Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance 077 KHARCHALPUR TAHBARPUR TIKAPUR NIZAMABAD AZAMGARH UTTAR PRADESH 276208 | AZAMGARH | UTTAR PRADESH | 276208 | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Not Admitted-Fee | Not Admitted-Fee Fee not received |
Tender Value
₹35.8 L
EMD Value
₹35,800
Closing Date
25 Jul 2022, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer
SE, EDC-II, Rahul Nagar Madya, Azamgarh
Preventive Maintenance and Breakdown attend Work under EDD-IV, Azamgarh
2022_PVVNV_713508_1
28/EDC-II(A)/2022-23
Open Tender
Repair and Maintenance Works
Item Rate
365 days
Under of the EDD-IV
See Tender Notice
5 documents required · 5 mandatory
₹3,540
EE ETD-II
₹35,800
6 Aug 2022
8 Jul 2022
25 Jul 2022
8 Jul 2022
25 Jul 2022
8 Jul 2022
8 Jul 2022 - 25 Jul 2022
365 days
Amount
lkexzh dk fooj.k ¼FOR site½
11 KV Indoor/Outdoor Jointing Kit
Vacuum Interrupter
Busbar Spout
Jaw Contact
Trip/Closing Coil
Protection Relays (ASHIDA make)
CT Spout
Trip Clutch
fo|qr forj.k [k.M&prqFkZ] vktex<+ dss vUrxZZZZZr 12 vn~n 33@11 ds0oh0 fo|qqr midsUnzksa esa yxs 33 ,oa 11 ds0oh0 la;[email protected] ds preventive maintenance dk dk;Z o"kZ esa nks ckj
budfeax iSusy Work involved- 1. Dusting and Cleaning (by Cleaning agent) of panel to obtain desired IR value. 2. Cleaning of Breaker, oiling and Greasing of moving parts, work of Tripping and closing adjustment, contact resistance measurement of Vacuum Interrupter. 3. Checking and testing of closing/tripping machanism of breaker. 4. Replacement of weaker insulation control cables/Wiring. 5. Cleaning of Jaws and its greasing/oiling. 6. Cleaning of Busbar spout and replacement of spout with lesser IR value. 7. Cleaning of PT, CT and CT spout. 8. Cleaning of Relays through suitable solvent. 9. Adjustment of setting of relays, as required, and consequent testing. 10. Tightening of power and control cable connections/Wiring as required. 11. Heating of panel through blower. 12. Miscellaneous petty works. Note- All T & P and Petty Material/Consumables viz oil, grease, cloth, cleaning solvent, nut, bolt, washer, seals etc shall be arranged by the firm.
vkmVxksbax iSusy Work involved- 1. Dusting and Cleaning (by Cleaning agent) of panel to obtain desired IR value. 2. Cleaning of Breaker, oiling and Greasing of moving parts, work of Tripping and closing adjustment, contact resistance measurement of Vacuum Interrupter. 3. Checking and testing of closing/tripping machanism of breaker. 4. Replacement of weaker insulation control cables/Wiring. 5. Cleaning of Jaws and its greasing/oiling. 6. Cleaning of Busbar spout and replacement of spout with lesser IR value. 7. Cleaning of CT and CT spout. 8. Cleaning of Relays through suitable solvent. 9. Adjustment of setting of relays, as required, and consequent testing. 10. Tightening of power and control cable connections/Wiring as required. 11. Heating of panel through blower. 12. Miscellaneous petty works. Note- All T & P and Petty Material/Consumables viz oil, grease, cloth, cleaning solvent, nut, bolt, washer, seals etc shall be arranged by the firm.
33 ds0oh0 fLop;kMZ WWork involved- 1. Meggering of lightening arresters of all 3 phases of all power transformers of the substations. 2. Mechanical adjustment of bus side and line side TPMO/Isolator, oiling and greasing of moving parts to ensure smooth operation. 3. Pole contact testing of CT. 4. Machanical adjustment, as required, of 33 KV breaker. Oiling and greasing of moving parts to ensure smooth operation. 5. Ensuring local and remote operation of 33 KV breaker (Firm will not be responsible for any defect attributable to department). 6. Cleaning of all swithgears, including transformer, lying in switchyard. Note- All T & P and Petty Material/Consumables viz oil, grease, cloth, cleaning solvent, nut, bolt, washer, seals etc shall be arranged by the firm.
fo|qr forj.k [k.M&prqFkZ] vktex<+ dss vUrxZZZZZr 12 vn~n 33@11 ds0oh0 fo|qqr midsUnzksa ds break down dks attend dj fo|qr vkiwfrZ jh&LVksj djus dk dk;Z&
11 ds0oh0 fLopxh;j dk break down maintenance (Incoming and Outgoing)- 1. Attending flashing caused by any fault or other wise (This includes cleaning through suitable solvent, replacement of damaged CT and PT if required. 2. Work on jaw contact (This includes mechanical adjustment, cleaning and/or replacement of jaws, as required. 3. Work on Vacuum Interrupter Bottle (This includes mechanical adjustment, cleaning and/or replacement of bottles, as required. 4. Work on tripping closing coil (This includes mechanical adjustment, cleaning and/or replacement of coil as required. 5. Work on tripping clutch (This includes mechanical adjustment, cleaning and/or replacement of clutch as required. 6. Replacement of tripping and closing shaft, as required. 7. Removal of flashing in Busbar spout and its replacement, as required. 8. Removal of flashing in CT spout and its replacement, as required. 9. Work on rack out gear and/or jack bush. (This includes greasing, Replacement, as required. 10. Replacement of damaged indoor/outdoor cable box of 11 KV level. 11. Replacement of damaged straight through of 11 KV level. 12. Other works required to attend breakdown. Note- All T & P and Petty Material/Consumables viz oil, grease, cloth, cleaning solvent, nut, bolt, washer, seals etc shall be arranged by the firm.
33 ds0oh0 fLopxh;j dk break down maintenance- 1. Attending breakdown caused by any fault or other wise. This includes A. Cleaning/Repair/replacement of CT, PT LA, B. Repairing/Replacement of damaged line side and/or bus side TPMO. 2. Replacement of damaged indoor/outdoor cable box of 33 KV level. 3. Replacement of damaged straight through of 33 KV level. 4. Miscellaneous works required to be done attend breakdown. 5. Other works required to attend breakdown. Note- All T & P and Petty Material/Consumables viz oil, grease, cloth, cleaning solvent, nut, bolt, washer, seals etc shall be arranged by the firm.
S K Traders
M/S NEW HINDUSTAN CONTRACTOR AND SUPPLIER
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .