Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.1 CrAccepted-AOC NOT AVAILABLE | FARIDABAD | HARYANA | 121004 | ₹2.1 Cr | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹2.1 Cr+₹2.8 L (1.36%)Rejected-Finance | ₹2.1 Cr+₹2.8 L (1.36%) | L2 | Rejected-Finance other then lowest bidder |
| 3 | L3₹2.3 Cr+₹21.9 L (10.5%)Rejected-Finance | ₹2.3 Cr+₹21.9 L (10.5%) | L3 | Rejected-Finance other then lowest bidder |
| 4 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹2.2 Cr
EMD Value
₹2.5 L
Closing Date
17 Dec 2021, 5:00 pmClosed
EXECUTIVE ENGINEER
EE JS Division Chauntra
PLWSS to GP Tikari Mushehara, Bharyara, Chauntra and Prain Sainthal etc. in Tehsil Joginder Nagar District Mandi H.P under JJM SH Co intake , Sed. Tank, filter bed, Main storage tank sector storage tank, Laying, Jointing and testing of Rising Main ,S
2021_HPIPH_53650_1
10466-515 datd 15.11.2021
Open Tender
Civil Works - Water Works
Item Rate
270 days
Chauntra
Please refer Tender documents.
10 documents required · 10 mandatory
₹2,500
EE CHAUNTRA
₹2.5 L
Yes
5 May 2022
17 Nov 2021
18 Dec 2021
17 Nov 2021
17 Dec 2021
17 Nov 2021
Amount
Excavation in foundation and trenches etc. up to all depths and in all classification of earth work such as pick work, jumper work, saturated soil including bailing or pumping out of water, blasting soft or hard rock or chiselling / wedging out of soft/hard rock , where blasting is prohibited, in all lifts including trimming and dressing of sides, levelling of beds to correct grade including shoring, strutting , planking, timbering and dewatering where ever required. Stacking usable and unusable material /soil seperataly , returning the usable soil in 15cm layers by ramming and watering and then dISOsing of all surplus excavated soil/ unusable material as directed within all leads/ lifts complete in all respects within all leads and lifts as per direction of the Engineer-in-charge.
Providing and laying cement concrete 1:3:6 (1 cement:3sand:6 graded stone aggregate 40mm nominal size) and curing complete excluding cost of centring & shuttering in oundation and plinth.within all leads and lifts as per direction of the Engineer-in-charge.
Providing and laying cement concrete 1:4:8 (1 cement:4sand:8 graded stone aggregate 40mm nominal size) and curing complete excluding cost of form work in foundation and plinth.within all leads and lifts as per direction of the Engineer-in-charge.
Providing and laying cement concrete 1:1.5:3 (1cement:1.5 sand : 3graded stone aggregate 20mm nominal size) and curing complete excluding cost of form work and re-inforcement for reinforced concrete work in :
Foundations, footings, bases of columns and the like and mass concrete.
Walls ( any thickness but not less than 0.1 m thickness) attached pillasters, buttresses, plinth and string courses, etc. from top of foundation level upto floor two level.
Prov.form work of ordinary timber plankings so as to give a rough finish i/c centring, shuttering,strutting & propping etc. ht.of propping & centring below supporting floor to ceiling not exceeding 4 mts. & removal of the same for insitu-reinforced concrete & plain concrete work in :-within all leads and lifts as per direction of the Engineer-in-charge.
Arches beyond 6.00 mts.span
Prov.in RCC work smooth finishing of the exposed surface with cement mortor1:3(1cement :3 sand )within all leads and lifts as per direction of the Engineer-in-charge.
Providing & laying cement concrete 1:1:2 (1Cement:1sand:2 graded stone aggregate 20mm nominal size) & curing complete excluding the cost of form work & reinforcement for RCC work in :-
Suspended floor,roofs,landing & shelves & their support balconies,beams,girders,bressumers & cantilever upto floor level.within all leads and lifts as per direction of the Engineer-in-charge.
Arches upto floor two level.
Steel work welded in built up sections,trusses & framed work i/c cutting,hoisting & fixing in position & applying a priming coatof red paint :- In grating, framed ,guards,bars, ladders,railing,brackets & similar works.within all leads and lifts as per direction of the Engineer-in-charge.
Laying in trenches GMS/MS Tubes (L/M class) tube fitting (Earth work in trenches to be measured & paid for separately)within all leads and lifts as per direction of the Engineer-in-charge.
Providing & fixing CI Sluice valve (with hand wheel) as per IS : 780-1984 class-I upto 300 mm dia.(i/c brass spindle & as per 2906-1984 class-II for dia.> 300 mm) complete with bolts nuts,rubber insertion etc.,(the tail piece if required shall be measured & paid for separatly)within all leads and lifts as per direction of the Engineer-in-charge.
Constructing chamber for sluice valve, with CI surface box 100 mm top dia.,160 mm bottom dia. & 180 mm deep(inside) with chained lid RCC top 1:2:4 mix (1 cement :2 sand :4 graded stone aggregate 20 mm nominal size) 100mm thick foundation concrete 1:5:10 mix (1cement : 5 sand : 10 graded stone aggregate 40 mm nominal size) & inside plastering with cement mortor 1 :3 (1 cement : 3 sand) finished with a floating coat of neat cement i/c curing complete. 600 x 600 x 750 mm inside size With 150 mm thick walls of RCC 1:2 :4 (1 cement :2 sand :4 graded stone aggregate 20mm nominal size) complete with form work & reinforcement with 6 mm bars at not exceeding 150 mm centres both ways within all leads and lifts as per direction of the Engineer-in-charge.
Prov. & fixing SFRC Man hole cover with frame having frames size of 560 mm internal dia.should not be less than 100 kg
Providing tor steel reinforcement for R.C.C. work including bending, binding and placing in position complete upto floor two level.within all leads and lifts as per direction of the Engineer-in-charge.
Providing form work with steel plates 3.15mm thick welded with angle iron in frame 30x30x5mm so as to give a fair finish I/c centring , shuttering , strutting and proping etc.with wooden battens and ballies, height of propping and centring below supporting floor to ceiling not exceeding 4mtrs. and removal of the same for insitu- reinforced concrete & plain concrete work in :-within all leads and lifts as per direction of the Engineer-in-charge.
Foundations, footings, bases of columns and the like and mass concrete.
Vertical surfaces such as walls (any thickness& shape), partitions and the like including attached pillasters, buttress,plinth and string courses and the like.
Flat surfaces such as soffits of suspended floors , roofs,landings and the like.Floors etc up to 200mm in thickness.
Laying and jointing of G.I. Pipes (light grade),tube fittings in trenches I/c earth work complete for inlet , outlet and scour :-within all leads and lifts as per direction of the Engineer-in-charge.
50 mm dia
Prov .and fixing Gun Metal Wheel valve (with hand wheel) within all leads and lifts as per direction of the Engineer-in-charge.
50 mm diameter
80 mm dia
Providing and laying cement concrete 1:2:4 ( 1 cement : 2 Sand : 4 graded stone aggregate , 20 mm nominal size ) and curing complete excluding cost of form work and reinforcement in :within all leads and lifts as per direction of the Engineer-in-charge.
Suspended floor roofs, landing and shelves and their support balconies, beams,girders,bressumers and cantilevers up to floor two levels.
Providing and fixing precast concrete man hole cover and frame conforming to IS-12593-1988, part-I & IS-12592-1991, part-II for 500mm diameter medium dury.within all leads and lifts as per direction of the Engineer-in-charge.
Providing and placing in horizontal layers filtering media duly graded, screened,cleaned and washed as specified :
Top layer, Fine sand( Eff. Size 0.20mm to 0.40 and uniformity co-efficient 2.00 to 3.00).
Second layer, Coarse sand, 3mm - 6mm
Third layer : Bajri 6mm to 20 mm.
Fourth layer : Bajri 20mm to 25 mm
Bottom layer : Broken stone 50mm to 75 mm.
Providing & placing Precast Concrete Block in CC 1:2:4 ( I cement :2 sand ;4 graded stone aggrigate 20 mm nominal size)over X Drain
Laying,jointing ( by way of circumfrential flange jointing of various flanges by electrical arc welding ) and testing of Galvanised mild steel tubes (GI Pipes) of following dia meters confirming to BIS 1239-2001 (latest with upto date amendments) having wall thickness as per code with bevelled / plain ends in a random length of 4 to 7 meters, including manufacturing reducers/ tapers , all short pieces, bends etc. as per site requirement made from parent tubes . The laying of pipe will include all operation such as cutting, welding, jointing, fabrication of bends, tees etc. including lowering and laying in excavated trenches to ensure required level including flushing, cleaning and hydraulic testing complete in all respects to the satisfaction of the Engineer in charge. The fabricated bends shall have three or four cuts having its radius not less than five times the dia of pipe. The damaged portion of the pipes and specials made form the parent tube during welding or otherwise shall be provided anticorrosive treatment by applying two coats of anticorrosive bituminous paint over a priming coat as per AWWA specifications C-203-1978. The welding electrodes shall be as per IS 814 of Advani Oerlikon/ L&T or ISI marked make. The rates also includes entire carriage of material, flushing, cleaning & hydraulic testing complete to the best satisfaction & direction of Engineer in charge with in all leads and lifts. (Earth work in trenches will be measured and paid for separately).
80 mm dia , (Medium class) Flange table-17
Laying,jointing ( by way of circumfrential butt welded joints by electrical arc welding ) and testing of Galvanised mild steel tubes (GI Pipes) of following dia meters confirming to BIS 1239-2001 (latest with upto date amendments) having wall thickness as per code with bevelled / plain ends in a random length of 4 to 7 meters, including manufacturing reducers/ tapers , all short pieces, bends etc. as per site requirement made from parent tubes . The laying of pipe will include all operation such as cutting, welding, jointing, fabrication of bends, tees etc. including lowering and laying in excavated trenches to ensure required level including flushing, cleaning and hydraulic testing complete in all respects to the satisfaction of the Engineer in charge. The fabricated bends shall have three or four cuts having its radius not less than five times the dia of pipe. The damaged portion of the pipes and specials made form the parent tube during welding or otherwise shall be provided anticorrosive treatment by applying two coats of anticorrosive bituminous paint over a priming coat as per AWWA specifications C-203-1978. The welding electrodes shall be as per IS 814 of Advani Oerlikon/ L&T or ISI marked make. The rates also includes entire carriage of material, flushing, cleaning & hydraulic testing complete to the best satisfaction & direction of Engineer in charge with in all leads and lifts. (Earth work in trenches will be measured and paid for separately).
80 mm dia , (Medium class)
PUMPING MACHINERY for Tube well 1- Supply of submersible pumping set of KSB/Kirloskar/Johnstion/ Hindustan make comprising to latest relevant BIS Code. The pump should be fitted with bronze impeller of suitable alloys as per BIS 8034-1978 latest suitable for clear water having greased packed bearings and shaft with wound stator on motor side and with shaft protection sleeve on pump side ensuring better life for shaft coupled to submersible squirrel cage electrical induction motor (water proof type) or required HP, RPM 2900 of reputed make conforming to BIS 9283-1979 latest with up to date amendments, totally dust and water proof for submersible duty isolated from the pump by intermediate casing with double mechanical seal in oil chamber and grease packed lubricated bearings and provided with stainless steel thrust bearing plate to with stand non vertical load with minimum wear and tear. It should also be fitted with a device to take up expansion of water with the heating of motor. The pump set should include water level guards, errection clamps, PUMP OPERATING CONDITIONS Discharge: 3.40 LPS for each pump set Total head in Mts. 62.53 mtrs. Length of R/Main 100 Rmtr. Dia of R/Main 80 mm Pumping hours 8 Hours Limits of total head in which the pump/ motor is reqd. to operate. (+)10% & (-) 15%
Supply and erection of suitable oil immersed star delta starter/ATS/star rotor starter of standarad make such as MEI/Kilburn/Jyoti/ Siemens conforming to BIS-8544-1979 latest with up to date ammendments for squirrel cage/slipriing motor (make to be specified by the tenderers) mounted on panel board with magnetic type over load release & dashpot,time lag,under voltage release with initial oil filling .
Providing and fixing M S sheet 16 SWG steel fabricated floor mounted closed almirah type switch board including angle iron post of suitable height and size ISA 40x40x6mm duly painted comprising and capable of mounting the following accessories with all internal electric connections including installation. The drawing of panel board shall be subject to approval of Engineer in charge.
c) ICTP switches with HRC fuses Kilburn/Larsen & turbo/Standard/Siemen make and having capacity 30% extra of the operational rating of motor as per BIS 4064-1978 with upto date ammendments immediatly after the power meter of HPSEB.
d) Busbar chamber having 3 copper bars of suitable rating for full length equal to width of board of 3 live phases and one copper bar of half reating of full length for neutral conforming to BIS 8084-1976 and 11353-1985 read with 5578-1985 all latest with upto date ammendments.
e) MCB/Oil circuit breaker of suitable capacity of Kilburn/LT/LK/MEI/Standard make on in coming feeder for motors offered by the tenderer conforming to BIS 2516-1985 latest with upto date ammendments with neutral linked under voltage release.
f) 3 phase indicating lamps complete with toggle switches for individual motors conforming to BIS 3452 part I & II latest with up to date ammendments.
g) Earth leakage circuit breaker of recommended (Kilburn/L&T/MEI/GEC as per BIS-2516-1977 with upto date ammendments and of suitaible range with which should have control box, operating handle and trip/reset bush button on/ off indicators, re-indicating off spring condition of the circut breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tap CTS. It should also be fitted with earth fault for tripping of breaker on occurance of earth fault on/ off breaker load side.
h) Hour run meter of reputed make of four digit capacity conforming to BIS-722(latest edition) recommendations.
i) Suitable three phase voltage monitor relay with all protections & usual indicators with electrical sirens against single phasing, no voltage, high voltage & overloading & phase voltage difference.
j) Single phase preventor of reputed make & suitable capacity
k) Supply and erection of Kirloskar/ Kilburn/IVC/ Fouress/ Gled/ BHEL/ Leader/ Kartar of approved make of suitable size Cast iron double flanged sluice valve having size one step higher to delivery of pump and capable of withstanding nominal seat pressure as per BIS.
Supply & erection of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEEL/Leader Cast iron double flanged swing check type reflux valve having bye pass arrangement & size one step higher to delivery of pump and capable of withstanding nominal seat pressure as per BIS.
Supply & erection of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEEL/Leader Cast iron double flanged swing check type reflux valve having bye pass arrangement & size equal to dia of rising main for withstanding nominal seat pressure as per BIS.
Providing and Laying suitable size copper PVC insulated armoured power 3.1/2 core cable confirming to BIS 1554 (Part I) -1988 or latest with up to date ammendments Siemen/Gloster/ICC make from meter of HPSEB to OCB & from OCB to Busbar switch & starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles,flexible pipe,solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor .The type,size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
Providing and Laying PVC jointless flat water proof cable as per BIS 694-1990 (latest with up to date ammendments) suitable for the pump sets offered from OCB to motor, motor to starter including all other electrical equipments such as Thimbles, flexible pipes, solder,nuts & bolts,cable glands etc. laid in pipes or trenches. The type,size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
Supply & errection of floor/wall mounted power factor shunt capacitor conforming to BIS 2834-1986 latest with upto date ammendments BHEL/GEC/Machneil/ Mager/Bajaj make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually,of required KVAR according to HP of motor offered including cable Siemens/ Gloster/ICC make from busbar chamber to capacitor & also including LT/LK/Kilburn make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer.
Supply and erection of standarad make 100 mm dia circular dial pressure gauge of suitable range Fiebeg/Bourden/ Precision make with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 latest with up to date ammendments.
Providing and Laying Delivery pipe considering site requirements,NPSH required & available having area equal to two times the area of delivery branch of pump including tapers,flanges,rubber gaskets 3mm thick as per BIS-2712-1978 , nuts & bolts as per 1364-1983 & special from pump set to ground level i/c common header and up to 5 mtrs. away from the outer wall of pump house as per layout drawings approved by Engineer-in-Charge The pipes shall be capable of withstanding 1.5 times the total presure indicated in item no. 1e(ii). NOTE:- Actual laying to be done as per final drawings to be approved by the Engineer in charge.
PUMPING MACHINERY for Tube well 2- Supply of submersible pumping set of KSB/Kirloskar/Johnstion/ Hindustan make comprising to latest relevant BIS Code. The pump should be fitted with bronze impeller of suitable alloys as per BIS 8034-1978 latest suitable for clear water having greased packed bearings and shaft with wound stator on motor side and with shaft protection sleeve on pump side ensuring better life for shaft coupled to submersible squirrel cage electrical induction motor (water proof type) or required HP, RPM 2900 of reputed make conforming to BIS 9283-1979 latest with up to date amendments, totally dust and water proof for submersible duty isolated from the pump by intermediate casing with double mechanical seal in oil chamber and grease packed lubricated bearings and provided with stainless steel thrust bearing plate to with stand non vertical load with minimum wear and tear. It should also be fitted with a device to take up expension of water with the heating of motor. The pump set should include water level guards,errection clamps, cable clips and depth gauge etc. and suitable for opration on data given below :- PUMP OPERATING CONDITIONS Discharge: 3.40 LPS for each pump set Total head in Mts. 72.80 mtrs. Length of R/Main 350 Rmtr. Dia of R/Main 80 mm Pumping hours 8 Hours Limits of total head in which the pump/ motor is reqd. to operate. (+)10% & (-) 15%
Supply and erection of suitable oil immersed star delta starter/ATS/star rotor starter of standarad make such as MEI/Kilburn/Jyoti/ Siemens conforming to BIS-8544-1979 latest with up to date ammendments for squirrel cage/slipriing motor (make to be specified by the tenderers) mounted on panel board with magnetic type over load release & dashpot,time lag,under voltage release with initial oil filling .
Providing and fixing M S sheet 16 SWG steel fabricated floor mounted closed almirah type switch board including angle iron post of suitable height and size ISA 40x40x6mm duly painted comprising and capable of mounting the following accessories with all internal electric connections including installation. The drawing of panel board shall be subject to approval of Engineer in charge.
c) ICTP switches with HRC fuses Kilburn/Larsen & turbo/Standard/Siemen make and having capacity 30% extra of the operational rating of motor as per BIS 4064-1978 with upto date ammendments immediatly after the power meter of HPSEB.
d) Busbar chamber having 3 copper bars of suitable rating for full length equal to width of board of 3 live phases and one copper bar of half reating of full length for neutral conforming to BIS 8084-1976 and 11353-1985 read with 5578-1985 all latest with upto date ammendments.
e) MCB/Oil circuit breaker of suitable capacity of Kilburn/LT/LK/MEI/Standard make on in coming feeder for motors offered by the tenderer conforming to BIS 2516-1985 latest with upto date ammendments with neutral linked under voltage release.
f) 3 phase indicating lamps complete with toggle switches for individual motors conforming to BIS 3452 part I & II latest with up to date ammendments.
g) Earth leakage circuit breaker of recommended (Kilburn/L&T/MEI/GEC as per BIS-2516-1977 with upto date ammendments and of suitaible range with which should have control box, operating handle and trip/reset bush button on/ off indicators, re-indicating off spring condition of the circut breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tap CTS. It should also be fitted with earth fault for tripping of breaker on occurance of earth fault on/ off breaker load side.
h) Hour run meter of reputed make of four digit capacity conforming to BIS-722(latest edition) recommendations.
i) Suitable three phase voltage monitor relay with all protections & usual indicators with electrical sirens against single phasing, no voltage, high voltage & overloading & phase voltage difference.
j) Single phase preventor of reputed make & suitable capacity
k) Supply and erection of Kirloskar/ Kilburn/IVC/ Fouress/ Gled/ BHEL/ Leader/ Kartar of approved make of suitable size Cast iron double flanged sluice valve having size one step higher to delivery of pump and capable of withstanding nominal seat pressure as per BIS.
Supply & erection of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEEL/Leader Cast iron double flanged swing check type reflux valve having bye pass arrangement & size one step higher to delivery of pump and capable of withstanding nominal seat pressure as per BIS.
Supply & erection of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEEL/Leader Cast iron double flanged swing check type reflux valve having bye pass arrangement & size equal to dia of rising main for withstanding nominal seat pressure as per BIS.
Providing and Laying suitable size copper PVC insulated armoured power 3.1/2 core cable confirming to BIS 1554 (Part I) -1988 or latest with up to date ammendments Siemen/Gloster/ICC make from meter of HPSEB to OCB & from OCB to Busbar switch & starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles,flexible pipe,solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor .The type,size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
Providing and Laying PVC jointless flat water proof cable as per BIS 694-1990 (latest with up to date ammendments) suitable for the pump sets offered from OCB to motor, motor to starter including all other electrical equipments such as Thimbles, flexible pipes, solder,nuts & bolts,cable glands etc. laid in pipes or trenches. The type,size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
Supply & errection of floor/wall mounted power factor shunt capacitor conforming to BIS 2834-1986 latest with upto date ammendments BHEL/GEC/Machneil/ Mager/Bajaj make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually,of required KVAR according to HP of motor offered including cable Siemens/ Gloster/ICC make from busbar chamber to capacitor & also including LT/LK/Kilburn make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer.
Supply and erection of standarad make 100 mm dia circular dial pressure gauge of suitable range Fiebeg/Bourden/ Precision make with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 latest with up to date ammendments.
Providing and Laying Delivery pipe considering site requirements,NPSH required & available having area equal to two times the area of delivery branch of pump including tapers,flanges,rubber gaskets 3mm thick as per BIS-2712-1978 , nuts & bolts as per 1364-1983 & special from pump set to ground level i/c common header and up to 5 mtrs. away from the outer wall of pump house as per layout drawings approved by Engineer-in-Charge The pipes shall be capable of withstanding 1.5 times the total presure indicated in item no. 1e(ii). NOTE:- Actual laying to be done as per final drawings to be approved by the Engineer in charge.
PUMPING MACHINERY for Tube well Phase VI Tube well 1- Supply of submersible pumping set of KSB/Kirloskar/Johnstion/ Hindustan make comprising to latest relevant BIS Code. The pump should be fitted with bronze impeller of suitable alloys as per BIS 8034-1978 latest suitable for clear water having greased packed bearings and shaft with wound stator on motor side and with shaft protection sleeve on pump side ensuring better life for shaft coupled to submersible squirrel cage electrical induction motor (water proof type) or required HP, RPM 2900 of reputed make conforming to BIS 9283-1979 latest with up to date amendments, totally dust and water proof for submersible duty isolated from the pump by intermediate casing with double mechanical seal in oil chamber and grease packed lubricated bearings and provided with stainless steel thrust bearing plate to with stand non vertical load with minimum wear and tear. It should also be fitted with a device to take up expension of water with the heating of motor. The pump set should include water level guards, errection clamps,cable clips and depth gauge etc. and suitable for opration on data given below :- PUMP OPERATING CONDITIONS Discharge: 3.40 LPS for each pump set Total head in Mts. 62.53 mtrs. Length of R/Main 100 Rmtr. Dia of R/Main 80 mm Pumping hours 8 Hours Limits of total head in which the pump/ motor is reqd. to operate. (+)10% & (-) 15%
Supply and erection of suitable oil immersed star delta starter/ATS/star rotor starter of standarad make such as MEI/Kilburn/Jyoti/ Siemens conforming to BIS-8544-1979 latest with up to date ammendments for squirrel cage/slipriing motor (make to be specified by the tenderers) mounted on panel board with magnetic type over load release & dashpot,time lag,under voltage release with initial oil filling .
Providing and fixing M S sheet 16 SWG steel fabricated floor mounted closed almirah type switch board including angle iron post of suitable height and size ISA 40x40x6mm duly painted comprising and capable of mounting the following accessories with all internal electric connections including installation. The drawing of panel board shall be subject to approval of Engineer in charge.
c) ICTP switches with HRC fuses Kilburn/Larsen & turbo/Standard/Siemen make and having capacity 30% extra of the operational rating of motor as per BIS 4064-1978 with upto date ammendments immediatly after the power meter of HPSEB.
d) Busbar chamber having 3 copper bars of suitable rating for full length equal to width of board of 3 live phases and one copper bar of half reating of full length for neutral conforming to BIS 8084-1976 and 11353-1985 read with 5578-1985 all latest with upto date ammendments.
e) MCB/Oil circuit breaker of suitable capacity of Kilburn/LT/LK/MEI/Standard make on in coming feeder for motors offered by the tenderer conforming to BIS 2516-1985 latest with upto date ammendments with neutral linked under voltage release.
f) 3 phase indicating lamps complete with toggle switches for individual motors conforming to BIS 3452 part I & II latest with up to date ammendments.
g) Earth leakage circuit breaker of recommended (Kilburn/L&T/MEI/GEC as per BIS-2516-1977 with upto date ammendments and of suitaible range with which should have control box, operating handle and trip/reset bush button on/ off indicators, re-indicating off spring condition of the circut breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tap CTS. It should also be fitted with earth fault for tripping of breaker on occurance of earth fault on/ off breaker load side.
h) Hour run meter of reputed make of four digit capacity conforming to BIS-722(latest edition) recommendations.
i) Suitable three phase voltage monitor relay with all protections & usual indicators with electrical sirens against single phasing, no voltage, high voltage & overloading & phase voltage difference.
j) Single phase preventor of reputed make & suitable capacity
k) Supply and erection of Kirloskar/ Kilburn/IVC/ Fouress/ Gled/ BHEL/ Leader/ Kartar of approved make of suitable size Cast iron double flanged sluice valve having size one step higher to delivery of pump and capable of withstanding nominal seat pressure as per BIS.
Supply & erection of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEEL/Leader Cast iron double flanged swing check type reflux valve having bye pass arrangement & size one step higher to delivery of pump and capable of withstanding nominal seat pressure as per BIS.
Supply & erection of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEEL/Leader Cast iron double flanged swing check type reflux valve having bye pass arrangement & size equal to dia of rising main for withstanding nominal seat pressure as per BIS.
Providing and Laying suitable size copper PVC insulated armoured power 3.1/2 core cable confirming to BIS 1554 (Part I) -1988 or latest with up to date ammendments Siemen/Gloster/ICC make from meter of HPSEB to OCB & from OCB to Busbar switch & starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles,flexible pipe,solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor .The type,size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
Providing and Laying PVC jointless flat water proof cable as per BIS 694-1990 (latest with up to date ammendments) suitable for the pump sets offered from OCB to motor, motor to starter including all other electrical equipments such as Thimbles, flexible pipes, solder,nuts & bolts,cable glands etc. laid in pipes or trenches. The type,size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
Supply & errection of floor/wall mounted power factor shunt capacitor conforming to BIS 2834-1986 latest with upto date ammendments BHEL/GEC/Machneil/ Mager/Bajaj make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually,of required KVAR according to HP of motor offered including cable Siemens/ Gloster/ICC make from busbar chamber to capacitor & also including LT/LK/Kilburn make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer.
Supply and erection of standarad make 100 mm dia circular dial pressure gauge of suitable range Fiebeg/Bourden/ Precision make with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 latest with up to date ammendments.
Providing and Laying Delivery pipe considering site requirements,NPSH required & available having area equal to two times the area of delivery branch of pump including tapers,flanges,rubber gaskets 3mm thick as per BIS-2712-1978 , nuts & bolts as per 1364-1983 & special from pump set to ground level i/c common header and up to 5 mtrs. away from the outer wall of pump house as per layout drawings approved by Engineer-in-Charge The pipes shall be capable of withstanding 1.5 times the total presure indicated in item no. 1e(ii). NOTE:- Actual laying to be done as per final drawings to be approved by the Engineer in charge.
SS RANA CONSTRUCTION PRIVATE LIMITED
SANGRAM NAIK
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .