Garrison Engineer Army Trivansrum
Office of Garrison Engineer Army, Thirumala Post, Trivandrum-695006
REPAIR AND REPLACEMENT OF OLD UNSERVICEABLE STREET/ FLOOD LIGHT FITTINGS AND CONNECTED ITEMS AT OTM AND MD ACCN OF CANNANORE AND CALICUT AREA UNDER GE (ARMY) TRIVANDRUM
2026_MES_799431_1
8421/E8
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
Kannur
As per tender document
8 documents required · 8 mandatory
₹500
GE Army Trivandrum
₹44,900
Yes
19 Nov 2026
19 Nov 2026
9 Dec 2026
19 Nov 2026
7 Dec 2026
2 Dec 2026
19 Nov 2026 - 25 Nov 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply and fixing brackets for street light fitting made of 40/ 32 mm bore Gl pipe light grade 1.5m long bent to shape with flat iron clamps 25 x 3 mm thick, two nos. with nuts, bolts and applying two coats of aluminium painting over one coat of primer including taking down unservicable brackets complete all as specified and as directed. | 48 | Each | - | - |
| 2 | Checking of street light fittings any type on pole/ wall to find out defect/ taking out unservicable parts such as driver and repairing by changing the defective parts including minor repairs to cable connection/ loose connection/ necessary cleaning the perpex cover where provided and testing complete all as specified and as directed by Engineer-in-Charge.
Note: (i) Spares of light fittings shall be measured and paid separately.
(ii) The T&P vehicles and necessry ladders etc. shall be arranged by the contractor and the cost is deemed to be included in the quoted rates. | 45 | Each Job | - | - |
| 3 | S&F in replacement PVC wiring for circuit/ submain wiring alongwith earth wire with 2 x 1.5 sqmm sizes of FRLS PVC insulated copper conductor, single core cable in surface/ pole recessed as required for connection for street light fitting with overhead lines/ service connection including taking out old aluminium cable complete all as specified and as directed by Engineer-in-charge. | 490 | Running Metre | - | - |
| 4 | S&F in replacement of integral LED street light luminaires complete comprising of epoxy powder coated housing, enclosed with glass cover in front, 35 Watts mounted on MCPCB suitable for 50mm dia pipe ingress protection IP-66 complete all as specified and as directed. | 48 | Each | - | - |
| 5 | S&F in replacement of integral LED street light luminaires complete comprising of epoxy powder coated housing, enclosed with glass cover in front, 60 Watts mounted on MCPCB suitable for 50mm dia pipe ingress protection IP-66 complete all as specified and as directed. | 24 | Each | - | - |
| 6 | S&F in replacement of LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant with driver and lamp complete all as specified and as directed. | 11 | Each | - | - |
| 7 | S&F in replacement of integral LED street light luminaires complete comprising of epoxy powder coated housing, enclosed with glass cover in front 45 Watts mounted on MCPCB suitable for 50mm dia pipe ingress protection IP-66 complete all as specified and as directed.
Make: Cat part No. BCLST 30W LED of Bajaj or equivalent in makes as specified in list of manufacturers and as approved by GE. | 19 | Each | - | - |
| 8 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes etc. not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in soft/ loose soil complete all as specified and directed. | 105 | Cubic Metre | - | - |
| 9 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of pipes etc. not exceeding 10 sqm on plan and getting out in soft/ disintegrated rock complete all as specified and directed. | 25 | Cubic Metre | - | - |
| 10 | Excavation in trenches not exceeding 1.5 m wide and exceeding 1.5 m in depth and not exceeding 3 m in depth; for foundation for erection of poles, stays, laying cables, stays etc. not exceeding 10 sqm on plan and getting out in soft/ disintegrated rock complete all as specified and directed. | 0.5 | Cubic Metre | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.25 MB
8421Tender.pdf
Tender Documents • 0.46 MB
BOQ_896930.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .