Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
Refer Docs
Closing Date
7 Dec 2020, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SANTHOSH
MATERIALS DEPT FACT PH 0484 2568347
POWER CONTACTOR
2020_FACT_595132_1
MM/122/E22395
Limited
Electrical Goods/Equipment
Supply
UDYOGAMANDAL
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
Exempted
8 Dec 2020
5 Nov 2020
8 Dec 2020
5 Nov 2020
7 Dec 2020
5 Nov 2020
90 days
L & T MAKE LT POWER CONTACTOR, AIR BREAK, IN OPEN EXECUTION, RATED CURRENT(AC3) : 40A, AT 415V, 50HZ, AUXILIARY CONTACTS : 2 NO+2 NC , OPERATING COIL VOLTAGE 110V, 50 HZ, TYPE : ML3, CAT No : SS90721, COIL VOLTAGE SUFFIX : AOOO
L & T MAKE LT POWER CONTACTOR, AIR BREAK, IN OPEN EXECUTION, RATED CURRENT(AC3) : 16A, AT 415V, 50HZ, AUXILIARY CONTACTS : 2 NO+2 NC , OPERATING COIL VOLTAGE 110V, 50 HZ, TYPE : ML1, CAT No : SS90851, COIL VOLTAGE SUFFIX : AOOO
L & T MAKE LT POWER CONTACTOR, AIR BREAK, IN OPEN EXECUTION RATED CURRENT (AC3) : 32A, AT 415V 50HZ, AUXILIARY CONTACTS : 2 NO+2 NC OPERATING COIL VOLTAGE : 110V, 50 HZ TYPE : ML2 CAT No : SS90701 COIL VOLTAGE SUFFIX : AOOO
L <(>&<)> T MAKE LT POWER CONTACTOR AIR BREAK, IN OPEN EXECUTION RATED CURRENT(AC3) : 70A, AT 415V, 50HZ AUXILIARY CONTACTS : 2 NO+2 NC OPERATING COIL VOLTAGE : 110V, 50 HZ TYPE : ML4 CAT No. : SS90910 COIL VOLTAGE SUFFIX : AOOO
L & T MAKE LT POWER CONTACTOR, AIR BREAK, IN OPEN EXECUTION, RATED CURRENT(AC3) : 110A, AT 415V, 50HZ, AUXILIARY CONTACTS : 2 NO+2 N C, OPERATING COIL VOLTAGE 110V, 50 HZ, TYPE : ML6, CAT No : SS90921, COIL VOLTAGE SUFFIX : AOOO
L & T MAKE LT POWER CONTACTOR, AIR BREAK, IN OPEN EXECUTION, RATED CURRENT(AC3) : 200A, AT 415V, 50HZ, AUXILIARY CONTACTS : 2 NO+2 N C, OPERATING COIL VOLTAGE 110V, 50 HZ, TYPE : ML10, CAT No : SS90935, COIL VOLTAGE SUFFIX : AOOO
L & T MAKE LT POWER CONTACTOR, AIR BREAK, IN OPEN EXECUTION, RATED CURRENT(AC3) : 300A, AT 415V, 50HZ, AUXILIARY CONTACTS : 2 NO+2 N C, OPERATING COIL VOLTAGE 110V, 50 HZ, TYPE : ML12, CAT No : SS91010, COIL VOLTAGE SUFFIX : AOOO
Thermal, bi-metallic, overload relay<(>,<)> separate-mounting type, CT operated, 3 pole with inbuilt single phase preventor, self / hand reset type with 1 NO + 1 NC auxiliary contacts. Current Setting Range : 1.4 - 2.3 Amps. Make : L<(>&<)>T Type : MN 2 or equivalent Cat No : SS9414OOPO
THERMAL OVERLOAD RELAY, 6-10A, MN2
Thermal, bi-metallic, overload relay<(>,<)> separate-mounting type, CT operated, 3 pole with inbuilt single phase preventor, self / hand reset type with 1 NO + 1 NC auxiliary contacts. Current Setting Range : 3 - 5 Amps. Make : L<(>&<)>T Type : MN 2 or equivalent Cat No : SS94141OOSO
Thermal, bi-metallic, overload relay<(>,<)> separate-mounting type, CT operated, 3 pole with inbuilt single phase preventor, self / hand reset type with 1 NO + 1 NC auxiliary contacts. Current Setting Range : 9 - 15 Amps. Make : L and T Type : MN 2 or equivalent Cat No : SS94142OOBO
Thermal, bi-metallic, overload relay<(>,<)> separate-mounting type, CT operated, 3 pole with inbuilt single phase preventor, self / hand reset type with 1 NO + 1 NC auxiliary contacts. Current Setting Range : 14 - 23 Amps. Make : L and T Type : MN 2 or equivalent Cat No : SS94144OODO
Thermal, bi-metallic, overload relay<(>,<)> separate-mounting type, CT operated, 3 pole with inbuilt single phase preventor, self / hand reset type with 1 NO + 1 NC auxiliary contacts. Current Setting Range : 20 - 33 Amps. Make : L<(>&<)>T Type : MN 5 or equivalent Cat No : SS 94136OOEO
Thermal, bi-metallic, overload relay<(>,<)> separate-mounting type, CT operated, 3 pole with inbuilt single phase preventor, self / hand reset type with 1 NO + 1 NC auxiliary contacts. Current Setting Range : 30 - 50 Amps. Make : L<(>&<)>T Type : MN 5 or equivalent Cat No : SS 94136OOGO
SPARES KIT, FOR ML1 CONTACTOR, WITHOUT COIL, MAKE : L&T, CAT No : SS95303
SPARES KIT, FOR ML3 CONTACTOR, WITHOUT COIL, MAKE : L&T, CAT No : SS95309
SPARES KIT, FOR ML4 CONTACTOR, WITHOUT COIL, MAKE : L&T, CAT No : SS95311
SPARES KIT, FOR ML2 CONTACTOR, WITHOUT COIL MAKE : L<(>&<)>T CAT No : SS95307
SPARES KIT, FOR ML6 CONTACTOR, WITHOUT COIL, MAKE : L&T, CAT No : SS95313
SPARES KIT, FOR ML10 CONTACTOR, WITHOUT COIL, MAKE : L&T, CAT No : SS95315
SPARES KIT, FOR ML12 CONTACTOR, WITHOUT COIL, MAKE : L&T, CAT No : SS95317
Bidder Name
DEEPA AGENCIES
stage.html
html • 0.02 MB
finance_625184.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .