Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.5 LAccepted-Finance | L1 | Accepted-Finance Lowest Bidder | |
| 2 | L2₹9.7 L+₹21,030 (2.22%)Rejected-Finance P O DHAP DHAPI MALLICKPUR P S BARUIPUR 24PGS S PIN 743387 | 24 PARAGANAS SOUTH | WEST BENGAL | 743387 | L2 | Rejected-Finance Higher Bid | |
| 3 | L3₹10.9 L+₹1.4 L (14.7%)Rejected-Finance 33 PEMANTLE STREET KOLKATA 700016 | KOLKATA | KOLKATA | WEST BENGAL | 700016 | L3 | Rejected-Finance Higher Bid | |
| 4 | Rejected-Technical 86 TOLLYGUNGE CIRCULAR ROAD KOLKATA WEST BENGAL 700053 | KOLKATA | KOLKATA | WEST BENGAL | 700053 | - | Rejected-Technical Documents are not in order. | |
| 5 | Rejected-Technical 12 HAJI MD MOHASIN SQUARE KOL 700016 | KOLKATA | KOLKATA | WEST BENGAL | 700016 | - | Rejected-Technical Documents are not in order. |
Tender Value
Refer Docs
EMD Value
₹21,166
Closing Date
2 Jul 2025, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE, South 24 Parganas Electrical Division
57/2 Diamond Harbour Road, Kolkata - 700 023
SITC of AC machine and allied EI work at Caning Sub-Divisional Hospital,Canning ,South -24 Parganas.
2025_WBPWD_863960_1
WBPWD/EE/S24PED/eNIT20/2025-26
Open Tender
ELECTRICAL WORKS ORG
Item Rate
30 days
Canning
Please refer Tender documents.
4 documents required · 4 mandatory
₹21,166
South 24 Parganas Electrical Division
22 Jul 2025
13 Jun 2025
4 Jul 2025
13 Jun 2025
2 Jul 2025
20 Jun 2025
19 Jun 2025
Amount
Supply & Delivery of High-wall Split-type Air-Conditioner having following specification: Cooling Capacity - 6.5 kW (Minimum) Minimum ISEER - 3.8, BEE level - 3-Star(min)[1st July22 to 31st December 2025] IS Compliance - IS-1391(Part-I & Part-II) with all amendment Refrigerant - R410A/R32 Compressor - Rotary/Scroll Evaporator & Condenser Coil - Copper Operating outdoor temperature - 48ºC and above Air Flow: 800 CFM (Minimum) Power supply -230V, 50Hz (±tolerance asper applicable standard),as directed by EIC. The scope of work is also includes supply and fixing of the following: (i) Necessary refrigeration copper line with nitrile rubber insulation and wrapping tape - 3 mtr (ii) Necessary 3/4 core copper cable (FRLS type - make : Finolex/RR Kable/Polycab/Havells/Gloster) - 3mtr and 230V, 25A, 3pin plug top with indicator (Anchor/North West/Legrand/Havells) [Make: General/Daikin/Mitsubishi Electric/Blue Star/Voltas/Carrier]
Supply & Delivery of High-wall Split-type Air-Conditioner having following specification: Cooling Capacity - 5.0 kW (Minimum) , Minimum ISEER - 3.8, BEE level - 3-Star(min)[1st July22 to 31st December 2025] IS Compliance - IS-1391 (Part-I & Part-II) with all amendment Refrigerant - R410A/R32 Compressor - Rotary/Scroll Evaporator & Condenser Coil - Copper Operating outdoor temperature - 48ºC and above Air Flow Rate: 600 CFM (Minimum) Power supply - 230V, 50Hz (±tolerance as per applicable standard), as directed by EIC. i) Necessary refrigeration copper line with nitrile rubber insulation and wrapping tape - 3mtr. ii) Necessary 3/4 core copper cable (FRLS type - make : Finolex/RR Kable/Polycab/Havells/Gloster) - 3mtr and suitable plug top(Anchor/North West/Legrand/Havells) [Make: General/Daikin/Mitsubishi Electric/Blue Star/Voltas/Carrier]
Installation, Testing & Commissioning of Indoor & Outdoor unit of above Hi wall split AC machine after making hole in wall etc as per Direction of EIC including Supply of required Refrigerant, S&F of necessary suitable fixing arrangement for indoor and outdoor unit as recomended by Manufacturer, laying and making connection of refrigeration pipe, power cable, drain pipe etc and mendingn good the damages as per direction of the EIC.
S&F of additional following items for length exceeding 3 mtr for complete installation and commissioning of above AC machines. (i) Supply & Fixing of extra refrigerant pipe (as requisite dia) with nitrile rubber insulation and wrapping tape [each mtr Refrigerent pipe will include cost of 1 metre liquid pipe line and 1 mtr gas pipe line of required dia and other accesories as required].
S&F of additional following items for length exceeding 3 mtr for complete installation and commissioning of aboove AC machines. i) 2.5 sqmm, 3/4 core copper cable (FRLS type - make : Finolex/RR Kable/Polycab/Havells/Gloster)
Supply & laying Soft Drawn PVC Drain Pipe 19mm dia with proper supports & brackets as per direction EIC. (Make: Suprime/Oriplast/Finolex)
Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works :-
i) 20mm size
ii) 25mm size
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire of the following sizes in the 19mm/25mm prelaid polythene pipe/PVC rigid conduit as per GS. a) 2x(4 sqmm)+1x (2.5 sqmm) for Ac cnnection
S & F solderless Copper socket by crimping of Copper wires. a) 2x(4 sqmm)+1x (2.5 sqmm)
Supplying & Fixing GI inspection box (16 SWG) of the following sizes(in mm ) flushed in wall & 3 mm thick bakellite cover as per GS
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS [Make-Legrand) as per direction of EIC. ] , 6-32 SP
S&F of 250V double door Timer DB [equivalent of 2+8 way SPNDB] with sheet steel enclosure, pnosphitised powder coated neutral bar, DIN rail with IP-43 potection comprising with 1 no. 25A DPMCB ('C' curve 10KA), 2 no. 16A SPMCB ('C' curve 10KA), 1no. Programmable time switch-24 hrs with minimum switching of 15 minutes and 1 no. 18A/25A 2-Pole power contractor with inner-outer plate & internal wiring by suitable size of cu. wire incl. 1 no. Auto-Manual bypass toggle switch and provision for earthing attachment, incl. LED indication light for running condition with mechanical locking arrangement, as directed by EIC. [Make-ABB/L&T/Crabtree]
Note: 1. The Agency must procure the materials from the manufacture / OEM or from their authorised sales channel so that the standard warranty/support of the manufacture / OEM becomes applicable to the products to be delivered and installed by them. 2. Documents that authenticates such procurement from the manufacture / OEM or from their authorised sales channel and standard warranty/support should be sent from the e-mail of the manufacture / OEM / authorised sales channel to the e-mail of Engineer-in-charge and hard copy of it to be submitted during execution of work/submission of Bill. 3. If any refurbished material is supplied and installed, Penal action will be will be taken as per existing rules. 4. All the above rates should be quoted inclusive of all taxes, duties and all ancilery charges with cost of maintenance, servicing, supply & replacement of spares for 1 (One) year from the date of commissioning. 5. Total is rounded off to the nearest rupees.
PUSPA ELECTRIC (BID ID -6613145)
MILLENNIUM AIRCON (BID ID -6614891)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .