Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.9 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹47.0 L+₹2.1 L (4.69%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹47.9 L+₹3.0 L (6.61%)Rejected-Finance VILLAGE GOROIMARI PO HALESWAR TEZPUR 784104 DIST SONITPUR ASSAM | SONITPUR | ASSAM | 784104 | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹48.3 L+₹3.4 L (7.57%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹48.6 L+₹3.7 L (8.14%)Rejected-Finance JYOTISH ROAD TEZPUR DISTT SONITPUR ASSAM 784001 | SONITPUR | ASSAM | 784001 | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
22 Jun 2022, 6:00 pmClosed
GE (AF) TEZPUR
GE (AF) TEZPUR POST-SALONIBARI DIST- SONITPUR ASSAM-784104
REPAIR TO CGI ROOF SHEETS AND OTHER B/R WORKS IN DOMESTIC AREA AND REPAIR/REPLACEMENT OF INTERNAL FLAME PROOF WIRING,FLAME PROOF LIGHT,FLAME PROOF EXHAUST FANS,MCBs,DBs AND SUB MAIN WIRING AT AF STN TEZPUR UNDER GE (AF) TEZPUR.
2022_MES_531279_1
GE(AF)/TEZ/8652/2022-23
Open Tender
Civil Works
Item Rate
180 days
AFS TEZPUR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) TEZPUR
₹90,000
Yes
20 Jul 2022
16 Jun 2022
24 Jun 2022
16 Jun 2022
22 Jun 2022
16 Jun 2022
Amount
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings,heads, shoes, bends, swan-necks,etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories),complete all as directed.
Materials and Labour for second class hard wood plain fillets,square, rectangular or triangular in section,bullnosed,splayed,chamfered or rounded on one edge or face,sectional area exceeding 6 but not exceeding 13 sq.cm,wrought,secured with screws,complete all as specified and directed.
Materials and Labour for second class hard wood plain fillets,square, rectangular or triangular in section,sectional area exceeding 13 but not exceeding 25 sq.cm,clean sawn,secured with nails or brads including dismantling existing fillets under 40 sq. cm in section,complete all as specified and directed.
Materials and Labour for,rolled mild steel,Fe-410 W (Gde E-250) quality A, in roof trusses (framed), trussed,purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections),including distance pieces, cleats etc.,complete all as specified and directed.
Material and Labour for pre-painted, galvalume aluminium zinc coating GI based corrugated steel sheet, 0.50 mm thick of any colour, having tensile strength of 550 Mpa, as in roof covering/cladding to wall, fixed with self-tapping screws, including dismantling of existing plain or corrugated steel sheeting,any gauge, thickness, including Nainital or similar pattern roof coverings,complete all as specified and directed.
Material and Labour for pre-painted, galvalume aluminium zinc coating GI based plain steel sheet, 0.50 mm thick of any colour, having tensile strength of 550 Mpa, as in roof covering/cladding to wall, fixed with self-tapping screws,complete all as specified and directed. Notes:- (i) The existing ridge, valley, cladding to wall and gutters etc. sheets are deemed to be dismantled along with the roofing sheets. (ii) Old unserviceable sheets will be sold to the Contractor under relevant item in Schedule of Credit.
Materials and Labour for,anodised aluminium snap grid frame work for false ceiling,size of grid 605 mm x 605 mm as per clause 10.38 of SSR Part-I (2009) including 6 mm thick, high pressure steam cured (HPSC) non asbestos fibre cement building boards fixed or laid to aluminium framework with screws and including dismantling existing wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets, complete all as specified and directed.
Materials and Labour for,4 mm thick, asbestos cement plain building boards, fixed to timber framework with screws in ceiling flat or sloping including dismantling existing wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets,complete all as specified and directed.
Material and Labour for three coats of white wash in ceiling,complete all as specified and directed.
Material and Labour for applying two coats of synthetic enamel paint (ordinary tint) over a coat of pink primer on new or previously untreated wood or wood based surface of any description, not exc 10 cm in width or girth,when unconnected with other painting or when painted in a different tint, including preparation of surfaces complete all as specified and directed.
Material and Labour for applying two coats of synthetic enamel paint (ordinary tint) over a coat of red oxide zinc chrome primer on new or previously untreated steel and iron surface of any description,over 10 cm in width or girth,not otherwise described, including preparation of surfaces complete all as specified and directed.
Material and Labour for preparing surfaces of wood and wood based materials,new or old, of any description and girth, not otherwise described and treated with two coats of creosote,complete all as specified and directed.
Materials and Labour for point wiring with 1.50 Sq. mm (nominal area) FRLSH PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and including stove enamelled steel conduit complete with all fittings and accessories,fixed to walls/ceiling, including stove enamelled black steel junction box, with cover and outlets and including 1.50 Sq. mm (nominal area) FRLSH PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly for,one 3 Pin 5 Amps socket outlet independent ,including taking down carefully existing copper/ aluminium point wiring (light, fan, socket or power) complete including fittings such as switches, ceiling roses, pendent, regulators, sockets, light fittings etc, removing materials from site and making good disturbed surfaces of walls, floors etc,complete all as specified and directed.
Materials and Labour for point wiring with 4.00 Sq. mm (nominal area) FRLSH PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and including stove enamelled steel conduit complete with all fittings and accessories,fixed to walls/ceiling, including stove enamelled black steel junction box, with cover and outlets and including 4.00 Sq. mm (nominal area) FRLHS PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly for,one 3 Pin 15/16 Amps socket outlet independent,including taking down carefully existing copper/ aluminium point wiring (light, fan, socket or power) complete including fittings such as switches, ceiling roses, pendent, regulators, sockets, light fittings etc, removing materials from site and making good disturbed surfaces of walls, floors etc,complete all as specified and directed
Supply and Fix,switch flame proof rotary type with termination box in LM6,16A,single pole 250V,complete all as specified and directed.
Supply and Fix,flame proof switch socket & plug combined in LM6 cable termination box in LM6,16A,250V, 2P+earth ,complete all as specified and directed.
Supply and Fix, 80 mm dia.,cast aluminium body LM6, flame proof,weather proof junction box 4 way terminal with 4 number of 3/4 ET cable entry, protection type Ex-D,Zone 1 & Zone 2,IP-55,Gas Group IIB,Temp Class T6,complete all as specified and directed. [Cat No SAI/JB/1002 of Sudhir Electricals or equivalent Model of Make Balinga/Shyam]
Supply and Fix in repair, knob as per OEM's specification for switch flame proof rotary type,16A,single pole 250V,complete all as specified and directed.
Supply and Fixing LED light fitting 1x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass with LED tube light fixtures driver,holders, connector etc. complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size.,complete all as specified and directed.
Supply and Fixing in repair, LED light fitting 1x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass with LED tube light fixtures driver,holders, connector etc. complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size.,complete all as specified and directed.
Supply and Fixing, LED light fitting 2x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass with LED tube light fixtures driver,holders, connector etc. complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size,complete all as specified and directed.
Supply and Fixing in repair, LED light fitting 2x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass with LED tube light fixtures driver,holders, connector etc. complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size,complete all as specified and directed.
Supply and Fixing, Flameproof cum Waterproof LED Bulk Head light fitting of 30W, IP66 protection of Cast Aluminum alloy material and Heat and Impact resistance toughen 'A' clear glass having Anti corrosive epoxy powder coated finish complete with all accessories pre wired and including connecting up with three core flexible copper conductor cable with suitable size,complete all as specified and directed.
Supply and Fixing in repair, Flameproof cum Waterproof LED Bulk Head light fitting of 30W, IP66 protection of Cast Aluminum alloy material and Heat and Impact resistance toughen 'A' clear glass having Anti corrosive epoxy powder coated finish complete with all accessories pre wired and including connecting up with three core flexible copper conductor cable with suitable size,complete all as specified and directed.
Fixing Only flame proof light fittings of any description including connecting up with three core flexible copper conductor cable with suitable size,complete all as specified and directed. Note:- Old Existing Serviceable flameproof light fittings obtained from Serial Item No.55 Here in Before shall be re-fixed.
Materials and Labour for two single core FRLSH PVC insulated unsheathed cable 4.00 Sq. mm. (Nominal area) with stranded copper conductor cable, 1100 Volts grade, drawn in and including stove enamelled steel conduit and continuous earth wire of single core FRLSH PVC insulated, unsheathed cable 4.00 Sq. mm (nominal area) with stranded copper conductor cable, 1100 Volts grade for circuit/sub main wiring,including taking down carefully existing copper/ aluminium circuit/submain wirings of any size (2 runs single core and earth continuity) complete including PVC casing capping/ PVC conduit/Steel Conduit with fittings etc, removing materials from site and making good disturbed surfaces of walls, floors etc.,complete all as specified and directed.
Materials and Labour for two single core FRLSH PVC insulated unsheathed cable 6.00 Sq. mm. (Nominal area) with stranded copper conductor cable, 1100 Volts grade, drawn in and including stove enamelled steel conduit and continuous earth wire of single core FRLSH PVC insulated, unsheathed cable 6.00 Sq. mm (nominal area) with stranded copper conductor cable, 1100 Volts grade for circuit/sub main wiring,including taking down carefully existing copper/ aluminium circuit/submain wirings of any size (2 runs single core and earth continuity) complete including PVC casing capping/ PVC conduit/Steel Conduit with fittings etc, removing materials from site and making good disturbed surfaces of walls, floors etc.,complete all as specified and directed.
Materials and Labour for two single core FRLSH PVC insulated unsheathed cable 4.00 Sq. mm. (Nominal area) with stranded copper conductor cable, 1100 Volts grade, drawn in and including PVC casing and capping and continuous earth wire of single core FRLSH PVC insulated, unsheathed cable 4.00 Sq. mm (nominal area) with stranded copper conductor cable, 1100 Volts grade for circuit/sub main wiring including taking down carefully existing copper/ aluminium circuit/submain wirings of any size (2 runs single core and earth continuity) complete including PVC casing capping/ PVC conduit/Steel Conduit with fittings etc, removing materials from site and making good disturbed surfaces of walls, floors etc.,complete all as specified and directed.
Materials and Labour for two single core FRLSH PVC insulated unsheathed cable 6.00 Sq. mm. (Nominal area) with stranded copper conductor cable, 1100 Volts grade, drawn in and including PVC casing and capping and continuous earth wire of single core FRLSH PVC insulated, unsheathed cable 6.00 Sq. mm (nominal area) with stranded copper conductor cable, 1100 Volts grade for circuit/sub main wiring including taking down carefully existing copper/ aluminium circuit/submain wirings of any size (2 runs single core and earth continuity) complete including PVC casing capping/ PVC conduit/Steel Conduit with fittings etc, removing materials from site and making good disturbed surfaces of walls, floors etc.,complete all as specified and directed.
Materials and Labour for two single core FRLSH PVC insulated unsheathed cable 10.00 Sq. mm. (Nominal area) with stranded copper conductor cable, 1100 Volts grade, drawn in and including PVC casing and capping and continuous earth wire of single core FRLSH PVC insulated, unsheathed cable 10.00 Sq. mm (nominal area) with stranded copper conductor cable, 1100 Volts grade for circuit/sub main wiring including taking down carefully existing copper/ aluminium circuit/submain wirings of any size (2 runs single core and earth continuity) complete including PVC casing capping/ PVC conduit/Steel Conduit with fittings etc, removing materials from site and making good disturbed surfaces of walls, floors etc.,complete all as specified and directed.
Materials and Labour for two single core FRLSH PVC insulated unsheathed cable 4.00 Sq. mm. (Nominal area) with stranded copper conductor cable, 1100 Volts grade, drawn in existing surface/recessed steel/PVC conduit and continuous earth wire of single core FRLSH PVC insulated, unsheathed cable 4.00 Sq. mm (nominal area) with stranded copper conductor cable, 1100 Volts grade for circuit/sub main wiring including taking down carefully existing copper/ aluminium circuit/submain wirings of any size (2 runs single core and earth continuity) complete including PVC casing capping/ PVC conduit/Steel Conduit with fittings etc, removing materials from site and making good disturbed surfaces of walls, floors etc.,complete all as specified and directed.
Materials and Labour for two single core FRLSH PVC insulated unsheathed cable 6.00 Sq. mm. (Nominal area) with stranded copper conductor cable, 1100 Volts grade, drawn in existing surface/recessed steel/PVC conduit and continuous earth wire of single core FRLSH PVC insulated, unsheathed cable 6.00 Sq. mm (nominal area) with stranded copper conductor cable, 1100 Volts grade for circuit/sub main wiring including taking down carefully existing copper/ aluminium circuit/submain wirings of any size (2 runs single core and earth continuity) complete including PVC casing capping/ PVC conduit/Steel Conduit with fittings etc, removing materials from site and making good disturbed surfaces of walls, floors etc.,complete all as specified and directed.
Dressing/aligning of existing circuit/sub main wiring by taking down carefully existing copper/ aluminium circuit/submain wirings of any size (2 runs single core and earth continuity) complete including steel conduit with fittings etc.,making good disturbed surfaces of walls, floors etc.and refixing the same in original position,complete all as specified and directed. Note:- Damaged steel conduit/PVC Casing Capping for replacement if any will be measured and paid seperately under respective item of this BOQ.
Supply Only,25 mm size PVC Casing Capping,ISI Marked(IS:14927),all as specified.
Supply Only,20 mm external diameter,stove enamelled black,rigid steel conduit,welded,all as specified.
Supply and Fix, flame proof, weather proof enclosure for MCB Distribution Board, Single Phase and Neutral, with incoming & outgoing terminals chamber, bus bar chamber comprising of 02(Two) Nos. copper bus bars of suitable rating,separate MCB chambers suitable for accommodating 03 (Three) Nos. of 6-32 Amp. DP MCB 'C' curve,enclosure made of cast aluminium alloy LM6, weather proof IP65, finished inside and outside with light grey epoxy powder coating, including cable glands, terminals, hardware and mounting arrangement all as per Cat No. MCBDB/186 of Make “Sudhir” or equivalent Model of Make Balinga/Shyam,complete all as specified and directed.
Supply and Fix,single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB, 20 Amps, 240V, complete all as specified and directed. [Cat No. 5078 11 of Make Legrand or equivalent Model of Make L&T/ Hager/Seimens/GE/Schneider/ABB]
Supply and Fix, Double Door, Sheet Metal Enclosure for DBs for mounting of MCB for 240 Volts, 4 way, with 200 Amps rated bus bar, Single Pole & Neutral,complete all as specified and directed. [Cat No. 5076 10 of Make Legrand or equivalent Model of Make L&T/Hager/ Seimens/GE/Schneider/ABB]
Supply and Fix, Double Door, Sheet Metal Enclosure for DBs for mounting of MCB for 240 Volts, 8 way, with 200 Amps rated bus bar, Single Pole & Neutral,complete all as specified and directed. [Cat No. 5076 11 of Make Legrand or equivalent Model of Make L&T/Hager/ Seimens/GE/Schneider/ABB]
Supply and Fix, Double Door, Sheet Metal Enclosure for DBs,415 Volts, 4 Way,Triple Pole & Neutral,complete all as specified and directed. [Cat No. 5076 70 of Make Legrand or equivalent Model of Make L&T/Hager/ Seimens/GE/Schneider/ABB]
Supply and fix miniature circuit breaker (MCBs) single pole, 240 Volts, 10KA,'C' curve, 6 to 32 Amps complete all as specified and directed. [Cat No. 4085 87-4085 95 of Make Legrand or equivalent Model of Make L&T/Hager/Seimens/GE/Schneider/ABB]
Supply and fix in repair miniature circuit breaker (MCBs) single pole, 240 Volts, 10KA,'C' curve, 6 to 32 Amps complete all as specified and directed. [Cat No. 4085 87-4085 95 of Make Legrand or equivalent Model of Make L&T/Hager/Seimens/GE/Schneider/ABB]
Supply and fix miniature circuit breaker (MCBs) single pole and neutral, 240 Volts, 10KA,'C' curve, 6 to 32 Amps complete all as specified and directed. [Cat No. 4086 09-4086 17 of Make Legrand or equivalent Model of Make L&T/ Hager/Seimens/GE/Schneider/ABB]
Supply and fix in repair miniature circuit breaker (MCBs) single pole and neutral, 240 Volts, 10KA,'C' curve, 6 to 32 Amps complete all as specified and directed. [Cat No. 4086 09-4086 17 of Make Legrand or equivalent Model of Make L&T/ Hager/Seimens/GE/Schneider/ABB]
Supply and fix miniature circuit breaker (MCBs) single pole and neutral, 240 Volts, 10KA,'C' curve, 40 Amps complete all as specified and directed. [Cat No. 4086 18 of Make Legrand or equivalent Model of Make L&T/ Hager/Seimens/GE/Schneider/ABB]
Supply and fix in repair miniature circuit breaker (MCBs) single pole and neutral, 240 Volts, 10KA,'C' curve,40 Amps complete all as specified and directed. [Cat No. 4086 18 of Make Legrand or equivalent Model of Make L&T/ Hager/Seimens/GE/Schneider/ABB]
Supply and Fix, miniature circuit breaker (MCBs) triple pole, & neutral, 415 Volts, 10KA,'C' curve, 63 Amps complete all as specified and directed. [Cat No. 4086 83 of Make Legrand or equivalent Model of Make L&T/ Seimens]
Supply and Fix in repair, miniature circuit breaker (MCBs) triple pole, & neutral, 415 Volts, 10KA,'C' curve, 63 Amps complete all as specified and directed. [Cat No. 4086 83 of Make Legrand or equivalent Model of Make L&T/ Seimens]
Supply and Fix, PVC blanking plate,single way for blank ways of MCB DBs,complete all as specified and directed.
Taking down carefully existing flame proof tube light fittings 1x36/40W,replacement of the lamp with 1 x 20 Watts LED glass T8 tube with in built driver and metal heat sinks,lumen efficacy 100 Lumens/Watt,refixing of light fittings in original position including connecting up with three core flexible copper conductor cable with suitable size,complete all as specified and directed. [Cat No.LT8-20-865-(2) of Make 'Crompton Greaves' or equivalent Model of Make 'Philips'/ 'Wipro'/'GE']
Taking down carefully existing flame proof tube light fittings 2x36/40W,replacement of the lamp with 2 x 20 Watts LED glass T8 tube with in built driver and metal heat sinks,lumen efficacy 100 Lumens/Watt,refixing of light fittings in original position including connecting up with three core flexible copper conductor cable with suitable size,complete all as specified and directed. [Cat No.LT8-20-865-2 'CRYSTA' of Make 'Crompton Greaves' or equivalent Model of Make 'Philips'/ 'Wipro'/'GE']
Taking down carefully existing flame proof bulk head fittings 1x60/100W,replacement of the lamp with 1 x 30 Watts retrofit LED Lamp (Spiral B-22 base),lumen efficacy 100 Lumens/Watt, refixing of light fittings in original position including connecting up with three core flexible copper conductor cable with suitable size,complete all as specified and directed. [Cat No. LED30DFCDL of Make 'Crompton' or equivalent Model of Make 'Philips'/ 'Wipro'/'GE']
Taking down carefully existing flame proof ceiling fan 1200 mm sweep, dismantaling of parts, removing burnt out windings with insulating materials,cleaning throughly internally and externally, rewinding fan motor with super enamelled copper wires of existing size including provision of all insulating materials and varnishing, lubrication of bearing / bushes using fresh lubricant all as per OEMs reccommendations, replacement of defective parts,re-assembling, hanging in original position including testing and commissioning, complete all as specified and directed. NOTES:- (i) Repairs and rewinding woks shall be carried out through authorised technicians of the OEMs as approved by GE. (ii) Spares for replacement shall be as per OEM's specifications.
Taking down carefully existing flame proof exhaust fan 300 mm/450 mm size, dismantaling of parts, removing burnt out windings with insulating materials,cleaning throughly internally and externally, rewinding fan motor with super enamelled copper wires of existing size including provision of all insulating materials and varnishing, lubrication of bearing / bushes using fresh lubricant all as per OEMs reccommendations, replacement of defective parts,re-assembling, fixing in original position including testing and commissioning, complete all as specified and directed. NOTES:- (i) Repairs and rewinding woks shall be carried out through authorised technicians of the OEMs as approved by GE. (ii) Spares for replacement shall be as per OEM's specifications.
Shri A. K. Goswami
Singhs Construction
M/S N G CHOWDHURY
SHRI D. C. BISWAS
kabitaconstruction
M/S Mandeep Singh
M/S Kangkans
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .