| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹58.6 LAccepted-AOC | L1 | Accepted-AOC L1 Accepted | |
| 2 | L2₹60.0 L+₹1.2 L (2.03%)Rejected-AOC | L2 | Rejected-AOC L2 Rejected |
| Sl No | Description | Qty | Unit | INTIMATE REFRIGERATION AND AIR CONDITIONS L1 | PIONEER COOLTECH L2 |
|---|---|---|---|---|---|
| 1.00AC | |||||
| 1.00 | OD15755/2025-2026:Supply ,Conveyance, Loading , Installation, Testing and commissioning of 22 HP Modular type VRF OUTDOOR UNIT at roof top of the G+9 storied building including lifting and shifting of air conditioning system. The outdoor unit shall be factory assembled weather proof casting constructed from heavy gauge mild steel panels with epoxy coated painting and matching air cooled variable heat exchanger with copper tubes and aluminium fins duly covered by anti-corrosion and hydrophilic resin film. VRF outdoor unit shall comprise of high efficiency Hermetically sealed BLDC Inverter scroll/Twin rotary compressors . OEM should use there on make compressors in VRF/VRV system which is to be supplied. System COP shall not be less than 3.4 AT at AHRI condition and suitable to operate at heat load proportional to Indoor temperature requirement. Aluminium fins of condenser coil shall have anti corrosive epoxy resin ocean black coating along with hydrophilic coating precoated at factory.Anti corrosive treatment should have been tested for atleast 2500 Hrs of standard salt spray test.The treatment should be suitable for areas of high pollution and salt laden air. Modular system to be configured as per mention modules given in bracket. | 4 | each | 6,55,772.97 ₹26,23,091.88 Lowest | 7,00,000 ₹28,00,000 |
| 1.00 | OD4192/2025-2026:Supply, Installation, Testing & Commissioning of 6 TR high static DUCTABLE INDOOR UNIT suitable for VRV/VRF system including , indoor fan motors, electronic expansion valve that controls the flow of refrigerant in respond to the load variations of room according to set temperature, which can set by remote controllers. electricity characteristics for indoor unit shall be 240 volts/ 1phase / 50hz. i)casing shall be made of galvanized steel sheet (GSS) with minimum 0.8 mm thickness. zinc coating thickness on GSS shall be of minimum 220 GSM. ii) inner and outer side of the casing shall have noise absorbing polyethylene insulation with adequate thickness. iii) unit shall be provided wired remote controller and it should facilitate on/ off function, change of temperature settings, fan speed setting, operation mode setting, clock function and error code display ., including drain tray , the whole unit shall be fixed on ceiling with using suitable size anchor fastener and threaded rod etc -Ductable Unit 6 TR with inbuilt drain pump with remote controller. | 5 | each | 95,267.7 ₹4,76,338.5 Lowest | 96,250 ₹4,81,250 |
| 1.00 | OD45247/2025-2026:Supply, Installation, Testing & Commissioning of 4.6 TR high static DUCTABLE INDOOR UNIT suitable for VRV/VRF system including , indoor fan motors, electronic expansion valve that controls the flow of refrigerant in respond to the load variations of room according to set temperature, which can set by remote controllers. electricity characteristics for indoor unit shall be 240 volts/ 1phase / 50hz. i)casing shall be made of galvanized steel sheet (GSS) with minimum 0.8 mm thickness. zinc coating thickness on GSS shall be of minimum 220 GSM. ii) inner and outer side of the casing shall have noise absorbing polyethylene insulation with adequate thickness. iii) unit shall be provided wired remote controller and it should facilitate on/ off function, change of temperature settings, fan speed setting, operation mode setting, clock function and error code display ., including drain tray , the whole unit shall be fixed on ceiling with using suitable size anchor fastener and threaded rod etc -Ductable Unit 4.6 TR with inbuilt drain pump with remote controller. | 1 | each | 72,171.99 ₹72,171.99 Lowest | 72,900 ₹72,900 |
| 1.00 | OD45113/2025-2026:Supply, Installation, Testing & Commissioning of 4 TR high static DUCTABLE INDOOR UNIT suitable for VRV/VRF system including , indoor fan motors, electronic expansion valve that controls the flow of refrigerant in respond to the load variations of room according to set temperature, which can set by remote controllers. electricity characteristics for indoor unit shall be 240 volts/ 1phase / 50hz. i)casing shall be made of galvanized steel sheet (GSS) with minimum 0.8 mm thickness. zinc coating thickness on GSS shall be of minimum 220 GSM. ii) inner and outer side of the casing shall have noise absorbing polyethylene insulation with adequate thickness. iii) unit shall be provided wired remote controller and it should facilitate on/ off function, change of temperature settings, fan speed setting, operation mode setting, clock function and error code display ., including drain tray , the whole unit shall be fixed on ceiling with using suitable size anchor fastener and threaded rod etc -Ductable Unit 4 TR with inbuilt drain pump with remote controller. | 4 | each | 62,369.99 ₹2,49,479.96 Lowest | 63,500 ₹2,54,000 |
| 1.00 | OD45260/2025-2026:Supply, Installation, Testing & Commissioning of 3.5TR high static DUCTABLE INDOOR UNIT suitable for VRV/VRF system including , indoor fan motors, electronic expansion valve that controls the flow of refrigerant in respond to the load variations of room according to set temperature, which can set by remote controllers. electricity characteristics for indoor unit shall be 240 volts/ 1phase / 50hz. i)casing shall be made of galvanized steel sheet (GSS) with minimum 0.8 mm thickness. zinc coating thickness on GSS shall be of minimum 220 GSM. ii) inner and outer side of the casing shall have noise absorbing polyethylene insulation with adequate thickness. iii) unit shall be provided wired remote controller and it should facilitate on/ off function, change of temperature settings, fan speed setting, operation mode setting, clock function and error code display ., including drain tray , the whole unit shall be fixed on ceiling with using suitable size anchor fastener and threaded rod etc -Ductable Unit 3.5 TR with inbuilt drain pump with remote controller. | 1 | each | 56,429.99 ₹56,429.99 Lowest | 57,000 ₹57,000 |
| 1.01 | OD4694/2025-2026:Supply, installation, testing and commissioning of 2.0TR High wall split air conditioner Unit with cordless remote compatible with VRF system suitable for operation single phase, 230 V, 50Hz supply including fixing of room unit drain connection with U-trap and all necessary fittings, elbows, structural supports etc. The item shall be complete in all respects complying to technical specifications- ISEER value 4.6 or above rated inverter type Hi-wall split air conditioner indoor unit complying to IS: 1391: 1992 (PartI & II) with up-to-date amendments. 2 TR single phase split A/C unit. | 5 | each | 29,254.5 ₹1,46,272.5 Lowest | 29,560 ₹1,47,800 |
| 1.01 | OD4663/2025-2026:Supply, installation, testing and commissioning of 1.5TR Hiwall air conditioner Unit with cordless remote compatible with VRF system suitable for operation single phase, 230 V, 50Hz supply including fixing of room unit drain connection with U-trap and all necessary fittings, elbows, structural supports etc. The item shall be complete in all respects complying to technical specifications- ISEER value 4.6 or above rated inverter type Hi-wall split air conditioner indoor unit complying to IS: 1391: 1992 (PartI & II) with up-to-date amendments. 1.5 TR single phase split A/C unit. | 11 | each | 28,393.19 ₹3,12,325.09 Lowest | 28,680 ₹3,15,480 |
| 1.01 | OD4716/2025-2026:Supply, installation, testing and commissioning of 1 TR Hiwall air conditioner Unit with cordless remote compatible with VRF system suitable for operation single phase, 230 V, 50Hz supply including fixing of room unit drain connection with U-trap and all necessary fittings, elbows, structural supports etc. The item shall be complete in all respects complying to technical specifications- ISEER value 4.6 or above rated inverter type Hi-wall split air conditioner indoor unit complying to IS: 1391: 1992 (Part I & II) with up-to-date amendments. 1 TR single phase split A/C unit | 5 | each | 23,789.7 ₹1,18,948.5 Lowest | 24,030 ₹1,20,150 |
| 1.01 | OD46122/2025-2026:Supply , installation , testing and commissioning of outdoor 'Y' joints | 3 | each | 15,360 ₹46,080 Lowest | 15,370 ₹46,110 |
Tender Value
₹59.3 L
EMD Value
₹50,000
Closing Date
2 Feb 2026, 6:00 pmClosed
Chief Electrical Engineer
Office of the Chief Electrical Engineer PWD Electrical Wing Public Office Thiruvananthapuram
DEPOSIT Replacement of damaged Digital VRF Outdoor and Indoor air conditioner units installed at Tax Towers Karamana SITC of Digital VRF air conditioner units Electrical AC Work
2026_PWD_830255_1
PWD/BLDG/TR/7163/2025
Open Tender
Electrical Works
Item Rate
240 days
Thiruvananthapuram
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,760
₹50,000
Yes
10 Mar 2026
23 Jan 2026
5 Feb 2026
23 Jan 2026
2 Feb 2026
23 Jan 2026
23 Jan 2026 - 2 Feb 2026
OD15755/2025-2026:Supply ,Conveyance, Loading , Installation, Testing and commissioning of 22 HP Modular type VRF OUTDOOR UNIT at roof top of the G+9 storied building including lifting and shifting of air conditioning system. The outdoor unit shall be factory assembled weather proof casting constructed from heavy gauge mild steel panels with epoxy coated painting and matching air cooled variable heat exchanger with copper tubes and aluminium fins duly covered by anti-corrosion and hydrophilic resin film. VRF outdoor unit shall comprise of high efficiency Hermetically sealed BLDC Inverter scroll/Twin rotary compressors . OEM should use there on make compressors in VRF/VRV system which is to be supplied. System COP shall not be less than 3.4 AT at AHRI condition and suitable to operate at heat load proportional to Indoor temperature requirement. Aluminium fins of condenser coil shall have anti corrosive epoxy resin ocean black coating along with hydrophilic coating precoated at factory.Anti corrosive treatment should have been tested for atleast 2500 Hrs of standard salt spray test.The treatment should be suitable for areas of high pollution and salt laden air. Modular system to be configured as per mention modules given in bracket.
OD4192/2025-2026:Supply, Installation, Testing & Commissioning of 6 TR high static DUCTABLE INDOOR UNIT suitable for VRV/VRF system including , indoor fan motors, electronic expansion valve that controls the flow of refrigerant in respond to the load variations of room according to set temperature, which can set by remote controllers. electricity characteristics for indoor unit shall be 240 volts/ 1phase / 50hz. i)casing shall be made of galvanized steel sheet (GSS) with minimum 0.8 mm thickness. zinc coating thickness on GSS shall be of minimum 220 GSM. ii) inner and outer side of the casing shall have noise absorbing polyethylene insulation with adequate thickness. iii) unit shall be provided wired remote controller and it should facilitate on/ off function, change of temperature settings, fan speed setting, operation mode setting, clock function and error code display ., including drain tray , the whole unit shall be fixed on ceiling with using suitable size anchor fastener and threaded rod etc -Ductable Unit 6 TR with inbuilt drain pump with remote controller.
OD45247/2025-2026:Supply, Installation, Testing & Commissioning of 4.6 TR high static DUCTABLE INDOOR UNIT suitable for VRV/VRF system including , indoor fan motors, electronic expansion valve that controls the flow of refrigerant in respond to the load variations of room according to set temperature, which can set by remote controllers. electricity characteristics for indoor unit shall be 240 volts/ 1phase / 50hz. i)casing shall be made of galvanized steel sheet (GSS) with minimum 0.8 mm thickness. zinc coating thickness on GSS shall be of minimum 220 GSM. ii) inner and outer side of the casing shall have noise absorbing polyethylene insulation with adequate thickness. iii) unit shall be provided wired remote controller and it should facilitate on/ off function, change of temperature settings, fan speed setting, operation mode setting, clock function and error code display ., including drain tray , the whole unit shall be fixed on ceiling with using suitable size anchor fastener and threaded rod etc -Ductable Unit 4.6 TR with inbuilt drain pump with remote controller.
OD45113/2025-2026:Supply, Installation, Testing & Commissioning of 4 TR high static DUCTABLE INDOOR UNIT suitable for VRV/VRF system including , indoor fan motors, electronic expansion valve that controls the flow of refrigerant in respond to the load variations of room according to set temperature, which can set by remote controllers. electricity characteristics for indoor unit shall be 240 volts/ 1phase / 50hz. i)casing shall be made of galvanized steel sheet (GSS) with minimum 0.8 mm thickness. zinc coating thickness on GSS shall be of minimum 220 GSM. ii) inner and outer side of the casing shall have noise absorbing polyethylene insulation with adequate thickness. iii) unit shall be provided wired remote controller and it should facilitate on/ off function, change of temperature settings, fan speed setting, operation mode setting, clock function and error code display ., including drain tray , the whole unit shall be fixed on ceiling with using suitable size anchor fastener and threaded rod etc -Ductable Unit 4 TR with inbuilt drain pump with remote controller.
OD45260/2025-2026:Supply, Installation, Testing & Commissioning of 3.5TR high static DUCTABLE INDOOR UNIT suitable for VRV/VRF system including , indoor fan motors, electronic expansion valve that controls the flow of refrigerant in respond to the load variations of room according to set temperature, which can set by remote controllers. electricity characteristics for indoor unit shall be 240 volts/ 1phase / 50hz. i)casing shall be made of galvanized steel sheet (GSS) with minimum 0.8 mm thickness. zinc coating thickness on GSS shall be of minimum 220 GSM. ii) inner and outer side of the casing shall have noise absorbing polyethylene insulation with adequate thickness. iii) unit shall be provided wired remote controller and it should facilitate on/ off function, change of temperature settings, fan speed setting, operation mode setting, clock function and error code display ., including drain tray , the whole unit shall be fixed on ceiling with using suitable size anchor fastener and threaded rod etc -Ductable Unit 3.5 TR with inbuilt drain pump with remote controller.
OD4694/2025-2026:Supply, installation, testing and commissioning of 2.0TR High wall split air conditioner Unit with cordless remote compatible with VRF system suitable for operation single phase, 230 V, 50Hz supply including fixing of room unit drain connection with U-trap and all necessary fittings, elbows, structural supports etc. The item shall be complete in all respects complying to technical specifications- ISEER value 4.6 or above rated inverter type Hi-wall split air conditioner indoor unit complying to IS: 1391: 1992 (PartI & II) with up-to-date amendments. 2 TR single phase split A/C unit.
OD4663/2025-2026:Supply, installation, testing and commissioning of 1.5TR Hiwall air conditioner Unit with cordless remote compatible with VRF system suitable for operation single phase, 230 V, 50Hz supply including fixing of room unit drain connection with U-trap and all necessary fittings, elbows, structural supports etc. The item shall be complete in all respects complying to technical specifications- ISEER value 4.6 or above rated inverter type Hi-wall split air conditioner indoor unit complying to IS: 1391: 1992 (PartI & II) with up-to-date amendments. 1.5 TR single phase split A/C unit.
OD4716/2025-2026:Supply, installation, testing and commissioning of 1 TR Hiwall air conditioner Unit with cordless remote compatible with VRF system suitable for operation single phase, 230 V, 50Hz supply including fixing of room unit drain connection with U-trap and all necessary fittings, elbows, structural supports etc. The item shall be complete in all respects complying to technical specifications- ISEER value 4.6 or above rated inverter type Hi-wall split air conditioner indoor unit complying to IS: 1391: 1992 (Part I & II) with up-to-date amendments. 1 TR single phase split A/C unit
OD46122/2025-2026:Supply , installation , testing and commissioning of outdoor 'Y' joints
OD4787/2025-2026:Charges for suppling and filling the R410A refregerent gas in the air conditioning system
OD147974/2025-2026:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC shielded communication cabling between VRV/VRF indoor and outdoor units 650/1100 V grade copper conductor flexible cables in the existing surface / recess conduit as required including giving necessary connections of the following sizes. 2 core 1.50 sq mm
OD227048/2025-2026:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes. 4 core 10.00 sq mm
1.17.33:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 6 sq. mm
90.6.4.56:Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.10.00 sq.mm 6 Run
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.21.3:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm
OD259525/2025-2026:Supply ,laying and fixing of one number PVC insulated and PVC sheathed / XLPE Aluminium conductor power cable of 1.1 KV grade conforming to IS 1554/(part I)/1988 for PVC & IS 7098/(part I)/1988 for XLPE of following size on wall surface as required. 4x16 sqmm (clamped with 1mm thick saddle)
OD46126/2025-2026:Supplying and fixing TPN sheet steel enclosure on surface/ recess along with 40A amps four pole isolator complete with connections, testing and commissioning etc. as required.
9.2.29:Supplying and making outdoor end termination with cast resin compound including aluminium lugs and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm
OD152237/2025-2026:Dismantling charges for the existing VRF outdoor units and damaged ducts from 9th floor to ground floor, without further damage, shifting the same using crane, skilled labours and supporting tools etc and removing storing all other accessories to section store.
OD46389/2025-2026:Charges for dismantling of existing VRF Indoor units and its connected damaged copper pipes and transportation to store as directed by the engineer in charge.
OD151197/2025-2026:Supply,installation,testing and commissioning of cu refrigerant piping with 18g Hard drawn copper pipes, insulated with 19 mm thick nitrile rubber tubing finished with glass cloth poly shield coating of approved make inclusive of proper supports 53.98 mm dia
OD100710/2025-2026:Supply,installation,testing and commissioning of cu refrigerant piping with 18g Hard drawn copper pipes, insulated with 19 mm thick nitrile rubber tubing finished with glass cloth poly shield coating of approved make inclusive of proper supports 41.3mm dia
OD151198/2025-2026:Supply,installation,testing and commissioning of cu refrigerant piping with 18g Hard drawn copper pipes, insulated with 19 mm thick nitrile rubber tubing finished with glass cloth poly shield coating of approved make inclusive of proper supports 38.9 mm dia
OD100713/2025-2026:Supply,installation,testing and commissioning of cu refrigerant piping with 18g Hard drawn copper pipes, insulated with 19 mm thick nitrile rubber tubing finished with glass cloth poly shield coating of approved make inclusive of proper supports 31.8 mm dia
OD100717/2025-2026:Supply,installation,testing and commissioning of cu refrigerant piping with 18g Hard drawn copper pipes, insulated with 19 mm thick nitrile rubber tubing finished with glass cloth poly shield coating of approved make inclusive of proper supports 25.4 mm dia
OD100718/2025-2026:Supply,installation,testing and commissioning of cu refrigerant piping with 18g Hard drawn copper pipes, insulated with 19 mm thick nitrile rubber tubing finished with glass cloth poly shield coating of approved make inclusive of proper supports 22.2 mm dia
OD100732/2025-2026:Supply,installation,testing and commissioning of cu refrigerant piping with 18g Hard drawn copper pipes, insulated with 19 mm thick nitrile rubber tubing finished with glass cloth poly shield coating of approved make inclusive of proper supports 19.5 mm dia
OD100735/2025-2026:Supply,installation,testing and commissioning of cu refrigerant piping with 18g Hard drawn copper pipes, insulated with 19 mm thick nitrile rubber tubing finished with glass cloth poly shield coating of approved make inclusive of proper supports 15.9 mm dia
OD100779/2025-2026:Supply,installation,testing and commissioning of cu refrigerant piping with 18g Hard drawn copper pipes, insulated with 19 mm thick nitrile rubber tubing finished with glass cloth poly shield coating of approved make inclusive of proper supports 12.7mm dia
OD100783/2025-2026:Supply,installation,testing and commissioning of cu refrigerant piping with 18g Hard drawn copper pipes, insulated with 19 mm thick nitrile rubber tubing finished with glass cloth poly shield coating of approved make inclusive of proper supports 9.52 mm dia
OD100792/2025-2026:Supply,installation,testing and commissioning of cu refrigerant piping with 18g Hard drawn copper pipes, insulated with 19 mm thick nitrile rubber tubing finished with glass cloth poly shield coating of approved make inclusive of proper supports 6.35 mm dia
OD151350/2025-2026:Charges for Replacing Pipe Insulation with Glass coat wrapping and paint posture etc as required.
4.1.4:Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 300 mm width X 50 mm depth X 1.6 mm thickness
16.12.2.1:Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required.Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.63 mm thick
16.12.2.2:Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required.Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.8. mm thick
OD103288/2025-2026:Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (class "O") insulation on existing duct after applying two coats of cold setting adhesive (CPRX compound). The joints shall sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required.Nitrile rubber insulation - 19 mm
16.15:Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.
16.16:Supplying & fixing of powder coated extruded aluminum Return Air Grills with louvers but without volume control dampers complete as required.
OD233261/2025-2026:Supplying, fixing, testing and commissioning of fresh air dampers in supply air duct/ main branch complete with volume control dampers
OD45564/2025-2026:Supply and fixing ofthe fire retardant type canvas for interconnecting cooling unit with duct/plenum and fixed in front area to avoid excess vibration with required accessories.
OD100957/2025-2026:Supply,installation,testing and commissioning of insulated condensate drain piping out of PVC-6kg/cm2 pipes complete with hangers/ supports/ clamps/clips and all fittings etc and insulated with 13 mm thoick nitrile rubber sleeves and joints sealed with 50 mm black PVC tapes-32 mm dia
OD151219/2025-2026:Supply and providing 200 X 145 X 95 size Sintex /Henel Box for fixing Isolator with din rail and giving connections etc. as required.
90.10.3.15:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator
90.10.3.33:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket
90.10.3.32:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3 pin plug top with indicator
90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
14.7:Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required.
14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels
14.72:Providing and fixing double scaffolding system (cup lock type) on the exterior side, upto seven story hight made with 40 mm dia. M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staricase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required location with essential safety features for the workmen etc. complete as per directions and approval of Engineer- in Charge. The elevational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding. Note:- This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done .
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1394805.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.04 MB
SBD.pdf
Tender Documents • 1.63 MB
MOM.pdf
Tender Documents • 0.28 MB
BOQ_1394805.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .