Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.7 LAccepted-AOC 45 PIR BABA TARUSHAW ROAD HALWARA AD LUDHIANA 141106 | HALWARA | LUDHIANA | PUNJAB | 141106 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹38.9 L+₹2.0 L (5.46%)Rejected-Finance RAJKOT ROAD AIR FORCE STATION HALWARA 141106 PUNJAB | HALWARA | LUDHIANA | PUNJAB | 141106 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹39.0 L+₹2.1 L (5.73%)Rejected-Finance | L3 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹97,000
Closing Date
18 Oct 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Halwara
GE (AF) Halwara
ADDN/ALTN TO CERTAIN BLDG OF 2215 SQN AND CERTAIN FLAME PROOF WORKS AT AF STN HALWARA
2023_MES_619155_1
GE/HAL-38/2023-24
Open Tender
Civil Works
Item Rate
273 days
GE (AF) Halwara
MES ENLISTED CONTRACTORS CLASS D CATEGORY a(i) and b(i)
8 documents required · 8 mandatory
₹500
Yes
GE (AF) Halwara
₹97,000
Yes
26 Oct 2023
16 Sept 2023
20 Oct 2023
16 Sept 2023
18 Oct 2023
3 Oct 2023
Amount
Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in soft/ loose soil complete all as specified and directed.
Removing excavated material (Soil) exc. 250m but n. exc. 500m and depositing where directed complete all as specified and directed.
M&L for hardcore of broken stone or boulders guages not exc 63mm deposited, spread and levelled in layers not exc 15cm thick, watered and rammed to true surface complete all as specified and directed.
M&L for 100mm thick cement concrete 1:2:4 type B-1 using 20mm graded stone aggregates as in sub floors finished fair and even without using extra cement complete all as specified and directed.
M&L for 25 mm thick sand cushioning below interlocking tiles complete all as specified and directed.
M&L for 80mm thick Machine pressed precast concrete interlocking paver block (M-40 Grade) with grey cement and no pigments, any shape and size confirming to IS 15658-2006 and laid in pattern as decided by Engr-in-Charge complete all as specified.
Demolition of brick work built in cement mortar including all quoins, arches, pillars etc complete all as specified
M&L for brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and directed.
All as per Sl item No 8 above but built in cement mortar 1:4
Taking down cement plaster or cement lime plaster on brick walls etc including raking out joints, hacking for key , scrubbing down with water etc complete all as specified.
M&L for 15 mm thick rendering in cement mortar 1:6 on brick or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L for 15mm thick rendering on fair faces of brick work or concrete surfaces in cement mortar 1:4 finished surfaces fair and even without using extra cement complete all as specified and directed.
M&L for preparation of new plastered surfaces of wall and applying two coats of distemper oil emulsion over a coat of wall putty complete all as specified and as directed.
M&L for roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to Fe-410 (Gde E-250) complete all as specified and as directed
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixing with self taping screws complete all as specified and as directed
S&F gear operated type with bevel gear box and crank handle steel rolling shutters having thickness of laths 1.25 mm without ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer, erected in position as indicated complete all as specified and directed.
S&F Ball bearing for rolling shutter complete all as specified and directed.
M&L for preparation of new steel surfaces over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed.
S&F 1.25mm thick pressed steel frame of size 105x60mm for door with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc. complete all as specified. Note : Butt hinges fixed to door frames shall be measured seperately as "supply only" under respective items of this Sch/BOQ.
S&F 40mm thick flush shutter solid core construction with block board core and ply wood face panels commercial type on both sides, both faces are covered with decorative face veneer with lipping/frame to match complete all as specified and directed.
S&F door closer(Aluminium Die Cast) body hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg complete all as specified and directed.
S&F 200mm long Aluminium anodised barrel tower bolts of extruded section and fixed complete all as specified and directed.
S&F 300 mm long aluminum anodised sliding door bolts, Aluminium alloy ,door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium complete all as specified and directed.
Supply only 100 mm size butt hinges medium weight cold rolled mild steel all as specified.
S&F 125mm long Aluminium handles cast type anodised complete all as specified and directed.
S&F steel windows with side hung shutters including projecting type hinges with steel handle and steel peg stay complete with glazing bars devetailed or welded complete all as specified and directed.
M&L PCC 1:2:4 type B-1 using 20mm graded stone aggregates as in beams /bands, lintels over 1.5m span complete all as specified and directed.
M&L formwork to sides of beams/bands, lintels over 1.5m span for fair finished surfaces of concrete complete all as specified and directed.
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Alll as per Sl item No 29 above but 6mm to 8mm dia as in stirrups/spacer etc complete all as specified and directed.
M&L for flame proof, Zone I & II, Gas Group II A/ II B, weather proof submain wiring with four runs using approved colour coding as per IS, zero hologen flame retardent (HFFR) smoke free non toxic non corrosive PVC insulated unsheated flexible copper conductor cable of three run 4 Sqmm (1 phase+ neutral + earth) including ERW stove enamelled black rigid conduit of required size but not less than 25mm dia, flame proof conduit accessories such as tee, bend, elbow, junction box etc complete all as specified and directed
All as per item No 31.00 but one run of 6 Sqmm and one run earth wire of 6.00 sqmm
M&L flame proof, zone I & II, Gas Group II A/ II B, weather proof point wiring for one socket point controlled by one switch using approved colour coding as per IS with zero hologen flame retardent (HFFR) smoke free non toxic non corrosive PVC insulated unsheated flexible copper conductor cable 1.5 Sqmm (nominal area)single core 1100 volts grade in and including (ERW) stove enamelled condiuit heavy duty ISI marked duly welded, flame proof weather proof junction box, tee, bends, inspection bends etc all as required including PVC insulated unsheated flexible copper conductor cable 1.5 Sqmm (nominal area) single core 1100 volts grade as earth continuity conductor complete all as specified and directed.
M&Lflame proof, zone I & II, Gas Group II A/ II B, weather proof point wiring for one socket point controlled by one switch using approved colour coding as per IS with zero hologen flame retardent (HFFR) smoke free non toxic non corrosive PVC insulated unsheated flexible copper conductor cable 2.5 Sqmm (nominal area)single core 1100 volts grade in and including (ERW) stove enamelled condiuit heavy duty ISI marked duly welded, flame proof weather proof junction box, tee, bends, inspection bends etc all as required including PVC insulated unsheated flexible copper conductor cable 2.5 Sqmm (nominal area) single core 1100 volts grade as earth continuity conductor complete all as specified and directed.
All as per Srl item No. 34 above but 4.00 sqmm copper conductor and earth continuity.
Supply and fixing flame proof, Zone I & II, Gas Group II A/ II B, weather proof switch socket and plug combined in LM6 16A, 240 V, 2 pin and earth plug fully interlocked suitable for installation in hazardous as per IS-2147/62 aluminium alloy/cast iron neoprene gasket degree of protection IP 65 certified by CMRI complete all as specified and directed.
Supply & fix flame proof, Zone I & II, Gas Group II A/ II B, weather proof DB TPN 415 volts with busbar in cast aluminium LM-6 enclosure operated externally spring type knob complete with suitable incoming and outgoing cable entries with cable glands suitable for hazardous area and confirming to IS-2147/62 neoprene gasket degree of protection IP 65 suitable of following and all as specified and directed. Incoming (a) MCB SP 40 Amps - 01 No. Outgoing (b) MCB SP 6 to 32 Amps - 4 Nos
S&F in replacement LED light fitting 1x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistanttoughened glass with LED tube light fixtures driver, holders, connector etc. complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed.
S&F Exhaust fan of 305 mm flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant fixtures driver, connector etc. complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed.
S&F Wall Mounted fan of 305 mm flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant fixtures driver, connector etc. Complete with all accessoriesprewired and including connecting up with three core flexible copper conductor cable with suitable size. all as specified and directed.
S&F Switch flame proof rotary type ,CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with termination box in LM6, 16A, single pole 250V all as specified and directed.
M&L for complete earthing with galvanized steel earth plate electrode 60 cm x 60cm x 6 mm thick buried directly in ground ( Earth pit not less than 2.25 m below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized iron or steel pipe 40mm medium grade all as shown in electrical plate No 3 of SSR Part I connecting to earthing test point (earth test point to be provided at 5 mtr distance from earth pit) and testing on completion including necessary excavation and earth work by using galvanised iron wire 4 mm as earthing lead. The rate also include charcoal dust and salt in alternate layers 20mm dia medium grade GI watering pipe , funnel, wire mesh, concrete 1:3:6 type C-1 for pit and RCC pit cover PCC pit shall be provided 50 cm away from earth pit and not on the earth pit itself. The extra cost of the watering pipe, bends, elbows shall be included in the unit rate. Note : RCC pit cover shall be precast of RCC 1:2:4 type B-1 80 mm thick reinforced with XPM weighing not less than 4 Kg/ Sqm.
M&L for earthing complete with galvanized steel earth plate electrode 60 cm x 60cm x 6 mm thick buried directly in ground ( Earth pit not less than 2.25 m below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized iron or steel pipe 40mm medium grade all as shown in electrical plate No 3 of SSR Part I connecting to earthing test point (earth test point to be provided at 5 mtr distance from earth pit) and testing on completion including necessary excavation and earth work by using galvanised iron strip 32x6 mm as earthing lead. The rate also include charcoal dust and salt in alternate layers 20mm dia medium grade GI watering pipe , funnel, wire mesh, concrete 1:3:6 type C-1 for pit and RCC pit cover PCC pit shall be provided 50 cm away from earth pit and not on the earth pit itself. The extra cost of the watering pipe, bends, elbows shall be included in the unit rate. Note : RCC pit cover shall be precast of RCC 1:2:4 type B-1 80 mm thick reinforced with XPM weighing not less than 4 Kg/ Sqm.
Supply, laying and testing 10 sqmm 2 core size cable XLPE Insulated , screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor complete all as specified and directed.
All as per Sl item No 45 above but cable size 185 Sqmm 3.5 core
All as per Sl item No 45 above but cable size 35 Sqmm 3.5 core
S&F GI tubing 40mm bore, ''light grade', galvanised, with all fitting and laid in trenches or fixed to wall/Pole et complete all as specified and directed.
M&L for boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed.
Taking down copper/aluminium point wiring for (light, fan , socket or power and bell) complete including unserviceable fittings such as switches, ceiling rose, holders, sockets bell etc. and making good the distrubed surfaces on wall/floor etc complete all as specified and dirceted.
Dismantling of existing steel tublar pole of any size and setting aside for re- use and refixing the same within 50 metres complete all as specified and directed by Engr-in-Charge. Note:- Excavation and PCC work for refixing of Pole will be paid seperately under respective item of BOQ.
Dismantling & refixing the change over switch with all neccessary connection at location as directed by Engr-in-Charge complete.
Taking down and relaying the XLPE LT Cable 185x3.5 core into position with all neccessary connection as directed by Engr-in-Charge. Note : Excavation and earthwork shall be measured seperately under respective items of this BOQ. The old bricks retrieved from site will be re-used as cable protection after relaying cable.
Dismantling & refixing the juction box of any size with all neccessary connection at location as directed by Engr-in-Charge.
Exacavation in trenches not exeeding 1.5 m in depth and not exceeding 1.5 m wide and getting out soft and loose soil complete all as specified.
Returning, filling including spreading ,levelling, watering and well ramming in layers not exeeding 25 cm complete all as specified.
Removing excavated material not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified.
Material and labour for sand cushioning with a layer of sand 80 mm thick before laying of cable and 150 mm thick after laying of cable in trenches/ducts complete all as specified. Note: Punned down thicknes(overall 18 cm) shall be considered for measurement and payment.
Supplying and laying, factory made unreinforced precast concrete cable cover LV type-1, flat, of size 300X180x40mm, laid flat and dry in trenches over the cable for protection, length perpendicular to the direction of cable adjacent to each other, complete all as specified and directed.
M & L for PCC 1:2:4 type B0, using 12.5 mm stone aggregate for coping work including use of necessary formwork and finishing the exposed faces of concrete even and smooth using extra cement complete all as specified and directed by Engr-in-Charge..
M & L for PCC 1:3:6 type C2, using 40 mm stone aggregate for filling and mass concrete at defferent locations/ installation including finishing the exposed faces of concrete even and smooth using extra cement complete all as specified and directed by EIC.
M & L for PCC 1:4:8 type D2, using 40 mm stone aggregate for filling in foundations/mass fillings etc complete all as specified and directed by EIC.
S&FThunder stroke protector 60 (ESE) which is active lighting conductor designed to conform to the French Standard NFC 17 102:2011 T : 60 us for lightning conductors . Its working principle evolves from local electrostatic field that develops naturally around the system as a thunderstorm begins to gather in the event of descending lighting an inbuilt triggering device generates high tension pulses at conductor tip causing a corona -1 No complete all as specified and as follows :- (a) ESE Lighting Strike Counter Lighting Descharge counter self powered non re settale lighting event counter mounted on down conductor in IP 67 encloser with minimum sensivity 1 kA for 8/20 micro secocnd pluses -1 Nos (b) 5 meter supporting mast base plate incluiding all-02 Set (c) Test link for earth testing -01 Nos (d) 70 sqmm Single core PVC copper cable for down conductor-Upto 8 meter for Each (e) Copper Bondede with 250 Micromolecularly bonded eart pit consisting of 1 Nos 3 meter Earth with resistance improvement compound 2x25 Kg backfil coumpond in ROHS and Thermalstabilities tested -03 Set (f) Polypropylene earth pit cover-03 Nos
Material and labour, maintenance free earthing with copper earth plate electrode of size 600mmx600mmx6mm thick (or any shape) - 02 Nos, burried directly in ground vertically with top edge of earth plate(s) not less than 2.8m below normal ground level, placed apart in separate pits & interconnected with 25x3mm copper strip 1.5m long (Depth of earth pit not less than 3.70m below normal ground level) & 16mm dia solid copper rod 3.0m long with 250 micron copper coating, placed in centre vertically with top edge not less than 2.80m below normal ground level (Copper rod surronded with highly conductive and non-corrosive approved material) by boring a 6.10m hole with drill machine/auger of suitable bore, earth plate surronded from all sides by 15cm thick packed alternate layers of approved agricultural/cotton soil mixed with BACKFIL/AKAALTECH/JAMPLUS or any other equivalent earth/ground enhancing chemical compound/material approved by GE, as per IEEE80-2000 clause 14.5D, earthing system connected with 25x6mm thick copper strip by means of oxycetelane copper brazing as directed by Engineer-in-Charge,connector exposing 6" above ground level as for length resistance, earth lead protected with light grade GI Pipe 40mm bore (except exposing portion), & megger testing of the installation for desired results of resistance, complete all as specified and directed. Note (s):- (i) Earth resistance should be less than one Ohm. In case the test results are not found below one Ohm, complete earthing will be redone without any extra cost to Govt.
S&F gun metal test point terninal block of size 75 x 75 x 25 mm drilled and screwed inlcuding 3 Nos 8 mm dia 25 mm long hex head screw complete all as specified and directed.
M & L for earthing continuty conductor of main earthing lead fixed to wall on batten on recess or chases or buried in ground or down in conduit /pipe or fixed to poles or any other indicated situation for loop earthing etc. as required of size 32 x6 mm copper strip for net connection through LPDE pipe complete all as specified and directed.. Note: LPDE pipe & earth work shall be measered and paid seperately
M & L for 40 mm dia low density polyethylene pipe (LPDE) with all fitting of pressure rating 6 kg/Sqcm laid in trench for protection of earth strips for roof conductor for All Weather Ground Run Point complete all as specified and directed.
S&F flame proof, Zone I & II, Gas Group II A/ II B, weather proof DB SPN 230 volts 8 way with busbar in cast aluminium LM-6 enclosure operated externally spring type knob complete with suitable incoming and outgoing cable entries with cable glands suitable for hazardous area and confirming to IS-2147/62 neoprene gasket degree of protection IP 65 suitable for and including MCB SPN 40 Amp- 01 No (Incoming) and MCB SP 6-10 Amp -06 Nos (Outgoing) complete all as specified and directed.
S&F flame proof, Zone I & II, Gas Group II A/ II B, weather proof DB SPN 230 volts 4 way with busbar in cast aluminium LM-6 enclosure operated externally spring type knob complete with suitable incoming and outgoing cable entries with cable glands suitable for hazardous area and confirming to IS-2147/62 neoprene gasket degree of protection IP 65 suitable for and including MCB SPN 40 Amp- 01 No (Incoming) and MCB SP 6-10 Amp -02 Nos (Outgoing) complete all as specified and directed.
S&F flame proof, Zone I & II, Gas Group II A/ III B IP 65 Protection weather proof LED light fitting 2x16 watt, grey powder coated die-cast aluminium lamp housing, built in control gear, faceted anodised aluminium reflector heat resistant toughened clear glass with LED tube light fixture driver,holder, connector etc with necessary clamps, nuts and bolts complete with all accessories connecting elecrically using flexible flame proof end connectors omplete all as specified and directed.
S&F flame proof, Zone I & II, Gas Group II A/ III B IP 65 Protection weather proof exhaust fan 450 mm sweep with louvers , grey powder coated die-cast aluminium housing, connector etc with necessary clamps, nuts and bolts complete with all accessories connecting elecrically using flexible flame proof end connectors complete all as specified and directed.
M/S SANGA SINGH AND CO
BEHL AND COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .