Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.7 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹46.4 L+₹6.7 L (16.9%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹46.5 L+₹6.8 L (17.2%)Rejected-Finance RANGAPARA TOWN WARD NO 1 PS PO RANGAPARA DIST SONITPUR ASSAM | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | Rejected-Technical GARUBANDHA MISSAMARI DIST SONITPUR ASSAM 784 506 | SONITPUR | ASSAM | 784506 | - | Rejected-Technical NOT VALIDATED (NOT ENLISTED IN CATEGORY c(i) ) | |
| 5 | Rejected-Technical P O P S MISSAMARI DIST SONITPUR ASSAM 784506 | SONITPUR | ASSAM | 784506 | - | Rejected-Technical NOT VALIDATED (NOT ENLISTED IN CATEGORY c(i) |
Tender Value
Refer Docs
EMD Value
₹98,000
Closing Date
3 Oct 2024, 6:00 pmClosed
GE MISSAMARI
PO-Missamari Dist-Sonitpur Assam
REPAIR/MAINTENANCE OF SUMMER APPLIANCES INCL MECHANICAL LAUNDRY UNDER GE MISSAMARI
2024_MES_673589_1
8509/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE MISSAMARI
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GE MISSAMARI
₹98,000
Yes
2 Dec 2024
10 Sept 2024
5 Oct 2024
10 Sept 2024
3 Oct 2024
25 Sept 2024
11 Sept 2024 - 17 Sept 2024
Amount
Repairs/Servicing Air Conditioner 1.50 Ton Capacity, Window type at Site of any Make and any type by replacing unserviceable Parts (like Compressor and other Minor Parts viz Capilary Tube, Machine Screws, Washer, Rubber Bush, etc) from the Machine including Charging of Refrigerant Gas after vacuuming and leak testing, brazing the suction/discharge tubes where required and cleaning of Condensing Unit to achieve proper Cooling effect, checking of Electrical Circuit of machine and repair where necessary by replacing proper size PVC insulated Wires and cleaning of AC using air blower as directed, commissioning & Testing, complete all as specified and directed. NOTE : (i) Compressor, Refrigerent gas and other Spares Parts wherever required will be Measured and Paid separately under respective Items. (ii) QUOTED UNIT RATE shall also deemed to be included for any Minor Parts such as Capilary Tube, Machine Screw, Washer, Rubber Bush, etc. required for proper setting of Machine.
M&L for leakage testing of window AC refrigerant flow system including Compressor by dry nitrogen complete all as specified and directed .
Supply only Compressor of Air Conditioner 1.50 Ton Capacity Window type, reciprocating type, hermitically sealed, complete all as specified and as directed.
Supply only Running Capacitor 45/6 mfd 230 Volt, 50 Hz (as approved) suitable for Air Conditioner 1.50 Ton Capacity, Window type complete all as specified and as directed.
Supply only Thermostatic Switch (as approved) suitable for Air Conditioner 1.50 Ton Capacity Window type, complete all as specified and as directed.
Supply only Blower Motor, Single Phase 230 Volt, 1500 RPM, 1/5 HP, (as approved) suitable for Air Conditioner 1.50 Ton Capacity Window type, complete all as specified and as directed.
Supply only Fan blade for Blower Motor, PVC of any size suitable for Air Conditioner 1.50 Ton Capacity Window type, complete all as specified and as directed.
Supply only Front Cover with Grill (as approved) suitable for Air Conditioner 1.50 Ton Capacity, Window type, complete all as specified and as directed.
Supply only Auto Sensor Unit Kit / AC main board (PCB) with display unit for remote control system (as approved) suitable for Air Conditioner window type 1.5 TR Capacity as per original model of existing make of split AC, complete all as specified and as directed.
Supply only Over Load Protector/ Over load Relay (as approved) suitable for Air Conditioner 1.50 Ton Capacity Window type, complete all as specified and as directed.
Supply only Universel Strainer Filter-cum- dryier (as approved) made of Copper suitable for Air Conditioner 1.50 Ton Capacity Window type, complete all as specified and as directed.
Supply only Refrigerant Gas (as approved) as required in the unit for Air Conditioner 1.50 Ton Capacity Window type, type, complete all as specified and as directed.
Supply and Filling of Refrigerant Gas (as approved) as required in the unit for Air Conditioner 1.50 Ton Capacity Window type, type, complete all as specified and as directed.
Repair/Servicing of Air Conditioner split type at site (Air Conditioner comprises wiith out door and Indoor Unit complete) 1.5/ 2.0 TR Capacity of any Make and any type by replacing unserviceable parts from the machine including charging of refrigerant gas after vacuuming and leak testing, brazing suction/ discharge tubes where required and cleaning of condensing unit to achieve proper cooling effect, checking of electronic circuit of the machine and repair where necessary by replacing electronic parts and changing of wirings with proper size PVC insulated wires and cleaning of AC using air blower as ordered, reinstallation the Air Conditioner at location where directed after proper repairing and testing complete at site, complete all as specified and as directed. NOTE : (i) Compressor, Refrigerent gas and other Spares Parts wherever required will be Measured and Paid separately under respective Items. (ii) QUOTED UNIT RATE shall also deemed to be included for any Minor Parts such as Capilary Tube, Machine Screw, Washer, Rubber Bush, etc. required for proper setting of Machine.
M & L for leakage testing of Split AC refrigerant flow system including Compressor by dry nitrogen complete all as specified and directed .
Supply only running capacitor 45/6 mfd 230 Volt, 50 Hz (as approved) suitable for Air Conditioner split type 1.5/2.0 TR capacity complete all as specified and as directed.
Supply only Capacitor 2.5 mfd (as approved) 230 Volts, AC, 50 Hz, complete all as specified and as directed.
Supply only contactor 25 Amp, single pole AC, 230 Volt, suitable for outdoor unit of Air Conditioner split type 1.5/2.0 TR capacity, complete all as specified and as directed.
Supply only Refrigerant Gas (as approved) suitable for Air Conditioner split type 1.5/2.0 TR capacity, complete all as specified and as directed.
Supply only compressor (as approved) suitable for Air Conditioner 1.5 TR capacity, split type, complete all as specified and as directed.
Supply only compressor (as approved) suitable for Air Conditioner 2.0 TR capacity, split type, complete all as specified and as directed.
Supply only compressor (as approved) suitable for inverter Air Conditioner 1.5/2.0 TR capacity, split type, complete all as specified and as directed.
M&L Nitrile Insulation 5.0 mm thick with rapping tape on existing suction & discharge copper line of Air Conditioner Split type 1.5/2.0 TR capacity complete all as specified and as directed.
Supply only Sensor unit (as approved) suitable for indoor of Air Conditioner split type 1.5/2.0 TR Capacity as per original model of existing make of split AC, complete all as specified and as directed.
Supply only Auto Sensor Unit Kit / AC main board (PCB) with display unit for remote control system (as approved) suitable for Air Conditioner split type 1.5/2.0 TR Capacity as per original model of existing make of split AC, complete all as specified and as directed.
Supply only AC main board (PCB) for Inverter AC with display unit for remote control system (as per existing OEM make/model as approved) suitable for Outdoor unit of Air Conditioner split type 1.5/2.0 TR Capacity as per original model of existing make of split AC, complete all as specified and as directed.
Supply only AC main board (PCB) for Inverter AC with display unit for remote control system (as per existing OEM make/model as approved) suitable for indoor unit of Air Conditioner split type 1.5/2.0 TR Capacity as per original model of existing make of split AC, complete all as specified and as directed.
M&L Brass/Copper Check Nut of suitable size to Indoor/outdoor unit of Air Conditioner and fixed complete with gas welding, complete all as specified and as directed.
Supply only Condensing Coil Assembly (as approved) suitable for outdoor of Air conditioner 1.5 / 2 TON complete all as specified and as directed.
M&L Wall Mounting Bracket Company Made duly Powder Coated suitable for mounting AC 1.5/2.0 TR Split type, Outdoor Unit on Wall and fixed-in-repairs complete all as specified and as directed.
S&F Copper refrigerent gas pipe, 1/2 inch dia, fixed with necessary brazing and foam insulation including dismantling of existing unserviceable pipe, complete all as specified and as directed.
S&F Copper refrigerent gas pipe, 1/4 inch dia, fixed with necessary brazing and foam insulation including dismantling of existing unserviceable pipe, complete all as specified and as directed.
Supply only Blower Motor, Single Phase 230 Volt, 1500 RPM for indoor unit of Split type AC of capacity 1.5 TON/ 2 TON complete all as specified and as directed.
Supply only PVC/aluminium fan blade suitable for use with Blower Fan of outdoor unit of Split type AC of any capacity and Make, complete all as specified and as directed.
Supply and filling of Refrigerant Gas (as approved) suitable for Air Conditioner split type 1.5/2.0 TR capacity, complete all as specified and as directed.
Supply only PVC flexible drain water pipe (as approved) suitable for indoor unit of Air conditioner of capacity 1.0/1.5 / 2 TON complete all as specified and as directed.
Supply only AC air filter (as approved) suitable for indoor unit of Air conditioner of capacity 1.0/1.5 / 2 TON complete all as specified and as directed.
Supply only Remote (as approved) suitable for Air conditioner 1.0/1.5 / 2 TON complete all as specified and as directed.
S&F 1100 volts grade heavy duty cable PVC insulated aluminium stranded conductor of 10 Sqmm, served with inner sheathing of PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm supension wire , twin core cable flat or circular cable including taking down old unserviceable cable complete all as specified and directed .
S&F sheet metal enclosure plug and socket with 200 Amps rated bus bar 240 volts with one MCB SP 20 Amps complete all as specified.
Supply only Voltage stabilizer having Input voltage range 90 Volts - 290 Volts (as approved) suitable for Air conditioner 1.0/1.5 TON complete all as specified and as directed.
Supply only Voltage stabilizer having Input voltage range 90 Volts - 290 Volts (as approved) suitable for Air conditioner 2 TON complete all as specified and as directed.
Repair /Servicing of Refrigerator/Deep Freezer of any Capacity and any Make by replacing unserviceable compressor and minor Parts required for smooth functioning of refrigerator or deep freezer, Charging of Refrigerant Gas after vacuuming and leak testing, brazing the Suction /Dis-charge Tubes where required and cleaning of Condensing Unit to achieve proper Cooling effect and Testing on completion, complete all as specified and as directed. NOTE : (i) Compressor, Refrigerent gas and other Spares Parts wherever required will be Measured and Paid separately under respective Items. (ii) QUOTED UNIT RATE shall also deemed to be included for any Minor Parts such as Capilary Tube, Machine Screw, Washer, Rubber Bush, etc. required for proper setting of Machine.
M & L for leakage testing of Refrigerator/Deep Freezer of any Capacity and any Make refrigerant flow system including Compressor by dry nitrogen complete all as specified and directed .
Supply only Compressor for Refrigerator 165 to 210 LITRE capacity, complete all as specified and as directed.
Supply only Compressor for Refrigerator 220 to 320 LITRE capacity and Deep Freezer 200 to 400 LITRE capacity, complete all as specified and as directed.
Supply only charging of Non CFC Refrigerant to the Refrigeration Line of Refrigerator 165 to 210 LITRE capacity of any Make, complete all as specified and as directed.
Supply only charging of Non CFC Refrigerant to the Refrigeration Line of Refrigerator 220 to 320 LITRE and Deep Freeazer of capacity 200 to 400 Ltr capacity of any Make, complete all as specified and as directed.
Supply only Copper Universel Strainer Filter-cum-dryier (as approved) suitable for Refrigerator/Deep Freezer of any capacity, complete all as specified and as directed.
Supply only Thermostatic Switch suitable for Refrigerator and Deep Freezer of any type, complete all as specified and as directed.
Supply only Lamp 15 Watt Thread/Pin type (as approved) suitable for Refrigerator of any capacity, complete all as specified and as directed.
Supply only Cooling Coil with Chamber (as approved) suitable for Refrigerator any make any capacity complete all as specified and as directed.
Supply only Door Gasket (as approved) suitable for Refrigerator any make any capacity complete all as specified and as directed.
Supply only Chiller Door of approved Brand, suitable for Refrigerator any make any capacity complete all as specified and as directed.
Supply only Condensing Coil Assembly (as approved) suitable for Refrigerator of any make and any capacity complete all as specified and as directed.
Supply only Chiller Tray (as approved) suitable for Refrigerator of any make and any capacity complete all as specified and as directed.
Supply only Vegitable/Fruit Tray (as approved suitable for Refrigerator of any make and any capacity complete all as specified and as directed.
Supply only Relay, Box/Pin type Combined with Over Load Protector/ Over load Relay (as approved) suitable for Refrigerator of any make any capacity complete all as specified and as directed.
Repair /Servicing of Water Cooler of any Capacity and any Make by replacing unserviceable Parts (like Compressor and minor Parts required for smooth functioning of Water Cooler, charging of Refrigerant Gas after vacuming and leak testing, brazing the Suction /Discharge Tubes where required and cleaning of Condensing Unit to achieve proper Cooling effect and Testing on completion, complete all as specified and as directed. (i) Compressor, Refrigerent gas and other Spares Parts wherever required will be Measured and Paid separately under respective Items. (ii) QUOTED UNIT RATE shall also deemed to be included for any Minor Parts such as Capilary Tube, Machine Screw, Washer, Rubber Bush, etc. required for proper setting of Machine.
M & L for leakage testing of Water Cooler refrigerant flow system including Compressor by dry nitrogen complete all as specified and directed .
Supply only Compressor (as approved) suitable for Water Cooler of capacity 40/80 ltr, complete all as specified and as directed.
Supply only Compressor (as approved) suitable for Water Cooler of capacity 60/120 ltr, complete all as specified and as directed.
Supply only Compressor (as approved) suitable for Water Cooler of capacity 150 ltr, complete all as specified and as directed.
Supply only Refrigerant as per Site requirement to the Refrigeration Line of Water Cooler 40/80 LITRE capacity of any Make, complete all as specified and as directed
Supply only Non-CFC Refrigerant as per Site requirement to the Refrigeration Line of Water Cooler 60/120 &150 LITRE capacity of any Make, complete all as specified and as directed.
Supply only Thermostatic Switch (as approved) suitable for Water Cooler of any capacity, complete all as specified and as directed.
Supply only Magnetic Door Gasket (as approved) suitable for Water Cooler of any make and any capacity complete all as specified and as directed.
Supply only Push Cock Spring Loaded 15mm dia, Cast Copper Alloy, Chromium plated along with Gasket, complete all as specified and as directed.
Supply only Blower Motor, Single Phase 230 Volt, 1/32 HP, suitable for Water Cooler 40/80 LITRE capacity of any Make, complete all as specified and as directed.
Supply only Blower Motor, Single Phase 230 Volt,1/8 HP, suitable for Water Cooler 60/120 and 150 LITRE capacity of any Make, complete all as specified and as directed.
Supply only PVC Connecting Pipe 60 Cm long with Brass Coupler suitable for GI Pipe 15mm bore (dia) suitable for Water Cooler of any capacity and Make, complete all as specified and as directed.
Supply only PVC/aluminium fan blade suitable for use with Blower Fan of Water Cooler of any capacity and Make, complete all as specified and as directed.
Supply only Running Capacitor 10 mfd 230 Volt, 50 Hz, suitable for Water Cooler of any capacity and Make, complete all as specified and as directed.
Supply only Starting Capacitor 60 to 80 mfd 230 Volt, 50 Hz, suitable for Water Cooler of any capacity and Make, complete all as speci-fied and as directed.
Supply only Relay pin type with Over Load Protector/ Over load Relay suitable for Water Cooler, complete all as specified and as directed.
Supply and filling of Non-CFC Refrigerant as per Site requirement to the Refrigeration Line of Water Cooler 40/80 LITRE capacity of any Make, complete all as specified and as directed
Supply and filling of Non-CFC Refrigerant as per Site requirement to the Refrigeration Line of Water Cooler 60/120 &150 LITRE capacity of any Make, complete all as specified and as directed.
M&L disconnecting and taking down Ceiling Fan/Wall Mounted/Exhaust Fan/Air Circulator of any Sweep by Electrical Connections, cleaning Internally and Externally thoroughly, replacement of Split Pins, Cotter Pins and Check-nuts, etc. overhauling, lubricating with approved Lubricants, re-assembling including replacement of wornout/defective Parts, re-fixing in Original Position after Minor Repairs for the smooth functioning and including electrically connected with Flexible Wire multi -stranded Copper Conductor Cable of size 23/0.0076 from Ceiling Rose to Fan/Air Cir-culator including filling Cavities with Filler one coat after cleaning all dust, etc. and Painting of Fan/Air Circulator with Synthetic Enamel Paint (as approved) with using Spray Painting Machine and writing MES No. with Black Paint and Testing, complete all as specified and as directed. NOTE: Necessary repairs/replacement of unserviceable Parts shall be measured and paid under appropriate Items.
M&L rewinding Ceiling Fan 1200/1400mm Sweep of any Make and type with Super Ena-meled Copper Winding Wire as per existing size and gauge including heating, varnishing complete and replacement of unserviceable/ wornout Points for statisfactory running and including electrically connected with Flexible Wire multi-stranded Copper Conductor Cable of size 23/0.0076 from Ceiling Rose to Fan and testing, complete all as specified and as directed.
M&L rewinding Exhaust Fan upto 300 mm sweep of any Make with super enameled Copper Winding Wire as per existing size and gauge including heating, varnishing, replacement of unserviceable/worn out Parts for satisfactory Running including electrically connected with Flexible Wire multi-stranded Copper Conductor Cable of size 23/0.0076 from Ceiling Rose to Fan/Air Circulator and testing, complete all as specified and as directed
M&L rewinding Exhaust Fan 330 to 450mm Sweep and air circulator upto 450mm sweep of any Make with super enameled Copper Winding Wire as per existing size and gauge including heating, varnishing, replacement of unserviceable/worn out Parts for satisfactory Running including electrically connected with Flexible Wire multi-stranded Copper Conductor Cable of size 23/0.0076 from Ceiling Rose to Fan and testing, complete all as specified and as directed.
M&L rewinding wall fan/Air circulator upto 400 to 750 mmsweep of any Make with super enameled Copper Winding Wire as per existing size and gauge including heating, varnishing, replacement of unserviceable/worn out Parts for satisfactory Running including electrically connected with Flexible Wire multi-stranded Copper Conductor Cable of size 23/0.0076 from Ceiling Rose to Fan and testing, complete all as specified and as directed.
Supply only Ball Bearing No. 6201 (as approved) suitable for Ceiling Fans/Exhaust Fans, complete all as specified and as directed.
Supply only Ball Bearing No. 6202 (as approved) suitable for Ceiling Fans/Exhaust Fans, complete all as specified and as directed.
Supply only Ball Bearing No. 6203 (as approved) suitable for Ceiling Fans/Exhaust Fans, complete all as specified and as directed.
Supply only Ball Bearing No. 6204 (as approved) suitable for Ceiling Fans/Exhaust Fans, complete all as specified and as directed.
Supply only Gun metal Bush (as approved) suitable for Ceiling 1200/1400mm sweep complete all as specified and as directed.
Supply only Capacitor 2.5 mfd (as approved) 230 Volts, AC, 50 Hz, complete all as specified and as directed.
Supply only Capacitor 3.5/4.0 mfd (as approved) 230 Volts, AC, 50 Hz, complete all as specified and as directed.
Supply only Rubber Reel Insulator (as approved), complete all as specified and as directed.
Supply only Galvanised Steel Bolts and Nut 10mm dia 50mm long with Washer half threaded duly drilled hole at threaded End for Split Pin and One Split Pin with each Bolt, complete all as specified and as directed.
Supply only Fan Shaft (as approved) suitable for Motor of Ceiling Fan 1200/1400 mm Sweep, complete all as specified and as directed.
S&F Flexible Copper Cable PVC insulated unsheathed 2.5 Sqmm 3 Core 230 Volts grade and fixed-in-repairs, complete all as specified and as directed.
S&F in repair Socket Outlet 3 Pin 16 Amp, Flush type, ISI Marked complete all as specified and as directed.
S&F in repair Switch Flush type 16 Amp, Outlet complete all as specified and as directed.
S&F in repair Plug Top of 16 Amps capacity, complete all as specified and as directed.
Servicing Air Conditioner window type/Split type( Indoor and outdoor unit) 1.50/2.00 Ton Capacity, of any make at Site of any Make and any type by using air blower, cleaning foam including other means of cleaning of condensing unit and indor unit to achieve proper cooling effect, checking of electronic circuit of the machine and including minor repair of AC at locations where directed after proper servicing anf testing complete at site as directed. NOTE : (i) QUOTED UNIT RATE shall also deemed to be included for any Minor Parts such as Capilary Tube, Machine Screw, Washer, Rubber Bush, etc. required for proper setting/functioning of Machine.
Dismantling and taking down for Repair/servicing of 3 Phase, 415 Volts, 19KW, 30 Kgs capacity, fully automatic industrial front loading Washing Machine, Make STEFAB INDIA LIMITED,Model No. LME 30 along with control panel dully disconnecting the electrical and mechanical connections for cleaning and servicing including necessary repair/maintenance by greasing, welding work where ever required, cleaning of moving parts and inner perforated moving drum, tigethening nuts and bolts and necessary electrical connection including testing complete for making it completely functional and replacement of damaged/unserviceable spare as required as directed NOTE: Necessary repairs/replacement of unserviceable Parts shall be measured and paid under appropriate Items.
Supply only Reversing Timmer (as approved) complete all as directed.
Supply only Solenoid Valve Diaphram (as approved) complete all as directed.
Supply only Drain Valve Solenoid (as approved) complete all as directed.
Supply only Flange Coupling with Coupling tyre (as approved) complete all as directed.
Supply only V Belt (as approved) complete all as directed.
Supply only Temerature Controlled cum Indicator (as approved) complete all as directed.
Supply only Water Valve (as approved) complete all as directed.
Supply only Indicator Lamp (as approved) complete all as directed.
Supply only Contactor 16 Amps (as approved) complete all as directed.
Supply only Citation (as approved) complete all as directed.
Supply only Over Load Relay Coil (as approved) complete all as directed.
Supply only Over Load Protector 3.8 to 6.00 Amps (as approved) complete all as directed.
Supply only MS Nut bolts big (as approved) complete all as directed.
Supply only MS Nut bolts small (as approved) complete all as directed.
Supply only Door switch assembly (as approved) complete all as directed.
Supply only PVC transparent water level pipe with check nuts (as approved) complete all as directed.
Dismantling and taking down for Repair/servicing of 3 Phase, 415 Volts, 19KW, 30 Kgs capacity, industrial HYDRO EXTRACTOR, Make STEFAB INDIA LIMITED,Model No. LX 30 along with control panel dully disconnecting the electrical and mechanical connections for cleaning and servicing including necessary repair/maintenance by greasing, welding work where ever required, cleaning of moving parts and inner perforated moving drum, tigethening nuts and bolts and necessary electrical connection including testing complete for making it completely functional and replacement of damaged/unserviceable spare as required as directed NOTE: Necessary repairs/replacement of unserviceable Parts shall be measured and paid under appropriate Items.
Supply only V Belt (as approved) complete all as directed.
Supply only Clutch Spring (as approved) complete all as directed.
Supply only Oil Seal (as approved) complete all as directed.
Supply only Break Lining with rivets (as approved) complete all as directed.
Supply only Suspension rod with nut (as approved) complete all as directed.
Supply only Spring of Suspension rod (as approved) complete all as directed.
Dismantling and taking down for Repair/servicing of 3 Phase, 415 Volts, 19KW, 30 Kgs capacity, industrial DRYING TUMBLER, Make STEFAB INDIA LIMITED,Model No. LME 30 along with control panel dully disconnecting the electrical and mechanical connections for cleaning and servicing including necessary repair/maintenance by greasing, welding work where ever required, cleaning of moving parts and inner perforated moving drum, tigethening nuts and bolts and necessary electrical connection including testing complete for making it completely functional and replacement of damaged/unserviceable spare as required as directed NOTE: Necessary repairs/replacement of unserviceable Parts shall be measured and paid under appropriate Items.
Supply only Temerature Controlled cum Indicator suitable for DRYING TUMBLER (as approved) complete all as directed.
Supply only Reversing Timmer suitable for DRYING TUMBLER (as approved) complete all as directed.
Supply only Contactor 16 Amps suitable for DRYING TUMBLER (as approved) complete all as directed.
Supply only Thermo couple suitable for DRYING TUMBLER (as approved) complete all as directed.
Supply only Over Load relay suitable for DRYING TUMBLER (as approved) complete all as directed.
Supply only Inlet Valve suitable for DRYING TUMBLER (as approved) complete all as directed.
Supply only Outlet Valve suitable for DRYING TUMBLER (as approved) complete all as directed.
Supply only V belt suitable for DRYING TUMBLER (as approved) complete all as directed.
Supply only Steam Trap suitable for DRYING TUMBLER (as approved) complete all as directed.
Supply only Idicating Lamp suitable for DRYING TUMBLER (as approved) complete all as directed.
Maa Mira Enterprise (BID ID -3124636)
United Traders (BID ID -3124097)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .