Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance XXIV 307 5 SECOND FLOOR SOORAJ APPRATMENT NEAR REVENUE TOWER THIRUVALLA | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹2.9 Cr
EMD Value
₹1 L
Closing Date
25 Aug 2025, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer
Office of The Superintending Engineer PH Circle, Painavu, Idukki - 685603
Package V-Supply, erection, testing and commissioning of Raw water pump set, Clear water pump sets, Supply and installation of flow meters, Electrical and allied worksGeneral Civil Work
2025_KWA_724795_2
30/2024-25/SE/PHC/IDK/6970
Open Tender
Civil Works - Water Works
Item Rate
Idukki
As per NIT
3 documents required · 3 mandatory
₹8,270
₹1 L
Yes
27 Aug 2025
2 Jun 2025
27 Aug 2025
2 Jun 2025
25 Aug 2025
2 Jun 2025
Amount
Supply and installation of flow meters at WTP compound
OD254483/2022-2023:Supplying 350mm electro- magnetic flow meter conforming to protection level of IP- 68 for Flow Sensor and IP-67 for transmitter and having an accuracy level of 0.5% with LED/LCD display unit. The flow meter should have the housing(flow sensor) to be made of SS 304 Carbon Steel with anti corrosive protection and inside liner to be made up of Hard Rubber/Neoprene all conforming to drinking water standards. The flow meter should be coupled with HART for data acquisition and transfer with provision for wireless transfer through GSM. The manufacture should have the calibration standards as per ISO 17023 and the product shall have sufficient warranty provisions.
OD254489/2022-2023:Labour for cutting DI pipes 350mm Dia
OD254492/2022-2023:Fabricating and fixing 350 mm MS flange
OD254493/2022-2023:conveying and fixing 350 mm mechanical flow meter
OD254495/2022-2023:Supplying 250mm electro- magnetic flow meter conforming to protection level of IP- 68 for Flow Sensor and IP-67 for transmitter and having an accuracy level of 0.5% with LED/LCD display unit. The flow meter should have the housing(flow sensor) to be made of SS 304 Carbon Steel with anti corrosive protection and inside liner to be made up of Hard Rubber/Neoprene all conforming to drinking water standards. The flow meter should be coupled with HART for data acquisition and transfer with provision for wireless transfer through GSM. The manufacture should have the calibration standards as per ISO 17023 and the product shall have sufficient warranty provisions
OD254516/2022-2023:Labour for cutting DI pipes 250mm Dia
OD254504/2022-2023:Fabricating and fixing 250 mm MS flange
OD254508/2022-2023:conveying and fixing 250 mm mechanical flow meter
OD254521/2022-2023:Supplying a mechanical flow meter of WOLTMAN type confirming to ISO 4064 class B of ARAD/ZENNER/REYCHEM RPG/ITRON make and the flowmeter shall be tested and certified by FCRI - Palakkad. Flow meter should be calibrated with physical measurement at site after installation. : 200 mm diameter
OD254524/2022-2023:Labour for cutting DI pipes 200mm Dia
OD254510/2022-2023:Fabricating and fixing 200 mm MS flange
OD254511/2022-2023:conveying and fixing 200 mm mechanical flow meter
OD254531/2022-2023:Supplying and fixing mechanical flow meter of WOLTMAN type confirming to ISO 4064 class B of ARAD/ZENNER/REYCHEM RPG/ITRON make and the flowmeter shall be tested and certified by FCRI - Palakkad. Flow meter should be calibrated with physical measurement at site after installation. : 150 mm diameter
OD254533/2022-2023:Labour for cutting DI pipes 150mm Dia
OD254534/2022-2023:Fabricating and fixing 150 mm MS flange
Electrical and allied works
OD112108/2023-2024:Supply of all materials and providing 11KV Double pole structure using 2nos. 175x85mm. ISMB joist of 9.5M height, 100x50mm. GI chanel cross arms, 1set 3 pole of 400A, 11KV gang operated AB switch with operating handles of required length,1 set of 9.6KV,6KA Lightning Arrestors, 1 sets (3 nos) of 11KV, D.O fuses, Pin insulators, Disc insulators and inter connections of the above items using 8mm dia copper wire with proper copper sockets , including all associated civil works and painting of all structurers with two coats of zinchromate primer and aluminium paint etc. and earthing using 5 nos of 3m GI earthing pipes and inter connection complete as per standard construction practices approved by Kerala Electrical Inspectorate and relevant standards
OD254553/2022-2023:OUTDOOR HT BREAKER PANEL (LBS) Supply, Installation, Testing & Commissioning of 11kV Outdoor HT Breaker Panel with the following components. 11kV Load Break Swich 11kV, 350 MVA, 630A, LBS unit - 1 set Voltmeter ( 0 - 11kV) - 3 Nos LED Pilot Indication - LBS ON / OFF - 1 Set Trip Push buttons - 1 set 2NO+2NC Aux contacts - 1 Set 230V AC Shunt Trip Coil - 1 No Aluminium Busbar - 1 Set Seal off Bushings - 3 Nos Space Heater Element with Thermostat & wiring - 1 Nos Inspection Lamp LED with switch & wiring - 1 set Metering Chamber PT - 100 VA, 11kV/110V, CL 0.2S - 1 No CT - */5A, 15VA, CL 0.2S - 3 Nos Provisions for mounting 3 phase, 4wire, HT CT/PT operated, bi-directional TOD meter with accuracy class 0.2S including wiring and test terminal block, site glass etc. - 1 set "Voltage Circuit: The active & apparent power consumption of voltage circuit including power supply of meter at reference voltage, reference temperature & frequency shall not exceed 1.0 Watt & 4.0 VA per phase " Current Circuit: The apparent power taken by current circuit at basic current, reference frequency & reference temperature shall not exceed 1.0 VA/phase. ( The Quoted rate shall be inclusive of necessary control wiring, components working on LT supply should be prewired completely with necessary controls as specified till the connection point for feeding LT Supply from outside, Cable end box for receiving incoming and outgoing cables and suitable civil foundation etc as required.)
OD254554/2022-2023:HT Bidirectional TOD Meter Supply & Providing 3 phase, 4wire, HT CT/PT operated, bi-directional with accuracy class 0.2S for both Active and Reactive energy, -/5A, HT static tri vector meter with TOD register, DLMS compliant & AMR compatible with optical port and RS232 port having ISI Marking, suitable for measurement of active kWh, reactive energy kVARh and apparent energy kVAh and kVA MD, kW MD at nominal frequency in the range of 47.5 Hz to 52.5 Hz in balanced as well as unbalanced load conditions in the existing outdoor Meter cubicle including testing & commissioning etc. complete.
OD254555/2022-2023: HT Equipment Pinth, Substation Yard Fencing & Levelling Providing, fabricating and fixing 2m high chainlink fencing over 4mm thick barbed wire with a framework of 50x50x6mm MS angle between vertical posts of ISMC 75 at 2400mm interval, Earthing as per KSEI/KSEB standards shall be done around the periphery of the fencing. The MS framework for chainlink fencing shall be Hot Dip Galvanised. The rate shall be inclusive of all materials, labour, lead, lift etc including escalation works and fabrication and assembly works including all nuts, bolts and other miscallaneous items etc complete as per drawing and as directed by the Engineer in Charge.
OD254558/2022-2023: HT Equipment Pinth, Substation Yard Fencing & Levelling Supplying and filling the substation yard with 40mm size blue jelly of 150mm thick including cost and conveyance of all materials, labour charges etc complete
OD254560/2022-2023: HT Equipment Pinth, Substation Yard Fencing & Levelling Supply & erection of Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand).
OD254561/2022-2023:Transformer Supply, installation, testing and commissioning of one number 500 kVA, DYn11, 3Ph, 50Hz, 11/0.433 kV,ONAN cooled, copper wound outdoor distribution transformer with tappings from +5% to -10% in steps of 2.5% with OFTC. The HT side & LT side shall have cable end box for XLPE cable. The transformer shall have suitable enclosure for The HT side & LT side. The transformer shall be complete with all standard accessories and fittings & conform to IS:2026. The rate shall be inclusive of all materials, lead,lift, first fill of oil, necessary civil works for mounting to the existing transformer foundation complete as per single line schematic diagram & particular specifications.
OD254562/2022-2023:NEUTRAL CT Supply & Providing 5P10 Protection Class 150/5A, 15VA Neutral CT in a suitable enclosure including giving connections to Transformer Neutral etc.complete
OD254563/2022-2023:MSB for 500KVA Transformer Supply, fabrication, erection, testing and commissioning of cubicle type fully compartmentalised, dust tight, vermin proof, water proof 800A LT- Main MV Panel falling to IP54 category fabricated out of 16 SWG CRCA Sheet Steel painted as per standards with Aluminium Busbars of suitable size, earth bus of adequate capacity, double earth connection to all switches, internal rigid connection etc. including suitable chambers, front open, top cable entry with water proof shrouding, free standing panel consisting of the following as per standards ( All switches shall confirm to conforming to IEC 60947-2 standards). Incommer 800A FP Microprocessor based MCCB (36kA) - 1 Nos. Earth Fault Relay - 1 Set 800A TPN best conductivity Aluminium busbar with SMC supports, heat shrinkable sleeves etc. as per ISS - 1set RYB indicators ( LED Pilot type ) with 2A Control MCB and toggle switches - 4 Set Multifunction Digital Panel meter to read V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh Class 1.0 - 1 Set 800/5A CL 1.0, 15VA Metering CTs - 1 Set Outgoing : 250A FP Microprocessor based MCCB (36kA) – 4Nos 125A FP Microprocessor based MCCB (36kA) – 4Nos "Surge Protection Pluggable type surge arrester with potential free contact, thermal disconnector & provision for inbuilt common remote indication for defective arresters to connect between Line and Neutral and one number Spark Gap type arrester to connect between Neutral and Earth of following ratings including base element & pluggable arresters. Nominal voltage 230V, 50Hz, Nominal Discharge current 30 kA (8/20 sec) for Line to Neutral & 50 kA (8/20 sec) for Neutral to Earth, Maximum Discharge Current Imax 50 kA (8/20 sec) -1Set" Supports The panel shall be supported to ground using framework fabricated out of MS Flats / Angles etc. painted with two coats of Zinc Chromate primer and two coats of enamel paint. The framework shall be firmly supported to ground using suitable cement concrete plinth. The Panel Board shall be provided with 25 x 3mm copper earth bus for the full length. Painting letters / identifications for the incoming and outgoing switches, cable, fuse sizes, etc., in white enamel paint. The board shall be fabricated in such a way that future extenstion be possible.
OD254564/2022-2023:SSB Supply, fabrication, erection, testing and commissioning of cubicle type fully compartmentalised, dust tight, vermin proof, water proof 200A MV Panel falling to IP54 category fabricated out of 16 SWG CRCA Sheet Steel painted as per standards with Alumimium Busbars of suitable size, earth bus of adequate capacity, double earth connection to all switches, internal rigid connection etc. including suitable chambers, front open, top cable entry with water proof shrouding, free standing panel consisting of the following as per standards ( All switches shall confirm to conforming to IEC 60947-2 standards). Incoming : 250A(36KA) MCCB FP Micro processor based, TPN best conductivity Aluminium busbar with SMC supports, heat shrinkable sleeves etc. as per ISS - 1set Multifunction Digital Panel meter to read V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh Class 1.0 - 1 Set RYB indicators ( LED Pilot type ) with 2A Control MCB and toggle switches - 1 Set 100/5A CL 1.0, 15VA Metering CTs - 1 Set Outgoings: 250A, 36kA FP MP MCCB - 4 Nos. 160A, 36kA FP MP MCCB - 4 Nos. 20A TP D curve MCB (10kA) - 4 Nos. Supports The panel shall be supported to ground using framework fabricated out of MS Flats / Angles etc. painted with two coats of Zinc Chromate primer and two coats of enamel paint. The framework shall be firmly supported to ground using suitable cement concrete plinth. The Panel Board shall be provided with 25 x 3mm copper earth bus for the full length. Painting letters / identifications for the incoming and outgoing switches, cable, fuse sizes, etc., in white enamel paint. The board shall be fabricated in such a way that future extenstion be possible.
OD254565/2022-2023:APFC PANEL Automatic Power Factor Correction Panel of total 85 KVAR capacity with Auto / Mannual mode operation to be fabricated out of 14 guage CRCA sheet steel Powder coated with provision for capacitor mounted inside the panel with adequate number of louvers and powder coated with approved shade and having following specific components(refer particular specification) with Alumimium Busbars of suitable size, earth bus of adequate capacity, double earth connection to all switches, internal rigid connection etc. including suitable chambers, front open, top cable entry , free standing panel consisting of the following as per standards. Incomer 200A TPN Isolator - 1 No. 200 A TPN best conductivity Aluminium busbar with SMC supports, heat shrinkable sleeves etc. as per ISS - 1set Multifunction Digital Panel meter to read V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh Class 1.0 - 1 Set RYB indicators ( LED Pilot type ) with 2A Control MCB and toggle switches- 1 Set 200/5A 15VA CL 1.0 Metering CTs - 3 Sets Microprocessor based intelligent, 8 step IPFC relay with PF display - 1 No. Out goings 63A, 10kA C Curve TP MCB - 1 Nos 16A, 10kA C Curve TP MCB - 6 Nos Capacitor duty contactors working on 3 Phase 415V AC supply of the following ratings wired with Pilot LED indication for ON & OFF, Push Buttons for Manual ON & OFF operation using suitable NO / NC contacts for all the stages 25 kVAr- 1 Nos 10 kVAr- 6 Nos 480 V,50 Hz Double di-electric polypropylene ( MPP heavy duty ) Capacitors of the following ratings including fixed compensation for low load losses. 25 kVAr- 1 Nos 10 kVAr- 6 Nos Supports The panel shall be supported to ground using framework fabricated out of MS Flats / Angles etc. painted with two coats of Zinc Chromate primer and two coats of enamel paint. The framework shall be firmly supported to ground using suitable cement concrete plinth. The Panel Board shall be provided with 25 x 3mm copper earth bus for the full length. Painting letters / identifications for the incoming and outgoing switches, cable, fuse sizes, etc., in white enamel paint.
OD254566/2022-2023:Supply, installation, testing & commissioning of best quality sheet steel, phosphatised and painted, dust and vermin proof enclosure (IP43) Vertical TPN Double door DB including copper bus bar, neutral link, earth bus and DIN rail suitable for fixing RCCB + Isolator (8 module )as incommer and SP/TP MCB as outgoings etc. on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing, dressing the DB including termination etc. as required. ( Including closing vaccant slots using Dummy )
OD254568/2022-2023:Supply and providing the following MCCB/ RCCB / MCB / MCB Isolators/COS etc. to the existing DBs / MCS / Junction Boxes etc. including giving proper termination using suitable Bananna copper lugs, sleeves, insulation etc. complete. 63A, 100mA 3Ph RCCB
OD254572/2022-2023:Supply and providing the following MCCB/ RCCB / MCB / MCB Isolators/COS etc. to the existing DBs / MCS / Junction Boxes etc. including giving proper termination using suitable Bananna copper lugs, sleeves, insulation etc. complete. 63A, 4P MCB Isolator
OD254573/2022-2023:Supply and providing the following MCCB/ RCCB / MCB / MCB Isolators/COS etc. to the existing DBs / MCS / Junction Boxes etc. including giving proper termination using suitable Bananna copper lugs, sleeves, insulation etc. complete. 6A to 32A , 10kA SP MCB
OD254574/2022-2023:HT Power Cables "Supply & laying 11KV stranded compact circular aluminium conductor, conductors screened with extruded semi conducting compound XLPE insulated, insulation screened with extruded semi conducting compound in combination with copper tape (0.3 kA for 1 sec.), cores laid up, inner sheath of PVC tape, galvanized steel flat strip armoured, and overall PVC sheathed cable of the following sizes in the existing cable trench conforming to IS: 7098 part II 1985 with latest amendments." 3C x 300 Sqm
OD254575/2022-2023:"Supply & laying 11KV stranded compact circular aluminium conductor, conductors screened with extruded semi conducting compound XLPE insulated, insulation screened with extruded semi conducting compound in combination with copper tape (0.3 kA for 1 sec.), cores laid up, inner sheath of PVC tape, galvanized steel flat strip armoured, and overall PVC sheathed cable of the following sizes in the existing cable trench conforming to IS: 7098 part II 1985 with latest amendments." 3C x 150 Sqm
OD254578/2022-2023:HT Cable Terminations "Supplying and making Outdoor cable end jointing with heat shrinkable jointing kit, including lugs and other jointing materials, for for following sizes, XLPE aluminium conductor cable of 11 KV grade as required." 3C x 150 Sqmm
OD254586/2022-2023:HT Cable Terminations "Supplying and making Outdoor cable end jointing with heat shrinkable jointing kit, including lugs and other jointing materials, for for following sizes, XLPE aluminium conductor cable of 11 KV grade as required." 3C x 300 Sqmm
OD254590/2022-2023:LT Power Cables Supply & laying UG A2XFY,PVC insulated and PVC sheathed Aluminium conductor armoured power cable of 1.1 KV grade of following sizes through trench/wall/ ceiling. 4C x 400 Sqmm
OD254591/2022-2023:LT Power Cables Supply & laying UG A2XFY,PVC insulated and PVC sheathed Aluminium conductor armoured power cable of 1.1 KV grade of following sizes through trench/wall/ ceiling. 3.5C x 185 Sqmm
OD254592/2022-2023:LT Power Cables Supply & laying UG A2XFY,PVC insulated and PVC sheathed Aluminium conductor armoured power cable of 1.1 KV grade of following sizes through trench/wall/ ceiling. 3.5C x 50 Sqmm
OD254599/2022-2023:LT Power Cables Supply & laying UG A2XFY,PVC insulated and PVC sheathed Aluminium conductor armoured power cable of 1.1 KV grade of following sizes through trench/wall/ ceiling. 3.5C x 35 Sqmm
OD254594/2022-2023:LT Power Cables Supply & laying UG A2XFY,PVC insulated and PVC sheathed Aluminium conductor armoured power cable of 1.1 KV grade of following sizes through trench/wall/ ceiling. 4C x 16 Sqmm
OD254595/2022-2023:LT Power Cables Supply & laying UG A2XFY,PVC insulated and PVC sheathed Aluminium conductor armoured power cable of 1.1 KV grade of following sizes through trench/wall/ ceiling. 4C x 6 Sqmm
OD254597/2022-2023:LT Power Cables Supply & laying UG A2XFY,PVC insulated and PVC sheathed Aluminium conductor armoured power cable of 1.1 KV grade of following sizes through trench/wall/ ceiling. 4C x 4 Sqmm
OD254593/2022-2023:LT Power Cables Supply & laying UG A2XFY,PVC insulated and PVC sheathed Aluminium conductor armoured power cable of 1.1 KV grade of following sizes through trench/wall/ ceiling. 3C x 35 Sqmm
OD254605/2022-2023:LT Power Cables Supply & laying UG A2XFY,PVC insulated and PVC sheathed Aluminium conductor armoured power cable of 1.1 KV grade of following sizes through trench/wall/ ceiling. 3C x 25 Sqmm
OD254606/2022-2023:LT Power Cables Supply & laying UG A2XFY,PVC insulated and PVC sheathed Aluminium conductor armoured power cable of 1.1 KV grade of following sizes through trench/wall/ ceiling. 3C x 16 Sqmm
OD254607/2022-2023:LT Power Cables Supply & laying UG A2XFY,PVC insulated and PVC sheathed Aluminium conductor armoured power cable of 1.1 KV grade of following sizes through trench/wall/ ceiling. 3C x 6 Sqmm
OD254608/2022-2023:LT Power Cables Supply & laying UG A2XFY,PVC insulated and PVC sheathed Aluminium conductor armoured power cable of 1.1 KV grade of following sizes through trench/wall/ ceiling. 3C x 4 Sqmm
OD254609/2022-2023:Supply & laying UG 2XFY,PVC insulated and PVC sheathed Copper conductor armoured Power / Control cable of 1.1 KV grade of the following sizes through trench/wall/ ceiling 4C x 2.5 Sqmm
OD254611/2022-2023:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3.5C x 185 Sqmm
OD254612/2022-2023:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3.5C x 50 Sqmm
OD254613/2022-2023:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3.5C x 35 Sqmm
OD254614/2022-2023:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4C x 16 Sqmm
OD254615/2022-2023:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4C x 6 Sqmm
OD254616/2022-2023:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4C x 4 Sqmm
OD254619/2022-2023:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3C x 35 Sqmm
OD254620/2022-2023:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3C x 25 Sqmm
OD254621/2022-2023:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3C x 16 Sqmm
OD254622/2022-2023:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3C x 6 Sqmm
OD254623/2022-2023:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3C x 4 Sqmm
OD254624/2022-2023:Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE copperconductor cable of 1.1 KV grade as required. 4C x 2.5 Sqmm
OD254630/2022-2023:Supply & drawing the following size of FR Multi-core PVC Insulated and PVC sheathed Copper conductor round flexible wire manufactured with bright annealed bare copper conductor as per IS 8130/1984 Insulated and sheathed with electrical grade PVC compound as per IS 5831/1984 generally conforming to IS 694/1990 for working voltage up to and including 1100 V through existing PVC conduit / casing capping wall. 3C x 0.5 Sqmm
OD254632/2022-2023:Supply & drawing the following size of FR Multi-core PVC Insulated and PVC sheathed Copper conductor round flexible wire manufactured with bright annealed bare copper conductor as per IS 8130/1984 Insulated and sheathed with electrical grade PVC compound as per IS 5831/1984 generally conforming to IS 694/1990 for working voltage up to and including 1100 V through existing PVC conduit / casing capping wall. 3C x 1.5 Sqmm
OD254633/2022-2023:Supply and providing the following size of ISI Marked rigid PVC conduits with specials confirming to IS 9537/1983 on surface / concealed position making good the damages made etc.complete. 20mm dia 1.5mm thick
OD254634/2022-2023:Supply and providing the following size of ISI Marked rigid PVC conduits with specials confirming to IS 9537/1983 on surface / concealed position making good the damages made etc.complete. 25mm dia 1.5mm thick
OD254635/2022-2023:Supply and providing the following size of ISI Marked rigid PVC conduits with specials confirming to IS 9537/1983 on surface / concealed position making good the damages made etc.complete. 32mm dia 1.5mm thick
OD254638/2022-2023:Supply & providing Capping / Casing of good quality of the following sizes. 20 mm
OD254640/2022-2023:Supply & providing Capping / Casing of good quality of the following sizes. 25 mm
OD254643/2022-2023:UG Cable Tamper Protection "Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required" 50 mm
OD254650/2022-2023:"Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required" 80 mm
OD254651/2022-2023:"Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required" 100 mm
OD254652/2022-2023:Circuit Mains Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
OD254653/2022-2023:Circuit Mains Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
OD254655/2022-2023:Circuit Mains Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
OD254656/2022-2023:Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required 150 mm width X 50 mm depth X 1.6 mm thickness
OD254657/2022-2023:Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required 300 mm width X 50 mm depth X 1.6 mm thickness
OD254658/2022-2023:Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required 600 mm width X 50 mm depth X 2 mm thickness
OD254659/2022-2023:Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 120 sq. mm and upto 400 sq. mm
OD254660/2022-2023:Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Upto 35 sq. mm
OD254661/2022-2023:Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 35 sq. mm and upto 95 sq. mm
OD254663/2022-2023:Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 95 sq. mm and upto 185 sq. mm
OD254665/2022-2023:Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle)
OD254666/2022-2023:Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
OD254667/2022-2023:Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
OD254668/2022-2023:Supply and erection of 6mm MS Chequered Plates for covering cable trench. ( Rate for 10 Sq.m)
OD254670/2022-2023:Supply route marker with 10cmx10cm GI plate 5mm thick with inscriptions there on bolted / welded to 35x35x6mm angle iron 60cm long and fixing the same in ground as required.
OD254673/2022-2023:Supply route marker with 10cmx10cm GI plate 5mm thick with inscriptions there on bolted / welded to 35x35x6mm angle iron 60cm long and fixing the same in ground as required.
OD254674/2022-2023:Earthing with 1200x1200x12.5 mm CI - Plate Earthing thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
OD254676/2022-2023:Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but with charcoal/ coke and salt ) as required.
OD254677/2022-2023:Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run) 25 x 3 mm copper strip
OD254678/2022-2023:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required 2.65 mm copper conductor (12 SWG)
OD254680/2022-2023:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required 3.15 mm copper conductor ( 10 SWG)
OD254684/2022-2023:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required 4.00 mm copper conductor ( 8 SWG)
OD254685/2022-2023:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required 4.75 mm copper conductor (6 SWG)
OD254686/2022-2023:Supply and providing 6 mm thick & 1 m wide electrical grade chequered type rubber mat to withstand 3.3 KV dielectric strength conforming to IS 5429/ 1969.
OD254688/2022-2023:Supply and providing 12 mm thick & 1 m wide electrical grade chequered type rubber mat to withstand 15 KV dielectric strength conforming to IS 5429/ 1969 in front of the HT Breaker Panel.
OD254689/2022-2023:Supply and providing 5 Kg. Dry Chemical Powder type Fire Extinguisher with hose and clamps including fixing it to wall as required.
OD254690/2022-2023:Supply and providing 9 Litre capacity GI Fire Bucket painted in post office red with primer coat of red oxide and written with white paint 'FIRE' mounted on MS angle frame work/ wall bracket filled with fine sand, painting the bracket/ floor stand including making good the damages, colour washing etc. as required.
OD254691/2022-2023:Supply and providing First Aid Chart duly framed and placed in a conspicuous location for clear vision.
OD254692/2022-2023:Supply and providing Laminated Electrical Schematic diagram framed and placed in a conspicuous location for clear vision.
OD254693/2022-2023:Supply & providing Aluminium anodised Danger Notice Board of size 200 x 150 mm. with inscriptions ( both in English and Malayalam) and conventional Skull and Bone in Red colour at locations as directed by the Engineer in Charge
OD254694/2022-2023:Preparation and submission of latest scheme drawings, Voltage drop calculations, Earthing design & fault level calculations to the Electrical Inspectorate including all MV additions recently made and obtaining approval, arranging inspection for entire installation, obtaining sanction orders for the electrical installation, complete (Including all incidental and statutory expenses ).
OD94736/2023-2024:MSB Supply, fabrication, erection, testing and commissioning of cubicle type fully compartmentalised, dust tight, vermin proof, water proof 250A LT- Main MV Panel falling to IP54 category fabricated out of 16 SWG CRCA Sheet Steel painted as per standards with Alumimium Busbars of suitable size, earth bus of adequate capacity, double earth connection to all switches, internal rigid connection etc. including suitable chambers, front open, top cable entry with water proof shrouding, free standing panel consisting of the following as per standards ( All switches shall confirm to conforming to IEC 60947-2 standards) Incommer 250A FP Microprocessor based MCCB (26kA) - 1 Nos. Restricted Earth Fault Relay - 1 Set 250A TPN best conductivity Aluminium busbar with SMC supports, heat shrinkable sleeves etc. as per ISS - 1set RYB indicators ( LED Pilot type ) with 2A Control MCB and toggle switches - 4 Set Multifunction Digital Panel meter to read V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh Class 1.0 - 1 Set 200/5A CL 1.0, 15VA Metering CTs - 1 Set Outgoings: 100A, 16kA FP MP MCCB - 4 Nos. "Surge Protection Pluggable type surge arrester with potential free contact, thermal disconnector & provision for inbuilt common remote indication for defective arresters to connect between Line and Neutral and one number Spark Gap type arrester to connect between Neutral and Earth of following ratings including base element & pluggable arresters. Nominal voltage 230V, 50Hz, Nominal Discharge current 30 kA (8/20 sec) for Line to Neutral & 50 kA (8/20 sec) for Neutral to Earth, Maximum Discharge Current Imax 50 kA (8/20 sec) -1Set" Supports The panel shall be supported to ground using framework fabricated out of MS Flats / Angles etc. painted with two coats of Zinc Chromate primer and two coats of enamel paint. The framework shall be firmly supported to ground using suitable cement concrete plinth. The Panel Board shall be provided with 25 x 3mm copper earth bus for the full length. Painting letters / identifications for the incoming and outgoing switches, cable, fuse sizes, etc., in white enamel paint. The board shall be fabricated in such a way that future extenstion be possible. Supply and installing 50 kvar APP capacitor for no load compansation
OD94737/2023-2024:SSB Supply, fabrication, erection, testing and commissioning of cubicle type fully compartmentalised, dust tight, vermin proof, water proof 200A MV Panel falling to IP54 category fabricated out of 16 SWG CRCA Sheet Steel painted as per standards with Alumimium Busbars of suitable size, earth bus of adequate capacity, double earth connection to all switches, internal rigid connection etc. including suitable chambers, front open, top cable entry with water proof shrouding, free standing panel consisting of the following as per standards ( All switches shall confirm to conforming to IEC 60947-2 standards). Incoming : 100A TPN Isolator - 1 No. 200A TPN best conductivity Aluminium busbar with SMC supports, heat shrinkable sleeves etc. as per ISS - 1set Multifunction Digital Panel meter to read V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh Class 1.0 - 1 Set RYB indicators ( LED Pilot type ) with 2A Control MCB and toggle switches - 1 Set 100/5A CL 1.0, 15VA Metering CTs - 1 Set Outgoings: 10A TP D curve MCB (10kA) - 1 Nos. Supports The panel shall be supported to ground using framework fabricated out of MS Flats / Angles etc. painted with two coats of Zinc Chromate primer and two coats of enamel paint. The framework shall be firmly supported to ground using suitable cement concrete plinth. The Panel Board shall be provided with 25 x 3mm copper earth bus for the full length. Painting letters / identifications for the incoming and outgoing switches, cable, fuse sizes, etc., in white enamel paint. The board shall be fabricated in such a way that future extenstion be possible
OD94738/2023-2024:Supply, installation, testing & commissioning of best quality sheet steel, phosphatised and painted, dust and vermin proof enclosure (IP43) Vertical TPN Double door DB including copper bus bar, neutral link, earth bus and DIN rail suitable for fixing RCCB + Isolator (8 module )as incommer and SP/TP MCB as outgoings etc. on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing, dressing the DB including termination etc. as required. ( Including closing vaccant slots using Dummy )
OD94739/2023-2024:Supply and providing the following MCCB/ RCCB / MCB / MCB Isolators/COS etc. to the existing DBs / MCS / Junction Boxes etc. including giving proper termination using suitable Bananna copper lugs, sleeves, insulation etc. complete.
Supply erection,testing and commissioning of centrifugal pump set for CWPM from WTP to Kuruvilacity discharge of 25 lps for a head of 110 m.
OD90424/2023-2024:Approval from Electrical Inspectorate /KSEB L
Supply erection,testing and commissioning of centrifugal pump set for CWPM from WTP to Swargamedu discharge of 9.5 lps for a head of 165 m.
OD90435/2023-2024:Approval from Electrical Inspectorate /KSEB L
Supply erection,testing and commissioning ofcentrifugal pump set for CWPM from WTP to Jamespadi discharge of 32 lps for a head of 140 m.
OD90436/2023-2024:Approval from Electrical Inspectorate /KSEB L
Supply erection,testing and commissioning of centrifugal pump set for CWPM from WTP to Poopara discharge of 38 lps for a head of 146 m.
OD90438/2023-2024:Approval from Electrical Inspectorate /KSEB L
Supply erection, testing and commissioning of 55HP Vertical turbine pump set at raw water pump house
OD85432/2023-2024:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with
OD85447/2023-2024:Earthing strip of 50 x 6 mm GI strip
OD85452/2023-2024:Submitting application to KSEBLfor power connection and power extension
Supply Erection ,testing and commissioning of 5 Ton capacity crane at CW pump house
OD94754/2023-2024:Design manufacture and supply of HOT overhead travers trolly crane 5 ton capacity chain-pully block and geared rolley having wall to wall horizontal movement etc. for smooth functioning of the crane as per IS Specification including all fittings and all incidental charges including painting the exposed surface with following specifications Type and construction of crane Single girder HOT (Design code IS 3832) Hook IS 8610 Load chain IS 6216(Alloy steel Grade 80) Hand chain IS 2420 MS Grade 30 brake type self actuating screw friction and disc type.
OD94753/2023-2024:Erection and commissioning of HOT over head crane including providing and fixing suitable size 45 x 45 MS base plate 18mm thick over the existing RCC shade 8 Nos brackets by drilling, fixing belt of suitable size and grouting with CM and welding LT grider ISHB 250 x 125 with MS base plate and also fixing the ends of the LT grider to the size suitably and also providing LT rail with suitable end stoppage. This also included provision for box type fabricated from rolled steel section and carriages of suitable construction with all good quality accessories line gears, wheels, axils, rubber buffers, bearing etc., the work also consists of all tools and equipment, labour supervision, load testing all safety devices and clarification of crane after completion of work. The rate inclusive of MS base plate and steppers and carriages etc.
OD94752/2023-2024:Supply, Fabrication and erection of long travel (LT) girder 300 mm depth fixing to the base plate at the existing bracket at site including cutting, hoisting and fixing in position and painting the exposed surface with two coats of zinc chromic primer and 2 coats of synthetic enamel paint including cost labor charges and conveyance of all materials etc., complete and as directed by the departmental officers.
OD94751/2023-2024:OD68953/2023-2024 Supply, Fabrication and erection of long travel(LT rains polished square bars of size 80 x 80mm thick to the LT girder and painting to the exposed surface as detailed in above item complete
Bidder Name
Tescons Projects Pvt. Ltd
stage.html
html • 0.02 MB
finance_1250964.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .