025, 2:00 pmClosed
Office of the Exe Engr, North 24 pgs EL DIV, PWD,
OFFICE OF THE EXECUTIVE ENGINEER NORTH 24 PARGANAS ELECTRICAL DIVISION, TOP FLOOR, MECHANICAL COMPLEX,BAGUIATI, KOLKATA 700 059
SITC of UPS system for SNCU OT ANW and Battery replacement of UPS for SNCU OT and Antenatal ward for emergency back up power And replacement of old batteries for the UPS installed at CCU and USG department of Basirhat DH, Basirhat HD.
2025_WBPWD_865595_1
WBPWD/EE/N24/EL/e-NIQ-19/25-26
Open Tender
MISC ELECTRICAL WORKS
Item Rate
45 days
Basirhat District Hospital
Please refer Tender documents.
4 documents required · 4 mandatory
₹60,715
Office of the Exe Engr, North 24 pgs EL DIV, PWD
16 Sept 2026
17 Jun 2025
10 Jul 2025
17 Jun 2025
8 Jul 2025
24 Jun 2025
23 Jun 2025
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .