Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹59.5 LAccepted-AOC VILLAGE AND POST OFFICE LUJ TEHSIL PANGI DISTRICT CHAMBA | L1 | Accepted-AOC AOC | |
| 2 | L2₹62.6 L+₹2.4 L (4.06%)Rejected-Finance | L2 | Rejected-Finance other than lowest | |
| 3 | L3₹62.7 L+₹2.5 L (4.23%)Rejected-Finance | L3 | Rejected-Finance other than lowest | |
| 4 | L4₹67.1 L+₹6.9 L (11.5%)Rejected-Finance VILLAGE PO BAROHAKRI TEHSIL NIHRI DISTT MAND HP | MANDI | HIMACHAL PRADESH | 175001 | L4 | Rejected-Finance other than lowest | |
| 5 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹72.6 L
EMD Value
₹1.1 L
Closing Date
4 Dec 2023, 5:00 pmClosed
Executive Engineer
Executive Engineer Jal Shakti Division Mandi
Demolition of Old Complaint Cell at Motipur Development of Site of Lab Construction of Lab Physical Chemical Bacteriological Lab at Motipur Mandi Distt Mandi HP
2023_HPIPH_81809_1
MN 11535-84
Open Tender
Civil Works
Item Rate
90 days
Mandi at Motipur
Please refer Tender documents.
7 documents required · 7 mandatory
₹800
Yes
EE Mandi
₹1.1 L
Yes
13 Jun 2024
24 Nov 2023
5 Dec 2023
24 Nov 2023
4 Dec 2023
24 Nov 2023
Amount
Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within all leads and lifts.
Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within all leads and lifts.
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within all leads and lifts.: Of area 3 sq. metres and below.
Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within all leads and lifts.as per direction of Engineer-in-charge : In cement mortar.
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material withinall leads and lifts as per direction of Engineer-in-charge. In cement mortar.
Carriage of extra excavated earth from site of work to dumping site at Bindravani with in all leads and lifts and to the entire satisfaction of the Engineer - in - Charge.
Coursed rubble masonry (second sort) with hard stone in foundation & plinth with : Cement mortar 1:6 (1 cement : 6 coarse sand) within all leads and lifts.
Fixing of fencing panel of size. 1.20 m X 1.20 m including MS hold fast complete in all respect and as per direction on Engineer-in-Charge. Within all leads and lifts.
Providing and Fixing of Cup Board with Action Tesa HDHMR (High Density High Moisture Resistant) One Side Pre Laminated Board of size 18 mm. anti termite and dampness proof with Back including all materials and fittings etc. in all leads and lifts as per the entire satisfaction of the Engineer - in - Charge.
Excavation in foundation and trenches in earth work upto all depth in all kinds of soil such as pick work jumper work,blasting work,chiselling of soft /hard rock where blasting is prohibited in all leads and lifts and including trimming of sides levelling of bed to correct grade stacking the excavated soil in 15cm. layers when required into plinth sides of foundation including consolidating each deposited layer by ramming and watering and then disposing oof all surplus excavated soil as directed in all leads and lifts and soring/strutting timbering and dewatering where ever required to the entire satisfaction of the Engineer-in-charge.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:6:12 (1 cement : 6 coarse sand): 12 graded stone aggregate 40 mm nominal size within all leads and lifts.
Centering and shuttering including strutting, propping etc. and removal of form for all heights : Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. within all leads and lifts.
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window ills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing : 1:5:10 (1 cement : 5 coarse sand) : 10 graded stone aggregate 40 mm nominal size) within all leads and lifts.
Boulder Filling behind retaining wall and breast wall within all leads and lifts.
Providing and fixing high pressure PVC spigot and socket, waste and ventilating pipes ISI marked including fixing with approved adhesive etc. complete.110 mm (One hundred Ten millimetre) dia within all leads and lifts and other incidentals including carriage of materials in all respect and as per direction of Engineer-in-Charge.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand) : 8 graded stone aggregate 40 mm nominal size) within all leads and lifts.
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) within all leads and lifts.
Centering and shuttering including strutting, propping etc. and removal of form for all heights : Foundations, footings, bases of columns, etc. for mass concrete within all leads and lifts.
Centering and shuttering including strutting, propping etc. and removal of form for all heights : Columns, Pillars, Piers, Abutments, Posts and Struts within all leads and lifts.
Centering and shuttering including strutting, propping etc. and removal of form for all heights : Lintels, beams, plinth beams, girders, bressumers and cantilevers within all leads and lifts.
Centering and shuttering including strutting, propping etc. and removal of form for all heights : Suspended floors, roofs, landings, balconies and access platform within all leads and lifts.
Centering and shuttering including strutting, propping etc. and removal of form for all heights : Edges of slabs and breaks in floors and walls Under 20 cm wide within all leads and lifts.
Centering and shuttering including strutting, propping etc. and removal of form for all heights : Stairs, (excluding landings) except spiral-staircases within all leads and lifts.
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand): 3 graded stone aggregate 20 mm nominal size) within all leads and lifts.
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, huttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand) : 3 graded stone aggregate 20 mm within all leads and lifts.
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of entering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand) : 3 graded stone aggregate 20 mm nominal size) within all leads and lifts.
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of entering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand) : 3 graded stone aggregate 20 mm nominal size) within all leads and lifts.
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of entering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand) : 3 graded stone aggregate 20 mm nominal size) within all leads and lifts.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level : Mild steel and Medium Tensile steel bars within all leads and lifts.
Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand) : With Modular bricks within all leads and lifts.
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand) within all leads and lifts.
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron) within all leads and lifts.
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making rovision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron) within all leads and lifts.
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side within all leads and lifts.
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5.50 mm thickness weight not less than 10.00 kg / sqm within all leads and lifts.
Fly proof stainless steel grade 304 wire gauge with 0.5 mm dia. wire and 1.4 mm wide aperture with matching wood beading within all leads and lifts.
Providing and fixing 100mm brass mortice latch & locks with 6 livers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete within all leads and lifts.
Providing and fixing aluminium casement windows fastener of required length for aluminium windows with necessary screws etc. complete. Powder coated minimum thickness 50 micron aluminium within all leads and lifts.
Providing and fixing aluminium round shape handle of outer dia 100 mm with SS screws etc. complete as per direction of Engineer-in-charge Powder coated minimum thickness 50 micron aluminium within all leads and lifts.
6 mm cement plaster of mix in cement mortar 1:3 ( 1 cement : 3 sand) within all leads and lifts.
15 mm cement plaster on rough side of single or half brick wall of mix: 1:4 (1 cement: 4 coarse sand) within all leads and lifts.
Rough cast plaster upto 10 m height above ground level with a mixture of sand and gravel or crushed stone from 6 mm to 10 mm nominal size, dashed over and including the fresh plaster in two layers, under layer 12 mm cement plaster 1:4 (1 cement : 4 coarse sand) and top layer 10 mm cement plaster 1:3 (1 cement : 3 fine sand) mixed with 10% finely grounded hydrated lime by volume of cement within all leads and lifts.
Boulder filling dry hand packed tightly under floors within all leads and lifts.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.(Size of Tile 600x600 mm) within all leads and lifts.
Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding, and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge.In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) Acid and alkali resistant tile within all leads and lifts.
Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding, and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge.In dado/skirting on 12 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) 11.21.2.1 Acid and alkali resistant tile within all leads and lifts.
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick within all leads and lifts.
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete within all leads and lifts.
Providing plinth protection 50 mm thick in cement concrete 1:3:6 (1cement:3sand:6 graded stone aggregate 20 mm nominal size within all leads and lifts.
Proving under layer for plinth protection of 75 mm thick (unconsolidated) bed dry brick/stoneAggregated 40 mm nominal size will rammed with rammed and consolidated and grouted with fine sand including preparation of ground within all leads and lifts.
Constructing course rubble hammer dessed "U" shape open surface drain with side wall 15x22 cm in cement mortor 1:6 (1cement : 6 sand) and inside plastering with cement plaster 1:3 (1cement : 3 sand) including earth work and laayng 10 cm cement concrete in 1:5:10 (1 cement :5 sand : 10 graded stone aggregate 40 mm nonminal size) and 7.5 cm cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size) and finished with a floating coat of neat cement complete as per standard design within all leads and lifts.
Applying Birla white wall care putty over plaster surface after thoroughly brushing the surface free from mortar drops, dust, loose materials and other foreign matters sand papered smooth to give final matter finish to the surface complete within all leads and lifts.
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement primer within all leads and lifts.
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade : Two or more coats on new work within all leads and lifts.
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required : In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works within all leads and lifts.
Providing and Fixing 75 mm x 60 mm rounded hand rails in straight length complete in 1st class indian teak wood within all leads and lifts.
Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required. Group "C"
Wiring for light plug with 2x1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 1 No.1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
Supplying & Fixing of G.I. modular boxes of following sizes along with modular base and cover plate for modular switches in recess as required:- 4 modules (140mmx78mmx50mm)
6 modules (205mmx78mmx50mm)
8 modules (120mmx135mmx60mm)
Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 1 No. HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required. : 2 x 1.50 Sq. mm.
2 x 2.50 Sq. mm.
2 x 4.00 Sq. mm.
Wiring for circuit / sub-main with 4x6 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 2 No.6 Sq.mm. (4x6+2x6) HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
Wiring for circuit / sub-main with 4x10 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 2 No.10 Sq.mm. (4x10+2x10) HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
Supplying and Fixing following rating Modular switch /socket in the existing switch box / cover plate including connections etc. as required. : S.P. 5/ 6 Amps one way Modular switch.
5 pin, 5/ 6 Amps Modular socket outlet.
Bell push, Modular.
Supplying and Fixing following rating Modular switch /socket in the existing switch box / cover plate including connections etc. as required. S.P. 15/ 16 Amps one way Modular switch.
6 pin,15/16 Amps Modular socket outlet.
Supplying and Fixing following rating Modular switch /socket in the existing switch box / cover plate including connections etc. as required. TV. Socket outlet, modular.
Supplying and Fixing following rating Modular switch /socket in the existing switch box / cover plate including connections etc. as required. Telephone socket outlet, Modular.
Supplying and Fixing ceiling rose on the existing junction box / wooden block including connections etc. as required.
Supplying and Fixing of following way, single pole and neutral sheet steel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required:- Double door-12 way
Supplying and Fixing following rating, four pole (three phase & neutral) 415 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 Amps. Cat-A.
Supplying and Fixing sheet metal bus-bar chamber suitable for 200 Amp. 415 volts capacity with 4 No. copper strip bus-bars each of length 450 mm & cross-sectional area (25.4 mm x 4.75 mm), enclosure made from 1.6 mm thick M.S. sheet having overall dimensions (530 mm x 450 mm x 150 mm) nominal with all accessories including connections, earthing the body etc. as required.
Providing and Fixing TP&N switch disconnector fuse unit cubical type, 415/500 volts with 3 No. HBC/HRC fuses, in sheet steel enclosure including drilling holes on the board, connections, earthing the body etc. as required. 100 Amp. Category-A
Supplying and erection of 6 amps. to 32 amps. rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required. Single pole & neutral. Cat-B.
Supplying and erection of wall mounted metal boards for switch gear mounting of suitable size, with permissible variation in size of plus minus 5mm, welded frame work made of M.S. angle iron 35 mm x 35 mm x 6 mm thick duly welded complete with 2.80mm thick M.S. sheet fixed with hinges as open able front, complete with locking arrangement including painting and bonding to the existing earth as required.
Supplying and Fixing following rating, four pole (three phase & neutral) 415 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 Amps. Cat-B.
Supplying and Fixing 20 Amps, 240 volts, SPN industrial socket outlet, 2-pole & earth, metal enclosed plug top, sheet steel enclosure, suitable to accommodate a 20 Amp SPN-MCB/DP, on surface or in recess, with chained metal cover for the socket outlet, complete with connections, testing and commissioning etc. as required.
Earthing with copper earth plate 600 mmx600 mmx 3 mm thick, including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) complete as required.
Extra for using salt and charcoal for G.I. or copper plate earth electrode complete as required.
Providing and Fixing M.V.danger notice plate of 200 mm x 150 mm made of mild steel at least 2 mm thick, and vitreous enameled white on both sides and with inscription in signal red color on front side as required.
Providing and installation of stationary storage type Electric water heater (Geyser) of various sizes by means of Expansion-bolts with nuts and washers, including embedding of expansion-bolts in the wall, providing and Fixing of Non-return valve, Dead weight safety valve, 2 No C.P. connection rods 18" long, making good the damages, electrical connections, safety valve connections, testing and commissioning etc. as required. 25 Liter capacity water heater (Cat-A)
Providing, Installation, testing and commissioning of ceiling fan with regulator, including wiring the down rods of standard length (up to 30 cm) with 16/0.20 mm twin twisted flexible, cotton braided, copper cable, including providing and Fixing phenolic laminated sheet cover on the fan box and earthing etc. as required. Ceiling Fan 1400 mm sweep, Category-A
Providing and installation of exhaust fan of following sizes in the existing opening, including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required. Exhaust Fan, Light duty, (Domestic) 225 mm sweep
Providing and Fixing of Syska make LED Tube Fixture 18 watt complete in all respect in all leads and lifts.
Supplying and Fixing Ding-Dong / Electronic musical bell, suitable for D.C./A.C. single phase,230 volts complete as required:-
Supplying and drawing co-axial TV cable,RG-6 grade,0.7mm (75 Ohms) copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface / recessed, steel / PVC conduit as required.
Supplying and Fixing bakelite batten/angle holder including connections etc. as required.
Providing and fixing high pressure UPVC spigot and socket, waste and ventilating pipes ISI marked including fixing with approved adhesive etc. complete. including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. single equal branch,oval access door,collars, "P" or "S" trap etc., with clamps at 1.20 metre spacing. This includes the costs of cutting chases and including testing of joints complete as per direction of the engineer in charge Concealed work, including cutting chases and making good the wall etc. 110 mm dia
90 mm dia
Providing and Fixing UPVC floor trap ISI marked of self cleaning design including Fixing with approved, cost of cutting and making good the wall and floors etc. complete within all leads and lifts and other incidentals including carriage of materials in all respect and as per direction of Engineer-in-charge. 110 mm x 90 mm.
Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever equired: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests.
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P.brass pillar taps.
Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings.
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms.
Providing and fixing brass bib cock of approved quality : 15 mm nominal bore
Fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall 15 mm dia nominal bore.
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 15 mm nominal bore within all leads and lifts.
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank 1000 Liters within all leads and lifts.
Zakir Hussain
Gajraj Singh
Sudanshu Sood
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .