Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.1 LAccepted-AOC INDEX NO E 72 HQ CWE HILLS VILL PO MEHUWALA MAPHI NEAR RAJKIYA INTER COLLEGE DEHRADUN UK | DEHRADUN | UTTARAKHAND | 248001 | L1 | Accepted-AOC Acceptance of contract | |
| 2 | L2₹28.9 L+₹2.0 L (7.60%)Rejected-AOC INDEX NO E 1504 HQ CWE DEHRADUN 63 RAJA ROAD DEHRADUN | L2 | Rejected-AOC R | |
| 3 | L3₹30 L+₹3.1 L (11.7%)Rejected-AOC WING NO 7 2 10 PREMNAGAR DEHRADUN UK | L3 | Rejected-AOC R | |
| 4 | L4₹31.9 L+₹5.0 L (18.6%)Rejected-AOC 27 CHITRAKOOT ENCLAVE NEAR ANURAG NURSARY DEHRADUN 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L4 | Rejected-AOC R | |
| 5 | L5₹32.3 L+₹5.4 L (20.3%)Rejected-AOC 381 2 SATYA VIHAR MANDIR MARG VIJAY PARK DEHRADUN 248001 UK | DEHRADUN | UTTARAKHAND | 248001 | L5 | Rejected-AOC R |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
3 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE IMA Dehradun
GE IMA Dehradun
REPAIR AND MAINT OF TRAINING ACADEMIC BLOCK INCLUDING ALLIED INFRASTRUCTURE UNDER AGE BR I AT IMA DEHRADUN
2023_MES_593592_1
GE/IMA/T-12 2023-24 9301/E8
Open Tender
Support/Maintenance Service
Item Rate
180 days
GE IMA Dehradun
Refer NIT
8 documents required · 8 mandatory
₹500
Yes
GE IMA Dehradun
₹80,000
Yes
19 Jul 2023
6 May 2023
5 Jun 2023
7 May 2023
3 Jun 2023
20 May 2023
Amount
Providing and fixing plain gypsum board false ceiling made out of 12.5mm thick paper reinforced gypsum board sheets fixed with main frame channel 80mmx 26mm x 0.5mm thick at every 450mm center to center, intermediate channel of size (15mm x 45mm x 0.9mm) at every 1220mm center to center with perimeter channel 20mm x 26mm x0.5mm all along the wall shall be provided. The frame work to be suspended with strap hangers 25mm x 0.5mm from intermediate channels using GI cleat & steel expansion fastnor at slab soffit. Arrangements are to be made to accommodate light fixtures by forming recessed channel, cutting etc wherever directed. Depression, nails & screws, jointing & finishing shall be done with jointing compound including applying two coats of oil emulsion paint over a coat of primer and one coat of putty.Note :- The rates are inclusive of scaffolding upto 7.5m height.
S & F Providing & fixing plain gypsum board made out of 12.5mm thick paper reinforced gypsum board sheets in ceiling on existing frame work/grid including straightening of existing frame work. Arrangements are to be made to accommodate light fixtures by forming recessed channel, cutting etc wherever directed. Depression, nails & screws, jointing & finishing shall be done with jointing compound including applying two coats of oil emulsion paint over a coat of primer and one coat of putty. Note :- The rates are inclusive of scaffolding upto 7.5m height.
S & F Pre- painted colour galvalume aluminium Zinc coating GI based corrugated tile profile steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa having 150 GSM as in roof covering/cladding to wall, ridges fixed with self tapping screws etc complete all as directed including dismantling existing sheet.
S&F Pre- painted colour galvalume aluminium Zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa having 150 GSM as in roof covering/cladding to wall, ridges fixed with self tapping screws etc complete all as directed including dismantling existing sheet.
Taking down damaged boards/plywood with frame of cupboards,bath cabinets,wall paneling etc including fillets etc of any description,complete all as specified and directed.
S&F 5 mm thick PVC sheet fillet of width 35 mm for wall paneling inclusive of fixing on to wall to make PVC frame as per specification and drg complete all as specified and directed
S&F in repairs 5mm thick prelaminated PVC sheet in strips and channel feathered at the edges for fixing on solid PVC Partitions inclusive of solvent cement and fixing at site all as specified and directed.
S&F Non anodised aluminium rectangular hollow sections of size 50x25mm for frame work of cupboards/showcase,wall paneling grade to be placed at suitable distances as per site requirement fix with machine screws including rawel plugs,clamps etc all as specified and directed.
M&L for 9mm thick plywood 5ply grade BWP,type BB,fixed with nails to frame work as in wall paneling all as specified and directed.
M&L for 3mm thick 3ply vennered decorative plywood grade 1 (with BWR Resins) with decorative face venerrs on one face,fix with nails to frame works all as specified and directed.
M & L for Granite stone ( Lakha red) (table rubbed & polished) for wall lining (veneering to wall) 12-15mm thick with and including 15 mm thick rendering in cement mortar (1:3) and jointed with grey cement slurry, and pointed with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite stone including dismantling of existing stone slabs & cement mortar bedding and rubbish off the premises complete all as directed. Note : Any additional fittings such as clamps, screws required to hold the granite on vertical position deemed to be included in the rate.
M & L for 16 to 18mm thick “ Udaipur green” stone, as in flooring,steps, cooking platforms and like set in and including 15 mm thick screed bed in cement mortar (1:4) including pointing in colour cement 1:2 using marble dust with admixture of pigment to match with shade of stone including rounding of exposed edges of udaipur green stone and demolition of existing stone slabs including cement mortar bedding and rubbish off the premises complete all as directed.
M & L for 16 to 18mm thick “Jaisalmer stone” patti as in flooring and like set in and including 15 mm thick screed bed in cement mortar (1:4) including pointing in colour cement 1:2 using marble dust with admixture of pigment to match with shade of stone including rounding of exposed edges of udaipur green stone and demolition of existing stone slabs including cement mortar bedding and rubbish off the premises complete all as directed.
Demolition of cement concrete un-reinforced in ground floor and pavings n.exc 15Cm thick (below or above ground level) including removal of demolished material outside the IMA premises complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding etc (but not backing) and removing including removal of demolished material outside the IMA premises complete all as specified and directed.
M&L for PCC 1:2:4 type B-0 (using 12.5 mm graded crushed stone aggregate) as in sub base flooring 25 mm thick surface finished even and smooth without using extra cement to receive the topping layer complete all as specified and directed.
M&L for glazed ceramic coloured tiles in vertical surface 450 x 300 x 6 to 7 thick, set and jointed in neat cement slurry and pointed in grout to match surface of tiles including 10mm thick rendering in cement mortar 1 :4 complete all as specified and directed.
M&L for Non Skid ceramic tiles 7 to 8 mm thick(square/ rectagular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm , in floors etc. set and jointed in tile epoxy grout to match including 20mm thick screed bed in cement mortar 1 :6 complete all as specified and directed.
All as per item No. 18 above on but vertical surfaces area of each tile exceeding 0.11 Sq m but not exceeding 0.18 Sqm as in skirting non skid ceramic tiles ncluding 10 mm thick rendering in cement mortar 1:4 complete all as specified and directed.
M&L for Vitrified ceramic tile planks size 195x1200mm wooden colour (dark shade) 7-8 mm thick polished, laid in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles with and including 15 mm thick screed bed or bedding layer in cement mortar 1:4 complete all as specified and directed.
M&L for Machine cut kota stone slab flooring mirror finished 18-20 mm thick (each slab not less than 0.25 Sqm) over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab with 20 mm thick screed bed or bedding layer in cement mortar 1:4, including rubbing and minor polishing complete all as specified and directed.
M&L for Machine cut kota stone in riser of steps, skirting, dado and pillar mirror finished 18-20 mm thick over cement base rendering laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab with 15 mm thick screed bed or bedding layer in cement mortar 1:4, including rubbing and minor polishing complete all as specified and directed.
Cutting and grinding of existing Granite/kota stone floor surface(2cut) on horizontal and vertical surface and finally finishing the surfaces uniformally by applying floor polish complete all as specified and directed by Engr-in-Charge.
M&L for double action floor spring hydraulically regulated made up of min 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed in repair in aluminium doors complete all as specified & directed.
M& L for PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, coping, benching, kneelers, apex stone, bed plates, kerbs, etc. including weathering, slightly rounded or chamfered angles and throating, including necessary from work etc including demolition of existing cement concrete complete all as directed.
M&L for 75 mm thick PCC 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in plinth protection or similar places and finishing the surface even & smooth with out using extra cement uisng 38mm width PVC dividing strip,3 mm thick including demolition of existing old cement concrete, complete all as specified and directed. Note :- PVC strip shall be measured and paid separately as supply only.
Supply only 38mm thick PVC dividing strip of 3mm thick
S&F 80mm thick Heavy duty Factory made Precast RCC M-30 as in drain cover slab reinforced with 10mm TMT bars and providing hook duly black painted set and jointed in cement mortar 1:4 incl demolition of existing old RCC slabs of any description complete all as directed. Make:- Ferrocon/Sagr tiles/ Tulip
Hacking out old broken glass panes of any thickness and size from wooden/metal frame including punching or drilling and glazing pins etc and fixing of 5.0 mm thick glass fixed in aluminium door/window/partition fixed with rubber gasket and aluminium beading complete all as directed.
Taking down chowkhats or frame with shutters (without taking off shutters from the frames) area n.exc 1.5 Sqm each complete all as specified and directed.
Taking down chowkhats or frame with shutters (without taking off shutters from the frames) area .exc 1.50 Sqm and n.exc 4.00 Sqm each complete all as specified and directed.
Taking down shutter of any description n.exc 1 Sqm each complete all as specified and directed
Taking down shutter of any description exc 1 Sqm and not exc 2 sqm each complete all as specified and directed.
S&F Solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube supplying and fixing in opening as per specification and drawing in SSR complete all as specified and directed.
S&F Factory made solid panel PVC door shutter 30mm thick(style) consisting of frame made out of MS tubes for top & bottom rails MS frame shall be covered with heat moulded plain colour PVC "C" channel having a pvc sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail lock rail & bottom rail on either side and as gap insert for top rail & bottom rail. Panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement suppling & fixing in the frame at site as per specification & drawing in SSR Part II 2010 etc complete all as specified and directed.
Supply and fix 12mm thick plywood grade BWR,type BB,including fixing new wooden beading and applying one coat of synthetic clear varnish on varnished wooden surfaces of any description over 10Cm width or girth including taking down of unservicieable particle board panel as specified and directed.
M&L in repairs Urinal, bowl type flat back size of 375 x 390 x 590 mm snow white (minimum) with grating and union for discharge pipe complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement etc complete all as sapecified and directed by Engr-in-Charge.
S&F table top WHB basin thin rim snow white coloured complete all as specified and directed by Engr-in-Charge.
S&F CP pillar tap long extended body for table top with aerator including all fitting and fixtures all specified and directed.
S&F CP Angular stop cock 15mm complete all as specified and directed.
S&F PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed.
S&F in repairs for wall hung Vitrous china wash down water closet (EWC) with seat cover and twin flush fittings colour snow white including all accessories such as flushing cistern,P or S type,pvc connection complete all as specified and directed.
S&F in repairs PVC 10 litres capacity valveless ,syphonic action type low level flushing cistern ,white including flush pipe, cantilever brackets ,inlet, ball valve, float and handle, PVC connection 15mm dia etc complete all as specified and directed.
S & F in repairs health faucet with fluxi pipe and hand shower ,the length of hose 1.50mt fitted to the angle cock complete.
Taking up or down GI steel tubing and connections including cleaning for refixing required for 15 mm bore of pipe complete all as specified and directed.
Taking up or down GI steel tubing and connections including cleaning for refixing required for 20 mm bore of pipe complete all as specified and directed.
Taking up or down GI steel tubing and connections including cleaning if refixing required for 25 mm bore of pipe complete all as specified and directed.
S&F GI tubes medium grade with all fittings fixed to walls and ceilings or laid in floors of 15 mm bore of pipe complete all as specified and directed.
S&F GI tubes medium grade with all fittings fixed to walls and ceilings or laid in floors of 20 mm bore of pipe complete all as specified and directed.
S&F GI tubes medium grade with all fittings fixed to walls and ceilings or laid in floors of 25 mm bore of pipe complete all as specified and directed.
Refixing old steel tubing and connections with new GI fittings in new or old position (wall, floor, ceiling etc) of 15 mm bore of pipe complete all as specified and directed.
Refixing old steel tubing and connections with new GI fittings in new or old position (wall, floor, ceiling etc) of 20 mm bore of pipe complete all as specified and directed.
Refixing old steel tubing and connections with new GI fittings in new or old position (wall, floor, ceiling etc) of 25 mm bore of pipe complete all as specified and directed.
S&F Chromium plated pillar tap for counter top wash hand basin all as specified and directed.
S&F in repairs PVC waste pipe for urinal/WHB/sink complete all as specified and directed.
S&F chromium plated toilet paper holder with flap complete all as specified and directed.
S&F in repairs Waste fittings 32 mm dia, brass, chromium plated for sinks/basins etc with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified and directed.
S&F 100mm dia chromium plated grating with/without hole fixed in repairs complete all as specified and directed.
Demolition and breaking up drain pipe (salt glazed ware, AC or reinforced concrete ) set in cement mortor for 100 mm internal dia of pipe including removal of demolished material out side IMA premises, complete all as specified and directed.
M&L for PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors of 75 mm bore of pipe etc complete all as specified and directed.
M&L for PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors of 110 mm bore of pipe etc complete all as specified and directed.
S&F PVC (SWR) bends any radius of 75 mm bore with out access door complete all as specified and directed.
S&F PVC (SWR) bends any radius of 110 mm bore with out access door complete all as specified and directed.
S&F PVC (SWR) bends any radius of 110 mm bore with access door complete all as specified and directed.
S&F PVC (SWR) bends any radius of 75 mm bore with access door complete all as specified and directed.
S&F PVC (SWR) vent cowl 110 mm bore complete all as specified and directed.
S&F PVC (SWR) vent cowl 75 mm bore complete all as specified and directed.
S&F PVC connection 15 mm size with PTMT nuts of length 600 mm complete all as specified and directed.
S&F chromium plated towel rail 600 mm long,25mm dia of fixed with and including chromium plated brass screws complete all as specified and directed..
S&F chromium plated soap dish any type fixed in repairs complete all as specified and directed
M & L in repairs water proofing treatment on roof slab including picking,sweeping cleaning and washing down with water to remove dust & providing water proofing described as under :- (a) Surface prepration with polymer modified mortar,GP grout mortar & treating of construction joint ,filling of honey combs. (Cement : Sand (crasher stone dust): multipurpose polymer of asian /sikka/Berger (b) cleaning the surface and applying ( Resin & Hardner ) Epoxy Primer Sikka /Asian/Berger ) on the cleaned surface for bonding of rubbished polyurethane based coating with the existing concrete surface.(c) Supplying,providing & applying water proofing treatment to Terrace area rubberised polyutherene based coating,single component highly elastomeric seamless cold applied modified PU coating or equivalent product of sikka/Berger/Asian) including all necessary surface prepration,coving using multipurpose polymer,water pont test etc.complete as per manufacturer's specifications and aapplication methodology.The same coating shall be applied in two coats achieving a total thickness of 1.0mm thick.The coating shall have dual combination of 250% elongation,complete all as specified and directed. Make:Sikka/Berger/Asian Paint LTd,as recommended by Engr-In-charge and as approved by GE. Note:-(a) Work shall be executed through autrhorised applicator of manufacturer only as per manufacturer's instructions and upto roof height of triple storied building (c) stage passing shall be approved by Engineer-in-Charge and GE approving. 03 years manufacturer's guarntee shall be given by the contractor.Work will be executed in smart assurance system complete all as specified and directed.
M&L for 20mm thick plaster using ready mix plaster over roof mixed with (Water proofing compound) (Liquid) as per manufacturer's instructions including brushing neat cement slurry @ 3 Kg/Sqm over old RCC roof including taking down existing plaster on roof complete all as specified and as directed. Note : Water proofing compound (liquid) shall be measured and paid seperately. Make:- ACC/Utratech/Birla/ Unicrete.
Taking down cement plaster on brick or stone walling built in cement mortar including raking out joints hacking for key scrubbing down with water etc including removal of demolished material outside the IMA premises complete all as specified and directed.
M&L for Brick work with sub class 'B' bricks (old size) straight or curved on plan exc 6.00m mean radius built in cement mortar (1:6) including demolition of brick work/stone masonry built in cement mortar including removal of demolished material outside at IMA premises,complete all as specified and directed.
M&L for Brick work with sub class 'B' bricks (old size), straight or curved on plan to any radius in half brick thick wall built in cement mortar (1:4) including demolition of brick work/stone masonry built in cement mortar complete all as specified and directed.
M&L for Rendering 12 mm thick using ready mix plaster on brick or concrete surface surfaces finish even and smooth complete all as specified and directed. Make:- ACC/Birla/Ultratech/Unicrete.
M&L for Rendering 15 mm thick using ready mix plastering on brick or concrete surface finish even and smooth complete all as specified and directed. Make:- ACC/Birla/Ultratech/Unicrete.
Supply only liquid water proofing compound complete all as specified & directed.
M&L for protective measure to kill termite family and growth on ceiling,wall,inside cupboards and similar termite infected surfaces by spraying anti termite chemical @ 0.50 ltr per sqm of rich emulsion of approved chemical,complete all as specified and directed.
M&L for preparation of old plastered/un-plastered surfaces of wall by brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots including cornices, pillar etc and applying one coat of white wash on walls complete all as specified and directed.
M&L for preparation of old plastered/un-plastered surfaces of ceiling by brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots including cornices etc and applying one coat of white wash on ceiling complete all as specified and directed.
M&L for Preparation of old plastered/unplastered surfaces of wall and applying one coat of weather exterior emulsion paint (Apex paint of Asian Paint / Weather proof of berger) complete all as directed. Note : The work shall be carried out upto 18m height. The rates are inclusive of scaffolding. Note:- The painting work is to be carried out by mechanical means after covering the adjoing areas/window/floor by using paper/plastic and mask tape etc.
M&L for preparation of old plastered surfaces of walls by brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying one coat of oil emulsion distemper on walls complete all as specified and directed. Note:- Work to be carried out by mechanical means as per manufacturer's instruction.
M&L for preparation of old plastered surfaces of ceiling by brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying one coat of oil emulsion distemper on walls complete all as specified and directed. Note:- Work to be carried out by mechanical means as per manufacturer's instruction.
M&L preparation of new plastered surfaces of wall and applying two coats of weather proof exterior emulsion paint (Apex of Asian/Weather proof of Berger) all as directed. Note:- The painting work is to be carried out by mechanical means after covering the adjoing areas/window/floor by using paper/plastic and mask tape etc.
M&L preparation of new plastered surfaces of wall and applying two coats of oil bound emulsion over a coat of chalk whitening complete all as directed. Note:- Work to be carried out by mechanical means per manufacturers instruction.
Complete removing of existing treatment from wall / ceilling surface by scrapping with mechanical means complete all as specified and directed. (work to be carried upto a height of 7.50m high)
Preparation of scrapped surface of wall / ceiling and applying 1-1.50mm thick Asian acrylic damp proof wall care putty as per manufacturer's instructions complete all as specified and directed. (work to be carried upto a height of 7.5m).
M&L for preparation of putty surfaces of wall/ceiling and applying one coat of primer complete all as specified and directed.(work to be carried upto a height of 7.5m).
M&L for preparation of primed surfaces of wall / ceiling and applying two coats of Oil bound distemper complete all as specified and directed. Note:- Painting work is to be done as per mechnical means as per manufacturer's instructions.
M&L for preparation of existing varnished wooden surfaces of any description over 10cm width or girth and applying one coat of synthetic clear varnish complete all as specified.
Taking down carefully existing aluminum/copper surface/concealed point wiring (light, fan, socket or power point) complete of any description including fitting such as switches, ceiling roses, regulators, sockets, wooden boards, laminated sheets from sunken boxes, boards, holders and making good the disturbed surfaces in cement mortar 1:3 of walls, floors, ceiling etc including distempering to match with existing surfaces complete all as specified and directed.
S& F modular fitting /fixture including taking down old unsv fitting/fixture of following specification : Make: Anchor,Havells,Legrand
Fan regulator modular step type 120W 240 volts 2 module.
Modular switch single pole one way 6/10 Amp 240 volts.
Modular switch single pole one way16/ 20 Amp 240 volts .
Modular socket outlet 2/3 pin combined 6/10 Amp 240 volts.
Modular socket outlet 2/3 pin combined 16/ 20 Amp 240 volts.
S&F in repairs white modular cover plate with frame of following module complete including taking down old unsv modular cover plate with frame all as directed:- Make: Anchor,Legrand, Havells
1Module
2Module
3Module
4Module
6Module
8 Module
12 Module
S&F modular metal flush box of following module complete all as directed. Make: Anchor, Legrand, Havells
1Module
2Module
3Module
4Module
6Module
8 Module
12 Module
Taking down carefully existing surface /conceled light fitting from any height of any wattage /description by disconnecting the wire and set aside insafe custody for reuse and refixing in same postion after completion of work all as specified and directed.
Taking down carefully existing ceiling fan from any height of any capacity/description by disconnecting the wire and set aside insafe custody for reuse and refixing in same postion after completion of work all as specified and directed.
Taking down carefully existing Exhaust Fan /Cabin fan /wall mounted fan from any height of any capacity/description by disconnecting the wire and set aside insafe custody for reuse and refixing in same postion after completion of work all as specified and directed.
Taking down carefully existing storage type water heater(geyser) from any height of any capacity/description by isolating electric/water supply and set aside insafe custody for reuse and refixing in same postion after completion of work all as specified and directed.
Taking down carefully existing switch board including acessories such as switches, sockets ,regulators of any capacity/description disconnecting the wire and set aside insafe custody for reuse and refixing in same postion after completion of work all as specified and directed.
S&F ceiling rose, 63.5 mm dia, ISI marked, three terminal of polycarbonate/isolated body including taking down old unsv ceiling rose complete all as directed. Make: Anchor Penta PC, Havells (Reo)/Legrand
S&F Electronic steppped type fan regulator 100 watt 230 volts AC 50 Hz including taking down old unsv fan regulator complete all as directed. Make:Anchor Penta PC, Havells (Reo)/Legrand
S&F Batten holder, PVC/polycarbonate type with back plate suitable for batten fittings including taking down old unsv batten holder complete all as directed. Make: Anchor Penta PC, Havells (Reo)/Legrand
S&F switch piano, flush type, single pole one way 6 Amp including taking down old unsv switch complete all as directed. Make: Anchor Penta PC, Havells (Reo)/Legrand
S&F switch piano, flush type, single pole one way 16Amp including taking down old unsv switch complete all as directed. Make: Anchor Penta PC, Havells (Reo)/Legrand
S&F socket out let, multipurpose, 2 in 1 5 pin, 6 Amp including taking down old unsv socket complete all as directed. Make: Anchor Penta PC, Havells (Reo)/Legrand
S&F socket out let, multipurpose, 2 in 1 5 pin, 16 Amp with fuse and neon indicator including taking down old unsv socket complete all as directed. Make:Anchor Penta PC, Havells (Reo)/Legrand
S&F Electronic step rotary type fan regulator 1000 watt 230 volts AC 50 Hz including taking down old unsv fan regulator complete all as directed. Make: Anchor Penta PC, Havells (Reo)/Legrand.
S &F Bakelite sheet cover 3 mm thick cut as required shape and size including brass screws and cup washer off following size for mounting swich, socket fan regulator etc including taking down existing unserviceable bakelite sheet cover complete all as directed:- Make: Hylam, Woodlite,Havells.
S & F Circuit/submain wiring with single core FR-LSH PVC insulated copper multi stranded conductor cable drawing into existing PVC rigid conduit in surface/concealed as required, including taking down unserviceable existing wiring etc complete of following sizes as directed:- Make: Havells/ Polyacab /Grandlay/
S & F pressed steel sunken terminal boxes 1.6 mm thick, 60 mm including brass screws and cup washer of following size for mounting switch, socket fan regulator etc including taking down existing the existing unserviceable sunken terminal boxes complete all as directed :-
Material and labour for point wiring with PVC insulated and unsheathed electric cable 1100 volts grade single core FRLSH having multi stranded copper conductor of 1.5 sq mm nominal cross sectional area drawn in nincluding non rigid PVC Conduit concealed in wall with all fitting and fixing accessories and 1.5 sq mm PVC insulated unsheathed multistranded copper conductor cable as continuous earth conductor, connected to earth dolly by providing suitable lugs with & including modular metal flush box of required size factory made for mounting Modular switch, regulators etc with and including Modular cover and frame , ISI marked, for the following. Make of wire:Havells/ Polyacab /Grandlay/Anchor Make of conduit: AKG Plastic Pvt Ltd./Bhagwati Plastic & Agriculture industry /Polycab Note (i) The quoted rates shall be deemed to be inclusive for cutting chasing in wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing by applying one coat of putty and two coat of Distemper to the surface to match with the existing surface.The portion of point wiring at ceiling shall be in surface conduit of suitable size fixed on ceiling surface with using PVC rawl plugs. (ii) Point wiring & earth wire shall be connected to each & every sunken box. (iii) All screws, fasteners, bolts, nuts & washer shall be cadmium plated & the cost of which is deemed to be included in the quoted unit rates. (iii) 1 x 5 Amps Independent board in one circuit of 1.5 sqmm and 1 x 16 Amps Socket board in one circuit of 2.5 sqmm / 4 sqmm be made. (iv) Wiring insulation test result sheet after or before carryng out the internal wiring must be recorded by contractor and the rate for the same deemed to be inclusive in the quoted rate. .
One light point controlled by one, one way 6 Amp modular switch.
One fan/exhaust fan point controlled by one, one way 6 Amp modular switch.
One 5 pin 5/6 Amps socket outlet point on the same board
One 5 pin 5/6 Amps socket outlet point on independent board
Description all as per item 144 here-in-before but point wiring with 4 Sqmm multistrand copper conductor cable for one six pin socket outlet 15 Amps controlled by one switch on independent board and 4 Sqmm PVC insulated multistranded copper conductor cable as continous earth wire.
S & F Modular switch single pole one way 6 Amp fixed complete all as directed. Make: Anchor, (Penta) Legrand, Crabtree (Havells)
S & F Modular switch and socket outlet 2/3 pin combined 6 Amp 240 volts fixed complete all as directed. Make: Anchor (Penta), Legrand, Crabtree (Havells)
S & F for Modular switch and socket single pole one way 16 Amp complete all as directed. Make: Anchor (Penta), Legrand, Crabtree (Havells)
Supply and Fixing in repair LED Batten light fittings on walls including connected the same with using PVC sheathed , insulated 3 core flexible 23/0.0076 copper cable including fixing arrangement for fixing the light fitting to ceiling rose all as conforming to the following parameters including taking down old unsv Light fitting: - (i) Lumens: -system lumen not less than 2850 lm (ii) Housing: - Highquality batten with extruded aluminium with Powder coated. (iii) IP Rating: - IP 20 (v) Mounting: - Wall Mounted (vi) Finish: - Polycarbonated diffuser (vii) Lamp: - High bright LED (viii) System Efficacy (lm/W) of the luminaries: - Not less than 130 lm/watt. (ix) Colour temperature (K): - Not less than 5700( COOL DAY LIGHT) (x) Color Rendering Index (CRI): - Not less than 80 (xi) Life: - Not less than 50000 Hrs of operation (xii) Optics: - Fully Diffused (xiii) Control gear: - inbuilt electronic driver, PF not less than 0.90 and THD less than 20 % with operating voltage 100-300V AC, 50 Hz (xiv) Surge protection: - inbuilt surge protection minimum 4 KV (xv) Heat Shink: - As per OEM's design Make: - Philips/Crompton/Havells/Bajaj
Supply and Fixing LED Batten light fittings 2 Feet on walls including including connected the same with using PVC sheathed , insulated 3 core flexible 23/0.0076 copper cable including fixing arrangement for fixing the light fitting to ceiling rose all as conforming to the following parameters including taking down old unsv Light fitting: - (i) Lumens: -System lumen not less than 1200 lm (ii) Housing: - High pressure die cast aluminium. (iii) IP Rating: - IP 20 (v) Mounting: - Wall Mounted (vi) Finish: - Polycarbonated diffuser (vii) Lamp: - High bright LED (viii) System Efficacy (lm/W) of the luminaries: - Not less than 100 lm/watt. (ix) Colour temperature (K): - Not less than 5700(COOL DAY LIGHT) (x) Color Rendering Index (CRI): - Not less than 80 (xi) Life: - Not less than 50000 Hrs of operation (xii) Optics: - Fully Diffused (xiii) Control gear: - inbuilt electronic driver, PF not less than 0.90 and THD less than 20 % with operating voltage 100-300V AC, 50 Hz (xiv) Surge protection: - inbuilt surge protection minimum 4 KV (xv) Heat Shink: - As per OEM's design Make: - Crompton/Havels/Bajaj/Philips.
Amit Traders
M/S S P BUILDERS
M/S PUNDIR BUILDERS
Aron Water Proofing and Pest Control
Meher enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .