Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 10 A SAURASTRA PATEL SOCIETY YAGNIK HALL NR BHIDBHANJAN BAPUNAGAR AHMEDABAD 380024 | AHMADABAD | GUJARAT | 380024 | Admitted-Finance |
Tender Value
₹2.4 L
EMD Value
₹4,757
Closing Date
22 Jan 2022, 2:00 pmClosed
The Executive Engineer (Electrical)
O/o the Executive Engineer (E), BSNL Electrical Division, D/1 staff quarter, Lohanagar, Bhaktinagar Telephone Exchange Building. Rajkot
Replacement of Damaged Light, Fan, Fire Detectors, Split AC and other associated work Damaged Due to Fire Incident at NFS Bldg. Package -I SAMANA, Dist-Jamnagar...... 3rd Call
2022_BSNL_101657_1
27/EEE (R )/BSNL ED/2021-22
Open Tender
Electrical Works
Item Rate
60 days
Samana
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
AO (Cash) BSNL, GMTD, Rajkot
₹4,757
24 Jan 2022
13 Jan 2022
24 Jan 2022
13 Jan 2022
22 Jan 2022
13 Jan 2022
Amount
SITC of complete indoor unit, coil tubes shall be made from copper, with remote control suitable Voltas make, model-CU183EZA (or indoor unit SS make/model maching with existing outdoor unit; approved by BSNL) outdoor unit of BEE 3 star rated 1.5 TR inverter type split AC unit having nominal cooling capacity of 4500 Kcal/hr etc., pumpdown of refrigerent gas from existing unit, complete as per specifications, etc as required.
Supplyg and Fixing additional suction and discharge gas copper piping suitable for existing SAC units, breasing/ jointing suitable for above AC units, where ever required includiging expanded nitrate foam (heat lon type class 'O') insulation for suction & discharge gas piping etc as required.
Supplying and charging of refrigerent gas suitable for existing AC units for topping up into existing AC etc as reqd.
Repairing of existing 2' x 2' size LED based recess mounted type of light fixture (luminaire) i/c removing from celing, complete opening of front cover, cleaning/removing all Smoke/dirt particles accumulated/coated from all entire parts and fitting with suitable cleaning agents, replacement of damaged LED lamp and all other damaged parts, painting with approved colour, reassembling the fitting and installation, testing and comissioning of same after repairing in ceilling etc as reqd.
Supplying and fixing of 600 mm X 600 mm size LED based recess mounted type of light fixture (luminaire) with diffusers , 30 watts-36 watts rating, suitable for operation on 230 voltls AC supply, including fixing the fixture on false ceiling with chain supports, GI flexible conduits with coupler for connections, testing etc complete as reqd.(For Equipment room) (Model:- Same to Existing Model provided for the site/available at site and approved by BSNL)
Addressable Multisensor Detector: Supply, Installation, Testing and Commissioning of Addressable analogue MULTISENSOR / MULTICRITERIA type, UL Listed photo cum thermal detectors with solid state design, indicating LED, mounting base, mounting bracket etc. base box, loop in & loop out gland as per requirement and detailed specification as per following positions.
a) On Real Ceiling (Base Box is to be Used)
b) On False Ceiling
c) On False Flooring including S/F of MS tripod made of 20 mm x 3 mm flat and MS sheet box of suitable size to accommodate 1 no addressable multisensor detector.
Removing of existing all type addressable analogue MULTISENSOR / MULTICRITERIA type, UL Listed photo cum thermal detectors from trypot/ceiling/false ceiling, complete opening of detector, cleaning of inner side of detector with suitable cleaning agents, removing of smoke/dist, reassembling of same, installation on same location, testing and commissioning the same etc as reqd.
Addressable control modules: Supply Installation Testing and Commissioning of UL Listed, Addressable control module complete with junction box etc. for control options for Hooters & for other control options like PA evacuation, Access Doors opening, Package AC trip etc. in case of emergency, as required.
Addressable monitoring modules: Supply Installation Testing and Commissioning of UL Listed Addressable monitoring modules complete with junction box etc. to monitor status of other systems etc. as required.
Removing of existing all type manual call point, opening, cleaning of inner side of, removing of smoke/dist particles accumulated/coated, cleaning with suitable cleaning agents, reassembling of same, installation on same location, testing and commissioning the same etc as reqd.
Manual Call Point: Supply Installation Testing and Commissioning of UL Listed Manual call points with NO/NC contacts slim type with Pull type/break glass with Reset Lock & Key arrangement suitable for addressable function
Electronic Hooter Cum Strobe: Supply Installation Testing and Commissioning of Hooter having three distinct sounds with addressable relay module and strobe light with minimum 85 db from 1Mtr distance etc. as required.
Removing of existing all type hooters, opening, cleaning of inner side of, removing of smoke/dist particles accumulated/coated, cleaning with cleaning agents, reassembling of same, installation on same location, testing and commissioning the same etc as reqd.
Removing of existing all type Response Indicators from Ceiling/wall, opening, cleaning of inner side of, removing of smoke/dist particles accumulated/coated, cleaning with suitable cleaning agents; reassembling of same, installation on same location, testing and commissioning the same etc as reqd.
Supply Installation Testing and Commissioning of Response indicator having twin LEDs for mounting on false ceiling / wall at the entries of the cabin for indicating the operation of detectors in the above false ceiling / below false flooring detectors etc. as required.
Supplying and fixing 450 MM Sweep, 1200RPM, 75 CMM air delivery, 60 Watt, wall mounting type Air circulator Fan etc as reqd.
Cleaning of Smoke/dirt particles accumulated/coated on Indoor unit of 7 TR High Precision Package AC units; complete outside and inside of unit by opening/removing all compartment/parts; cleaning with Air /Water/suitable cleaning agents etc as reqd.
Supplying & drawing of the following FRLS PVC insulated copper conductor single core cable in the existing surface / recessed steel / PVC conduit as required.
a) 1X1.5 Sq mm
b) 2X1.5 Sq mm
c) 3 X 1.5 Sq mm
d) 4 X 1.5 Sq mm
e) 6 x 1.5 Sq mm
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.
a)2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
b)4 X 1.5 sq. mm + 2 X 1.5 sq. mm earth wire
c) 6 X 1.5 sq. mm + 3 X 1.5 sq. mm earth wire
d)2 X 4 sq. mm + 1 X 4 sq. mm earth wire
e)4 X 4 sq. mm + 2 X 4 sq. mm earth wire
f)2 X 6 sq. mm + 1 X 6 sq. mm earth wire
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .