Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.4 LAccepted-AOC | L1 | Accepted-AOC FIRST LOWEST BIDDER | |
| 2 | L2₹23.8 L+₹2.3 L (10.7%)Rejected-AOC SHOP NO 1 KARGI CHOWK HARIDWAR BY PASS DEHRADUN UTTARAKHAND | L2 | Rejected-AOC SECOND LOWEST BIDDER | |
| 3 | L3₹24.0 L+₹2.5 L (11.4%)Rejected-AOC | L3 | Rejected-AOC THIRD LOWEST BIDDER |
Tender Value
₹23.5 L
EMD Value
₹47,000
Closing Date
16 Mar 2022, 6:00 pmClosed
GE I RND DEHRADUN
GE I RND DEHRADUN DEAL RESIDENTIAL COMPLEX RAIPUR ROAD DEHRADUN 248008
PROVISION OF DRAIN COVER OVER DRAIN AT AREA B TYPE BLOCK AT IRDE RESIDENTIAL COMPLEX VIGYAN VIHAR AND ADDITION/ ALTERATION IN RIGHT WING OF BUILDING NO P 65 OF TECHNICAL AREA AT DEAL AND CERTAIN SANCTIONED MINOR WORKS UNDER GE I R N D DEHRADUN
2022_MES_509915_1
GE(I)RND/9110/E8/21-22
Open Tender
Civil Works
Item Rate
180 days
DEAL DEHRADUN
Class E Category a (i) FOR UNENLISTED CONTRACTOR (i) Enlistment criteria may be seen in Para 1.4 of section of Part I of MES Manual on contracts-2007 (Reprint 2020) as available in all MES formations (ii) Copy of police verification /passport.
7 documents required · 7 mandatory
₹500
GE I R N D DEHRADUN
₹47,000
22 Mar 2022
23 Feb 2022
18 Mar 2022
23 Feb 2022
16 Mar 2022
2 Mar 2022
23 Feb 2022 - 2 Mar 2022
Amount
Taking down chowkats or frames with shutter (without taking off shutters from the frame) n. exc. 1.50 sqm each complete all as specified and directed.
Demolition of brick or stone boulder masonry built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stone works and precast concrete articles, complete all as specified and directed
M&L Brick work with old size sub class B bricks straight or curved on plan exc 6m mean radius built in CM 1:6 Complete all as Specified and directed
Taking down cement or cement lime plaster of any description including racking out joints, hacking for keys , scrubing down with water etc, complete all as specified and directed.
M&L for 15mm thick plastering in CM (1:6) on fair faces of brick work or concrete surfaces finished even and fair without using extra cement complete all as specefied and defected
M&L two coat, of oil bound distemper over one coat of alkali priming resitant paint of newly plastered surfaces of wall after prepration of surface over a coat of 1 mm thick wall care puttty complete all as specified and directed.
M&L for complete removal of existing treatement by scraping, washing, rubbing down or stopping distempered or painted surfaces etc of walls plastered or un-plastered & removing all vegetation growth, cleaning & applying of Birla/JK white wall putty (Approx 1 mm thick) as per manufacturer's instruction on existing prepared surface and make the surface smooth by rubbing with sand papers etc and applying two coats of oil emulsion distemper over a coat of water proof primer complete all as specified and directed. Note :- Work will be carried out from ground floor to forth floor in necessary scafolding and safety measures and labour insurance etc complete.
M&L PVC Sheet wall panneling of solid thickness 5 mm consisting of pannels of desired size stuck on inner frame work of 50 mm wide strips of 5mm thick prelam PVC sheet. The panel & strips shall be of 600 Kg/cbm density manufactured by ISO-9000 certified companyusing 65 mm long M.S screw shall not more than 200mm. A Groove of 2mm may be left at the joint of two panels for asthetic looks.The exact size of the panels and coorspondingly of the grid may vary depending on the size of the wall. Optionallya U Channel at top, bottom and side edges and strips of 5mm thick PVC sheet of width 75 mm feathered at the edges shall be stuck at the places where two panels are joined, using solvent cementcomplete all as specified and directed Note: The above work excute necessary fittings and scafolding for heighted site. Make: Rajsheree or other equivalent makes as approved by GE
S&F in repair 18 mm thick solid factory made MDF Board (Grade II & Type-II ,IS 12823: 1990; Reaffirmed 2005) and Inside facia / fabric panel with soft board with minimum 18 mm thickness , MDF board panel finished with 0.8mm thick laminate from floor level to top matching colured edge bonding tape to cover all edges , Magnetic catcher including all fittings as in cupboard, selves, almirah etc as per specification & and as per manufacturer's instruction complete all as specified & directed.
S&F Brass handles 100mm size, cast type, polished bright as approved complete all as specified and directed
S&F 40 mm dia, brass, knobs for cupboard fixed with nut, screw and washer of mild steel, bright finised complete all as specified and directed.
S&F L band size 50 mm complete all as specifed and directed.
S&F Auto closing projected type hinges ( Al- Bihari ), Stainless steel, bright finish including steel screw etc complete all as specified and directed.
S&F Brass Locks 2 levers, cupboard, grade I, size 50 mm complete all as specifed and directed.
S&F Mild steel heavy duty telescopic chanel with roller bright finish including steel screw as per manufacturer instruction etc complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete as specified and attached
S&F for framed work such as grills, gratings, etc.. With ends of bars shouldered and riveted, or forged into spikes, framed guard bars, barred iron doors ladders, framed balusters, walk ways, railings, framework of water tanks and similar work con-forming to Fe. 290. Gde-E-165. Note (ii) :- The Work will be carried out upto 6 story with us in necessary scafolding and safety measures and labour insurance etc complete.
S&F powder coated aluminium frame for doors, windows or partition including aluminium beading, hinges of required size,jointing cleats, screws, dash,fastners,plug for fixing with wall, columns etc complete all as specified and directed.
S&F powder coated of any colour aluminium door shutters, aluminium section like lock rail, bottom rail 115x38/40 mm and top rail and vertical rail 100x38/40 mm including necessary jointing cleats/glazing clipx, rubber neorene paking, handles 02 Nos in each door, locking arrangment, aluminium snap beading screw etc, complete all as specified and directed. Note: panels likes prelaminated particle board / sheet glass shall be measured and paid seprately under respective item in BOQ/Sch 'A'
M&L for 4.8 mm thick sheet glass ordinary quality in panes exc 0.50 sqm each pane fixed with & including rubber gasket in aluminium frame work complete all as specified and directed.
M&L for Dismantling of wall and ceiling boards any thickness including cover filletscomplete all as specified and directed.
M & L 12mm thick POP/gypsum board ceilng with concealed metal grid system comprising of 80 x 26 x 0.55mm as ceiling section 20 x 27 x 30 x 0.55mm as perimetar channel & 15 x 45 x 15 x 0.9mm as inter mediate channel complete. Frame structure suspend fram roof by ceiling angle of size 25 x 10 x 0.55mm complete all as specified and directed.
S&F coloured 1 mm thick zebra venetian blind ,roller venetian ,vertical venetian with opening and closing arrangement including aluminium hanging channel at top with sliding wheel/ring including pulling rope in both side and necessary accessories complete all as specified and directed. NOTE:- Coloured of venetian shall be approved by GE
(a) Polyurethane Foam (PUF) Wall Panels of 60mm thick (Make :ACE/ LLOYD/BNAL Pre Fab/Modern Pre Fab/Me Techno or equivalent) with both inner and outer sheet of the panel made of GI Metal plain sheet of 0.63mm with slight ribs. Inner and Outer sheets to be of 240 MPa GI with 180 GSM Zn coating/300 MPa galvalume steel with 150 GSM Alu-Zn Coating with interlocking arrangment including "U" chanel with following specification :- (i) Outer sheet profile : profiled GI metal plain sheet (ii) Inner sheet profile : GI Metal plain sheet with slight ribs. (iii) Panel thickness : minimum 60mm. (iv) Facing Material thickness of not less than 0.63mm outer and inner with DFT 20 microns colour coate MP/SMP/PVDF coating over 5 icron primer (v) Polyurethane Foam (PUF) CFC & HCFC free rigid PUF as per IS 12436 standard (vi) Foam overall density : 40 + 2kg/cu.m (vii) Foam thermal conductivity (K-value) at 10 degree centigrade mean temp.:0.023 W/m degree K (viii) Compressive strength @ 10% deformation : 2.10 Kg/ sq.cm. 205.93 Kpa (ix) Tensile strength : 2.5 Kg/sq.cm (x) Flexural/Bending strength : 90-95% (xi) Fire Characterstic : Fire retardant, self extinguishing and quality foam. (xii) Water absorption : 0.2% volume at 100% RH -max. (xiii) Dimensional stability at - -25 degree Centigrade Cold Temp and - +/- 2% +70 degree Centigrade Hot Temp should be - +/- 2%. (xiv) Green rating Point : 5 Note : The colour/ shade of panal will be approved by GE
M&L for PCC type C1 1;3:6 using (20 mm graded crushed stone aggreaget) cement concrete in roof kerbs or mud stops, lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses,lacing courses, parapets and railing upto 60 cm in height, opings, kneelers, apex stones,bed plates, water roughs and the like including weathring slightly round chamfered angles and throating, as directed runded or chamfered on edges complete all as specified and directed.
M&L Precast cement concrete type B1 1:2:4 (using 20mm graded crushed stone aggregate) as in landings, cover slabs (for manholes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces and set in CM 1:6 complete all as specified and directed.
S&F mild steel TMT bars conforming to Fe-290 (Gde E-165) 10mm dia and over, cut to length, bent to shape required,including binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
M & L for painting in preparation of new untreated surfaces . One coat of priming with red oxide and two coat of synthetic enamel (ordinary tint). Paint complete all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out complete all as specified and as directed
M & L Returning fillng in , including spreading , levelling , watering and well ramming in layers not exc 25cm complete all as specified and directed.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
M & L for PCC 1:4:8 Type D2 using 40mm graded aggregate as in foundations, filling and mass concrete complete all as specified and as directed .
M & L for 15mm thick rendering on fair faces of brick wall using CM 1:4 and finished with even and fair complete all as specified and directed.
M&L reinforced concrete pipes, Class NP-2 laid and jointed complete with coller of size/ dia 450mm complete all as directed
M&L for concrete bed in PCC 1:4:8 type D-2 to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested for 450mm bore of pipe. complete all as specified and directed.
M&L for point wiring with single core PVC insulated unsheathed 1100 volt grade FRLS-IS 694 cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and including non metallic rigid PVC conduit medium duty ISI marked not less than 20mm dia, concealed conduit wiring in walls and surface with GI saddles, GI screws, rawl plugs in ceiling or roof including Tee, Junction boxes and provision of flush metal boxes, inner and outer plate suitable for modular switch, socket and fan regulator as per site requirement and drawing continuous earth wire with and including PVC insulated unsheathed 1100 Volts grade FRLS-IS 694 cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) and connected to main earth dolly for one ligjt control by one switch complete all as specified
All as per Srl item No above for point wiring 5 pin switch socket outlet, 5/6 Amps on independent board complete all as specified and directed.
All as per item No 2 above for one power point 3 pin 15 Amps socket out let PVC insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 2.5 Sq mm (Nominal area) including earth wire PVC insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 1.5 Sq mm (Nominal area)cable common connected to earth dolly, all as specified for one 3 pin 15 amps socket outlet point controlled by one switch complete. Make of cable and conduit: Havells/Polycab/Gloster as approved by GE.
S&F Modular switch piano single pole one way 6 amp complete. Make -Legrand /GM Modular/ Havells as approved by GE.
S&F Modular switch piano single pole one way 16 amp complete. Make - Legrand / GM Modular/ Havells as approved by GE.
S&F Modular socket outlet 2/3 pin combined 2 module 6/16 amp complete. Make -Legrand / GM Modular / Havells as approved.
S&F Modular socket outlet 2/3 pin combined 2 module 6 amp complete. Make -Legrand /GM Modular/ Havells as approved by GE.
Supplying, fixing & testing recess mounting in built ,24 Watts,2'x2' LED ceiling light fitting with slim line extruded aluminium/ CRCA body, opal acrylic diffuser, electronic driver etc and all accessories pre wired including connecting to source complete all as specified & directed. Make- C&G Cat Pt No LCTLRNE-24-FO-CDL or equivalent in Phillips/Havells as approved.
Suply and fix wall mounted air circulator fans 230V single phase oscillating 450mm sweep complete with all accessories all as specified and directed by GE. Make: Havells Cat Pt No. FHWV3TFSLB18 or equivalent in Bajaj/ Crompton
S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole and neutral MCB 20 amp,240Volts power coated CRCA steel sheet enclosure recess mounted with chained metal cover for the socket outlet. Make of SPN DB with MCB 20Amp - of Indo Asian/Legrand/Havells as approved by GE.
M&L sub main wiring using four single core PVC insulated, unsheathed stranded copper conductor cable of size 16 Sqmm of voltage rating upto and including 1100 Volts drawn in and including concealed PVC conduit (Medium grade) of suitable dia not less than 25 mm dia with standard accessories along-with two run of PVC(green colour) insulated , unsheathed, stranded copper conductor of size 10 Sqmm as earth continuity conductor complete all as specified and directed.
S&F TPN distribution board ,double door, 4 way, AC 3 Phase 415 volt suitable for IP:43 protection, isolated neutral bar, cement spill protector, door earthing, mechanical impact strength IK09 with provision of 63 Amp isolator as incomer and SP MCB's as out going complete all as specified and directed by Engr-in-Charge. Make of TPN DB:-IndoAsian cat Part No-811841 or equivalent make in Havells/L& T.
S&F MCB TPN 'C' Curve 63 Amp suitable for fixing in TPN DB 415V with all specifications as mentioned above in Item No. complete all as specified and directed Make: Indoasian Cat Pt No. 811220 or equivalent make from Havells/Legrand as approved by GE.
S & F MCB SP 240 volts 'C' Curve suitable for fixing in DB of capacity 6 to 32 Amps complete, all as specified.Make -IndoAsian cat ref no 811122/24/26/27/28/29 or equivalent in Havells or Legrand as approved by GE.
M&L for earthing complete for building with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level connected to galvanized earth wire 4.00 mm dia by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish, internal surface of concrete chamber shall be given 15mm thick plaster in cement mortar 1:4, funnel with wire mesh, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) and specified including provision of earth wire protected by 15mm dia medium grade GI pipe and watering GI pipe shall be 20mm bore medium grade etc complete, inculding all necessary excavation and earth work & connecting the earthing to an earthing test point main switch board as specified and testing on completion complete all as specified & directed. NOTE : RCC pit cover shall be pre-cast of RCC (1:2;4) type B-1 80 mm thick reinforced with XPM weighting not less than 4 Kgs/Sqm in lieu of CI cover.
Supply, fixing & testing split unit air conditioner electic driven 5 star rated single phase of capcity 2 TR with cordless remote controal unit, with cooling and heating function, PM 2.5 air fiter anti viral dust fitter complete with all accessories complete all as specified and directed. Make: Lloyd/LG/Blue Star as approved by GE
Supply and fix voltage stabilizer for automatic operation single phase naturally air cooled indoor typer and disigned for inpurt variation between 170V to 250V with output voltage stabilized at 230V with accuracy of 2.5% and of capacity 5 KVA complete all as specified and directed.
Supply and fixing single phase electronic KWH energy meter of accuracy class 1.0, rating currert 10-60 Amp, 240 volt 50 Hz counter type dishplay with transperant hinge type box with sealing screw procision (LCD mini) etc at different location at residential and technical area coplete all as specified and directed Make: L&T, HPL or other equvilnt makes as approved by GE.
Supply, fixing & testing desert cooler star rated electric driven (single phase) with stand having, tank capacity - 65 Ltr, power consumption - Cooling 350 Watt, 3 speed setting of Model No Windsor 65 white colour, cooling media - Wool Wool + honneycomb, No. of speed - 3, blower type of dimension 81 Cm x114CmX44Cm of plastic/PVC body complete with all accessories all as specified and as directed. MAKE :-Havells/Bajaj/Voltas
OM TRADERS
M/S P K ARORA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .