Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.5 LAccepted-AOC 181 1 1ST FLOOR SURYA NAGAR SURAJ KUND ROAD FARIDABAD HARYANA 121001 | FARIDABAD | FARIDABAD | HARYANA | 121001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹20.4 L+₹96,587.95 (4.96%)Rejected-Finance | L2 | Rejected-Finance Rejected |
Tender Value
₹23.7 L
EMD Value
₹47,420
Closing Date
27 Oct 2020, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EO
MC Ambala Sadar
Estimate for Electric Connection in Subhash Park Ward No. 17
2020_HRY_148362_1
DNIT/RE II/19/2020
Open Tender
Civil Works
Works
45 days
MC Ambala Sadar
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
EO MC Ambala Sadar
₹47,420
23 Dec 2020
20 Oct 2020
27 Oct 2020
20 Oct 2020
27 Oct 2020
20 Oct 2020
45 days
Amount
TRANSFORMER, 630KVA 11KV/433V Dyn11 Copper Wounded Cast Resin Dry Type Transformer with Off load tap links of +5% to -5% @2.5% with WTI scanner. Class of Insulation: H, Temperature rise limits 115 deg.C over an ambient of 50 degrees. Losses (Subject to IS Tol.) - NLL/LL - 1550/5800Watts and Impedance of 4.5%(Subject to IS Tol.) with WTI scanner.(Make- Schneider Electric, ABB, Siemens, C&S, Voltamp, kirlosker or as per approved list of PWD Haryana) = 1 no. Winding Temperature Indicator with 1 alarm and trip contact = 1 no. Surge arrestor in the HV side = 1 set AS PER PWD SPECIFICATIONS INCLUDING INSPECTION FROM CHIEF ELECTRICAL INSPECTOR HARYANA OUTDOOR ENCLOSURE, Outdoor type enclosure having construction of Galvanised Sheet Steel having 2mm thickness for Load bearing member and 1.5mm thickness for Non Load bearing members with 4 mm base frame. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP23 degree of protection for Transformer compartment. The enclosure exterior shall be Powder Coated (colour Light Gray & D.A. Gray ). Each compartment will be provided with the door and pad locking arrangement. The Compartment illumination lamp with door operated switch shall be provided for MV & LV compartment. Enclosure Class shall be K10. CSS shall be a type tested design for Internal arc classification of IAC-AB of 21kA for 1 sec as per IEC 62271-202 = 1 set
Supply & erection of lightning arrestor of SDU suitable for 11KV 3 Phase 50cycle grounded neutral system comprising of spark gap type quench gap types in series with non liner register element housed in horizontal seals porcelain bushing with line ground terminal along with mounting clamp conforming to ISS-3070 part-II of 1985 with latest amendments with all labour and material required up to the entire satisfaction of Engineer -in-charge of work as per UHBVN approved make
Supply & erection of fire extinguishers ISI mark CO2 type 4.5 kg. Capacity as per IS:7285 duly erected/ hang on wall with hooks with all labour and material required to complete the job in all respect to the entire satisfaction of Engineer-in-charge of work.
Supply and erection of 11 K.V gang operated switch Jayshree/Rastrya make conforming ot IS and latest amendment including suitable size of copper blade erection of same on existing H-pole with the help of 2 Nos. Channels of size 75x 40 x 6 mm thick 1.8 M long fixed with suitable size of M.S. Clamp, nuts and bolts including cost of 6 Nos 11K.V. Pin insulator with G.I. Pin, RD Fuses and painting with 2 coat of approved paint and one coat of red oxide including all labour and material required to complete the job in all respect to the entire satisfaction of Engineer-in-charge of work. as per UHBVN approved make
Supply and erection of stay wire suitable for 9 M long PCC pole made out of 7/3 SWG GI wire with U type M.S. Rod 5/8" dia duly threaded by means of angle iron of size 50 x 50 x 6 mm x 30 cm 6 feet long M.S. Rod buried in ground after fixing with cross channel size 75 x 40 x 6 mm x 60 cm long the stay wire will be binded on the top of the pole with help of suitable size of double U type M.S. Clamps and stay fixed with nuts and bolts the stay wire shall be insulated in the middle point with the help of egg insulator including all labour and material required to complete the job in all respect to the entire satisfaction of Engineer-in-charge of work.
S/E of MS bucket stand suitable for six Nos. fire buckets (but without buckets) including the cost of welding & painting with all cost of red oxide and two coat of enameled paint of red colour completion all respect.
Supply and erection of fire bucket of G.I. sheet of 24 gauge write with " FIRE" as per fire specification.
S/E of 11KV disc insulator/Pin Insulator with pin with labour and material required to complete the job including fixing the same on existing channel complete in all respect as per UHBVN approved make
S/E of M.S. channel, MS angle, MS flat & nuts & bolts of required size including painting and cutting etc. with labour and material required to complete the jobincluding fixing the same on existing pole complete in all respect
Supply & erection, Commissioning and testing of 11 KV indoor HT metering panel complete with Ct's PT's cubical & electronics meter with accuracy class 0.5. as par requirement / approved by DHBVN consisting of the followings : Cubical panel box standing floor mounting type made out of sheet steel 14 SWG CRCA sheet with channel iron base frame, spray painted with strong synthetic light grey enemal paint as per size and design approved by DHBVN/UHBVN. 3 Nos. 11KV CT's of suitable rating for indoor installation (As per - approved make of DHBVN/UHBVN). 1 No. 11 KV PT 11000/110 V 10VA burden 0.5 accuracy oil filled suitable for indoor installation of approved make of DHBVN/UHBVN. Electronic meter 3 phase 4 wires, 0.5 accuracy for recording reading in KWH of rating and make approved by DHBVN/UHBVN with push button display operating system for different kind of readings. The cubical panel will be complete in all respect including inter connection internal wiring with PVC copper cable its tasting and approval of all item from DHBVN/UHBVN with a guarantee of one year from the date of commissioning including cost of all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer in Charge of the work.
Bidder Name
Amount
A V ENGINEERS(GSTN-NA)
shiv shakti constructions(GSTN-NA)
Description of Work / Item(s)
As per Sheet 1
As per Sheet 2
A V ENGINEERS
A V ENGINEERS
A V ENGINEERS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .