Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.7 LAccepted-AOC PMC 24 528 GROUND FLOOR NEAR PAYYANUR SERVICE CO OP BANK KOTTY BRANCH PAYANNUR KANNUR KERALA 670307 | PAYYANUR | KANNUR | KERALA | 670307 | L1 | Accepted-AOC Lowest bid | |
| 2 | L2₹30.0 L+₹91,314.25 (3.14%)Rejected-Finance THEKKEKOTTARAM RAMANTHALI PO KANNUR DIST KERALA 670 308 | RAMANTHALI | KANNUR | KERALA | 670308 | L2 | Rejected-Finance Higher bid value | |
| 3 | L3₹33.8 L+₹4.7 L (16.1%)Rejected-Finance DOOR NO IV 400 NEAR RAMANTHALI GHSS RAMANTHALI PO KANNUR 670308 | KANNUR | KERALA | 670308 | L3 | Rejected-Finance Higher bid value |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
2 Dec 2019, 6:00 pmClosed
GE MAINT EZHIMALA
GARRISON ENGINEER (MAINT) MILITARY ENGINEER SERVICES INDIAN NAVAL ACADEMY POST KANNUR DIST KERALA
PROVN OF DEFICIENT WATER TANKS SAILORS INLIVING BLOCKS, SPL REPAIRS TO ROOF/CEILING OF FIRE STATION, SPL REPAIRS TO CERA QTR NO. 311 AND PROVN OF MONOBLOCK PUMP SET ETC UNDER B/R II(MAINT) AND E/M (MAINT) AT INA EZHIMALA
2019_MES_295784_1
GE MAINT EZHIMALA 8272 E8
Open Tender
Civil Works
Item Rate
270 days
EZHIMALA
As per NIT
7 documents required · 7 mandatory
₹500
Yes
GE MAINT EZHIMALA
₹50,000
Yes
3 Jan 2020
7 Nov 2019
4 Dec 2019
7 Nov 2019
2 Dec 2019
22 Nov 2019
8 Nov 2019 - 21 Nov 2019
Amount
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in hard /dense soil complete as specified and directed.
M&L for hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete as specified and directed.
M&L for PCC 1:4:8 type D2 (40 mm graded aggregate) as in foundation complete as specified and directed.
M&L for PCC 1:2:4 concrete type B1 (20mm graded aggregate) 150mm thick in floor complete as specified and directed
M&L for pre-cast cement concrete block in cement concrete masonry 1:3:6 type B-1 ( using 20 mm graded stone aggregate)with solid blocks, exc. 10 cm in width and setting in cement mortar 1:6,complete as specified and directed.
M&L for 15 mm thick rendering on fair faces of brick work or concrete surfaces in cement mortar 1:6 surfaces finished even and smooth complete as specified and directed.
M&L for Glazed ceramic tiles 7 to 8 mm thick (Square/ rectangular) area of each tile exc 0.06 sqm but n. exc. 0.11 sqm on vertical surfaces such as skirting dados etc set and jointed in neat cement paste and pointed in white or coloured cement to match including 10mm thick screed on fair faces of brick work or concrte surfaces in Cm 1:4 finished even and fair complete as specified and directed.
M&L for Non Skid coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed or bedding layer of cement mortar 1:6, 20mm thick for laying floor finishes complete as specified and directed
S&F Rotational moulded polythene ISI Marked water storage tanks 10000 ltrs capacity (cylindrical vertical with closed top) hoisted and fixed in position complete as specified and directed
S&F Rotational moulded polythene ISI Marked water storage tanks 5000 ltrs capacity (cylindrical vertical with closed top) hoisted and fixed in position complete as specified and directed
S&F Rotational moulded polythene ISI Marked water storage tanks 2000 ltrs capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified including Dismantling water tanks and removing to store complete as specified and directed
S&F 32mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings conseled on walls/ceiling or laying in floors complete as specified and directed.
S&F 25mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings conseled on walls/ceiling or laying in floors complete as specified and directed
S&F 20mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings conseled on walls/ceiling or laying in floors complete as specified and directed
S&F 15mm bore chromium plated bib taps (fancy type) long body, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipes complete as specified and directed
S&F 40 mm bore ball brass valves, high pressure, with polyethylene float and fly nut complete, screwed for iron pipe or brass ferrule and fixed complete as specified and directed
S&F in repair 32 mm PP-R Gate valves (brass insert) as per requirement of the site complete as specified and directed
S&F in repair Grating doom 100mm dia of PTMT (Minimum weight 25gms) complete as specified and directed
S&F 75 mm bore PVC (SWR) bends any radius complete as specified and directed
S&F, PVC (SWR) bends 110mm dia any radius (Work in foul condition and in shaft) complete as specified and directed
S&F, 75mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or floor (Work in foul condition and in shaft) complete as specified and directed
S&F, 110mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or floor (Work in foul condition and in shaft) complete as specified and directed
M & L Cutting into existing manholes for connecting new drains 150 mm dia, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required. (Work in foul condition and in shaft) complete as specified and directed
Dismantling plain or corrugated steel sheeting / galvalume sheets, any gauge, thickness as in roof covering complete as specified and directed.
M&L For Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm Mangalore tile pattern of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete as specified and directed
M&L For Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete as specified and directed
Dismantling wrought iron or mild steel work of any description complete as specified and directed.
S&F steel work in tubular trusses (circular & Rectangular) and including shaped washer etc. complete using ERW or induction butt welded tubes. conforming to IS 1161-1998 grade St-240 for round tubes and conforming to IS 4923-1968 Grade St-240 for square or rectangular tube complete as specified and directed
M&L flat iron wind tie for fixing to galvalume corrugated sheetings complete as specified and directed.
S&F Plates (plain or chequered) channels. Square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment (Fe-410W, Gde E-165, Qlty-A) complete as specified and directed.
M & L for Pre-cast cement concrete block masonry with solid blocks type C1, 1:3:6(20mm graded aggregate), exc. 10 cm in width and setting in mortar CM 1:6, complete as specified and directed.
M&L for sealing of screw holes in roofing sheets with PU sealent of Make : Forsroc, McCoy Soudal or equivalent including cleaning of existing surfaces complete as specified and directed.
M&L for Laying and pasting of Bituminous strip of width 10 cm of Make : 3M, BASF, Dr.Fixit, Forsroc or equivalent on joints of galvalume sheet & RCC surfaces including cleaning of existing surfaces complete as specified and directed.
M&L for Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 with WPC complete as specified and directed.
Taking down cement plaster on bricks or stone walls including raking out joints hacking for key scrubbing down with water etc complete as specified and directed.
M&L for rendering 15mm thick on Exterior surface of brick work or concrete surfaces or wall surface in cement mortar 1:4 and finish the surface even and smooth with WPC complete as specified and directed.
M&L for rendering 10mm thick on interior surface of brick work or concrete surfaces or wall surface in cement mortar 1:6 and finish the surface even and smooth with WPC complete as specified and directed. Note: Supply only water proofing compound shall be measured and paid separately
Supply only Integral waterproofing compound complete as specified and directed.
M&L for newly plastered surfaces of wall and applying two coats of Distempering walls with distemper oil emulsion complete as specified and directed.
M&L for preperation of new plastered surfaces and applying two coat of acrylic emulsion paint (exterior grade) on wall over a coat of acrylic primer all as specified and as per manufacturers instructions complete as specified and directed.
M&L for old plastered surfaces of wall and applying one coats of Distempering walls with distemper oil emulsion complete as specified and directed.
M&L for Preparation of old plastered surfaces and applying one coats of sandtex mat on wall all as specified and as per manufacturers instructions all as specified and directed by Engineer-in-Charge complete as specified and directed.
M&L For Sealent filling to window/door frame - The work shall include the following :- (a) Cleaning existng treatment like cement mortar and sealent filled between window / door frame and the masonery walls to be completely removed and all the loose adhered particles shall cleaned using air blowers and allowed it to dry. (b) The sealent filling shall be flexible with one part low modulus gun grade elastomeric Polyurethane sealent Nitroseal PU 40 of Fosroc of BASF or Sika of pidilite or approved equivalent to the joints size max of 10 mm width X 10 mm depth. The cured sealent shall have the prperties of MAF 25%, UV Resistance, and service temperature range -40 Degree Centigarde to 70 Degree Centigrade, Nitoseal PU 40 confirms to the standatad compliance of ISO11600:2002 Type F 25 LM, ASTMC920-95 Type S,Grade NS,Class 25. The rate quoted shall include all material, surface preparation, tools scaffoldings, safety equipments, skilled laboures etc complete as per Manufactures specification.
M&L for Preparation of new steel surfaces of any description n exc 10 cm in width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete as specified and directed.
M&L for Preparation of new steel surfaces of any description over 10 cm in width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete as specified and directed.
Dismantling Wall and false ceiling boards including all fittings (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete as specified and directed
M&L for Hangers 6mm dia. G I (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long complete as specified and directed.
S&F anodized aluminium snap grid frame work for false ceiling (size of grid 605x605mm) complete as specified and directed.
M&L for Non asbestos fiber cement building board 4mm thick fixed in ceiling flat or sloping complete as specified and directed
Dismantling single layer of Mangalore pattern tiles in roofing complete as specified and as directed.
Dismantling cabinets boarding, any description, fixed in any position with Screws complete as specified and as directed.
Taking down Chowkhats or frames exc. 1.5 sq. m but not exc. 4 sq. m each, with shutters (without taking off shutters from the frames) complete as specified and as directed.
Taking down Chowkhats or frames not exc. 1.5 sq. m each, with shutters (without taking off shutters from the frames) complete as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete as specified and directed.
S & F Anodised aluminium frame for roofing tiles with one or more rebates including joining cleat for fixing etc complete as specified.
M&L for roof tiles Mangalore pattern interlocking at side joints, laid dry complete as specified and directed
All as per item No 56 here above but except tiles complete as specified and as directed.
M&L for ridge or hip tiles to suit Mangalore pattern or roofing tiles bedded and jointed in cement mortar 1:6 complete as specified and as directed.
M&L for preparation of new MP roof tile surfaces by cleaning the tiles and applying two coats of antifungal paint using UNIGLOSS deluxe multi surface paint over a coat of primer complete as specified and as directed
M&L for preparation of old MP roof tile surfaces by cleaning the tiles and applying one coats of antifungal paint using UNIGLOSS deluxe multi surface paint complete as specified and as directed.
M&L for 12mm thick Perforated particle board/ tiles for insulation and acoustic purposes, 60x60 cm in size, fixed with nails to timber frameworkorwith staples on snap grid complete as specified and as directed.
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete as specified and directed.
S & F Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing (With Particle Board Core) complete as specified and directed.
S & F powder coated Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete as specified and directed.
S & F powder coated Anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete as specified and directed.
S&F Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane - 4mm thickness complete as specified and directed.
S&F Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete as specified and directed.
S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete as specified and directed.
Taking down Shutters of any description exc 1 sq. m but n exc 2 sq. m each complete as specified and directed.
S&F Plain framed, panelled shutter (two panel) with lock rail and panel of 9mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated - 2nd class HW rail & style - Thickness of shutter 35mm. complete as specified and directed.
M&L for Machine cut cudappah stone slab 20-25mm thick over cement screed base, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete as specified and directed.
M&L for Screed bed or bedding layer of mortar 20 mm thick for laying floor finishes with Cement plaster 1:6 complete as specified and directed.
Cutting out cracks to V-section in existing roofs/terracing/walls, cleaning out, wetting, grouting with cement and sand slurry 1:3 including water proofing compound with Staging to work in high altitude etc. complete as specified and directed. Note: Supply only water proofing compound shall be measured and paid separately
M&L, 15mm thick rendering in CM 1:4 on fair faces of brick work or concrete surfaces with liquid water proofing compound, surface finished even and fair, complete as specified and directed. Note: Supply only water proofing compound shall be measured and paid separately
M&L for 10mm thick rendering in CM 1:3 on ceiling surfaces finished even and smooth without using extra cement, complete as specified and directed.
M & L for applying two coat of polyurethane liquid or silicone based water repellant repellin WR of Pedilite or equivalent for water proofing treatment before plastering on walls complete as specified and directed
M&L, preparation of new plastered surfaces and applying two coats of acrylic emulsion (exterior grade) over a coat of primer on wall all as specified and as per manufacturers instructions .Note :- The rates including necessary scaffoldings and safety measures for safe doing of work at heights
M&L, preparation of new plastered surfaces and applying one coat of acrylic emulsion (exterior grade) on wall all as specified and as per manufacturers instructions. Note :- The rates including necessary scaffoldings and safety measures for safe doing of work at heights
M&L applying three coat of white wash on ceiling including preperation complete as specified and directed.
M&L applying of two coat of OBD emulsion over a coat of primer on newly plastered surface including preperation complete as specified and directed.
M&L applying of one coat of OBD emulsion over old painted surface including preperation complete as specified and directed.
M&L applying of one coat of white wash on ceiling including preperation complete as specified and directed.
M&L applying two coats of synthetic enamel paint over a coat of primer including preperation on wooden surface complete as specified and directed.
M&L Surfaces of any description, over 10cm in width or girth,not otherwise described applying one coats of synthetic enamel paint over old wooden surface including preperation complete as specified and directed.
M&L Surfaces of any description, over 10cm in width or girth,not otherwise described applying one coats of synthetic enamel paint over old steel surface including preperation complete as specified and directed.
S&F 10 mm thick PVC used as in cupboard/cabinet fixed with screws to wall as required size and shape complete as specified and directed.
S & F 10 mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing.complete as specified and directed.
S&F Double action spring hinges of size 100 mm, brass with phosphore bronze wire spring bright polished complete as specified and directed.
Ball catches with 8mm dia steel ball, and brass body and striking plate including letting in and fixed complete as specified and directed.
S&F 75 mm size extruded brass handles,fabricated type polished complete as specified and directed.
S&F Aluminium handles, cast type, anodised handle of size 100mm complete as specified and directed.
S&F Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 of size 100mm complete as specified and directed.
S&F Aluminium anodised, barrel tower bolts of extruded section and fixed of Length 200mm complete as specified and directed.
S&F Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed of Length 300mm complete as specified and directed.
S&F Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor - Overall length of cover plate 140mm complete as specified and directed.
M&L for cement concrete 1:2:4, type B1 (20mm graded stone aggregate) as in filling and mass concrete, roof slab padding preparatory to roof treatment, complete as specified and directed.
Taking down existing water proofing treatment of any description and removal rubbish off the premises,complete as specified and directed.
M&L, applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 Kg per Sqm including cleaning surface for laying APP based polymeric membrane minimum weighing 4kg/sqm and minimum 4mm thick reinforced with polyester non woven fabric (wt not less than 160 gms/sqm) by forced application complete as specified and directed.
Supply and Lay Galvanized pipe of "Medium Grade" with all fittings laid in trenches/walls/floors of size 40mm (1.5") dia. complete as specified and directed.
Supply and Lay Galvanized pipe of "Medium Grade" with all fittings laid in trenches/walls/floors of size 25mm (1") dia. complete as specified and directed.
Supply and fix Gun Metal gate valves, with iron wheel head, screwed both ends for iron pipe and fixed to size 40mm (1.5") dia. complete as specified and directed.
Supply and fix Gun Metal gate valves, with iron wheel head, screwed both ends for iron pipe and fixed to size 25mm (1") dia. complete as specified and directed.
Supply and fix Monoblock Pump Set suitable for 230 Volts, single phase system having capacity of 1 HP with MCB 10 amps DP enclosures with single core wire 1.5 Sqmm of length 100 RM complete as specified and directed.
M&L for Cement concrete base type B-2 (1:2:4) (40mm Graded aggregate) for water tank complete as specified and directed.
Taking down carefully copper/ aluminium point wiring (light, fan and power socket etc) complete (except concealed conduit) including fittings such as switches ceiling roses, pendent, regulators, sockets, earth plug and socket etc and making good matching to the existing colour to the disturbed surface complete as specified and directed.
M&L colour code point wiring FR PVC insulated and unsheathed cable with 1.5 sqmm copper conductor single core multistandred 1100 volt grade conforming to IS 694 drawn throughexisting PVC conduit with suitable size GI flush box fitted with modular cover plate with frame (inner/ outer plate) for mounting 6 Amps switch with socket on independent board including FR 1.5 sqmm earth wire copper insulated wire connected to common earth dolly including making good the existing disturbed surface using wall putty and matching colour emulsion paint all directed at the site complete as specified and directed for the following:-
One Light/ fan point controlled by one switch.
One 3 pin socket outlet outlet 5 Amps on the same board with other switches
5 Amps socket point on independent board Note : Size of copper earth wire must be equal to size of current carrying conductor upto size 16 sqmm
All as per item no 106 here in above but 2.5 sqmm for 15 Amps socket on indipendent board.
M&L sub main wiring using 2 runs of 4 sq mm FR PVC insulated cupper conductor 1100 Volts grade conforming to IS specification drawn through and including PVC casing caping along with 1 run of 4 sq mm PVC insulated copper conductor FR cable as earth lead connected to common earth dolly complete all as specified, including takingdown the unserviceable wiring complete as specified and directed. Note:- 2 runs of 4 sqmm PVC insulated copper conductor plus 1 run of 4 sqmm PVC insulated copper conductor earth cable plus one run of casing/caping will be measured as one unit.
Supply and fix switch, piano, flush mounting type, single pole, one AC 230V grade 5 Amps. complete as specified and as directed.
All as per item No. 112 here in above but 15 Amp complete as specified and directed.
Supply and fix socket outlet 3 pin 5 amp complete as specified and directed
Supply and fix socket outlet 3 pin15 amp complete as specified and as directed.
Supply and fix fan regulator electronic step up type type 100/120 Watt AC 230 watts complete as specified and as directed.
Supply and Fix ceiling rose 3 pole 240V PVC/Poly carbonate insulated body complete as specified and as directed.
Supply and fixin repair MCB single pole AC 240 Volts, 6 to32 Amps complete as specified and as directed.
Supply and fix in repair MCB SPN, 40 Amps, 415 Volts AC complete as specified and as directed.
Supply and fix in repair RCCBs for earth leakage protection double pole 30 mA, 40 Amps complete as specified and as directed.
Supply and fix in repair lamp holder (Angle), PVC type suitable forPendent/batten fittings complete as specified and directed
Supply and fix in repair call bell ding dong AC 230 Volts complete as specified and directed.
Supply and fixing LED lamp 10 Watt B 22 complete as specified and directed.
Supply and fix in repair MCB DB SPN 240V double door outdoor type, 12 way with bush bar of appropriate current carrying capacity, neutral link, earth bar and din rail complete of following size complete as specified and directed. Make: Legrand/indo Asian/ Havells/Standard.
Supply and fix in replacement surface and wall mounted 10 W 2 feet LED batten, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser and integrated electronic driver complete as specified and directed. Make Havells. ENDURALINEARNEOBS10WLED865PCWH Or Equivalent in Philips/CG as approved by GE
S&F in replacement wall mounted 20 W 4 ft LED batten, extruded aluminium housing provided for efficient heat dissipation with Polycarbonate diffuser andtegrated electronic driver complete as specified and directed. .Make : Havells : ENDURALINEARNEOBS20WLED865SPCWH or equivalent in Philips/CG as approved by GE
Supply and fixing LED Bulk head fitting 10W with oval shaped surface mounted LED ,PMMA diffuser,powder coated white finish housing complete as specified and directed. Make:- Havells. RUGBYNEONFT10WLED860SSYMTOPC or equivalent in Philips/wipro as approved by GE
Fabrication and fixing only only steel work in trusses including special shaped washer etc. obtained from Item no. 27 herein above complete as specified and directed.
Fixing only Pre-Painted Galvalume aluminium Zinc coating GI based corrugated steel sheet obtained from Item No. 24 herein above complete as specified and directed.
Palace constructions
Sreekrupa Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .