Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.9 CrAccepted-AOC 121 MODEL TOWN AMBALA CITY HARYANA 134003 | AMBALA CITY | AMBALA | HARYANA | 134003 | ₹12.9 Cr | L1 | Accepted-AOC Being L1 and reasonable |
| 2 | L2₹15.5 CrRejected-Finance 35 B BHERU VILLAS SARDAR CLUB SCHEME AIR FORCE JODHPUR 342 011 RAJASTHAN | JODHPUR | JODHPUR | RAJASTHAN | 342011 | ₹15.5 Cr | L2 | Rejected-Finance Being other than L1 |
| 3 | L3₹16.5 CrRejected-Finance 15 16 GANGA COLONY KHATIPURA ROAD JAIPUR RAJ 302012 | JAIPUR | JAIPUR | RAJASTHAN | 302012 | ₹16.5 Cr | L3 | Rejected-Finance Being other than L1 |
| 4 | L4₹16.6 CrRejected-Finance 00 00 NAPASAR ROAD NENO KA BASS BIKANER RAJASTHAN BIKANER RAJASTHAN 334022 UDYAM RJ 08 0001676 | BIKANER | RAJASTHAN | 334022 | ₹16.6 Cr | L4 | Rejected-Finance Being other than L1 |
| 5 | L5₹16.9 CrRejected-Finance HOUSE NO 769 SOUTH CIVIL LINES MUZAFFARNAGAR UP 241001 | HARDOI | UTTAR PRADESH | 241001 | ₹16.9 Cr | L5 | Rejected-Finance Being other than L1 |
Tender Value
₹15.4 Cr
EMD Value
₹10.9 L
Closing Date
13 May 2022, 6:00 pmClosed
Chief Engineer Bareilly Zone
Headquarters Chief Engineer Bareilly Zone Military Engineer Services Sarvatra Bhawan Station Road Bareilly Cantt Bareilly 243001
PROVN OF SECURITY WALL ALONG THE TONS RIVER AT IMA DEHRADUN
2022_MES_516266_1
CEBZ/DDN/T-33 OF 2021-22
Open Tender
Civil Works
365 days
DEHRADUN
AS PER NIT
8 documents required · 8 mandatory
₹3,000
GE (P) DEHRADUN
₹10.9 L
Yes
2 Jun 2022
2 Apr 2022
18 May 2022
2 Apr 2022
13 May 2022
30 Apr 2022
2 Apr 2022 - 23 Apr 2022
Amount
SCHEDULE 'A' PART-I (BUILDING WORK)
Construction of Block of Guard room with toilet including staircase and watch tower complete all as specified and directed and as shown on drawings.
Construction of Block of watch tower including staircase complete all as specified and directed and as shown on drawings.
Total amount of Sch 'A' Part II A (Internal Water Supply) (For details see Sch 'A' Part-II A in PDF folder)
SCHEDULE 'A' PART-II B (INTER WATER SUPPLY)
S & F for brass chromium plated shower rose with 150mm long CP shower arm 125mm size revolving type suitable for 15mm bore pipes complete all as specified and directed. Make Hindware Catpart No F160039CP, Parryware Catpart No T9901A1, Cera Catpart No F7010504AB
S & F bib tap, cast copper alloy, fancy type, chromium plated, with cruth or butterfly handle screw down, screwed for 15mm bore GI pipe or for brass ferrule or to GI socket complete all as specified and directed. Make CERA Catpart No F1015151, Hindware Catpart No F570004, Parryware Catpart No T4604A1
S & F fancy type CP brass wall mixer with provision of over head shower connection 15mm dia complete all as specified and directed. Make Hindware Catpart No F200020CP, Parryware Catpart No G2416A1, Jaquar Catpart No SHFLR5281N
S & F fancy type CP brass basin mixer 15 mm dia complete all as specified and directed. Make CERA Catpart No F1015451, Parryware Catpart No T4665A-1, Hindware Catpart No F200014
S & F for brass chromium plated, angle valve fancy type, 15mm dia complete all as specified and directed. Make CERA Catpart No F8040204, Parryware Catpart No T9926A1, Hindware Element angular
Total amount of Sch 'A' Part III -A (INTERNAL ELECTRIFICATION) (For details see Sch 'A' in PDF folder)
SCHEDULE 'A' PART III-B (INTERNAL ELECTRIFICATION)
M & L of new point wiring with 1.5 Sqmm (nominal area) two single core PVC insulated unsheathed multi stranded copper conductor cable 1100 volts grade, FRLS-H grade, concealed PVC conduit 20 mm dia or higher and conduit fittings and all accessories with suitable size of sunk type cast iron or pressed steel terminal box 1.2mm thick, duly painted for mounting of switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet as top cover, including contineous earth wire PVC insulated, unsheathed, multi stranded copper conductor cable 1.5 sqmm (nominal area) FRLS-H grade, green colour, up to common earth and connected to earth dolly compete all as specified and directed. (Note: 1. Colour code will be maintained as per IE rule i.e. Red/Yellow/Blue for phases, Black for Neutral and Green for earth wire. 2. Switch, socket, regulator, bell push will be measured and paid under respective item.)
(a) One light point controlled by one 1-way switch.
(b) One Ceiling/Exhaust fan point controlled by one 1-way .
(c) One three pin 5 Amp socket on same board with other switches.
(d) One three pin 5 Amp socket on independent board
(e) One light point controlled by two 2-way switches, with cables 1.5 sqmm size
(f) All as per item No 9 above but one 3 pin socket outlet 15 Amp independent, with cable 2 x 4.0 Sq mm size, with earth continuity coductor of size 1 x 4 Sq mm complete all as specified and directed.
M&L for point wiring in existing place using 1.5sqmm size PVC insulated, unsheahed 1100 volts grade single core multi-stranded copper conductor cable FRLS-H grade in new PVC casing & caping with and including its all necessary fittings and accessories fixed concealed/Surface, sunk cast iron or 1.2mm thick perssed steel terminal box for mounting fittings and covered with 3mm thick white bakelite/laminated hard glossy surface sheet top cover fixed with brass screws and cup washers including one continuous run of PVC insulated (green colour) 1.50 sqmm size stranded coper conductor cable FRLS-H as in earth wire and connecting all metal parts to common earth dolly complete all as specified and directed. (Note: 1. Colour code will be maintained as per IE rule i.e. Red/Yellow/Blue for phases, Black for Neutral and Green for earth wire. 2. Switch, socket, regulator, bell push will be measured and paid under respective item.) :-
(a) One light point controlled by one 1-way switch.
(b) One ceiling fan point controlled by one 1-way switch through Regulator.
(c) One three pin 5 Amp socket on same board with other switches.
(d) One three pin 5 Amp socket on independent board
(e) One light point controlled by two 2-way switches, with cables 1.5 sqmm size
(f) All as per item No 16 above but one 3 pin socket outlet 15 Amp independent, with cable 2 x 4.0 Sq mm size, with earth continuity coductor of size 4.0 Sq mm complete all as specified and directed.
S&F switch piano one way flush type 5 Amp SP 240 V AC complete all as specified & directed.
S&F switch piano 2-way flush type 5/6 Amp SP 240 V AC complete all as specified & directed.
S&F switch piano flush type 15 Amps SP 250 V AC complete all as specified & directed.
M&L New sub main wiring with 2 Single core PVC insulated unsheathed FRLS-H cable 1100 Volts grade heavy duty copper conductor multistranded of size 4 Sq.mm. (nominal area) drawing in and including 20 mm. dia or higher PVC conduit medium duty concealed/ surface, conduit heavy duty accessories and fittings and Insulated unsheathed FRLS-H cable copper conductor multistranded of size 4.0 Sq. mm. as earth wire upto common earth and connected to earth dolly complete all as specified & directed. Note:- Two run of 4 Sqmm cable and one run of 4 Sqmm cable and one run of 20 mm dia PVC Conduit shall be measured and paid as one unit.
M&L for sub main wiring with 2 Single core PVC insulated unsheathed FRLS-H cable 1100V grade heavy duty copper conductor multistranded of size 6.0 Sq.mm. (nominal area) drawing in and including 20 mm. dia or higher PVC conduit medium duty concealed, heavy duty accessories and fittings and Insulated unsheathed FRLS-H cable copper conductor multistranded of size 1 x 6.0 Sq. mm. as earth wire upto common earth and connected to earth dolly complete all as specified & directed. Note:- Two run of 6 Sqmm cable and one run of 6 Sqmm cable and one run of 20mm dia PVC Conduit shall be measured and paid as one unit.
S & F sheet metal enclosures DB SPN, 240 volt with 100 amps rated copper bus bar for double door 4 way IP-43 DB's lk-09 suitable for one MCB SPN as incoming and 10 MCB SP as outgoing, mounting flush on wall and making good disturbed surfaces complete all as specified and directed.
S & F sheet metal enclosures DB SPN, 240 volt with 200 amps rated copper bus bar for double door 8 way IP-43DB's lk-09suitable for one MCB SPN as incoming and 10 MCB SP as out going, mounting flush on wall and making good disturbed surfaces complete all as specified and directed.
S&F MCB SPN 40-63 Amp,C series 240 volt conforming to ISI marked complete all as specified & directed .
S&F MCB SPN 32 amp,C series 240 volt conforming to ISI marked complete all as specified & directed .
S&F MCB SP, 6-32 amp ,C-series 240 volt conforming to ISI marked complete all as specified & directed.
Supply and fixing of ceiling fan 1200 mm sweep, AC, 230V,50Hz, Minimum air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current (BLDC) motor including remote control with dry cells ,three blades, canopy & down rod of suitable length ,three core flexible copper conductor of suitable size and accessories and writing MES NO on fan (Colour of ceiling fan shall be approved by GE) complete all as specified and directed. Make Orient electric automiser / crompton energion HS / Havells efficiencia
S&F Exhaust fan steel body AC single phase 230 V of size 300 mm sweep with blades and frame and louvers complete all as specified and directed. Make HAVELLS Ventil DSP, Crompton Trans Air, ALMONARD B06W5GWSMW
Supply and fix electric water heater stoarage type of capacity 25Ltr, steel body,copper inner tank, heating element 2KW, BEE 5 Star rated with all accessories such as safety valve, thermostate, NRV, Connection piece etc, complete all as specified and directed. Make Havells Monza, / USHA Aquerra / Racold Classico
S&F LED light fitting 1x20 W,220V AC decorative type with driver ,holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. Make:- 1) Havells - REGALBATTENT8UPTO 1 x 20W SSBSWH (BATTEN) & PHOTONULTRAE2.01213T8SSTL18WLED865 SPC (TUBE) / Phillips-TMC100 1x TLED 13-20w WH(BATTEN) & ) MAS LED 1200mm 18W-865-T-81 (Tube) / Wipro-WIO921208 (Tube Batten) LL13-181-650 (Tube)
S&F LED light fitting mirror type with high out put diffuser 2 feet ,10 watt 220V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. Make:- 1)Philips-BN021LED12S6500PSUGR / C&S-NAKSHATRA-P/10W/W / Wipro-LL20-111-XXX-65NE3(2 ft length)(Trim Neo Series)
S & F LED lamp base B12 (holder type) 7 watts complete all as specified and directed, Make Havells LhLDeueBmL8r007 / Wipro / Philips
S&F LED light bulkhead type with high out put diffuser,10-13.5 watt 220V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. Make:- 1)Havells LheXCgP7in5W013/Bajaj BIBWP 10W LED/Crompton-1739193
S&F Integral LED Street Light Luminaire comprising of high pressure die cast aluminum housing heat resistant toughened glass with frame IP-65 protection road way luminaries with high power LED 35/40 Watt with efficiency 100 lumen/watt at system level, CCT>5700K, with average life class 50,000 burning hours including GI brackete made out of 50mm GI pipe medium grade and MS clamps for fixing of light fitting complete and connected with twin core PVC insulated copper flexible cable with existing point all as specified and directed. Make: 1) Phillips-BRP046 LED 39 CW MR S1 PSU GR / Havells-ENDURAPEARLNEOSL40W LED757 PASYTOPC / Wipro- LR02-451-XXX-57-G1
M&L for earthing complete with using galvanized mild steel earth plate (electrode) 600 mm x 600 mmx 6 mm thick buried directly in ground, earth pit not less than 2.25 mtr deep below ground level with top edge of the earth plate not less than 1.50 m below ground level and earth plate surrounded with adequate quantity of charcoal dust mixed with salt to be packed thickness of 15 cm all round the plate using 4 mm dia GI earth lead wire as earth lead moulded and rivetted to earth plate at one end and connected to main equipment at switch/control board at another end, GI earth lead protected in and including 15 mm dia GI ‘medium grade’ pipe from upper end of earth plate upto equipment with & including 20 mm dia bore GI pipe ‘medium grade’ as water pipe from earth chamber to upper edge of the earth plate, GI funnel with wire mesh fixed on water pipe and provision of PCC 1:2:4 type B1(using 20 mm graded stone agg) as in pits chamber and RCC pit cover 50 mm thick of precast RCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) reinforced with XPM (weight not less than 3 Kg / Sqm) as per electrical plate No.3 of SSR Part-II 2010 and testing on completion all as specified and directed.
S&F sheet metal enclosure with socket plug top & MCBs SPN with a two pin and earth plug and socket complete with single pole MCB of 240V and 20 Amps. complete all as specified and directed.
Total amount of Sch 'A' Part IV (Earth work and site clearance) (For details see Sch 'A' in PDF folder)
Total amount of Sch 'A' Part V 'A' (Road, Path & Culvert) (For details see Sch 'A' in PDF folder)
SCHEDULE 'A' PART V-B (Road, Path & Culvert)
M & L Coloured (red / yellow pattern) glossy finished rubber moulded anti fungus chequered concrete tiles 30 cm x 30 cm x 25 mm thick, set, jointed and pointed in neat cement slurry in floors with pigment complete all as specified and directed.
M & L for Providing and laying 60 mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size / shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding / laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed.
S & F metal tubular delineator made out of ABS round body fitted with 2 Nos 65mm dia highly reflective reflectors made out of PMMA and mounted on 45/50 mm dia steel pipe of 600mm height duly powder coated and thermoplastic elastometer 3 bands of green, red and yellow reflector radium tape of 25 mm wide strips with anti theft steel net for reflector protection including embedding in PCC 1:2:4 (150 x 150 x 300 mm) type B-1 complete all as specified and directed. Make Model No DA 952 GP of dark eye or equivalent in 3M/Mr. illumination / Aktion
Manufacturing, supplying and fixing retroreflective cautionary / warning sign boards of equilateral triangular shape having each side of 900mm with support length of 3650 mm and made up of 2 mm thick aluminium sheet, face to be fully covered with high intensity encapsulated type heat activated retro reflective sheeting conforming to type - IV of ASTM-D 4956-01 in blue and silver white or other colour combination including subject matter, message (bi-lingual), symbols and borders etc as per IRC ; 67 : 2001, pasted on substrate by an adhesive backing which shall be activated by applying heat and pressure conforming to class-2 of ASTM-D-4956-01 and fixing the same with suitable sized aluminium alloy rivets @ 20 cm c/c to back support frame of MS angle iron of size 25 x 25 x 3 mm along with theft resistant measures, mounted and fixed with 2 Nos MS angles of size 35 x 35 x 5mm to a vertical post made up to MS Tee section ISMT 50 x 50 x 6mm welded with base plate of size 100 x 100 x 5mm at the bottom end and including making holes in pipes, angles, flats,providing and fixing MS message plate of required size, steel work to be painted with two or more coats of synthetic enamel paint of required shade and of approved brand and manufacture over priming coat of zinc chromate yellow primer (vertical MS-Tee support to be painted in black and white colours) backside of aluminium sheet to be painted with two or more coats of epoxy paint over and including appropriate priming coat including all leads and lifts etc complete as per drawing, specification and direction of Engineer-in-charge.
M & L for 150 mm thick in two layers (Compated thicknesse) WMM, laid and compacted as per design mix IRC 109-1997 rolled and consolidated to required gradient , camber level, super elevation with 8 to 12 ton power complete all as specified and directed.
Total amount of Sch 'A' Part VI 'A' (Security Wall and Wicket Gate) (For details see Sch 'A' in PDF folder)
SCHEDULE 'A' PART VI-B (Security Wall and Wicket Gate)
S & F concertina coil with punched tape of dia 610 mm having 50 Nos rounds per 6-7 mtrs expendable length, approx weight 7-8 Kg complete all as directed by EIC and as per manufacturer instructions complete all as specified and directed.
S & F Mild steel, plain, black sheet of 3 mm thick as in steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and directed.
Total amount of Sch 'A' Part VII A (Retaining Wall) (For details see Sch 'A' in PDF folder)
SCHEDULE 'A' PART VII B (Retaining Wall)
BLANK
Total amount of Sch 'A' Part VIII-A (Area Drainage) (For details see Sch 'A' in PDF folder)
SCHEDULE 'A' PART VIII-B (Area Drainage)
M & L for Factory Made Drain Covers type B-1 1:2:4 (20 mm graded stone aggregates) in cover slab and similar work including reinforcement as per manufacturers instructions and as directed by engineer in chanrge including formwrok complete all as specified and directed. Make TULIP / NTC / MEHTAB
Total amount of Sch 'A' Part IX 'A' (Sewage Disposal) (For details see Sch 'A' in PDF folder)
SCHEDULE 'A' PART IX-B (Sewage Disposal)
M & L for Construction of septic tank 50 users capacity with excavation and earth work in any type of soil, PCC 1:2:4 type B2 in foundation, brick work in CM 1:4, RCC M-25 using 20 mm graded crushed aggregate as specified, duly reinforced with 8mm TMT bar @ 120mm c/c manhole covers, angle iron frame, vent shaft and sludge chamber etc. complete all as specified, directed and shown on drawing No TD - 217 sheet 1/7 to 7/7.
M&L for soakage well with size 1.2m dia x 3.0 m effective depth including excavation in any type of soil, foundation in PCC 1:3:6, walls of honeycombed masonry with top ring of M-25 concrete including intercepting chamber and screen chamber made of brick masonry in Cement mortar, RCC cover slab in M-25, interconnecting pipes of RCC complete filled with brick bats complete all as specified and directed.and shown on drawing No TD -309 sheet 1/4 to 4/4.
Total amount of Sch 'A' Part X 'A' (External Water Supply) (For details see Sch 'A' in PDF folder)
SCHEDULE 'A' PART X-B (External Water Supply)
Cutting cast iron / GI pipe 150 / 100 mm bore, in position for insertion of new tees of suitable size including jointing materials complete all as specified and directed
M & L for construction of valve chamber 600 x 600 x 600 mm internal dimensions, 4 mm thick MS sheet cover with 2 Nos MS hinges welded to angle iron frame of 40mm x 40mm x 6 mm thick with lifting hook and locking arrangement complete with necessary earth work, brick work in CM (1:6), 230 mm thick, PCC bed (1:4:8) type D2 150 mm thick, cement plastering, finishing 15 mm thick in CM (1:4) and applying a coat of black bituminous paint to the steel surfaces complete all as specified, shown on drawing and directed.
Total amount of Sch 'A' Part XI 'A' (External Electric Supply) (For details see Sch 'A' in PDF folder)
SCHEDULE 'A' PART XI-B (External Electric Supply)
M & L for cross arms, bracing, supports, clamps, and back plates fabricated from structural steel section including nuts, bolts, & washers, welding bending cold or hot, drilling holes for bolts washers in any shape or size as indicated or directed and including two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
Supply, install and testing air break gang operated triple pole switch mechanically operated mounted on 12 insulators with dio fuse complete with operating mechanism work out from ground level including locking arrangement and steel frame up to current rating 200 Amps with expulsion fuse single pole element as required rupturing capacity. The switch having rating 11 KV including electrical connection and testing complete all as specified and directed.
Supply, Install, connect, testing and commissioning of Step down Transformer out door type copper wound three phase, 4 wire, 415/433 volts 50Hz on primary side,11000 volts, 3 phase, 3 wire on secondary side 415/433, Copper wound oil immersed, naturally cooled, with tapings on primary side to vary secondary voltage from (-) 7.5 % to (+) 7.5 % with steps at every 2.5 % variation with standard fittings / fixtures, with extended cable end box on LT side with neutral brought out complete with initial fill of transformer oil to appropriate level as suggested by the manufacturer, temperature gauge, breather, bucholz relay, cooling coil, suitable size cable glands on LT side, bushing on HT side all as specified confirming to IS : 1180:2014 Part-I of capacity 100 KVA including standard accessories, fitting as per manufactures specification and the following Make-SCHENIDER / ABB / CROMPTON GREAVES Contd.....
(a) Lifting lugs for transformer and tank (b) Earthing terminals and tatting diagram plate. (c) Air release device. (d) Oil filling inlet pipe with plug (e) Drain out gate valve. (f) Conservator with level indicator. (h) Initial oil filing with new oil to required level as per IS 335. Contd.....
(j) Delta/star type connection (k) ONAN cooling (l) DNY 11 vector group (m) Cable end box suitable for 3 1/2 core 400 sqmm XLPE cable on LT side. (n) Danger notice plate - 1 No (o) Thermometer with pocket (p) 03 Nos porcelains HV bushing with arching horns on HV side suitable for 11 KV complete with bushing rods & nuts.
Supply and install in replacement steel poles shall be swaged type & shall conform to IS 2713 (parts I to III) 1998. A through hole of 14mm diameter shall be provided in each pole at a height of 300 mm above the planting depth for earthing arracngements, finials and with CI base plate and finial taper plug, bolts, nuts & screws as specified type 410 SP 55, (11.0 Mtr long) plate shall be of cast iron, protection against corrosion. The poles shall be coated with two coats of black bitumonous paint through out internally and externally up to the planting depth. The remaining portion of the exterior with one coat of red oxide / emulsion paint & two coat of aluminium paint and two coats of zebra marking with enamel from ground level and up to 1 mtr height including white washing and coping the cleaning / cutting bushes surrounding the pole bottom upto 1 mtr radius complete all as specified and directed. Make JINDAL / TATA / NATIOANL TUBE Note All Earthwork and concrete work shal be measured and paid seperately under respective items involved in this schedule.
BLANK
Supply & Fix of LED based street light fitting, made up of Pressure Die Cast Housing LM 6 Alloy / Anti Dust Exposed Lens,sturdiness and embossed brand name/logo name of manufacturer, a minimum system efficacy is greater than 110 lumen / Watt and a minimum system lumen output of 5900 lumens and maximum system wattage of 50 / 60 Watts, a CRI of minimum 70, designed for a system life of 50,000 hours @70% lumen maintenance,. Ingress Protection of IP66 (lamp and gear Compartment) and Mechanical Impact Resistance Rating of IK >=08, driver should have an operating voltage range of 140-270 V, surge protection of >=4KV, PF >0.9 , and SDCM<5. The driver should be BIS approved, fully potted and encapsulated with 440V Stress Voltage protection for 8 Hrs. High Cut off : 325V(+/- 15V) and Auto Restart function should also be available within the fixture..The fixture should comply with the parameters as per IS10322. The LED driver should comply to IEC61000-3-2 ed.3.2, 2009 for Harmonics, IEC61347 -2 -13, 2006 in Conjunction with IEC61347-1 ed.2.0, 2007 for Electrical Safety, IEC62384 ed.1.1, 2011 for performance and IEC61547 ed.2.0, 2009, CISPR-15 for EMI. Make:- Philips CAT No. - BRP056 LED59S CW PSU / Havells ENDURAPEARLNEOSL60WLED757PASYTOPC / WIPRO-LR02-671-XXX-57-G2 complete all as specified and directed.
S & F fuse box sheet metal enclosure made out of MS sheet not less then 02 mm thick factory fabricated front openable duly painted and of size 300 X 250 X 100 mm having bakelite connector suitable for 3 phase and neutral link including MCB SP 6 amps gunmetal cable gland for LT cable fixed to pole with MS 25 X 3 mm GI clamps made to shape with required nut bolt washers etc. for street light fittings complete all as specified and directed.
Supply and erection, testing and commissioning of 20 meter high mast lighting system with electrically operated raising and lowering motorised system comprising the Mast shaft shall be in two sections hot dip galvanised inside and outside in single dip, and having bottom dia. not less than 485 mm and tip dia not less than 200 mm suitable for bearing wind velocity as per IS 875 (Part III). There shall be only one longitudinal seam weld per section and no circumferential well it shall also include accessories for high mast including head frame. 2 point suspension system with steel wire rope 6mm dia 97/19 construction double drum winch for lifting & lowering of high mast light manually if electricity is not available during electric supply breakdown including galvanised lantern carriage arrangements suitable for 08 luminaries symmerically and its CG boxes and lighting final, the mast shall have integral type power tool with suitable capacity motor and travelling cable :at the base compartment for the it operation capable for lifting & lowering 08 Nos LED luminaires with and including following items:- Make Crompton / Bajaj / Havells Contd.......
(a) Construction of suitable shallow RCC foundation with M-20 grade stone concrete including foundation bolts nuts washers anchor plate and items plates made from special steel including excavation and earth work as per manufacture instructions/ decision for erection of High Mast. (b) LED aviation obstruction light luminaire comprising of aluminium housing with poly carbonate enclosure type BGAV 302 LED-01 Nos (c) Control panel suitable for control circuit for automatic switching on/off of the mast. The control panel shall also have necessary controls for power tool including earthing complete. Contd.......
(d) LED Integral flood light luminaries with secondary optics made in pressure dia cast housing and heat sink aluminium extrusion and IP-66 protection of 250W LED fitting including control gear boxes with suitaible size of wiring of luminaries with all wiring including fixes on high mast light- 08 Nos. Make- Bajaj/Philips/ Crompton/ Havellse-InduraPearlGrandPlussl250Wled757PasYtotG (e) Out door LT feeder pillar box with MCCB 63 Amps, 10 KA, 4 pole as incommer and suitable out goings, including push botton starters to operate power tool (reversable motor), phase indicator lamps (RYB), digital panel meter (VAFPP) shall be provided for the control of above lights with equal power distribution. Multi stranded and multi core copper conductor cable of suitable size for connecting LT panel to light fittings shall be provided as directed . Make-L&T/SCHNEIDER/ABB/SIEMENS
Supply and fix LED Flood light aluminium diecast housing luminarie with unique lens system for enhance uniform illumination and toughened glass with silicon gasket for IP 66 protection 240-250W complete all as specified and directed. Make Wipro, cat No LF20-342-060-57-G2/Havells-JetaValourfl240Wled757modnBltG/Philips-BVP410 LED 250 CW HE NB FG S4 XTFCL
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door) 415 Volts, dust proof,vermin proof made out of CRCA sheet 3.15 mm thick duly compartmentalized inside panel with 2 mm thick CRCA sheet , to accommodate the incoming and outgoing each switch gear shall have be independent opening, and having provision for front and rear side opening with rubber beading, suitable size bus bar and mild steel cable glands for each cable to make it weather and vermin proof. double door hinged type, both side openable, air fins for ventilation, panel shall be mounted on ISMC Chanel of size (50 x 50 x 6 mm) & duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer supported on 04 legs suitable long each duly grouted in plain cement concrete blocks in 1:2:4 type B1 (using 20 mm graded stone aggregate) incl all connections incoming / out going complete all as specified and comprising of following accessory :-(Main LT Panel near Tfr) Make-L&T/SCHNEIDER/ABB/INDOASIAN INCOMING MCCB 4 Pole, 200 Amps ,415 Volt of breaking capacity 35 KA with Adjustable Thermal and Adjustable Magnetic - 01 Nos with extended rotary handle and spreader set. Contd....
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door) 415 Volts, dust proof,vermin proof made out of CRCA sheet 3.15 mm thick duly compartmentalized inside panel with 2 mm thick CRCA sheet , to accommodate the incoming and outgoing each switch gear shall have be independent opening, and having provision for front and rear side opening with rubber beading, suitable size bus bar and mild steel cable glands for each cable to make it weather and vermin proof. double door hinged type, both side openable, air fins for ventilation, panel shall be mounted on ISMC Chanel of size (50 x 50 x 6 mm) & duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer supported on 04 legs suitable long each duly grouted in plain cement concrete blocks in 1:2:4 type B1 (using 20 mm graded stone aggregate) incl all connections incoming / out going complete all as specified and comprising of following accessory :-(LT panel near long range) Make-L&T/SCHNEIDER/ABB/INDOASIAN INCOMING MCCB 4 Pole, 63 Amps ,415 Volt of breaking capacity 25 KA with Adjustable Thermal and Adjustable Magnetic - 01 Nos with extended rotary handle and spreader set. Contd....
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door) 415 Volts, dust proof,vermin proof made out of CRCA sheet 3.15 mm thick duly compartmentalized inside panel with 2 mm thick CRCA sheet , to accommodate the incoming and outgoing each switch gear shall have be independent opening, and having provision for front and rear side opening with rubber beading, suitable size bus bar and mild steel cable glands for each cable to make it weather and vermin proof. double door hinged type, both side openable, air fins for ventilation, panel shall be mounted on ISMC Chanel of size (50 x 50 x 6 mm) & duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer supported on 04 legs suitable long each duly grouted in plain cement concrete blocks in 1:2:4 type B1 (using 20 mm graded stone aggregate) incl all connections incoming / out going complete all as specified and comprising of following accessory :-(LT Panel near bamboo post). Make-L&T/SCHNEIDER/ABB/INDOASIAN INCOMING MCCB 4 Pole, 40 Amps ,415 Volt of breaking capacity 25 KA with Adjustable Thermal and Adjustable Magnetic - 01 Nos with extended rotary handle and spreader set. Contd....
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door) 415 Volts, dust proof,vermin proof made out of CRCA sheet 3.15 mm thick duly compartmentalized inside panel with 2 mm thick CRCA sheet , to accommodate the incoming and outgoing each switch gear shall have be independent opening, and having provision for front and rear side opening with rubber beading, suitable size bus bar and mild steel cable glands for each cable to make it weather and vermin proof. double door hinged type, both side openable, air fins for ventilation, panel shall be mounted on ISMC Chanel of size (50 x 50 x 6 mm) & duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer supported on 04 legs suitable long each duly grouted in plain cement concrete blocks in 1:2:4 type B1 (using 20 mm graded stone aggregate) incl all connections incoming / out going complete all as specified and comprising of following accessory :-(LT panel near helipad) Make-L&T/SCHNEIDER/ABB/INDOASIAN INCOMING MCCB 4 Pole, 63 Amps ,415 Volt of breaking capacity 25 KA with Adjustable Thermal and Adjustable Magnetic - 01 Nos with extended rotary handle and spreader set. Contd....
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door) 415 Volts, dust proof,vermin proof made out of CRCA sheet 3.15 mm thick duly compartmentalized inside panel with 2 mm thick CRCA sheet , to accommodate the incoming and outgoing each switch gear shall have be independent opening, and having provision for front and rear side opening with rubber beading, suitable size bus bar and mild steel cable glands for each cable to make it weather and vermin proof. double door hinged type, both side openable, air fins for ventilation, panel shall be mounted on ISMC Chanel of size (50 x 50 x 6 mm) & duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer supported on 04 legs suitable long each duly grouted in plain cement concrete blocks in 1:2:4 type B1 (using 20 mm graded stone aggregate) incl all connections incoming / out going complete all as specified and comprising of following accessory :-(LT Panel near dhobi ghat) Make-L&T/SCHNEIDER/ABB/INDOASIAN INCOMING MCCB 4 Pole, 40 Amps ,415 Volt of breaking capacity 25 KA with Adjustable Thermal and Adjustable Magnetic - 01 Nos with extended rotary handle and spreder set. Contd....
Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door) 415 Volts, dust proof,vermin proof made out of CRCA sheet 3.15 mm thick duly compartmentalized inside panel with 2 mm thick CRCA sheet , to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with rubber beading, suitable size bus bar and mild steel cable glands for each cable to make it weather and vermin proof. double door hinged type, both side openable, air fins for ventilation, panel shall be mounted on ICMC Chanel of size (50 x 50 x 6 mm) & duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer supported on 04 legs suitable long each duly grouted in plain cement concrete blocks in 1:2:4 type B1 (using 20 mm graded stone aggregate) incl all connections incoming / out going complete all as specified and comprising of following accessory :-(LT Panel near CR gate) Make-L&T/SCHNEIDER/ABB/INDOASIAN INCOMING MCCB 4 Pole, 25 Amps ,415 Volt of breaking capacity 25 KA with Adjustable Thermal and Adjustable Magnetic - 01 Nos with extended rotary handle and spreder set. Contd....
M&L for earthing complete with using galvanized mild steel earth plate (electrode) 600 mm x 600 mmx 6 mm thick buried directly in ground, earth pit not less than 2.25 mtr deep below ground level with top edge of the earth plate not less than 1.50 m below ground level and earth plate surrounded with adequate quantity of charcoal dust mixed with salt to be packed thickness of 15 cm all round the plate using 4 mm dia GI earth lead wire as earth lead moulded and rivetted to earth plate at one end and connected to main equipment at switch/control board at another end, GI earth lead protected in and including 15 mm dia GI ‘medium grade’ pipe from upper end of earth plate upto equipment with & including 20 mm dia bore GI pipe ‘medium grade’ as water pipe from earth chamber to upper edge of the earth plate, GI funnel with wire mesh fixed on water pipe and provision of PCC 1:2:4 type B1(using 20 mm graded stone agg) as in pits chamber and RCC pit cover 50 mm thick of precast RCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) reinforced with XPM (weight not less than 3 Kg / Sqm) as per electrical plate No.3 of SSR Part-II 2010 and testing on completion all as specified and directed.
All as per S item no 87 ,above but using galvanised iron strip 32 x 6mm as earthing lead.and protection pipe of 40mm dia medium grade Complete all as specified and directed. Note 03 Nos Quantity is for Sch A Part XIII (Standy Supply) and remaining Quantity is for Sch A Part XI (External Electric Supply).
S & F high intensity revolving search light, energy saving, long range 300 watt , beam range 700 mtr IP 66 high lumen LED>140 lm/w, PF>0.095, CCT:5000K-6500K, CRI> 70, optical garde PMMA// PC reflector efficiency>95% multiple circuit to avoid complete run down, narrow beam 7 degree, die cast LM6 body with air fins constant current , avarage lux (in 500mm) at 10mtr away 2500 to 6000 complete with stand and driver complete all as specified and directed. Make -Kalin CSLRFLL25-PC30/Crompton/Scorpion
SCHEDULE 'A' PART XII (Cooling Appliances)
Supply and fix water cooler electric driven single phase having approx storage capacity 40 ltr and nominal cooling capacity 40 ltr,fully stainless steel complete all as specified and directed.
Supply and fix voltage stablizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stablized at 230 volt with accuracy +/-2.5 % and capacity 1 KVA complete all as specified and directed.
Total amount of Sch 'A' Part XIII 'A' (Standby Supply) (For details see Sch 'A' in PDF folder)
SCHEDULE 'A' PART XIII B (Standby Supply)
Supply and installation of silent Diesel Engine driven generating set 415 volts, 3 phase 4 wire, water cooled suitable for ambient conditions complete with relay panel, Engine instrumentation control panel consisting of monitoring system housed in the Power control panel having meter showing net out put, 3phase, power factor, frequency and RPM including switch gears for automatic starting on main failure with AMF panel complete with sound proof canopy as per CPCB norms and foundation etc with following :- Make- Caterpillar/Kirloskar /Cummins/Stamford Contd......
(a) Alternator :- Standard design alternator rated at 100 KVA net output at site after considering de-rating as per site conditions at power factor 0.8 AC 3phase, 4wire, 415 Volts, 50 cycles, 1500 RPM, self excited, self regulated screen protected drip proof IP-23 enclosure brushless design with hub and shield ball/roller bearing with winding in each pole faces insulating class 'H' band of voltage, regulation +/- 1% of rated voltage from no load to full load. The alternator shall be conforming to IS4722/BS2613, Suitable for close coupling with space heaters of suitable capacity. (b) Diesel Engine :- Adequate capacity not less than 124 HP diesel engine suitable to above alternator (exact BHP should be as per suitable manufacturer equivalent model) of kirloskar or equivalent. Water cooled turbo charged with after cooler to drive independently above alternator directly coupled through flexible coupling multi cylinder, multi stroke direct injection cold starting, 1500 RPM as per relevant IS / BS 5514 part -5 with an over load capacity of 10% for 1 hour in any 12 hours continuous running complete with standard accessories all as specified and required for safe handling and operations. Salient feature shall be as under :- Contd......
(i) Fly wheel with housing (ii) Air cleaner (iii) Fuel filter (iv) Fuel injection system with injection pump solenoid switch, nozzles, electronic governor etc. (v) Lubricating oil filter (vi) Lubricating oil pump. (vii) Electric starting eqpts comprising of the following :- (a) Batteries of capacity as recommended by manufacturer copper leads of adequate size complete with initial charging. (b) Starter motor (c) Starter gearing. (d) Start and stop push button (e) Battery charging gen with regulator. (f) Ignition Key / switch. (viii) Silencer complete with exhaust piping upto and out side the building adequate to create draft for safe exhaust without transferring vibration to building/walls duly insulated with asbestos roping of 50 +/ - 10 mm circumference. Contd........
(ix) Engine protection devices including audio indicators and cut off system during following instances : - (a) Low lubrication oil pressure (b) high coolant temperature. (c) Over speeding of engine. (d) Radiator with radiator fan and fan belts. (e) Water pump. (f) Thermostat. (g) Radiator fan& Belt guards. (xi) Hour meter. (xii) RPM indicator. (xiii) Fuel tank capacity adequate for 12 hours running at full load with level indicating arrangement stop cock, drain plug and fuel supply pump complete with piping from tank to pump and to engine including return of over flow. (xiv) Air intake system. (xv) Hand priming pump. (xvi) Common base plate for mounting engine and alternator. (xvii) Exhaust system as per manufacturer design (xviii) Turbo charger with after cooler (xix) Anti corrosive resistor (xx) Fuel off solenoid (xxi) AVM's (xxii) Electronic instrumentation panel.
Total amount of Sch 'A' Part XIV 'A' (Demolition / Dismantling) (For details see Sch 'A' in PDF folder)
SCHEDULE 'A' PART XIV B (Demolition / Dismantling)
Dismantling barbed wire fencing complete all as specified and directed.
Note : Tenderers may note that amount of credit Rs 3,44,480.00 will be deducted from the total amount arrived, at the time of Acceptance of contract.
RAGHUSONS INFRA ENGINEERING PVT. LTD
BHARATSHAH CONSTRUCTION CO
A.S. CONSTRUCTION CO.
M/s Arihant Builders
Jai Ambey Construction Co.
B S Ranbir and Co
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid