Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.7 LAccepted-AOC 137 D THEJAS BURNASHERRY KANNUR KERALA 670013 | KANNUR | KANNUR | KERALA | 670013 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹24.0 L+₹87,007.50 (3.77%)Rejected-AOC PAYYOOR KOTTARATHI HOUSE POST AMAYUR KOPPAM PALAKKAD KERALA 679303 | PALAKKAD | KERALA | 679303 | L2 | Rejected-AOC Not being lowest | |
| 3 | L3₹24.7 L+₹1.6 L (6.89%)Rejected-AOC 606 80 FEET ROAD 7TH BLOCK 2ND PHASE BANASHANKARI 3RD STAGE BANGALORE 560 085 | BENGALURU URBAN | KARNATAKA | 560085 | L3 | Rejected-AOC Not being lowest | |
| 4 | L4₹28.0 L+₹4.9 L (21.3%)Rejected-AOC | L4 | Rejected-AOC Not being lowest |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
25 Apr 2025, 6:00 pmClosed
GE MAINT EZHIMALA
GARRISON ENGINEER (MAINT) MILITARY ENGINEER SERVICES INDIAN NAVAL ACADEMY POST KANNUR DIST KERALA 670 310
AS PER BOQ AND TENDER DOCUMENTS
2025_MES_702872_1
GE MAINT EZHIMALA 8735
Open Tender
Civil Works
Item Rate
330 days
EZHIMALA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE MAINT EZHIMALA
₹70,000
Yes
3 Jun 2025
28 Mar 2025
1 May 2025
28 Mar 2025
25 Apr 2025
11 Apr 2025
28 Mar 2025 - 4 Apr 2025
Amount
Notes for all items of BOQ:- a) Contractor has to provide one electrician and one helper each day including Sunday and holidays to collect complaints from Complaint cell/ JE E/m/ AGE E/m and rectify the same within 48hrs(two days) otherwise recovery will be done Rs. 1000 per complaint per day delay. b) Contractor has to maintain complaint slip/ register and record day to day complaints and after rectification has to get signature of user/JE E/m on daily basis. c) Contractor has to provide necessary safety equipments and will be fully responsible for any incidents occuring on site. d) Contractor has to visit the site before quoting the tender. e) contractor has to provide proper ladder arrangement to work on any height street light pole. f) Necessary fixtures needed to fix the street light fitting in pole of any dia has to be included in the quoted rate. g) LM79 report by NABL accredited lab has to be submitted. h) If contractor failed to provide Electrician to attend complaint or absent to attend complaints then recovery will be done Rs 2000 per day.
M&L for taking down the unserviceable LT UG cable of size of 6Sqmm to16 sqmm 4 core including removing electrical connection and keeping side serviceable cable include removing cable protection cover etc complete all as specified and as directed.
Exacavation in trenches not exceeding 1.5 mtr in width and depth and getting out in hard/dense soil complete all as specified and as directed by Engr-in-charge. Notes:- a) For all items involving excavation work contractor has to obtain prior approval from station HQ to avoid loss of other co existing utility services, in case of damage to any property he would be liable for its rectification. b)The excavation has to be done manually only.
Returning and filling in including levelling, watering and well ramming into layers not exceeding 25 cm in hard/dense soil complete all as specified and directed by Engr-in-charge.
Removal of excavated soil to a distance not exceeding 50 mtrs and depositing at a level not exceeding 1.5 mtr from starting point complete all as specified and directed by Engr-in-charge.
Supply and spreading riddled earth for cushioning and covering of the UG cable in trenches complete all as specified and as directed. Note:- Punned thickness shall be measured for payment purpose.
Supply and lay PCC un reinforced LT cable cover of size 250 mmx 150mmx40mm , class LV type I flat for cable protection complete all as specified and directed.
Relaying of PCC un reinforced LTcable cover of size 250mmx150 mmx40mm, item obtained from ser No 02 above complete all as specified and directed by Engr in charge.
Relaying cable XLPE insulated heavy duty galvanised steel strip armoured LT 1100 volt grade of any size with aluminium conductors multistranded confirming to IS laid in trenches/pipes/ wall complete all as specified and as directed.
Supply and laying LT cable in trench/fixing to walls/pipe/pole with proper saddles, lugs, glands XLPE insulated heavy duly galvanised steel strip armoured LT1100 volt grade with aluminium conductors of size 16 sqmm 4 core complete all as specified and directed.
All as per item No.10 above but size of 10 sqmm 4.0 core complete all as specified and directed.
Supply and laying LT cable in trench/fixing to walls/pipe/pole with proper saddles, lugs, glands XLPE insulated armoured cable with copper conductors of size 2.5 Sqmm 3 core complete all as specified and directed.
M&L for mass filling in foundation/coping/wall with PCC 1:3:6 using 20 mm graded aggregate type C1 as site requirement complete all as specified and directed by Engr in charge.
M&L for dismantling/removal of existing pole of Post top lantern of any type from it's position/foundation after necessary exavation and earth work and refixing on site complete all as specified and as directed.
Cutting the existing road/hard standing made of concrete or premix carpet, WBM, soling and moorum filling including excavating for laying the cable/pipe, width 0.5 Mtr and depth 0.7 Mtr all as directed and making good the road/hard using pre mix bituminous as required at site to match with the existing surface complete all as specified and as directed. Note:- Before using the hand drilling/ breaker machine diamond cutter will be used all as directed by Engr-in-charge.
Supply and fix in replacement of GI tubing light grade 50 mm nominal dia in trench/road/pole for cable protection complete all as specified and directed.
All as per item no.16 above but size of 40mm nominal dia complete all as specified and as directed.
Supply and fix in replacement of copper cable flexible 1.5 Sqmm 3 core 230 Volts complete all as specified and as directed by Engr-in-charge.
S&F in replacement of digital time switch programmable type, two module complete all as specified and directed by Engr in charge. Make:- Model No: 67DDT0 of L&T or equivalent in Havells/ Schneider/Seimens.
S&F in replacement of contactor four pole 415 volt 63 Amp capacity complete all as specified and directed by Engr in charge. Make:- Type: MCX 12 of L&T or equivalent in Havells/ Schneider/ Seimens.
Supply and fix in replacement of post top lantern having opal acrylic and spun aluminium reflector with high power LEDs as light source having 40 watt capacity , 440V, 50Hz, IP 65 rated ,with 5Kv SPD inclluded and PF above 0.95 suitable for pole dia upto 60 mm complete all as specified and directed by Engr in charge. Make:- Cat No. BGCTNP 40W LED WH/WW of BAJAJ or equivalent in Crompton/ Havells/Philips. Note:- LM79 report by NABL accredited lab has to be submitted.
Supply and fix in replacement bollard light fitting tulip/robust type LED bollard light fitting made out of die cast aluminium with soft 360 light ouput and 9/10W capacity, CCT 3000k/5700k with IP 65 proctection complete all as specified and as directed by Engr-in-charge. Make:- Cat part no.LBLTW-10-WW of Make Crompton or equivalent in Havells/ Bajaj/Philips.
Supply and fix in replacement of old unserviceable street light fitting with LED street light fittings on poles of any height upto 11m using proper ladder arrangements. LED street light luminaire must have following specifications: minimum 60 watts capacity ,240V, 50Hz made out of pressure die cast hosuing, IP 66 rating, efficacy above 120 Lm/W, 10kv surge protection a 5700K complete all as specified and as directed. Make:- Cat Part No.Enxt P 72L WH CR PC SD of Bajaj or equivalent in Crompton/ Havells/Philips.
Supply and fix in replacement of old unserviceable street light fitting with LED street light fittings on poles of any height upto 11m using proper ladder arrangements. LED street light luminaire must have following specifications: minimum 90 watts capacity ,240V, 50Hz made out of pressure die cast hosuing, IP 66 rating, efficacy above 120 Lm/W, 10kv surge protection a 5700K complete all as specified and as directed. Make:- Cat Part No.Zela P 108L WH PO TG SD of Bajaj or equivalent in Crompton/ Havells/Philips.
Supply and fix in replacement of post top lantern, made of spun aluminium die cast material,energy saving,enviormental friendly, with high power LEDs as light source of 20 watt capacity warm white/ CDL , IP 65 rated protection suitable for pole dia of upto 60 mm complete all as specified and directed by Engr in charge. Make:- Cat No: BGCTNP 20W Led WH of Bajaj or equivalent in Crompton/ Havells/ Philips.
S&F in replacement of die cast aluminium IP 66 rated 120 W LED flood light luminaire on poles / buildings of any height using proper ladder arrangements with system efficacy above 120Lm/W and with 10KV surge protection device complete all as specified and directed by Engr in charge. Make:- Cat Part No: Praze F144L WH NB a5 TG SD of Bajaj or equivalent in Crompton/ Havells/Philips.
S&F in replacement die cast aluminium IP 66 rated 80 W LED flood light luminaire on poles/ buildings of any height using proper ladder arrangements with system efficacy above 120Lm/W and with 10KV surge protection device complete all as specified and directed by Engr in charge. Make:- Cat Part No: Praze F96L WH NB a5 TG SD of Bajaj or equivalent in Crompton/ Havells/Philips.
Supply and fix in replacement of bracket made out of GI pipe medium grade, 50 mm dia, 90 cm long for fixing street light with and including clamps, nuts, bolts, washer complete accessories and applying two coats of oil painting over one coat of red oxide zinc chrome primer complete all as specified and directed by Engineer-in-Charge.
M&L for taking down the defective security light fittings /street light fittings of any type from 11/10/8.5 Mtr Swan neck type pole and refixing in same position after carrying out necessary repair work/replacement of burn out parts and cleaning the fittings completely including replacement of minor burnout spares such as connectors/clamps/wire etc complete all as specified and directed by Engr-in-charge.
Supply and fix in replacement weather proof street light junction boxes made out of thermo plastic consisting of 4 nos of connectors of capacity 40 amp 415v with proper closing arrangement, elmax connector for neutral link including pole mounting clamp with nut bolts. The box should have two cable entry and should be able two accommodate two cables of size 25Sqmm with proper space between each phases complete all as specifed and directed by Engineer-in-Charge.
Supply and fix in replacement of LED bulb B22 Type 09 Watts in Gardern lights/ Dome lights after removing the outer cover and refixing the same after replacement complete all as specifed and directed by Engineer-in-Charge.
M&L for scrapping out faded / rusted old paint from street light pole of 9m height using wire brush, emery paper and preparing surface for painting applying one coat of aluminium paint on poles including cross arms, bolts and nuts, anti climbing device etc and written existing pole number with black paint over a yellow base and painting of coping/base using white cement paint complete all as specifed and directed by Engineer-in-Charge.
M&L for scrapping out faded / rusted old paint from Decorative PTL double arm/single arm pole of height upto 3.5m using wire brush, emery paper and preparing surface for painting applying one coat of aluminium paint on poles including cross arms, bolts and nuts etc and writtem existing pole number with black paint over a yellow base and painting of coping/base using white cement paint complete all as specifed and directed by Engineer-in-Charge.
M&L for repairing of garden lights by removing defective garden light fitting and refixing the same after doing minor repairs such as cleaning, tightening loose connections, re aligning and replacing burnout lamp holder /connectors complete all as specified and directed by Engr-in-charge.
pk janardhanan (BID ID -3283975)
LUCKY ENTERPRISES (BID ID -3283921)
TAMS ASSOCIATES (BID ID -3284183)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .