| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.2 CrAccepted-AOC | ₹3.2 Cr | L1 | Accepted-AOC agreement executed |
| 2 | L2₹3.3 Cr+₹9.2 L (2.84%)Rejected-Finance | ₹3.3 Cr+₹9.2 L (2.84%) | L2 | Rejected-Finance not lowest amount |
Tender Value
₹2.9 Cr
EMD Value
₹1 L
Closing Date
22 Aug 2020, 6:00 pmClosed
Project Director, PMU RKI LSGD
4th Floor, Saphalayam Complex, Palayam, Thiruvananthapuram 695034
Renovation of TV Puram Theeradesa Road in TV Puram GP in Kottayam District
2020_LSGD_376115_4
A1/142/2020/PMULSGD
Open Tender
Civil Works - Roads
Item Rate
240 days
Alappuzha
Please refer Tender documents.
4 documents required · 4 mandatory
₹7,500
Yes
online
₹1 L
Yes
Online
9 Feb 2021
12 Aug 2020
25 Aug 2020
12 Aug 2020
22 Aug 2020
12 Aug 2020
12 Aug 2020 - 18 Aug 2020
18 Aug 2020
Amount
Road work
2.5.2.A : Dismantling of Structures<br> Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 m as per Technical Specification Clause 202.<br>(II) By Mechanical Means <br> (A) Cement Concrete
2.13.A : Removing all types of Hume pipes and stacking within a lead of 1000 m including Earthwork and Dismantling of Masonry Works as per Technical Specification Clause 202.(A)Upto 600 mm dia Hume pipe
2.5.2.B : Dismantling of Structures<br> Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 m as per Technical Specification Clause 202.<br> (II) By Mechanical Means <br>(B) Reinforced Cement Concrete
2.7.B : Dismantling Stone Masonry as per Technical Specification Clause 202.Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of stone masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 m as per Technical Specification Clause 202.(B)Rubble Stone Masonry in Cement Mortar
2.7.E : Dismantling Stone Masonry as per Technical Specification Clause 202.Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of stone masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 m as per Technical Specification Clause 202.(E)Dismantling Stone Pitching / Dry Stone Spalls
3.4 : Construction of Embankment with Material Obtained from Borrow Pits <br> Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5
3.15.2 : Compacting Original Ground<br> (ii) Compacting original ground supporting subgrade<br> Loosening of the ground upto a level of 300 mm below the subgrade level, watered, graded and compacted in layers to meet requirement of Tables 300.1 and 300.2 for subgrade construction as per Technical Specification Clause 303.5.2.
4.11.2 : Granular sub-base/base/surface course with local materials (Table 400.13) by mix in place method normal. Construction of granular sub-base by providing local material spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at once and compacting with smooth wheel roller to achieve the desired density complete as per Clause 401.4 as per Technical Specification Clause 408. <br>(ii) Using Gravel mix soil.
4.9 : Wet Mix Macadam <br> Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tipper to site, laying in uniform layers in sub-base/base course on a well prepared sub-base and compacting with smooth wheel roller of 80 to 100kN weight to achieve the desired density including lighting, barricading and maintenance of diversion, etc as per Tables 400.11 & 400.12 and Technical Specification Clause 406. <br> By Mechanical Means with 1 km lead
od543992/2019_2020 : Construction of un-reinforced dowel jointed at expansion and construction joint only,plain cement concrete pavement ,thickness as per design,over a prepared sub base,with 43 grade cement or any other type as per clause 1501.2.2 M 40 (grade) PQC,coarse and fine aggregates conforming to IS 383,maximum size of coarse aggregate not exceeding 25 mm,mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design,laid in approved fixed side formwork(steel channel, laying and fixing of 125 micron thick polythene film, wedges,steel plates including levelling the formwork as per drawing),spreading the concrete with showels,rakes,compacted using needle,screed, and plate vibrators and finished in continuous operation including provision of contraction and expansion ,construction joints,applying debonding strips, primer, sealant, dowel bars, near approaches to bridge /culvert and construction joints, admixtures as approved,curing of concrete slabs for 14 days,using curing compound(where specified) and water finishing to lines and grade as per drawing and Technical Specifications clause 1501
3.14 : Construction of Subgrade and Earthen Shoulders<br> Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1.
11.1.1.1 : Excavation for StructuresEarthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.I.Ordinary soil(i)Upto 3 m depth
od544166/2019_2020 : RING BUND Type II Putting up ring bund with earth fille gunny bags of top width<br>1.0m bottom width 2.0m height 2.0 m side and filling in between with earth to<br>form ring bund and maintaining the same leak proof till the completion of the<br>work and clearing the site by dismantling the bund after completion of the<br>work.etc.complete.
od544167/2019_2020 : Bailing out water Using 5HP Pump- Bailing out water with 5HP engine and pump<br>set including conveyance to site and erection,cost of fuel, lubrication oil and other<br>stores, pay of staff etc complete
od544159/2019_2020 : Dry rubble masonry<br>using departmental stone
14.8 : Providing and laying of dry rubble flooring complete as per drawings and technical specifications Clause 1303.3
od544792/2019_2020 : Coconut Pile - Supplying and stacking well matured straight coconut post for<br>driving down throug various strata bellow bed level including cost coveyance<br>labour charges etc complete
od544796/2019_2020 : Coconut Pile - Driving down coconut pile to lines and levels through variuos<br>strata including all hire charges and labour for fixing , staging platform and all<br>other appliances necessary for pile driving down after pointing the bottom end
od544797/2019_2020 : Cutting and removing the excess length of wooden piles to lines and levels and<br>removing the cut end of piles and stacking within 150m
od559432/2019_2020 : Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203<br><br>I.P.C.C grade M 10<br><br>(i)Nominal mix 1:3:6
od701796/2020_2021 : Filling with quarry muck including spreading in layers,levelling and consolidating by ramming etc.complete
12.9 : Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
12.10.1 : Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8I)Granular material
11.4.1.1 : Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203I.P.C.C grade M 10(i)Nominal mix 1:3:6
11.4.4 : Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203IV.R.C.C grade M 20
11.4.5 : Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203V. R.C.C. grade M 25
11.8 : Supplying, fitting and placingTMT bar reinforcement in foundation complete as per drawings and technical specifications Clauses 1000 and 1202
12.5.4 : Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204For height upto 5 mIV.R.C.C. grade M 25
12.5.3 : Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204For height upto 5 m III.R.C.C grade M 20
12.5.1.1 : Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204For height upto 5 mI.P.C.C grade M 15(i)Nominal mix (1:2.5:5)
12.7 : Supplying, fitting and placing TMT bar reinforcement (Fe 415) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
13.1.2 : Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5R.C.C M 25
13.3 : Supplying, fitting and placing TMT bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002,1010 and 1202
13.6 : Construction of R.C.C. railing of M 25 grade in cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical railing post not to exceed 1 in 500, centre-to-centre spacing between vertical posts not to exceed 2000 mm as per drawing and technical specifications Clauses 800, 900 and 1208.3
10.2.A.1.2 : Traffic Signs<br>A. Retro-reflectorised Traffic Signs <br> 1 Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801 <br> 2 600 mm Equilateral Triangle
10.2.A.1.3 : Traffic Signs<br>A. Retro-reflectorised Traffic Signs<br>1 Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801 <br> 3 600 mm Circular
10.4.A.2 : Direction and Place Identification signs with size more than 0.9 sqm size board<br> A. Retro-reflectorised Traffic Signs <br>2 Providing and erecting direction and place identification retro-reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thick with area exceeding 0.9 sqm supported on dia GI Pipe firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701
10.10.2 : Kilometre Stone Kilometre StoneReinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703 2Ordinary Kilometer Stone (Precast)
10.10.3 : Kilometre StoneKilometre StoneReinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703iii)200 m stone (precast)
od701721/2020_2021 : Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads on Bituminous Surface @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes. (Derived from 8.13 MoRTH Roads)
9.7 : Laying Cement Concrete Pipe NP3 (burried conduits) on first class bedding of granular material including fixing collar with cement sand mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonary work in head wall and parapets
SHAJI MATHEW
Bidder Name
SHAJI MATHEW
MANOJ MATHEW
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .