Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹37.4 LAccepted-AOC P O BINNAGURI 735203 DISTT JALPAIGURI W B | JALPAIGURI | WEST BENGAL | 735203 | L-1 | Accepted-AOC Being L-1 | |
| 2 | L-2₹39.9 L+₹2.1 L (5.57%)Rejected-Finance NEAR KRIPAN GATE PO BINNAGURI DIST JALPAIGURI W B PIN 735203 | JALPAIGURI | WEST BENGAL | 735203 | L-2 | Rejected-Finance Being L-2 | |
| 3 | L-3₹40.7 L+₹2.9 L (7.78%)Rejected-Finance PO PS BANARHAT DIST JALPAIGURI PIN 735202 W B | JALPAIGURI | WEST BENGAL | 735202 | L-3 | Rejected-Finance Being L-3 | |
| 4 | L-4₹41.5 L+₹3.7 L (9.74%)Rejected-Finance | L-4 | Rejected-Finance Being L-4 | |
| 5 | L-5₹41.6 L+₹3.9 L (10.2%)Rejected-Finance DURGA NAGAR CHECK POST PO ETHELBARI DIST ALIPURDUAR PIN 735204 WB | ALIPURDUAR | WEST BENGAL | 735204 | L-5 | Rejected-Finance Being L-5 |
Tender Value
₹36.2 L
EMD Value
₹72,400
Closing Date
25 Sept 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (North) Binnaguri
GE North Binnaguri Post Binnaguri Dist Jalpaiguri West Bengal PIN - 735232
ADDN/ALTN OF BUILDING NO OM-01 IN BINNAGURI MILITARY STATION UNDER GE (NORTH) BINNAGURI
2024_MES_662843_2
NIT No. 8701 / 20 / 2024-25 / 07 / E8
Open Tender
Civil Works
Item Rate
180 days
BINNAGURI CANTONMENT
Class D Category a (i)
8 documents required · 8 mandatory
₹500
GE (North) Binnaguri
₹72,400
Yes
26 Oct 2024
10 Sept 2024
27 Sept 2024
10 Sept 2024
25 Sept 2024
18 Sept 2024
Amount
Demolition of brickwork built in cement mortar including all quions, arches, pillars etc complete all as specified and as directed.
Demolition of cement concrete (un-reinforced) in ground floors and pavings n.exc 15 cm thickness (below or above ground level) complete all as specified and as directed.
Demolition of reinforced cement concrete of any description and in any position not other wise specifically provided for all complete all as specified and as directed.
Surface dressing n.exc 15 cm deep and getting out soft loose soil complete all as specified and as directed.
Excavation in trenches, n exc 1.5m wide and n.exc 1.50m depth for foundation for taking up/ laying under ground electric cable etc and getting out in soft/loose soil complete all as specified and as directed.
Excavating over areas, n exc 1.5m deep and getting out in soft/loose soil complete all as specified and as directed.
M&L for cement concrete type D2 1:4:8 (using 40mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and as directed.
M&L for 40 mm thick PCC 1:2:4 Type B-0 using 12.50 mm graded stone aggregate as in Damp proof course to horizontal or vertical surface including necessary form work complete all as specified and as directed.
Material & Labour applying evenly a coat of blown type bitumen 85/25 @ 1.50 Kg per Sqm and blinding with clean dry sand @ 0.05 cum/sqm complete all as specified and as directed.
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required including crabking, bending spirally for hooping for column, hooking ends and binding with including mild steel wire annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed.
All as per item No 10 above but 6 to 08 mm dia complete all as specified and as directed.
All as per item No 10 above but 5mm dia and over upto to and including 10mm dia as in stirrups, spacers and binders complete all as specified and as directed.
M&L for Formwork to sides of concrete foundations, footings, plinth beam etc. flat, rough finished surfaces of concrete complete all as specified and as directed.
M&L for Formwork to sides of concrete for column pillars, square, rectangular or polygonal for rough finished surfaces of concrete complete all as specified and as directed.
M&L for Form work to sides and soffits of floor or roof beams, lintels, cantilevers, flat for rough finished surfaces of concrete complete all as specified and as directed.
Form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick (Horizontal or sloping) flat for rough finished surfaces of concrete complete all as specified and as directed.
M&L for Formwork to chullah hoods, chajjas, troughs and similar items including edges flat for rough finished surfaces of concrete complete all as specified and as directed.
M&L for Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified and as directed.
M&L for RCC M25 (Design Mix) as in foundation, footings, plinth beam, bases for columns etc complete all as specified and as directed.
M&L for RCC M25 (design Mix) as in Columns, pillars etc. complete all as specified and as directed.
M&L for RCC M-25 (design mix) as in Beams, cantilevers, lintels over 1.5 m span etc. complete all as specified and as directed.
M&L for RCC M-25 (design mix) as in chajjas complete all as specified and as directed.
M&L for RCC M25 (Design Mix) as in slab supported on walls, beam, columns in floor, roof, shelves complete all as specified and as directed.
M&L for providing RCC M25 (Design Mix) as in lintels upto 1.5m clear span, lintel bend ,cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60cm in height, copings, kneelers, apex stones, bed plates, kerbs , water through and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed.
Spreading and leveling in layers n exc. 25 cm thick as in plinth filling etc complete all as specified and as directed.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed.
M&L for anti-termite treatment by treating the back fill in contact with foundation at the rate of @7.5 lit of emulsion per sqm of vertical surface (Area of the sub structure in contact with backfill to be measured) complete all as specified and as directed.
M&L for anti-termite treatment by treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and as directed.
M&L for anti-termite treatment by treating the soil alongwith external perimeter of building @ 2.25 ltr of emulsion per meter of the perimeter wall complete all as specified and as directed.
M&L for anti-termite treatment by treating the soil under plinth protection at the rate of 5.0 ltr of emulsion per square meter of the surface area complete all as specified and as directed.
M&L for hardcore of gauge n exc .63mm, deposited, spread and leveled in layers 100 mm thick broken stone or boulders watered and rammed to a true surface complete all as specified and as directed.
M&L for Brickwork with fly ash bricks, straight or curved on plan any radius in half brick thick built in CM (1:4) complete all as specified and as directed.
M&L for brick work with fly ash brick, straight or curved on plan exc 6 m mean radius built in CM 1:6 complete all as specified and as directed.
M&L for 75mm thick PCC (1:4:8) type D2 in sub base using 40mm graded aggregate complete all as specified and as directed.
M&L for PCC (1:2:4) type B1 using 20mm graded stone aggregate 25mm thick as in flooring complete all as specified and as directed.
M&L for 1st quality double charged/ultra charged Vitrified Ceramic tiles light/dark shade 7-8mm thick (square/rectangular) polished, area of each tiles not exceeding 1.0 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or colored cement to match over screed bed CM (1:6) 15mm thick complete all as specified and as directed. Note: Design and pattern shall be approved by Engr-in-charge /GE at the time of execution of work.
All as per above item No 37 but as in skirting over 10mm thick cement plaster (1:4) complete all as specified and as directed.
M&L for Non Skid ceramic coloured tiles 7- 8mm thick (squares/ rectangular) area of each tile not exceeding 1.0 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over screed bed CM (1:6) 15mm thick complete all as specified and as directed.
All as per above item No 39 but as in skirting over 10mm thick cement plaster (1:4) complete all as specified and as directed.
M&L for DIGITAL ELEVATION TILES of size 300x600x7-8mm thick on vertical surfaces such as skirting, dados and riser to steps etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10mm thick rendering in CM 1:4 as backing coat complete all as specified and directed by Engineer-in-charge. Note: Design and pattern shall be approved by Engr-in-charge /GE at the time of execution of work.
M&L for Providing and laying of 10mm thick Anti-Skid pavement tiles of approved size, color & Shade and in anti skid finish set and jointed in neat cement slurry and pointed in white cement & pigment to match over and including 20 mm thick screed bed in cement mortar 1:4 complete all as specified and as directed. Note: Design and pattern shall be approved by Engr-in-charge /GE at the time of execution of work.
M&L for PCC (1:2:4) type B0 (12.5mm graded stone aggregate) as in coping cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets etc complete all as specified and as directed.
M&L for PCC 1:2:4 type B1 using 20 mm graded stone aggregate as in roof kerbs complete all as specified and as directed.
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished even and fair (without using extra cement) complete all as specified and as directed.
M&L for applying average 15 mm thick plaster in two coats (10+5mm) with ready-mix pre-packed proportioned dry mix mortar, blended with PP fibres, mixed with liquid water proofing compound on fair faces of brick wall or concrete surfaces additives on external surfaces including transporting of material, mixing, curing, scaffolding etc finished the surface even and fair with out using extra cement complete all as specified and as directed. Note : Liquid water proofing compound will be measured and paid separately as supply only. Note: Water proofing compound will be measured and paid separately.
M&L for rendering 5mm thick on ceiling surfaces in cement plaster 1:3 and finished even and fair (without using extra cement) complete all as specified and as directed.
Supply only liquid water proofing compound complete all as specified and as directed.
M&L for rendering 10 mm thick screed bed on roof slab concrete surfaces , in cement and sand mortar 1:4 using water liquid water proofing compound @ 200 ml per bag of cement or as per manufacturer's instructions (WPC shall be measured and paid separately) complete all as specified and as directed.
M&L for providing and applying single component acrylic polymer modified, fibre reinforced waterproof coating in 4 coats of application (a) applying primer coat with Primer @ 0.3 kg /sqm (b) over priming coat applying as specified below or manufacturer instructions with fibre reinforcement a width of approx 1m @ 0.75kg/sqm on the flat or vertical surfaces over parapet wall and ensure that there are no bubbles of creases. Overlapping of the fibre is a minimum of 50mm and allow this coat to dry for a period of 2-6 hrs depending on the atmospheric condition. (c) Applying second coat of roof guard @0.75Kg/sqm (d) Applying final coat of primer @ 0.08kg/sqm after 2nd coat has dried properly. Note : Water Proofing treatment shall be carried out by authorized applicator approved by the manufacturer.
M&L for 18 to 20 mm thick granite (of any type) work (table rubbed and polished) in steps, Jambs, pillars, window cills, cooking platforms, corner shelf, Flat shelf and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite and including 15 mm thick cement plaster (1:4) including rounding the exposed surfaces of granite complete all as specified and as directed.
All as per item No 51 above but as in skirting 12 to 15mm thick grantee and on 10mm thick rendering/back coating in CM (1:4) complete all as specified and as directed.
M&L for granules textured homogeneous wall finishing system consisting of a two component system of dry granules (25 Kgs pack) made of 92% silica particles coated with fade resistant pigments, 100% acrylic polymer bonding agent (5 Kgs pack) with the applied thickness of the coating being between 0.8 mm - 1.2 mm to be applied on cured, smooth level plastered surface, as per manufacturer's directions, applied by approved applicator of the manufacturer as per the directions / supervision of the Engineer-In-Charge, all complete. The above textured coating should conform to surface spread of flame class one of BS 476 : Part 7 : 1971 and pull off strength of the coating to meet JISA 6909 all as specified and as manufacturers specifications / instructions.
M&L for waterproof cement based putty of average thickness 1 mm and sand papering surfaces to achieve smooth surfaces over new plastered surface on wall / ceiling / chajjas after preparation of surface and applying two coats of distemper acrylic emulsion of approved tint over a coat of alkaline resistant primer with roller including washing floors, cleaning glass, joinery, electrical fittings, wiring etc of drops and splashes complete all as specified and as directed by Engineer-in-Charge.
M&L for preparation of new plastered surfaces on wall / ceiling / chajjas and applying two or more coats of 10-0% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 Ltre/10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 Sqm over new/old surfaces as per the manufacturer instruction and all coats including primer to be applied with fully automatic airless spray machine of paint application with flow speed of minimum 1 Ltr per minute having pressure of 3300 PSI. Allow 6-8 hrs to dry the surface in subsequent coats of paint complete all as specified and as directed.
S&F for GI frame work for seamless ceiling comprising of FI perimeter channel 0.55 mm thick with two unequal flange of 20 and 30 mm dia and Web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre / intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended form soffit at approx 900 mm centre to centre with FI cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 mm length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete all as specified and as directed. Note: Design and pattern shall be approved by Engr-in-charge /GE at the time of execution of work.
M&L for providing and fixing Gypsum Board 12mm thick in ceiling fixed with screws as per manufacturers instructions fixed or laid/ inserted to timber/GI/Aluminium framework 4mm thick with screws complete all as specified and as directed. Note: Design and pattern shall be approved by Engr-in-charge /GE at the time of execution of work.
S&F for Gypsum Board 12 mm thick cornices up to 100 mm wide along the false ceiling on vertical surfaces fixed with cadmium plated screw complete all as specified and as directed. Note: Design and pattern shall be approved by Engr-in-charge /GE at the time of execution of work.
S&F 2nd class hardwood Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and as directed.
M&L for Melamine polishing on wooden surfaces of any description, width or girth including cleaning and preparing the surface including a coat of wood filler on new works with two or more coats etc complete all as specified and as directed.
S&F factory made 40mm flush shutter, machine pressed architects veneer designer ply lam both side flush door shutter solid core construction with block board core including 5mm thick teakwood lipping around complete as specified and directed by Engineer-in-Charge. Note: Design and pattern shall be approved by Engr-in-charge /GE at the time of execution of work.
S&F milds steel framed work such as grills, gratings, for fly proof door shutter etc. with ends of bars, hollow sections shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks, notching for wire, flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or riveting, welding etc and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed.
S&F of Stainless Steel butt hinges, medium weight cold rolled of size 100mm complete all as specified and as directed.
S&F 150 mm long Stainless steel tower bolts and fixed complete all as specified and as directed.
S&F Stainless steel fabricated type handle 250mm long complete all as specified and as directed.
S&F Stainless steel sliding door bolt 300mm long with hasp & staple (bolt type) and fixing clips of SS sheet castand fixing bolts and sliding bolts of extruded section complete all as specified and as directed.
Supply and Fix 7.5mm thick Aluminum grill of specification having aperture length wise 80mm and width wise 66mm with F channel section complete all as specified and as directed.
Supply and Fix sheet glass 4.0mm thick and glazing with oil putty or with spring clips in metal surrounds or with beads fixed with metal panel pins or brass screws in squares complete all as specified exc 0.5sqm each pane complete all as specified and as directed.
Supply and Fix powder coated (minimum thickness of powder coating not less than 50 micron) anodised aluminium frame for doors, windows ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed.
S&F powder coated (minimum thickness of powder coating not less than 50 micron) anodised aluminium door shutters, aluminium section weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges anodised alumnium snap beading, screws etc. complete all as specified including Tower bolts, door stopper and hydraulic door closure and one No Mortice lock.
S&F powder coated (minimum thickness of powder coating not less than 50 micron) anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 No.) hinge type B-21 100mm long (2 No.) suitable handle (1 No.) complete all as specified and as directed.
M&L for Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed, complete all as specified and as directed.
M&L for PCC 1:3:6 type C1 as in fixing of holdfast cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets etc complete all as specified and as directed.
S&F floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor, overall length of cover plate 140mm complete all as specified and as directed.
M&L for fixing 5 mm thick anodised aluminium composite panel fixed in aluminium frame including necessary rubber beading, jointing cleats complete all necessary items to fix with frame complete all as specified and as directed.
S&F mild steel works as in bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required hooks (stay), heavy, for large gates hook and pintle hinges large hasps and staples, chains, hand made sliding bolts, clamps, hold fasts, wall ties, hooks for hanging fan, plain angle cleats for securing purlins to wood trusses or rafters, knee piece inserts, two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and as directed.
S&F solid PVC wall lining consisting of 5mm thick single side prelam colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specification and drawing complete all as specified and as directed.
S&F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC frame as per specification and drawing complete all as specified and as directed.
M&L for stainless steel (Grade 304) railing/tubular posts made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the tubes with toughned glass etc including necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab etc with suitable arrangement complete as per direction and approval of GE as well complete all as specified and as directed. Note: Design and pattern shall be approved by Engr-in-charge /GE at the time of execution of work.
S&F 10mm thick Toughned glass as in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holes required complete all as specified and as directed. Note: Design and pattern shall be approved by Engr-in-charge /GE at the time of execution of work.
M&L for providing and laying 60 mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern by GE/Engr-in-Charge as in footpath, parks, lawns, drive ways or light traffic parking etc of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern as approve by GE/Engr-in-Charge over and including 50 mm thick compacted bed of fine sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, complete all as specified and directed by GE/Engr-in-Charge
S&F for pre-painted galvalume aluminum zinc coating GI based corrugated/crimped steel sheet 0.50mm thick of any colours having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
S&F for rolled mild steel sections as in trusses, purlins, fastening, heavy bracket framing (tee, angle, channel, tube or flat section) including distance pieces, cleats etc and included all cutting, welding necessary fittings such as nut bolt, plate etc complete all as specified and as directed.
ELETRIFICATION M&L for point wiring complete with 1.5 Sqmm single core PVC insulated unsheathed FR-LS cable 1100 volts grade (ISI marked) with multistranded copper conductor with proper colour coding drawn through and including non-metallic rigid PVC medium grade conduit and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc including provision of 1.5 Sqmm PVC insulated multistranded unsheated copper conductor cable FR-LS (ISI markd) with proper colour coding as earth continuity conductor connected to common earth dolly , modular sheet steel sunken terminal box of appropriate size suitable for modular switch/ fittings concealed in walls, with modular back plate, top cover fixed flush to wall for housing switches, socket outlets, fan regulators etc duly earthed including cutting chases of existing wall for conduits and sinking for boxes and making good to the disturbed surface of wall/floor and matching with existing specifications. Connections of cable with MCB's or bus bar shall be done through proper size copper/brass thimbles. all as specified and as directed for the following :-
One light point controlled by one way switch 5/6 amps complete all as specified and as directed.
One ceiling fan/Exhaust fan point controlled by one way switch 5/6 amps complete all as specified and as directed.
One socket out let 5/6 amps point on the same board complete all as specified and as directed.
One socket out let 5/6 amps point on the independent board complete all as specified and as directed.
All as per item No 83 above but wiring with 2.5 sq mm single core multistranded copper conductor for one socket out let 15/16 amps point on the independent board complete all as specified and as directed.
M&L for point wiring complete for one power point for one metal plug & socket for AC or one socket for geyser point on independent board with 4.0 Sqmm multistranded copper conductor single core PVC insulated unsheathed FR-LS cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including non-metallic rigid PVC medium grade conduit not less that 20mm dia and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc including provision of 4.0 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LS (ISI marked) as earth continuity conductor connected to common earth dolly, including cutting chases of existing wall for conduits and fixing for Metal Plug and socket boxes and making good to the disturbed surface of wall/floor and matching with existing specifications. Connections of cable with MCBs or bus bar shall be done through proper size copper/brass thimbles complete all as specified and as directed.
S&F of Modular switch, single pole, one way, 6 Amp, 1 Module, 230 volt, ISI marked complete all as specified and as directed.
S&F of Modular switch, single pole, one way, 16 Amp, 1 Module, 230 volt, ISI marked complete all as specified and as directed.
S&F of Modular shuttered Socket outlet 5 Pin, 6 Amp, 2 Module, 230 volts, ISI marked complete all as specified and as directed.
S&F of Modular shuttered Socket outlet 6 Pin, 6/16 Amp, 2 Module, 230 volts, (ISI marked) complete all as specified and as directed.
S&F of Modular bell push, one way, 6 Amp, 1 Module, 230 volt, ISI marked complete all as specified and as directed.
S&F of stepped type modular electronic fan regulator 120 watt 2 module suitable for 1200/1400 mm sweep energy saving fans, ISI marked complete all as specified and directed.
S&F Call bell Ding dong, 230 Volt single phase complete all as specified and as directed.
S&F lamp holder, insulated body, with back plate suitable for batten/angle fittings complete all as specified and as directed.
S&F LED white glass Lamp 1x9 Watt 230V Base-22 complete all as specified and as directed.
S&F in ceiling rose, Bakelite, surface type, 220/240 volts, three terminals complete all as specified and as directed.
S&F IP 20, class I, LED light 1X20 W (or nearest next higher wattage) (4feet), 5700K, wall/ surface mounted, integrated type with aluminum housing and decorative and caps with integrated high efficiency electronic driver and surge suppressor of 2KV or more, luminaries efficiency > 95 lumens/watt, power factor > 0.90, operating range - 140 to 270 V, 50 Hz fixed with 02 Nose of PVC round/ square blocks, screws etc complete with all accessories internally prewired and connecting up complete all as specified and as directed. Make - Havells, Cat Part No - EDURALINEARNEOBS20WLED865SPCWH or techno commercially equivalent make as listed in List of Makes as approved by the GE.
S&F of decorative wall light fixture made up of polycarbonate suitable for 15 Watt LED retrofit of type B-22 base, IP66 grade, with and including 15 watt LED (or nearest next higher wattage) lamp and connecting up with and including PVC insulated 3 core of size 0.75 Sam copper conductor to terminal block of light fitting complete all as specified. Make - Havells, CAT No - LHFOECE1TZ1B014 or techno commercially equivalent make as listed in List of Makes as approved by the GE.
S&F Recess round shape LED ceiling light 12 Watt fitting (6'' outer dia) for Armstrong/ grid ceiling, white powder coated CRCA housing complete with full window acrylic diffuser & electronic driver, high brightness SMD LEDs etc complete with all accessories internally prewired and necessary mounting arrangements, including necessary connection complete all as specified and as directed.
S&F Energy saving new generation environmental friendly long life versatile pressure die cast aluminum IP 66 security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 25 watts with pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting and GI pipe bracket made out of GI pipe medium grade 32 mm dia 1.5 mtr long bend to required shape complete all as specified and as directed.
M&L for sub main wiring with 2 run of 6.00 sqmm (nominal cross-sectional area) PVC insulated unsheathed single core FRLS cable of working voltage 1100 volts grade with stranded copper conductor including one run of 6.00 Sqmm (nominal cross sectional area) PVC insulated unsheathed cable with stranded copper conductor as continuous earth wire connected to common earth dolly drawn in 25 mm dia PVC rigid non- metallic concealed conduit complete all as specified and as directed. Note: Two runs of submain wiring cable alongwith one run of earth wire with and including 25 mm dia PVC conduit pipe shall be measured as one unit length.
S&F MCB distribution boards (DBs) with sheet metal enclosure, double door, IP 43 protection, 240 Volts, 8 way, single pole and neutral, with 200 Amps rated copper bus bar (as per OEM), neutral link, earth link earthing studs, suitable for fixing MCBs, without MCBs fixed flush to wall/other surface complete all as specified and as directed.
S&F MCB, Single pole & neutral, 32 to 63 amps, 240 volts, ‘C’ curve, 10KA complete all as specified and as directed.
S&F MCB, Single pole, 5 to 32 amps, 240 volts, ‘C’ curve, 10 KA complete all as specified and as directed.
Material and labour for earthing complete with galvanized steel plate electrodes of size600x600x6mm thick buried directly in ground with earth pit not less than 2.25 meter deep below normal ground level with top edge of plate not less than 1.5 meter below normal ground level connected to galvanised iron strip 25 x 4 mm earth lead by means of nuts, bolts, checknuts and washers including 15 mm bore galvanized iron pipe, medium grade for protection of earth lead upto the length of 7.5 meter towards test terminal and 20 mm bore galvanized iron pipe, medium grade for watering, and providing of charcoal and common salt in alternate layers, including necessary earth work in any type of soil and including PCC pit in PCC 1:2:4 with provision of wire mesh and funnel, complete all as shown in electrical plate No 5 of SSR Part- I including testing on completion all as directed and as specified.
Supply & fix Ceiling fans with all accessories 230 V,1200 mm sweep BEE 5 star rated, conforming to IS 374:1979 complete with pre wired with 3 core cable completion all as directed and as specified.
S&F wall fan 400 mm sweep, energy efficient, AC single phase 240 volts, 50Hz, Ai and connecting up complete with provision of 3 core flexible multistranded copper conductor of size 0.75 Sqmm from ceiling rose to fan complete all as specified and as directed.
Supply and lay dry river sand filling for under ground cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying complete all as specified and as directed.
Supply and laying sub class B bricks of old size for protection of UG cable with width equal to length of bricks as mechanical protection laid dry and flat complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 Sqmm 4 core complete all as per specified and directed.
M&L for horizontal boring across the existing road without disturbing the road surface for inserting GI pipe complete all as specified and as directed. Notes : (a) Removal of surplus soil shall be deemed to be include in the unit Rate. (b) GI pipe will be measured and paid separately under relevant item of Sch 'A'.
M&L for 50 mm bore steel tubing light grade ISI marked for protection of cable including necessary joints complete all as specified and as directed.
Supply and lay pipe galvanized, “Medium grade” including fittings 20 mm fixed complete to walls and ceiling or laid in floor complete all as specified and as directed.
Supply and lay pipe galvanized, “Medium grade” including fittings 25 mm fixed complete to walls and ceiling or laid on flor all as specified and as directed.
Supply and fix Gun metal globe Gate Valves with iron wheel head of 20 mm dia bore complete with all accessories complete all as specified and as directed.
Supply and fix Gun metal, globe Gate Valves with iron wheel head of 25 mm dia bore complete with all accessories complete all as specified and as directed.
N K Construction (BID ID -3111981)
M/s Om Prakash Agarwala (BID ID -3112387)
M/S DELTA ENGINEERS & CO (BID ID -3112186)
R.MANJIT& CO (BID ID -3110483)
S. G. CONSTRUCTION (BID ID -3113016)
M/S SINHA ENTERPRISE (BID ID -3112469)
ANUP ENGINEERING WORKS (BID ID -3111455)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .