Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.1 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹46.3 L+₹1.9 L (4.25%)Rejected-AOC SECUNDERABAD | WARANGAL | TELANGANA | 506350 | L2 | Rejected-AOC Being not L1 | |
| 3 | L3₹46.4 L+₹2.0 L (4.51%)Rejected-AOC | L3 | Rejected-AOC Being not L1 | |
| 4 | L4₹49.9 L+₹5.5 L (12.3%)Rejected-AOC | L4 | Rejected-AOC Being not L1 |
Tender Value
₹49.2 L
EMD Value
₹98,400
Closing Date
30 Sept 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri M Saravanan, IDSE, GE
Garrison Engineer North 35 Allenby Lines Secunderabad 500087
SPL REPAIRS OF SEWAGE OF BLDG NO P 142 ADM BLOCK P 149 P 150 OR OTM ACCN AND T 34 TO T 36 JCO OR MD ACCN AT PLASSEY LINES PROVN OF GUARD ROOM FOR ONE NCO AND FOUR ORs WITH TOILET FACILITY AT MAIN ENTRANCE GATE OF FASF KOMPALLY AND PROVN OF TOILET
2023_MES_615487_1
8718
Open Tender
Civil Works
Item Rate
180 days
GARRISON ENGINEER NORTH SECUNDERABAD
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GARRISON ENGINEER (NORTH) SECUNDERABAD
₹98,400
Yes
13 Jan 2024
24 Aug 2023
2 Oct 2023
24 Aug 2023
30 Sept 2023
11 Sept 2023
Amount
Demolition of Brickwork or stone/boulder masonry built in cement mortar, including all quoins, arches, pillar etc., complete all as specified and as directed.
M&L for walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar 1:6 complete all as specified and as directed.
M&L for walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar 1:6 but except stone complete all as specified and as directed.
M&L for brick work with flyash Bricks straight or curved on plan exc 6m mean radius built in CM 1:4 complete all as specified and directed.
M&L for PCC 1:3:6 Type C-1 using 20 mm graded stone aggregate as in in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded for chamfered angles and throating complete all as specified and as directed.
M&L for 15mm thick cement plaster in cement mortar 1:4 on fair faces of brick/concrete surface finished even and smooth without using extra cement with Water Proofing Compound (WPC) complete all as specified and as directed.
Supply only integral water proofing compound complete all as specified and as directed.
M&L for PCC 1:4:8 type D2 with using 40mm graded stone aggregate as in surface channels and drains complete all as specified and as directed.
Demolition of reinforced cement concrete of any description and in any position complete all as specified and as directed.
M&L for precast reinforced cement concrete cover slab for manhole with concrete 1:2:4 type B1 with using 20mm graded stone aggregate, set in cement mortar 1:6 including form work required complete all as specified and as directed. Note: Re-inforcement shall be measured and paid separately.
M&L for Mild steel reinforcement TMT bars 10 mm dia and over cut to length bent to shape required including cranking hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
Excavation in trenches n exc 1.50 m wide & n exc 1.50 in depth, for foundation etc or for shafts, wells, cess pits, manholes, pier holes etc., n exc 10 Sqm on plan and n exc 1.50 m in depth and getting out in hard/ dense soil complete all as specified and as directed.
M&L for Reinforced concrete pipes class NP 2 of 300 mm dia laid and jointed complete with collars complete all as specified and as directed.
M&L for Reinforced concrete pipes class NP 2 of 200 mm dia laid and jointed complete with collars complete all as specified and as directed.
M&L for Reinforced concrete pipes class NP 2 of 150 mm dia laid and jointed complete with collars complete all as specified and as directed.
M&L for plain cement concrete type D-2, 1:4:8 using 40mm graded crushed stone aggregate as in bed to drain pipes including packing under & haunching against the sides of pipes (300mm bore pipe) after the pipe are laid and tested complete all as specified and directed.
All as per item No 16 above, but for 200 mm bore pipes complete all as specified and as directed.
All as per item No 16 above, but for 150 mm bore pipes complete all as specified and as directed.
Material and labour for plain cement concrete 1:2:4, type B1 (using 20mm graded stone aggregate) in coping, benching of manholes, drains, compound walls, bed blocks etc., with necessary formwork including demolition of the existing plain cement concrete complete all as specified and as directed.
Demolition and breaking up drain pipes salt glazed ware, AC, PVC or reinforced concrete) 300 mm dia set in cement mortar height upto 12 mtr complete all as specified and directed.
All as per item No 20 above but for 200 mm bore pipes complete all as specified and as directed.
All as per item No 20 above but for 150 mm bore pipes complete all as specified and as directed.
Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed.
Removal of surplus soil to a distance n.exc. 50 m and n.exc. 1.5 m above the starting point complete all as specified and as directed.
M&L for 110 mm dia UPVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed.
M&L for 75 mm dia UPVC (SWR) pipes single socketed, in any length, with rubber ring joints, fixed to walls complete all as specified and as directed.
M&L for 110 mm bore UPVC/PVC (SWR) bends any radius complete all as specified and as directed.
M&L for 75 mm bore UPVC/PVC (SWR) bends any radius complete all as specified and as directed.
S&F 75 mm UPVC/PVC (SWR) branch piece, single (single Y) equal or un equal complete all as specified and as directed.
S&F 110 mm UPVC/PVC (SWR) branch piece, single (single Y) equal or un equal complete all as specified and as directed.
M&L for bands, straps, supports or stays for rain water, ventilating pipes, including bolts, if required complete all as specified and directed.
Excavating over areas, n exc 3 m deep and getting out hard/ dense soil complete all as specified and as directed.
Dismantling drain pipes (salt glazed ware, AC or reinforced concrete) 100 mm dia set in cement mortar complete all as specified and as directed.
Surface dressing n exc 15 cm deep in hard/dense soil complete all as specified and as directed.
M&L for Cement concrete in foundations, filling and mass concrete Type E2 1:5:10 using 40mm graded stone aggregate complete all as specified and as directed.
M&L for RCC M-25 Design mix concrete using 20mm graded stone aggregate as in Foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, basement slabs, under-reamed piles and mass concrete complete all as specified and as directed.
M&L for RCC M-25 Design mix concrete using 20mm graded stone aggregate as in Columns, pillars, piers, posts and struts complete all as specified and as directed.
M&L for RCC M-25 Design mix concrete using 20mm graded stone aggregate as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed.
M&L for RCC M-25 Design mix concrete using 20mm graded stone aggregate as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed.
Use&waste Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter rough finished surfaces of flat surfaces complete all as specified and as directed.
Use&waste Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. rough finished surfaces of flat surfaces complete all as specified and as directed.
Use&waste Formwork to sides of pillars, posts, struts, piers, columns and stanchions rough finished surfaces of square, rectangular or polygonal surface complete all as specified and as directed.
Use&waste Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) rough finished surfaces of flat surfaces complete all as specified and as directed.
M&L for RCC M25 Design mix concrete as in Chajjas using 20mm graded stone aggregate complete all as specified and as directed.
Use&Waste Formwork to chullah hoods, chajjas, troughs and similar items including edges rough finished surfaces of flat surfaces complete all as specified and as directed.
Use&Waste Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide rough finished surfaces of concrete complete all as specified and as directed.
S&F Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
S&F Mild steel bars 5mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clip complete all as specified and as directed.
M&L for Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in Modular bricks in cement mortar (1:6) complete all as specified and as directed.
M&L for Brickwork with flyash bricks, straight or curved on plan to any radius in half brick thick walls, built in Modular bricks in cement mortar (1:4) complete all as specified and as directed.
M & L for PCC Cement concrete type D- 2, 1:4:8 (40mm graded stone aggregate) as in sub-base of 75mm thick complete all as specified and as directed.
M&L for Non - skid Coloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match cement plaster Screed bed or bedding layer of mortar 15 mm thick for laying floor finishes complete all as specified and as directed.
M&L for Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match, add to above for work on vertical surfaces such as skirtings, dados and risers to steps etc Rendering 10mm thick on fair faces of brick work or concrete surfaces complete all as specified and as directed.
M&L for Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match Screed bed or bedding layer of mortar 15 mm thick for laying floor finishes (1:6) complete all as specified and as directed.
M&L for Glazed ceramic tiles in vertical surface 300x 200x 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match Rendering 10mm thick on fair faces of brick work or concrete surfaces complete all as specified and as directed.
M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete Screed bed or bedding layer of mortar 15 mm thick for laying floor finishes (1:6) complete all as specified and as directed.
S&F Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete all as specified and as directed.
S&F 30 mm Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and as directed.
S&F Glazed and skeleton shutters, open rebated and Prepared to receive glass, gauze, etc., (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc., sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a), supplied and fitted to chowkats but divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers 1st class hard wood 35 Thickness of shutter in mm complete all as specified and as directed.
S & F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, supplying & fixing in opening as per specification & drawing complete all as specified and as directed.
S & F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Paneling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing complete all as specified and as directed.
Supplied & fixed Steel door including projecting type hinges, steel handle, complete, with glazing bars, dovetailed or welded complete all as specified and as directed.
S&F Steel ventilator with top hung shutter including hinges, steel peg stay complete all as specified and as directed.
S & F 100mm Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-22 complete all as specified and as directed.
S & F Size of handle in 150 mm Extruded aluminium alloy handles, fabricated type, anodised complete all as specified and as directed.
S & F Length of bolt in 200 mm Aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and as directed.
S & F Length of bolt in 300 mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and as directed.
S & F Mild steel 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and as directed.
S&F Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor Overall 150mm length of cover plate complete all as specified and as directed.
S & F Aluminium HAT PEGS AND HOOKS of 50 to 60mm long complete all as specified and as directed.
S & F Aluminium chromium anodised, TOWEL RAILS, Tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and as directed.
S&F Wash down water closet (Pedestal pattern), complete WATER CLOSETS Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe complete all as specified and as directed.
S&F Wash basins, Vitreous China (flat back or angle back type) any size, including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe Vitreous Cliina wash basin, wliile, flat back, size 580x450irun (for Hospital use) excluding taps, waste, chain and plug and porcelain stopper but including brackets complete all as specified and as directed.
S&F Vitreous China Urinal, full stall type, white (excluding flushing cistern, flush pipe and waste pipe) Vitreous China urinals, bowl type (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified and as directed.
S & F Vitreous china urinal partition white of size 310mm x 700mm complete all as specified and as directed.
Supply only PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets 10 liters complete all as specified and as directed.
M & L for 75 mm UPVC/PVC (SWR) floor trap, plain with grating including jointing with solvent cement FLOOR AND NAHANI TRAPS complete all as specified and as directed.
S & F 110mm UPVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors PVC SOIL, WASTE AND RAINWATER (SWR) DRAINAGE PIPES complete all as specified and as directed.
S & F 75 mm UPVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors PVC SOIL, WASTE AND RAINWATER (SWR) DRAINAGE PIPES complete all as specified and as directed.
S & F 110mm UPVC/PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and as directed.
S & F 110mm UPVC/PVC (SWR) bends of any radius complete all as specified and as directed.
S & F 75 mm UPVC/PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and as directed.
S & F 75mm UPVC/PVC (SWR) bends of any radius complete all as specified and as directed.
M & L for PCC (1:4:8) Type D-2 Cement concrete in foundations, filling and mass concrete complete all as specified and as directed.
M & L for Cement concrete type B- 2, 1:2:4 (40mm graded stone aggregate complete all as specified and as directed.
Material and labour for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:3 finished even and smooth without using extra cement complete all as specified and as directed
M & L for APP based polymeric membrane minimum weighing 3kg/Sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/Sqm) land on primed surface by forced application complete all as specified and as directed
Material and labour for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 complete all as specified and as directed.
M & L for rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 finished even and smooth (without using extra cement) complete all as specified and as directed.
M & L for rendering 10mm thick on other faces of brick work or concrete surfaces in cement mortar 1:6 complete all as specified and as directed.
M&L for Plaster of Paris putty of 1 mm thickness over plastered surface to prepare the surface even and smooth distempering walls with distemper dry, white or tinted Priming plastered and other surfaces with alkali resistant priming paint complete all as specified and as directed.
M & L for 3 coats of White wash on ceiling surfaces including preparation of new plastered surfaces complete all as specified and as directed.
M & L for 2 coats of Cement Based Paint including Priming plastered and other surfaces with alkali resistant priming paint complete all as specified and as directed.
M & L for Anti-termite treatment (ATT) treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and as directed.
M & L for Anti-termite treatment (ATT) Treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface complete all as specified and as directed. Note: Area of the sub structure in contact with backfill to be measured.
M & L for treating the soil alongwith external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified and as directed.
M & L for Anti-termite treatment (ATT) under plinth protection treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and as directed.
Spreading and leveling in layers n exc. 25 cm thick, well ramming including watering as required complete all as specified and as directed.
M & L for Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, leveled and rammed including watering complete all as specified and as directed.
M & L for two coats of synthetic enamel paint on wooden Surfaces of any description, not otherwise described, over 10cm width or girth including one coat of pink primer complete including preparation etc., complete all as specified and as directed.
M & L for two coats of synthetic enamel paint over a coat of red-oxide primer on steel Surfaces of any description, over 10cm in width or girth, not otherwise described including preparation etc., complete all as specified and as directed.
S & F 1000 litres capacity Rotational moulded polyethylene triple layered water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and as directed.
S &F 20mm dia Ball brass valves, high pressure, with polythene float and fly nut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed.
S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290 Gde-E-165 complete all as specified and as directed.
S&F 4mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 Sqm in each pane complete all as specified and as directed.
S&F Plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and as directed.
Supply and lay of CPVC pipes Schedule SDR 11 and plain CPVC SDR 11 fittings for Hot/cold water for sizes (outer dia) mentioned below including all fittings and fixed with solvents as per manufactures recommendations all specified in SSR Part-I including concealing the pipes in the wall/ceiling or laying in floors and testing complete of following sizes :- (a) 16 mm outer diameter.
All as per item No. 106 above, but 20mm outer diameter
All as per item No. 106 above, but 25mm outer diameter
Supply and fix 15 mm long body bib taps cast copper alloy fancy type with chromium finish with crutch or butter fly handle, screwed down, screwed for iron pipe or brass ferrule complete all as specified and as directed.
Supply and fix PVC connection 15mm bore 450mm length fixed with PTMT nuts, fixed to stop valve, pillar cock, mixture valve etc, with a pair of CP nuts and wathers complete all as specified and as directed.
Supply and fix 15mm stop valves, cast copper alloy, chromium plated, fancy type, long shank and cup (concealed type) screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for uniform and fixed complete all as specified and as directed.
Supply and fix gun metal globe or gate valves 20mm dia bore, conforming to IS 778-1984 with brass spindle and iron wheel head at the top screwed both ends for GI pipe including all fitting/fixtures like nipple, union etc, complete all as specified and as directed.
Supply and fix gun metal globe or gate valves 25mm bore, conforming to IS 778-1984 with brass spindle and iron wheel head at the top screwed both ends for GI pipe including all fitting/fixtures like nipple, union etc, complete all as specified and as directed.
Supply and fix 15mm dia Angular stop cock, brass, chromium plated with wall flange, fancy type, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed completed all as specified and as directed.
Supply and fix swivel shower of PTMT, any colour for fixing with 15mm pipe of weight not less than 40gms and shower arm 15mm size, 195mm long with bend of 45 degree with flange of PTMT, any colour not less than 40 gms complete all as specified and as directed.
Supply, lay and fixing steel water tubes, medium grade, ISI marked, galvanised with all fitting laid in trenches complete all as specified and as directed for the following bore of pipes:- (a) 20mm dia bore
All as per item No. 116 above, but 25mm dia bore complete all as specified and as directed.
All as per item No. 116 above, but 40mm dia bore complete all as specified and as directed.
Supply and fix gun metal gate valve, ISI marked connected with iron wheel head, screwed at both ends for iron pipes and fixed including taking down of unserviceable gate valve complete all as specified and as directed for the following sizes:- (a) 40mm dia
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in hard/dense soil complete all as specified and as directed.
Excavating over areas not exceeding 1.50m deep and getting out in hard/dense soil complete all as specified and as directed.
Approved moorum/Red bajri, 100mm thick (spread thickness) for road side berms, spread, rolled and consolidated to required gradient and camber complete all as specified and directed.
M&L for Pre-cast PCC block edging (as in kerbs) with PCC 1:3:6 type C-1 (using 20mm graded stone aggregates) blocks of size 450mm long, 200mm deep and 100mm wide for edging to roads including necessary use and waste of form work and set in cement mortar 1:6 complete all as specified and directed.
Excavation in trenches not exceeding 1.50m wide and not exceeding 1.50m deep for foundation for laying of pipes /cables/poles etc not exceeding 10 Sqm on plan and getting out in hard/dense soil complete all as specified and as directed.
M&L for PCC 1:4:8 type D-2 (40mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and as directed.
M&L for two coats of plastic emulsion paint on concrete surfaces including preparation of new surfaces and one coat of primer on newly plastered surface complete all as specified and as directed.
M&L for painting lines, dashes etc., on roads pavements exc 10cm wide with 2 to 3 mm thermo plastic road making paint white or golden yellow by automatic road marking paint spray machine complete all as specified and directed
M&L for Cat eyes along the road complete all as specified and as directed.
Soling (or sub base) 150 mm thick with broken boulders or quarried stone, inter stices filled, surface formed and rolled and consolidated to required gradient and camber complete all as specified and as directed.
M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade, with grey cement and pigment complete all as specified and as directed.
M&L for Chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors complete all as specified and as directed.
M&L for Chequered cement concrete tiles 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement and no pigments and including screed bed or bedding layer of mortar 20mm thick for laying floor finishes in CM 1:4 complete all as specified and as directed.
M&L for PCC 75mm thick type D2 1:4:8 (40mm graded stone aggregate) as in sub-base complete all as specified and as directed.
M&L for cement concrete 75mm thick type D2 1:4:8 (20mm graded stone aggregate) as in sub-base complete all as specified and as directed.
M&L for 50mm thick Sand bed filling under interlock tiling including watering and consolidation complete all as specified and as directed.
Supply only 150mm bore pipes, class NP2 with one collar per length of pipe complete all as specified and as directed.
DCWPE (SN8) 180 (OD)/ 163 (ID) mm diameter pipes laid on 150 mm thick bed with excavation in any type of soil, including manholes/ drop manhole of standard size made of brick masonry/ RCC/ Precast RCC with SFRC ventilating cover and frame. Includes all items and activities to execute and make sewer line functional complete all as specified and as directed. (a) 0.70 - 1.65 m
DCWPE (SN8) 200 (OD)/ 175 (ID) mm diameter pipes laid on 150 mm thick bed with excavation in any type of soil, including manholes/ drop manhole of standard size made of brick masonry/ RCC/ Precast RCC with SFRC ventilating cover and frame. Includes all items and activities to execute and make sewer line functional complete all as specified and as directed. (a) 1.65 - 2.30 m
DCWPE (SN8) 300 (OD)/ 260 (ID) mm diameter pipes laid on 150 mm thick bed with excavation in any type of soil, including manholes/ drop manhole of standard size made of brick masonry/ RCC/ Precast RCC with SFRC ventilating cover and frame. Includes all items and activities to execute and make sewer line functional complete all as specified and as directed. (a) 1.65 - 2.30 m
On site Hume pipe septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, vent shaft, connection etc., complete for 5 Users all as specified and as directed.
Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M-25 concrete including intercepting chamber and screen chamber made of brick masonry in CM, RCC cover slab in M-25 /SFRC cover, interconnecting pipes of RCC/ DWC complete filled with brick bats of size 1.2 M dia x 1.5 M effective depth complete all as specified and as directed.
M & L for Point wiring with 1.5 Sqmm copper conductor single core PVC insulated unsheathed 1100 Volts multistranded drawn through and including rigid PVC conduit concealed and conduit accessories of suitable dia medium grade and pressed steel terminal boxes of 2 mm thick MS of suitable size duly painted with red oxide metal primer including fixing/grouting sunken/ surface as per site requirement covered with suitable modular mounting plates for fixing switches / sockets/ regulators etc including running up of 1.5 Sqmm copper conductor PVC insulated cable as earth continuity conductor along with wiring and connecting to the common earth dolly complete all as specified as directed for: (a) One light / bell point controlled by one, one way switch 5 amps, single pole.
All as per item No. 143 above, but one Ceiling Fan / exhaust fan point controlled by one, one way switch and regulator complete all as specified and as directed.
All as per item No. 143 above, but one 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board complete all as specified and as directed.
Description as per item No. 145 here in before, but using 2.5 Sqmm single core copper conductor cable of multistranded PVC insulated unsheathed 1100 Volts grade for 3 Pin 15 Amps switch socket combination point on independent board including running of 1.5 Sqmm copper conductor PVC insulated cable as earth continuity conductor complete all as specified and as directed.
Supply and fix modular switch 1 way 6 A, 1 module capacity 230 volts complete all as specified and as directed.
Supply and fix modular socket 5 pin 6 amps 2 module, 230 Volts complete all as specified and directed.
Supply and fix electronic ceiling fan regulator modular 5 stepped type heavy duty suitable to work on 230 volts complete all as specified and as directed.
Supply and fix Switch modular 1 Way 16 amps, 230 Volts on existing board including taking down complete all as specified and as directed.
Supply and fix in replacement modular socket 6 pin 6/16 amps 2 module, 230 Volts complete all as specified and as directed.
Supply & Fix wall mounted light fitting suitable for 10-20 watt LED Bulb including taking down existing unserviceable light fitting complete with all accessories complete all as specified and as directed. Make:- Havells Cat No LHDL06160099, C&S & Wipro.
S & F ceiling rose three terminal surface bakelite type AC 50 Hz 230 volts of size 65 x 50 mm complete all as specified and as directed.
S & F wall mounted LED batten with extruded aluminium heat sink provided for efficient heat dissipation and integrated electronic driver 1X 20w ,230 volts, bipin holders, diffused type connector block internally prewired box type etc complete with 2 Nos PVC round blocks with necessary fixing arrangements and connecting to the point wiring with necessary flexible copper conductor of multistranded three core 1.5 sqmm of suitable length from fitting to the ceiling rose with necessary mounting arrangements including all accessories with new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed. Make: Havells-REGALBATTENT8UPTO1X22WDS BSWH, TUBE-PHOTONULTRAE201212 T8SSTL 20WLED865SPC, C&S Cat No. LTIC00120WLED /WD, Wipro Cat No. WI0921208 incl Tube rod LL 13-181-65SE.
Supply and fix security light luminaire LED 1x25 watts with deep drawn housing including all accessories and LED lamp 25 watts with suitable 25 mm dia GI bracket 0.60 mtr length fixed on wall with 50x6 mm flat iron, clamps, nuts and bolts complete all as specified and as directed. Make: Havells Cat No ENDURASUNDOWNSL25 WLED765PASY BOPCIHD or HALONIX HLSLD-09-25-CWL-R
Supply and fix LED Integrated batten T5 Indoor decorative PVC extruded T5 LED Battens Size - 2 FT 10 watt and colour white etc complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed. Make : Havells Cat Part No LHEXBYPNIN1W010.
S & F sheet metal enclosure MCB DB SPN 8 way with 200 amps rated bus bar 240 volts double door with magnetic locking system complete all as specified and directed.
S & F MCB SPN 415 volts suitable for fixing in MCB DB of capacity 40 / 60 amps complete all as specified and directed.
S & F MCB SP 5 to 30 Amps 240 volts for fixing on MCB DB's complete all as specified and directed.
S&F surface mounted down lighter with die cast aluminium housing with frosted diffuser along with slim type round/square surface mounting LED luminaire 15 watts complete with necessary fixing arrangements and connecting to all accessories with new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and directed. Make:Havells Cat part INTEGRANXTRDDLRSURD 9WLED830S or equivalent in Wipro/Phillips as approved by GE
Supply and fix in replacement surface mounting with perforated sheet with electronic driver luminaire 36 watts LED slim panel (2'x2') with central opal diffuser series mounted in surfaces including all accessories with new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed. Make: Havells Cat No - PLUTOSURFACE2X2PLS 34WLED857S or equivalent in Wipro/Phillips as approved by GE.
S & F in replacement of horizontal type TPN DB 4 way double door made out of CRCA sheet housing with powder coating & conforming to IS 13032, IS 8623, BS 5486 accommodated suitably in a MS enclosure weather proof made out of 3 mm thick MS sheet having hinged and robust locking arrangement including painting by red-oxide one coat and powder coated complete including MCB TPN 63A complete all as specified and as directed. Make : Havells - Cat Part No DHDNTHODAW04, Standard Cat No - DSDNTSODAW04, C&S Cat No - CSDBTPNHPDD04.
M & L for Submain wiring with 2 runs of single core 4 Sqmm PVC insulated unsheated multistranded 1100 volts grade with copper conductor drawn through and including non-metallic rigid PVC surface conduit and conduit accessories of medium grade not less than 20 mm dia including one run of single core 6 Sqmm PVC insulated unsheated multistranded 1100 volts grade with copper conductor cable as earth continuity conductor along with the wiring and connected from DB to DB/main board including removing the existing unserviceable submain wiring complete all as specified and as directed.
Supply and fix new ceiling fans 1200mm, aluminium body, power consumption not more than 28W, BEE 5star rated with BLDC motor, service value greater than 8.4 CMM/W, air delivery minimum 235 CMM, 350RPM compatible with step regulator for speed control suitable for BLDC fan along with down rod of suitable size and length canopy-2 Nos and writing MES No with black paint on new fan and testing complete all as specified.
Supply and fix exhaust fans AC single phase 230/240 V of size 300 mm sweep with louver complete all as specified and as directed.
Supply & Install Water heater storage type, electric, capacity 25 Liters, Including necessary connection of electricity and water supply complete, BEE 5 Star rated complete all as specified and as directed.
Supply laying and testing cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25.00 Sqmm, 4 core complete all as specified and as directed.
Supply laying and testing cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10.00 Sqmm, 4 core complete all as specified and as directed.
Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground to a depth not less than 2.25 mtrs below ground level with top edge of earth plate not less than 1.5 mtrs below normal ground level connected to GI earth wire 4 mm dia drawn through and including GI protection pipe of light grade 15 mm bore by means of bolts, nuts, check nuts and washers including excavation earth work provisioning of PCC chamber made of PCC 1:3:6 RCC cover funnel with wire mesh 20mm dia watering pipe Medium grade, GI protection pipe 20mm dia bore all as specified in Electrical Plate No.3 of SSR Part I, 2009 complete all as specified and as directed.
S & F switch piano single pole flush type 5 amps, 230 volts complete all as specified and as directed.
S & F switch socket combination flush type multipurpose 2/3 pin 5 amps 2 in 1 230 Volts complete all as specified and as directed.
S & F switch socket combination 2 in 1 multipurpose 3/5 pin 5/15 amps flush type with fuse and neon indicator complete all as specified and as directed.
S & F lamp holder insulated body surface bakelite with back plate suitable for angle / batten fittings fixed with wooden/PVC round blocks complete all as specified and as directed.
SAI RUPA CONSTRUCTIONS
VACON INFRASTRUCTURES
M/s GM Constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .