Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.2 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹2.4 L+₹18,629.74 (8.35%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹2.9 L+₹67,456.30 (30.2%)Rejected-AOC CHAKKALAKKAL H KOTTAT P O | L3 | Rejected-AOC L3 | |
| 4 | L4₹3.1 L+₹81,988.02 (36.7%)Rejected-AOC THRISSUR KERALA KL | PALAKKAD | KERALA | 678001 | L4 | Rejected-AOC L4 |
Tender Value
₹2.9 L
EMD Value
₹7,266
Closing Date
16 Jul 2026, 4:00 pmClosed
Assistant Executive Engineer
o/o The Assistant Executive Engineer PWD Electrical Sub Division Chembukavu,Thrissur-20
DEPOSIT-PHC Porkulam LAB Thrissur District-UPs-General Electrical Work Electrification
2026_PWD_859632_1
ESDT(ET)34/AEE/26-27
Open Tender
Electrical Works
Percentage
90 days
Thrissur
Please refer Tender documents.
10 documents required · 10 mandatory
₹645
₹7,266
24 Sept 2026
8 Jul 2026
18 Jul 2026
8 Jul 2026
16 Jul 2026
8 Jul 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1air conditioner and ups installation | |||||
| 1.001 | OD258009/2024-2025:Supply, installation, and commissioning of 3kva UPS Single phase in and out. with indoor (IP20) with 1 hours backup battery @ 3kva with min VAH of 4752 (Tubular battery of reputed approved make exide/quanta including rack and interconnecting cables), Input pf >0.99, Inernal Isolation transformers at Input, double conversion technology with input voltage range 160-300 @ full load, 50Hz Single Phase, output 230V, 50Hz Single phase, It shall be 100% generator compatible, with Efficiency > 87% and output power factor unity ( 3kVA= 3kW), Eco mode Efficiency 98% and including all accessories etc as required. The acoustic noise at 1m of the system should be <50dB.The system shall comply to IEC /EN 62040-1, EN/IEC 62040-2, EN/IEC 62040-3, CE, BIS, ROHS, Certificates, and relevant IS standards. The system shall be true online double - conversion DSP based UPS system and also UPS shall be with automatic bypass builtin. The system shall have IGBT rectifier and inverter with 12v 66ah exide 6EL Tubular batteries 6 nos. warranty 3 years for UPS and batteries. Comparable brands Numeric-legrandAPC/GE or equivalent | - | each | 1,80,986.1 | - |
| 1.002 | 1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm) | - | each | 377.01 | - |
| 1.003 | 1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch | - | each | 179.42 | - |
| 1.004 | 1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet | - | each | 226.71 | - |
| 1.005 | 1.27.4:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm) | - | each | 462.42 | - |
| 1.006 | 1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch | - | each | 118.41 | - |
| 1.007 | 1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet | - | each | 140.46 | - |
| 1.008 | 1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm | - | metre | 109.53 | - |
| 1.009 | 1.17.6:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm | - | metre | 207.98 | - |
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.03 MB
Tendernotice_2.pdf
PDF • 0.05 MB
Tendernotice_3.pdf
PDF • 0.20 MB
Tendernotice_4.pdf
PDF • 0.20 MB
Tendernotice_5.pdf
PDF • 0.03 MB
Tendernotice_6.pdf
PDF • 0.27 MB
BOQ_1453564.xls
BOQ • 0.35 MB
NIT.pdf
Tender Documents • 0.03 MB
SBD.pdf
Tender Documents • 1.63 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .