Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Others-The F.D.R. not pledged in favor of S.E. EDC Rudrapur |
Tender Value
Refer Docs
EMD Value
₹75,000
Closing Date
6 Jan 2022, 12:00 pmClosed
Superintending Engineer
Electricity Distribution Circle, Rudrapur ( U.S. Nagar )
Construction of new substation and related lines under 33/11KV s/S. Kanjabagh under EDD,Khatima
2021_UPCL3_40580_1
EDC(USN)40/2021-22
Open Tender
Electrical Works
Item Rate
45 days
Khatima
Pl. refer tender document
3 documents required · 3 mandatory
₹1,180
SE,EDC,Rudrapur
₹75,000
Yes
15 Mar 2022
21 Dec 2021
7 Jan 2022
21 Dec 2021
6 Jan 2022
21 Dec 2021
Amount
Particulars of material
Supply of X-arm Holding Clamps for P.C,.C. Pole made of M.S. flat of size 50X6 mm. with 65x16mm.size ( 2 Nos. ) M.S. Bolt, Nut & washer duly painted by red oxide primer. The clamps should be free from any crack, welding & burrs complete in all respect as per sample.
Supply of X-arm Holding Clamps for STP,SP-55 made of M.S. flat of size 50X6 mm. with 65x16mm.size ( 2 Nos. ) M.S. Bolt, Nut & washer duly painted by red oxide primer. The clamps should be free from any crack, welding & burrs complete in all respect as per sample.
Supply of L.T. Shakel Insulator 75x90mm with nut & bolts.
Supply of L.T. stay Insulator .
Supply of F- Clamps for STP,SP-55made of M.S. flat of size 50X6 mm. with 65x16mm.size ( 2 Nos. ) M.S. Bolt, Nut & washer duly painted by red oxide primer. The clamps should be free from any crack, welding & burrs complete in all respect as per sample.
Supply of Earth Clamps for STP,SP-55made of M.S. flat of size 50X6 mm. with 65x16mm.size ( 2 Nos. ) M.S. Bolt, Nut & washer duly painted by red oxide primer. The clamps should be free from any crack, welding & burrs complete in all respect as per sample.
Supplu of Aluminium Lugs 95MM SQ.
Supplu of Aluminium Lugs 120MM SQ.
Supply of L.T. Clamps for STP,SP-55 made of M.S. flat of size 50X6 mm. with 65x16mm.size ( 2 Nos. ) M.S. Bolt, Nut & washer duly painted by red oxide primer. The clamps should be free from any crack, welding & burrs complete in all respect as per sample.
Supply of l..T. Clamps for P.C.C. Pole, made of M.S. flat of size 50X6 mm. with 65x16mm.size ( 2 Nos. ) M.S. Bolt, Nut & washer duly painted by red oxide primer. The clamps should be free from any crack, welding & burrs complete in all respect as per sample.
Supply of Stay Clamps for P.C.C. Pole, made of M.S. flat of size 50X6 mm. with 65x16mm.size ( 2 Nos. ) M.S. Bolt, Nut & washer duly painted by red oxide primer. The clamps should be free from any crack, welding & burrs complete in all respect as per sample.
Supply of Nut & Bolts( Suitable size ) with washer suitable size for bracing .
Particulars of works.
Cartage of STP.SP-55. including Loading / Unloading from store centre at Haldwani to Khatima JE Store and JE store to site Sub Station Avg..load 60KM.
Cartage of P.C.C. Pole.including Loading / Unloading from store centre at Haldwani to Khatima JE Store and JE store to site Sub Station Avg..load 60KM.
Cartage of Transformer 11/0.4KV,100KVA. Transformer..including Loading / Unloading from store centre at Haldwani to Khatima JE Store and JE store to site Sub Station Avg..load 60KM.
Cartage of Transformer 11/0.4KV,63KVA. Transformer..including Loading / Unloading from store centre at Haldwani to Khatima JE Store and JE store to site Sub Station Avg..load 60KM.
Cartage of small material . including Loading / Unloading from store centre at Haldwani to Khatima Sub Station.Avg..load 60KM.
Errection & of P.C.C. Pole 8.5Mtr long single pole inlcuding digging of pit size 0.6x0.6x1.5M. , filling earth,boulder,fixing of all accessories upto energisation, etc complete work as per RESPO Specification and as per direction of Engineer In Charge.
Errection &of Double P.C.C. Pole 8.5Mtr long single pole inlcuding digging of pit size 0.6x0.6x1.5M. , filling earth,boulder,stone grouting, stone pad and kaing kicking block, fixing of all accessories upto energisation, etc complete work as per RESPO Specification and as per direction of Engineer In Charge.
Errection &of ST Pole SP-55, single pole inlcuding digging of pit size 0.6x0.6x2.15M. , without grouting suppoting proper level and alignment alongwith fitting of all accessories like top channel with the cost of required cement, sand stone with fixing of all accessories upto energisation, etc complete work as per RESPO Specification and as per direction of Engineer In Charge.
Errection &of ST Pole SP-55, Double pole inlcuding digging of pit size 0.6x0.6x2.15M. , without grouting suppoting proper level and alignment alongwith fitting of all accessories like top channel with the cost of required cement, sand stone with fixing of all accessories upto energisation, etc complete work as per RESPO Specification and as per direction of Engineer In Charge.
Febrication and fixing of channel/Angle complete for double pole 100x50mm.incouding fixing of channel with clamps including cutting, drilling holes and fabrication as requrired and direction of Engineer-In-Charge.
Mounting of transformer on D/P Structure and fixing of channel/angle etc, making complete worl of HT& LT connection including complete earthing of transformer. Transormer 11/0.4Kv. 100kva.
Mounting of transformer on D/P Structure and fixing of channel/angle etc, making complete worl of HT& LT connection including complete earthing of transformer. Transormer 11/0.4Kv. 63kva.
Errection & grouting of Stay set including diffing of pit size 0.60x0.60x1.5 Mtr. With stay rod 16x1800mm., stay wire 7/8 swg. With proper nozzeling with back filling of pit with CC 1:4:8 in bottom of pit stay wire 7/8 SWG( Stay set and stay wire will be provided by the department ) and grouting of stay in pit with CC 1:4:8 in bottom of pit in size 0.60x0.60x0.60 Mtr. and earth filling complete in all respect with cost of cement , sand , & stone ballast and supply and fixing of all other items with stay clamps, stay elbow including proper nozelling etc. required for proper completion of work, as per direction of Engineer- In- charge.
Laying , sprreading, stringing and sagging of ACSR Weasel conductor and earth wire in HT complete with fillting of all accessories,binding/jumpering complete complete work upto energisation as per direction of Engineer-In-Charge.
Earthing of Poles on L.A. by way of digging of pit size 50x750x990mm.deep of earth electord upto 100mm. Below and fixing of connection of GI wire 7/16 SWG both at electrod as per direction of Engineer-In-Charge.
Laying , sprreading, stringing and sagging of L.T .line on ACSR weasel conductor wire by providing proper sag including binding etc. fixing of L.T. clamp & insulator complete work as per RESPO specification. 3 phase 4 wire.
Laying , sprreading, stringing and sagging of LT .line on ACSR wesel conductor wire by providing proper sag including binding etc. fixing of L.T. clamp & insulator complete work as per RESPO specification. 1 phase 2wire.
Laying , sprreading, stringing and sagging of LT .line on ACSR wesel conductor wire by providing proper sag including binding etc. fixing ofL.T. clamp & insulator complete work as per RESPO specification. 1 phase to 2phase LT line.
Laying , sprreading, stringing and sagging of LT .line on ACSR wesel conductor wire by providing proper sag including binding etc. fixing ofL.T. clamp & insulator complete work as per RESPO specification. 1 phase to 3phase LT line.
SHAGUN ELECTRICALS AND CONSTRUCTION
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .