Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.0 LAccepted-AOC | L1 | Accepted-AOC Accepted as a first lowest | |
| 2 | L2₹3.5 L+₹55,012 (18.5%)Rejected-AOC | L2 | Rejected-AOC Reject due to second lowest | |
| 3 | Rejected-Technical | - | Rejected-Technical Does not qualify pre- Qualifying condition no-3 | |
| 4 | Rejected-Technical | - | Rejected-Technical Does not qualify pre- Qualifying condition no-3 and 4 |
Tender Value
Refer Docs
EMD Value
₹7,000
Closing Date
19 Jun 2021, 12:00 pmClosed
Superintending Engineer
Electricity Urban Distribution Circle
CONSTN. OF 11 KV INDPT FEEDER EMANATING FROM 33/11 KV S/S SHAHIDABAD GIVING 1500 KVA LOAD FOR CHARGING ELECTRIC BUS STATION AND MAINT. DEPOT (LMV-11) AT LAKRI FAZALPUR, IN FAVOUR OF PARIYOJNA PRABANDHAK, CONST. JAL NIGAM, UNDER EUDD-I, MBD
2021_PVVNL_589203_1
ST/07/EUDC(M)/2021-22
Open Tender
Miscellaneous Services
Lump-sum
MORADABAD
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
Superintending Engineer, EUDC
₹7,000
Yes
5 Aug 2021
24 May 2021
19 Jun 2021
24 May 2021
19 Jun 2021
24 May 2021
Safe Carriage of Material from Majhola centre store to work site Mainather Lakhri Fazalpur including its Loading and unloading at both ends.
S.T. Pole 13 Mtr. Long. (30 Nos.) & 11 MTR Long (07 Nos).
11 KV XLPE Cable for size 3x185mm2
ACSR Dog conductor
11 KV VCB I/C CTR 400/200/5Amp 350 MVA 630 Amp. (01 No.), 11 KV VCB O/G FDR 200/100/5Amp 250MVA 630 Amp. (01 No.), 11 KV CT/PT Unit 60/5Amp.(01 No.) & 11 KV Metering cubical pilfer Resistant 60/5 Amp. (01 No.)
11 KV Line Material Such as M.S. Channel, M.S Angle G.I. X- Arms. V-Type, Control Cable, G.J Wire 6 SWG. 11 KV Stay Rods, 11 KV E/Rods, Pin Insulators, Disc Insulators etc.
Digging of pits and Erection of 13 Mtr Long Single S.T Pole including fixing of all required accessories on pole by providing M.S Clamps, Nut & Bolts.
Digging of pits, Erection of 13 mtr Long S.T. Double pole including fixing and fitting of all required accessories by providing M.S Clamps Nut & Bolts.
Digging of pits and Erection of 11 Mtr. Long S.T. single pole by providing M.S Clamps, Nut & Bolts.
Digging of pits and Erection of 11 Mtr. Long S.T. Double Pole including fixing and fitting of all required accessories by providing M.S Clamps Nut & Bolts.
Fabrication of M.S Channel, M.S. Angle, T-off Channels 11 KV Cross Arms. Guarding Angles Making its cutting Drilling of hole, etc Complete Work.
Grounding of M.S Earth Rods by Driving into earth with the help of G.I Wire including its connecting from S.T Pole by providing and fixing of M.S. Clamp, Nut & Bolts.
Grouting of Poles in CC 1:4:6 Cement Sand and Brick Ballast of 1/6th of full Length of the pole up to ground level and making plinth all around the Pole.
Grouting of Stay Rods (20x1800mm) including all work of excavation cement concrete in ratio of 1:4:6 including back filling of soil and proper ramming etc.
Fixing, Tightening and nozelling of Stay wire with stay Rods and Stay Insulators with the pole of required Tension by providing stay Clamps. Nuts & Bolts etc.
Laying, Sagging Stringing and binding of ACSR Dog Conductor with all other accessories on pole as per RESSPO Norms.
Laying mounting of 11 KV XLPE cable on S.T. Poles of size 3x185mm2 and making connections as per RESSPO Norms.
Filling and Fixing of 11 KV outdoor/Indoor Type Cable Jointing Kits as per RESSPO Norms.
Digging of cable Trench in size of 0.45x0.80 Mtr.
Laying of 11 KV 3x185 mm2 Cable in the trench for Double Ckt.
Providing 150 mm Sand Cushion beneath and 150 mm above the cable, the cable shall be duly protected by 1st class Bricks. Two on either side, third on Top of the cable laid in the series one after the other.
Refilling and ramming of the left out soil closing and trench and leveling spare cable shall be left in the loop shape at both ends including providing of all material and T&P.
Providing and Fixing of Danger Board with clamp, Nut & Bolts.
Fitting of 11 KV Pilfer Proof metering cubical including making proper connection of Size 60/5Amp.
Mounting and Fixing of 11 KV CT/PT Unit on Double Pole including making proper connections. Of size 60/5Amp.
Providing G.I. Pipe 6” dia for’ inserting 11 KV XLPE Cable for Safety of Cable on Single/ Double pole by providing and Fixing of M.S. Clamps, Nut & Bolts.
Trimming of Tree Branches Coming in the route of Line of 11 KV Spans.
Fixing and fitting of T-off Channels on Poles by Providing M.S. Clamps, Nuts & Bolts.
Providing and Grounding of Chemical Rod into pit making chemical connection and its connecting By G.I. Strip by welding complete work on VCB Pannels.
Laying of Control Cable of Size 4x2.5 mm2 and 2x2.5 mm2 making its connection in switch yard and control Room complete work.
Providing and Fixing of Number Plate with M.S. Clamsp, Nuts & Bolts.
Providing and wrapping of barbed wire on 11KV S.T. Pole at a height of 2.75 Mtr. From the ground Level as per RESSPO Norms.
Guarding of 11 KV Line with G.I. wire and making Jaal with fitting of cross lesses apart 02 Mtr. by Fixing and fitting of guarding Angles on Poles by providing M.S. Clamps, Nuts & Bolts.
Erection, Grouting and commissioning of 11KV out Going VCD of CTR 200/100/5 Amp. 250 MVA.
Erection, Grouting and commissioning of 11 KV incoming VCB CTR 400/200/5Amp. 350 MVA 630 Amps. Complete work.
Singh Construction
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .