Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.5 LAccepted-AOC | L1 | Accepted-AOC BEING THE LOWEST BIDDER | |
| 2 | L2₹34.4 L+₹1.3 L (3.82%)Rejected-Finance 274 210 DAFNALA ROAD SHAHIBAUG AHMEDABAD GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | L2 | Rejected-Finance OTHER THAN THE LOWEST BIDDER |
Tender Value
Refer Docs
EMD Value
₹83,000
Closing Date
4 Nov 2020, 6:00 pmClosed
GE AF CHILODA
VAYU SHAKTI NAGAR CHILODA
REPAIR/ MAINTENANCE OF WATER SUPPLY INSTALLATIONS, SWIMMING POOL AND ENVIRONMENTAL PARK IRRIGATION SYSTEM AT VAYU SHAKTI NAGAR CHILODA
2020_MES_383862_1
8849/20-21/E8
Open Tender
Miscellaneous Works
Item Rate
273 days
VAYU SHAKTI NAGAR CHILODA
AS PER NOTICE OF TENDER
8 documents required · 8 mandatory
₹500
Yes
GE AF CHILODA
₹83,000
Yes
4 Jan 2021
6 Oct 2020
6 Nov 2020
6 Oct 2020
4 Nov 2020
20 Oct 2020
6 Oct 2020 - 20 Oct 2020
Amount
Testing of Bore well water/ Raw water/STP Water/Clear Water to analyse the following parameters as per IS 10500:2000 through Govt. approved laboratory:- a) Physicochemical parameters of water / eflluent sample b) Bactoriological test of water sample. c) Metals ( Except Hg, As & Se). d) Pesticides.
Supply only Alum Ferric of best quality in packing of 20 Kg bag.
Supply only Alum Non Ferric (White crystal) of best quality in packing of 5 Kg bag.
Supply only Granular chlorine with (90% chlorine/TCCA 90) Altop GP in plastic container of 45 Kg. Make:- ALTOC/ RAMCO/DECLIBAC/TECHNOMAC/MILTON ROY
Supply only Granular Copper sulfate of best quality as directed by Engr-in-charge.
Supply only Granular calcium Hypochlorite having 60 to 70 % available chlorine must contain approximate quantities of disperants/corrosion inhibitors to prevent encrustation/scaling in distribution system( in 45 kg plastic drum) Make:- ALTOC/ RAMCO/DECLIBAC/TECHNOMAC/MILTON ROY
M&L for taking down of old existing unserviceable pool lighting from the swimming pool wall with all electrical connection complete.
S&F under water pool lighting system working on 12V18watt supply complete with bulb holders & individual step down transformer with taking out existing one complete. make- UV rich or equivalent.
S&F straight plain brass ferrules (or connecting screws) screwed both ends and fixed to 200/250mm dia water pipe by proper punching & fixing including earth work all as per site requirement with testing complete.
S&F in repairs lead acid battery for SCADA system of capacity 12 V, 100 AH.
S&F in repairs bronze ball valve of size 15mm dia with handle, screwed both ends for iron pipe and fixed.
All as per item No. 11.00 above but 20 mm dia ball valve complete.
All as per item No. 11.00 above but 25 mm dia ball valve complete.
All as per item No. 11.00 above but 32 mm dia ball valve complete.
All as per item No. 11.00 above but 40 mm dia ball valve complete.
All as per item No. 11.00 above but 50 mm dia ball valve complete.
S&F in repairs sluice valve of size 150 mm dia and class PN 1.6, with iron wheel head, screwed both ends to DI pipe and fixed complete.
All as per item No. 17.00 above but 200 mm dia sluice valve complete.
S&F in repairs air release valve made of CI of size 50 mm dia complete.
Taking up or down GI tubing from trenches/wall/floor/ceiling and connections complete of size 15 mm bore all as directed.
All as per Item no. 20.00 above, but of size 20 mm bore complete.
All as per Item no. 20.00 above, but of size 25 mm bore.
All as per Item no. 20.00 above, but of size 40 mm bore.
All as per Item no. 20.00 above, but of size 50 mm bore.
All as per Item no. 20.00 above, but of size 80 mm bore.
Fixing only 15 mm dia GI tubing of medium grade with all fittings to walls and ceilings or laying in floors or in trecnches with all fittings as per site requirement or as directed by Engr-in-charge. Note- Pipe for fixing shall be issued in schedule 'B' free for fixing and excavation shall be measured and paid under respective item in this schedule.
All as per Item no. 26.00 above, but GI tubing of size 20 mm bore.
All as per Item no. 26.00 above, but GI tubing of size 25 mm bore.
All as per Item no. 26.00 above, but GI tubing of size 40 mm bore.
All as per Item no. 26.00 above, but GI tubing of size 50 mm bore.
All as per Item no. 26.00 above, but GI tubing of size 80 mm bore.
Excavation in trenches not exceeding 1.5m width and not exceeding 1.5 m in depth and getting out in soft/loose soil for taking up/laying cable/pipe etc completed all as apecified and directed.
Returning, filling including spreding, leveling watering & well ramming in layers not exceeding 25cm as directed by Engr-in-charge.
Removal of excavated material at a distance not exc 50 mtr and dipositing where directed at a level not exc. 1.5 mtr above the starting point.
M & L for run lead joint for CI/DI pipe 150/200/250 mm bore of spigot & socket connection complete. Note- Excavation shall be measured and paid under respective item in this schedule.
M&L for rectification of leakage from 200mm HDPE 10 Kg/Sqcm bore pipe line by fixing by heating plate by cutting & removing of pipe & providing new pipe up to 3.0m length, connecting both side with old line by providing necessary fittings with accessories complete inluding all necessary earth work with testing all as per ground requirement or as directed by EIC
All as per Item no. 36.00 above, but for HDPE pipe of 140 mm size complete.
All as per Item no. 36.00 above, but for HDPE pipe of 110 mm size complete.
All as per Item no. 36.00 above, but for HDPE pipe of 75/90 mm size complete.
All as per Item no. 36.00 above, but for HDPE pipe of 63/40 mm size complete.
All as per Item no. 36.00 above, but for HDPE pipe of 140 mm size complete.
S&F in repairs foot valve ball type of size 125 mm dia made cast iron as per IS-4038 PN 0.2 of exixting make-normax
All as per Item no. 42.00 above, but for pipe of 100 mm size complete.
M&L for construction of 3mm thick MS Sheet cover fixed on 40mmx40mmx6mm thick angle iron frame embedded in PCC coping with locking arrangement and mild steel surface with two coats of red oxide primer etc. Complete all as specified and directed.
M&L for rectification of leakage from GI 80 mm size bore pipe line by cutting and removing old lengh of pipe, supply & fix new galvanised iron pipe 80 mm bore medium grade connecting with old line by providing necessary ifitting such as socket & union including screwing old & new pipe including all necessary earth work for connecting complete. Note - Pipe will be issued under schedule B free for fixingi if required more than 1 metre
All as per Item no. 45.00 above, but GI tubing of size 50 mm bore.
All as per Item no. 45.00 above, but GI tubing of size 40 mm bore.
All as per Item no. 45.00 above, but GI tubing of size 25 mm bore.
All as per Item no. 45.00 above, but GI tubing of size 20 mm bore.
All as per Item no. 45.00 above, but GI tubing of size 15 mm bore.
S&F in repairs 15 mm bore unplasticised PVC pipes of pressure rating 10 Kg f/cm2 with all fittings and fixed to walls and ceiling or laid in floors complete. Note:- Excavation/earth work will be measured and paid separately.
All as per item No 51.00 above, but 20 mm bore UPVC tubing complete.
All as per item No 51.00 above, but 25 mm bore UPVC tubing complete.
S&F in repair semi automatic star delta starters in sheet steel enclosure AC-3 duty, 415 V, 25 HP,with ralay range 16-25 A Make:- Make- L&T/ ENGLISH ELECTRIC/ STANDARD/ SIEMENS/ CROMPTON GREAVES
All as per Item no. 54.00 above, But relay range 20-32 and capacity of 30 HP starter complete.
All as per Item no. 54.00 above, But relay range 6-10 A and capacity of 10 HP starter complete.
S&F in repair sheet metal enclosure AC-3 duty,415 V Dol Starter of 10 HP capacity and relay range 14-23 A
S&F in repair sheet metal enclosure AC-3 duty,415 V Dol Starter of 5 HP capacity and relay range 7 -14 A
Supply and fix soft starter of 18 KW capacity
Supply & fix in repair Contactor type- MNX 80 of AC3 80 Amp, 415V, 50 Hz .
Supply & fix in repair Contactor type- MNX 70 of AC3 70 Amp, 415V, 50 Hz.
S&F in repair Contactor of type MNX 50 of AC3 50Amp, 415 Volt, 50 Hz .
Supply & fix in repair NEON LED lamp with cap & lamp fitting complete for R/Y/B phase indicator in existing panel.
Supply & fix in repair slector switches and indicator of Voltage, Ampere meter with complete accessories fitted on existing panel.
M&L for servicing of Centrifugal water pumps (Pressure pumps) of type MH4-40, IP-54 of discharge rate- 5.0 cum/Hr with head 20.5 m operated on 240V, 50 Hz with replacing of box set-04 nos, mechanical seal -01 no, cut off switch 01 no, bearing 02 nos, Air filling in tank complete as per site requirement or as directed by Engr-in-charge.
S&F in repair Air tank of booster (pressure) pump of 24 L for 1 HP pump suitable for lubi Pump model MH4 40 with all accessories complete.
S&F in repairs Danfoss KP-35 pressure control switch for Booster (presuure pump) 1 HP of existing make.
S&F in repairs 1 HP Lubi pressure pump connector of size 1" complete with all accessories.
M&L for taking out & rewinding the existing unserviceable burnt Centrifugal water pumps (Pressure pumps) of type MH4-40, IP-54, single phase, 50 cycles by disconnecting electrically and mechanically and transporting to the locally workshop. Dismantling the motor and removing the old burnt copper winding & demoisturise, cleaning, rewinding the coils with same gauge supper enamelled copper wire, with suitable F class paper insulation, varnishing, and reassembling by replacing bearings reinstalling at the installation and testing, commissioning etc complete.
S&F PVC insulated, PVC sheathed, submersible flat cable ISI marked with multi stranded copper conductor 1100 volt grade of size 16 Sqmm 3 core with PVC conduit of size 25mm dia as per site requirement for connecting pump from panel including heavy duty PVC conduit as per ground requirement complete including taking out of existing cable complete all as per site requirement or as directed by Engr-in-charge.
S&F PVC insulated, PVC sheathed, submersible flat cable ISI marked with multi stranded copper conductor 1100 volt grade of size 10 Sqmm 3 core with PVC conduit of size 20 mm dia as per site requirement for connecting pump from panel including heavy duty PVC conduit as per ground requirement complete including taking out of existing cable complete all as per site requirement or as directed by Engr-in-charge.
S&F PVC insulated, PVC sheathed, submersible flat cable ISI marked with multi stranded copper conductor 1100 volt grade of size 6 Sqmm 3 core with PVC conduit of size 15 mm dia as per site requirement for connecting pump from panel including heavy duty PVC conduit as per ground requirement complete including taking out of existing cable complete all as per site requirement or as directed by Engr-in-charge.
S&F PVC insulated, PVC sheathed, submersible flat cable ISI marked with multi stranded copper conductor 1100 volt grade of size 4 Sqmm 3 core with PVC conduit of size 25mm dia as per site requirement for connecting pump from panel including heavy duty PVC conduit as per ground requirement complete including taking out of existing cable complete all as per site requirement or as directed by Engr-in-charge.
S&F PVC insulated, PVC sheathed, submersible flat cable ISI marked with multi stranded copper conductor 1100 volt grade of size 2.5 Sqmm 3 core with PVC conduit of size 15 mm dia as per site requirement for connecting pump from panel including heavy duty PVC conduit as per ground requirement complete including taking out of existing cable complete all as per site requirement or as directed by Engr-in-charge.
S&F PVC insulated, PVC sheathed, submersible flat cable ISI marked with multi stranded copper conductor 1100 volt grade of size 1.5 Sqmm 3 core with PVC conduit of size 15 mm dia as per site requirement for connecting pump from panel including heavy duty PVC conduit as per ground requirement complete including taking out of existing cable complete all as per site requirement or as directed by Engr-in-charge.
Reapiring / Servicing of complete of all water supply panel by cleaning of movable parts with anti rust spray, replacing of nuts & bolts,washers, with suitable lugs of burnt/rust contacts & fitting of screws & rewiring with suitable guage copper conductor/flexible wires, all as required as per ground condition, with tightening of all loose parts, with testing complete on load all as directed by Engr-in-charge. .
M& L for painting of water supply panel with synthetic enamel paint over and including primer by spray painting inside and outside the panel completely.
Supply & fix in repair, installation, testing and commissioning of gear driven pop up sprinkler (full/part) capable of covering 7-15 m at 1.7-4.5 bars pressure with a discharge rate of 0.09-0.53 litre/second. The overall pop up height shall be 4 inch measured up to the centre of the nozzle. The sprinkler shall have seal-A-metalic device, a pressure- activated wiper seal and a filter screen attached to the drive housing to filter inlet water.the sprinker body shall house a heavy duty stainless steel retract spring for positive retraction. The sprinkler shall have a top adjustable stainless steel screw capable of reducing the radius up to 25%. the body of sprinkler shall be constructed of heavy duty, UV resistant plastic. The sprinkler shall have 12 inter-changeable nozzles: 6 rain curtain nozzles for superior close in watering , 3 low angle nozzle for reduced radius of throw and superior wind resistence, and 3 radius + nozzles for extra distance, including taking down old pop up sprinkler.
Construction of valve pit Complete as per Chief engineer Airforce Ahmedabad Drg No. CEAA/TD/57 sheet No.1.1, Ser No.4 Type 'D' of size 1050 x 750 x 1000mm for 150 to 200 mm dia Sluice / Reflex valve. Complete as speccified & directed by Engr-in-charge.
Supply & fix in repairs rubber lined cast iron diaphragms valves 80mm dia including rubber diaphragms of filter valve with taking out existing valve complete for sand filter at Swimming pool AFS Chiloda of existing make UV rich.
Cleaning of raw water underground / semi under ground RCC reservoir of capacity 3 lakhs gallons at VSN near filtration plant by draining out storage water completely with mud pump or throwing out manually with buckets and cleaning of inner surface of bottom and walls of tank by removing complete accumulated sludge/ mud, dirt etc with wire brush and finally washing with fresh water and disinfecting the reservoir with 2% solution of potassium permaganate including writing date of cleaning with white synthetic enamel paint and removing sludge scale mud etc. to a distance not exceeding 50 metre and deposting complete.
All as per Item no. 81.00 above, but located at MAP pump house for Warrant Officers complete.
All as per Item no. 81.00 above, but cleaning of sump of 2.5 lakhs gallonslocated at MRS pump house complete.
All as per Item no. 81.00 above, but cleaning of sump of capacity 2.00 Lakhs gallons located at SWAC pump house complete.
Cleaning of RCC overhead reservoir of capacity 2.5 lakhs gallons at 30 metre staging, by draining out storage water completely with mud pump or throwing out manually with buckets and cleaning of inner surface of bottom and walls of tank by removing complete accumulated sludge/ mud, dirt etc with wire brush and finally washing with fresh water and disinfecting the reservoir with 2% solution of potassium permaganate including writing date of cleaning with white synthetic enamel paint and removing sludge scale mud etc to a distance not exceeding 50 metre and deposting complete.
All as per Item no. 85.00 above, but cleaning of sump of capacity 1.00 Lakh Litre of HQ fire fighting Pump House complete.
All as per Item no. 85.00 above, but cleaning of sump of capacity 50000 gallons located at type-II and III pump house complete.
All as per Item no. 85.00 above, but cleaning of sump of capacity 50000 gallons located at DSC tower pumphouse complete.
M&L for repair/servicing of 1 HP submersible pump by taking out of pump from pit and repair with proper cleaning of all parts by chemical, drying complete with changing of oil seal, gun metal bushes and rotor machining with replacement of all nut bolts refixing complete with all elecrtrical connection and testing as per site requirement or as directed by Engr-in-charge.
M&L for repair/servicing of 2 HP submersible pump by taking out of pump from pit and repair with proper cleaning of all parts by chemical, drying complete with changing of oil seal, gun metal bushes and rotor machining with replacement of all nut bolts refixing complete with all elecrtrical connection and testing as per site requirement or as directed by Engr-in-charge.
All as per Item no. 90.00 above, but servicing of 3 HP pump complete.
All as per Item no. 90.00 above, but servicing of 5 HP pump complete.
M&L for rewinding of submersible pump motor of capacity 10 HP from pit/sump by disconnecting and mechanically by all electrical and pipe connections complete with replacement of old unserviceable burnt insulated copper wire and rewinding complete with same guage of submerssible insulated wire and testing complete with refitting on site all as per site requirement or as directed by Engr-in-charge. Note- Rates are inclusive of replacing old U/s copper winding and u/s spares.
All as per Item no. 93.00 above, but rewinding of 12.5 HP pump motor complete.
All as per Item no. 93.00 above, but rewinding of 30 HP pump motor complete.
Taking out & rewinding the existing unserviceable burnt motor 5 HP, 3 phase, 50 cycles by disconnecting electrically and mechanically and transporting to the locally workshop. Dismantling the motor and removing the old burnt copper winding & demoisturise, cleaning, rewinding the coils with same gauge supper enamelled copper wire, with suitable F class paper insulation, varnishing, and reassembling by replacing bearings reinstalling at the installation and testing, commissioning etc complete. Note - Before rewinding the existing motor, contractor must show the burnt motor/winding to the Engr-in-charge. Old unserviceable copper retrieved will be property of contractor. Rates are inclusive of Old U/s copper winding and u/s spares.
All as per item No. 96.00 above but of 20 HP motor complete.
All as per item No.96.00 above but of 25 HP motor complete.
All as per item No.96.00 above but of 30 HP motor complete.
All as per item No.96.00 above but of 40 HP motor complete.
Supply and lay M S Pipes heavygrade with all fittings flange type laid infloors or fixed to walls and ceilings etc of sizes 125 mm as directed by EIC
Supply and lay M S Pipes heavygrade with all fittings flange type laid infloors or fixed to walls and ceilings etc of sizes 150 mm as directed by EIC
Servicing of Pressure Transmitter- 12 No., Electical Motorized actuator mounted on Butterfly valves of size 80 mm to 300 mm - 56 No., electromegnetic flow meter of 150 mm to 300 mm - 5 No., megnetic float switch - 97 No., Solenoid valve of 10 mm to 50 mm - 135 No, three phase Actuator - 04No. , residul chlorine analysyer with automatic chemical dosear - 01 No., Turbidity analysye - 01 No., Master control station room SCADA Computer System and accessarios , Printer , Modem ,UPS - 01 No., Master control station room Mimic Panel- 01 No, 650 VA to 3 KVA Inveter with battery- 05 No., SCADA software for Automation system and generate backup of SCADA Database - 01 No., Electrical transducer - 13 No., Gateway Unit with Inbuilt RF and GSM /GPRS Modem - 01 No.,GSM /GPRS communication Modem - 06 No., RF communication Modem - 09 No, iRTU i9000 Panel includes motherboard , AI Card , AO Card , DI Card , Do Card , CPU Card, Relays , Switches , Indicator bulbs , hooter , MCB , Fuse TB - 05 No., iRTU 6000 Panel includes motherboard , AI Card , AO Card , DI Card , DO Card , CPU Card, Relays , Switches , Indicator bulbs , hooter , MCB , Fuse TB - 09 No., dosing pump - 01 No. i/e Cleaning checking for wear and tear, checking electrical termination, testing as directed by Engr-in-Charge. (once every week) and Breakdown maintenace as and when required excluding of spares. Note :(i) New parts required to be replaced shall be measured and paid under relevant items of the schedule.
M & LIVE IP for (MCS) for the period of 11 week for whole water supply SCADA wireless commuciation system.
Charges for GSM/GPRS SIM card 6 Nos. charges including rental/SMS charges for the period of 11 month for the whole water SCADA wireless communication system.
Supply and fixing of Internet Security anti virus software with one user license for one year. Make : MacAfee / NPAV / QUICK HEAL
Supply and fix of UPS of suitable capacity 600 VA, 230 V AC with 20 min back up FOR MASTER CONTROL STATION Make- APC
Supply and fix of Butterfly Valves of 150 mm line size Make: Valve :Belimo/rotor/auma
Supply and fix of Butterfly Valves of 200 mm line size Make: Valve :Belimo/rotor/auma
Supply and fix of Butterfly Valves of 250 mm line size Make: Valve :Belimo/rotor/auma
Supply and fix Single Phase Motorized Actuators IP67 suitable for 200 mm butterfly Valve Model (SY3-230-3T or equivalent) Make: Valve :Belimo/rotor/auma
Supply and fix Single Phase Motorized Actuators IP67 suitable for 250 mm butterfly Valve Model (SY4-230-3-t or equivalent) Make: Valve :Belimo/rotor/auma
Supply and fix GSM/GPRS communication Modem along with suitable external antenna of suitable gain,patch chord and mounting accessories with following specification. Make: cimcon /siemens/motorolla
Supply and fix Wireless Gateway Unit with inbuilt RF and GSM/GPRS Modem 1. CPU :- 32 bits ARM9 running at 250 Mhz. 2. Data Storage : 2 GB micro SD card,32KB EEPROM. 3. RTC : Real time clock for time based operations. 4. Multiple Communication Ports for Field and MCS communications :Two-way simultaneous communication with multiple Level controller using RF and MCS using GSM/GPRS mode. 5. Communication Protocol Support : ModbusTCP/IP, ARP, RARP, ICMP, IP, UDP, DHCP, DNS, TFTP 6. Enclosure : Polycarbonate. 7. Operating temperature:-20oC to 70oC/- 4oF to +158oF 8. Storage temperature -40oC to +85oC/- 40oF to +185oF 9. Humidity :5% to 95% R.H. non-condensing 10. Protection :IP 65 11. Power Supply: Universal AC input 85-264 VAC, 50/60HZ 12. Wireless Communication With Level Controller : . 2.4GHz,IEEE 802.15.4 Open field Range Up to 4000 ft./1km Line of Sight Low power Capable of Mesh Networking Make :cimcon /siemens/seinider
Supply and fix Three Phase Actuator for Inlet Valve (Gate Type Valve,Width 1 Ft, Height 10 Inch) for filteration Plant Make: MARSH/Belimo/auma/rotor
Supply and fix ARM7 based CPU Card of Model iRTU 9000 Make : cimcon or equivalent or equivalent
Supply and fix ARM7 based CPU Card of Model iRTU 6000 Make : cimcon or equivalent or equivalent
Supply and fix AI Card of Model iRTU 9000 Make : cimcon or equivalent
Supply and fix DI Card of Model iRTU 6000 Make : cimcon or equivalent
Supply and fix DO Card of Model iRTU 9000 Make : cimcon or equivalent
Visit and inspection charges monthly for environment park area irrigaton system(make-rainbird) by authorized technician of Rain Bird company.Technician will have the resposibility to check the system completely and preventive maintence of irrigation system Note-Changed Spare parts will be paid separately
Install & fix in repairs of genuine software of rainbird company to operate the complete irriagation system with the help of computer system.Software should be with original patch or key
Supply & fix in repairs of Front panel box for controller and PWB assembly of Make- Rain Bird from existing place & installation complete all as per sire requirement or as directed by EIC with testing commissioning complete.
Supply & fix in repairs solenoid valve coil suitable for valve upto 4" complete all as per sire requirement or as directed by EIC with testing commissioning complete.
Supply & fix in repairs POP UP Sprinklers 751 series(half circle) complete all as per sire requirement or as directed by EIC with testing commissioning complete.
Supply & fix in repairs POP UP Sprinklers 700 series(full circle) complete all as per sire requirement or as directed by EIC with testing commissioning complete.
Supply & fix in repairs DBY connector 3M/Paige/Rainbird system all as per site requirement or as directed by EIC
Supply & fix in repairs Round valve box 10" of make- Rain bird all as per site requirement or as directed by EIC
Supply & fix in repairs ractangular valve box 17 x 12" RainBird all as per site requirement or as directed by EIC
Material & labour for fixing & jointing of automation cable 14/1 paige
S&F in repairs Hydrant 1" for sprinkler all as per site requirement or as directed by EIC
S&F in repairs Hydrant opener of size 1" for sprinkler all as per site requirement or as directed by EIC
S&F in repairs Swiel elbow of size 1" for sprinkler all as per site requirement or as directed by EIC
M&L for regular maintenance of pump house of irrigation system (make-grunfoss,capacity-15 kw) for 9 months, including regular servicing, inspections, preventive maintenance, bearing, bush, impeller & casing should also be checked and cleaned & do turning/tapering all as per requirement or as directed by EIC by trained technicians of grunfoss company or dealer and repair of the installation Note- i) five routine maintanance services for oiling & greasing included in the quoted rates. ii) Cost of repair / replacement of any of the worn out part will be paid separately
S&F in repairs cooling fan installed at Grounf foss panel with testing complete.
S&F in repairs connectors din type mounting on din rail for connecting cable upto 10 sqmm size single core cable all as directed by EIC.
S&F in repairs FN (TP) S-D-F suitable for FN 200 TP DIN fuse-link, 415 V, 50Hz cat no. ST27895 of Make- L&T
S&F in repairs Grundfos kit, chamber + bearing - SIC/SIC for hydropneumatic pump of model CRCM 45-4-2 15 (KW)
S&F in repairs Grundfos bulk - Bush D22 of Cat No. Buss D22 CR 45 (370024)
S&F in repairs Grundfos kit, Shaft seal cat no. CR/N 32-150 HQQE
S&F in repairs disc type Non return valve of size 80mm dia
S&F in repairs O-ring for pump suction side & dilevery side (02 nos)
S&F in repairs Motor starter protection relay cat GV2 ME32 of range 24-32 A, 50 Hz of make- Schneider
S&F in repairs Motor protection relay front contact NO + NC for MPCB GV2, 50 Hz of make- Schneider
S&F in repairs Contactor of cat no. LC1D18 of 32 A , 50 Hz
S&F in repairs Contactor of cat no. LC1D25 of 40 A , 50 Hz
S&F in repairs Contactor of cat no. LC1D40 of 60 A , 50 Hz
S&F in repairs ON Time delay switch 0.1-30 Sec of cat no. LAD T2 , 50 Hz
S&F of following golf rotor & equipment as following
1' Swing Joint of 12" Lay Length
P.E Saddle Tee 50mm x 1"
P.E Saddle Tee 63mm x 1"
1"brass Quick coupling valve
1' Brass Quick coupling key
Supply and fixing of following mainline valves/leteral valves & accessories.
Butterfly valve 5"
Butterfly valve 4"
Lateral valve PVC 63mm
PP saddle tee 140mm x 2"
p.p Saddle Tee 110mm x 2"
12" Rectangular Valve Box
Air Release Valve 2"
6" round Valve Box
S &F of following automation and electricals systems & accessories
2" solencid Valve complete with accessories.
M&L for servicing of pressure filter 300 series 3" dia disc type filter by removing of filter from the installation complete & taking out all the DISC & candle from the filter & washing/cleaning of complete filter with wire brush & removing all sludge/un wanted material by fresh water & fiiting complete filter & testing complete for every months all as per site requirement or as directed by EIC.
Taking out & rewinding the existing unserviceable burnt motor 50 HP, 3phase, 50 cycles by disconnecting electrically and mechanically and transporting to the locally workshop. Dismantling the motor and removing the old burnt copper winding & demoisturise, cleaning, rewinding the coils with same gauge supper enamelled copper wire, with suitable F class paper insulation, varnishing, and reassembling by replacing bearings reinstalling at the installation and testing, commissioning etc complete. Note - Before rewinding the existing motor, contractor must show the burnt motor/winding to the EIC. Old unserviceable copper retrieved will be property of contractor. Rates are inclusive of Old U/s copper winding and u/s spares.
Supply and fix VFD(Variable flow device) suitable 15 KW pump suitable for grunfoss panel of irrigation system cat part no. VFD FC101 15.0 KW 131L9870IP20 A2 N
ALBA AC AND REF SERVICES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .