Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹24.2 L
EMD Value
₹24,186
Closing Date
14 Sept 2023, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
NBCC Bhawan
NBCC Bhawan
CAMC of Access control system, visitor management, Integration of Fire Alarm system with access control system, CAMC for Boom barriers system & RFID installed at CBI HQ, CGO Complex , New Delhi.
NSL/CEO/CBI/NIT/2023/602~EW541c8a50b6dae954dcd22d3d
NSL/CEO/CBI/NIT/2023/602
Open Tender-Domestic
Miscellaneous
NBCC Bhawan
₹2,950
₹24,186
14 Sept 2023
6 Sept 2023
14 Sept 2023
6 Sept 2023
14 Sept 2023
Bill Of Quantity ( BOQ)
Name of work:- CAMC of Access control system, visitor management, Integration of Fire Alarm system with access control system, CAMC for
Boom barriers system & RFID installed at CBI HQ, CGO Complex , New Delhi.
Sr. No. DSR/NS Description Unit Qty. Rate Amount
Part -1 :- CAMC works
CAMC for access control system having a items:- Proximity Card Reader,Door Access Controller
(2 Door & 4 Reader Support, with enclosure cabinet),Em Lock 600 LBS (Single Leaf Door),Em
Lock 1200 LBS (Double Leaf Door),Exit Push Button,U/L Bracket,Power Supply 12V 5 Amp,08
Port Gigabit Network Switch,Dell R240-1U Rack 1P SERVER Hardware,Window Server 2019
Standard OS, 24" Inch TFT Slim Monitor,WinPack 4.0 Access Control Software ,Eontime
Attendance Software ,UTP Cat-6 Cable,PVC Conduit Pipe with Fixing Accessories etc. complete
in all respesct or as directed by engineer-in-charge. (Complete items details are enclosed as
annexure-1, Technical specification)
CAMC for visitor management system having a items :- Visitor Management Application
Software-Window based application, SQL data base, data storage for more than 1 year, Desktop
PC-I-5/ 8th Gen/8GB RAM/1TB HDD/500GB SDD/Win10Pro/19 inch TFT,Tripod Turnstile System
with all required accessories and civil work,HID I-class Reader,2 Door Access Controller,USB
based QR Code Reader,Iclass Card Encoder USB based,Web cam,Cat-6 Cable, Conduit Pipe with
other consumable accessories,Drop Box for cards with lock and key etc complete in all respect
or as directed by engineer-in-charge.(Complete items details are enclosed as annexure-2,
Technical specification)
CAMC of Boom barrier system having a items :- Boom Barrier of length 4 mtr for Vehicle Main
Entry-Exit to integrate along with existing RFID system at site Application-Outdoor IP Rating-IP-
56, Housing Dimension-Modular,Housing Material of Construction -Mild Steel Housing with
Base frame in SS-304 for high protec- tion against corrosion. Protection-All Housing and internal
parts will be rust & corrosion free metals or alloys of high strength with suitable Epoxy coating
as applicable. Epoxy zinc anti-cor- rosion treatment 100 microns + paint,Housing Dimension
(WxDxH)- 469x279x1100 mm,Boom Specification-Boom should be round or elliptical with led
lights &rubber bumper,Intelligence- The barrier shall use a Hydraulic Drive in combination with
microprocessor based control card communication standard interfaced Controller,Loop
Detector- Inbuilt Dual Loop Channel Detector Compliance & Safety - Compliance to CE Ad-
herence to Safety Requirements of the EMC Directive 2014/30/EU, Directive ROHS 2
2011/65/EU andThe basic requirements of the Machinery Directive 2006/42/EC,Power Supply -
230+/- 10% VAC, 50 Hz. Electric Motor-36vdc Brushless,Push Button,Boom Rest,Pair of
Photocell Safebeam,CAT 6 UTP Armoured cable 23 AWG solid copper conductors,8 Core x 1.0 sq
mm multi strand, copper, unarmoured shielded Cable as per specification (between the every
card readers & the access controllers),4 Core x 10 Sq mm Aluminium cable for power to Boom
Barrier & UHF Reader & Raw Power Supply,Pole of 2 Mtr. Height suitable to mount RFID with
grounting 1 feet Excavation in all types of soil, casting of civil foundation & grouting of
foundation bolts, its curing, back filling & making the surface good and cleaning etc., Client work
Station -a) Intel Core i7 processors @ 3.6 GHz or latest with minimum 8 MB cache memory.b)
Memory: Minimum 8 GB RAM of latest technology.,c) HDD: Minimum 1 TB SATA drive.,d) N/W
Card: PCI Gigabit Ethernet card supporting 100/1000 Mbps LAN-Two cards -2 x 1G LAN Port etc .
complete in all respect or as directed by engineer-in-charge. (Complete items details are
enclosed as annexure-3, Technical specification)
CAMC of RFID system having a items :- Long Range UHF Reader with a read range of 12 meters
as for Boom Barriers. Shall support both weigend and RS-232 communication proto-col, IP
controller for UHF reader shall support RS-232 protocol to read multiple tags as a time. Shall
support 2 readers and read fast tags. With power supply and enclosure, Support 10000 user
4 NS credentials & 50000 transaction buffer,Integrated Vehicle Access Management soft- ware month 12 13619.17 163430.00
application (VAM). Shall support multi-tenant configuration facility, multi gate
management,ASSAFLEX RFID TAGS for Cars/two wheelers complete in all respect or as directed
by engineer-in-charge. (Complete items details are enclosed as annexure-4, Technical
Part -2 :- Integration of fire Alarm system with access control system
Supplying, Installation, Testing & Commissioning of Person Machine Interface(PMI-2) is the user
interface for the fire alarm system from PMI-2 operator can acknowledge events, control &
reset the system.Detailed information about the nature & location of events can also be
displayed complete in all respect or as directed by engineer-in-charge.
Supplying, Installation, Testing & Commissioning of Globe Person Machine Interface(PMI-2) is
the user interface of 2 or more PMI for the fire alarm system in a building from where operator
2 NS can acknowledge all the events, control & reset the system. Detailed information about the Lot 1 200600.00 200600.00
nature & location of events can also be displayed complete in all respect or as directed by
engineer-in-charge.
Supplying, Installation, Testing & Commissioning of Network Interface card provides network
3 NS communication between enclosures. complete in all respect or as directed by engineer-in- Nos 2 60416.00 120832.00
Digitally signed by AMIT
Bill Of Quantity ( BOQ)
Name of work:- CAMC of Access control system, visitor management, Integration of Fire Alarm system with access control system, CAMC for
Boom barriers system & RFID installed at CBI HQ, CGO Complex , New Delhi.
Sr. No. DSR/NS Description Unit Qty. Rate Amount
Supplying, Installation, Testing & Commissioning of 24V DC Relay contact will be used when an
4 NS FAS event occurs that controls the Access Electric Door Lock complete in all respect or as Nos 40 886.00 35440.00
directed by engineer-in-charge.
Supplying, Installation, Testing & Commissioning of Power Supply of 24V DC 10 AMP for FAS
complete in all respect or as directed by engineer-in-charge.
Supplying, Installation, Testing & Commissioning of Single input interface module with relay (
complete in all respect or as directed by engineer-in-charge.
Supplying, Laying & Drawing of 2 Core 1.5 SQMM Armoured FRLS Copper Cable of approved
make complete in all respect or as directed by engineer-in-charge.
Digitally signed by AMIT
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.06 MB
NIT CBI.pdf
Tender Document
SCC CAMC CBI.pdf
Tender Document
GCC upto amend6.pdf
Tender Document
Instruction to Bidder for online Bid Submission.pdf
Tender Document
Forms.pdf
Tender Document
equipment make.pdf
Tender Document
BoQ CBI.pdf
Tender Document
corrigendum-1896-corrigendum -I.pdf
pdf • 0.88 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .