Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.5 LAccepted-AOC | L1 | Accepted-AOC Lowest Tenderer | |
| 2 | L2₹32.0 L+₹48,676.48 (1.54%)Rejected-Finance | L2 | Rejected-Finance other than lowest | |
| 3 | L3₹35.3 L+₹3.8 L (12.0%)Rejected-Finance A 401 NAV VRUNDAVAN CHS SYNDICATE MURBAD ROAD KALYAN 421301 | KALYAN | THANE | MAHARASHTRA | 421301 | L3 | Rejected-Finance other than lowest |
Tender Value
Refer Docs
EMD Value
₹68,000
Closing Date
13 Dec 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE MAMUN
HQ CWE MAMUN PATHANKOT-145001
REPAIR/ MAINTENANCE/ IMPROVEMENT OF HT SYSTEM AND CONNECTED ALLIED WORKS UNDER AOR OF GE SAMBA
2021_MES_487300_1
CWE/M-13/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE Samba
Class D Category b ii
5 documents required · 5 mandatory
₹500
GE SAMBA
₹68,000
11 Jan 2022
9 Nov 2021
15 Dec 2021
9 Nov 2021
13 Dec 2021
29 Nov 2021
60 days
Amount
Excavation in trenches n. exc. 1.5 mtr wide and n. exc. 1.5 mtr in depth for foundation of pole and laying of UG cable and getting out in any type of soil complete all as specified and directed.
All as per srl item No.1 above but depth exceeding 1.5 Mtr and not exceeding 3 mtr complete all as specified and directed.
Removing excavated material (soil) to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as spd and directed.
Returning filling in, including spreading, watering and well ramming in layers not exceeding 25 cm thick in any type soil complete all as spd and directed.
M & L for Sand cushioning for under ground cable upto 8 cm before laying the cable and 15 cm after laying and stretching the cable complete all as spd and directed.
Material and labour for sub class 'B' bricks well burnt old size laid dry flat for protection of cable complete all as spd and directed.
Material and labour for Plain cement concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in foundation of poles including necessary form work for rough finished surface complete all as specified and as directed.
Material and labour for Plain cement concrete 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) as in coping to poles including necessary form works for rough finished surface complete all as specified and as directed.
Supply, laying & testing cable XLPE insulated, screened PVC bedded galvanised steel strip armoured HT electric power cable (heavy duty) 11000 volts grade with aluminum conductor 6.35 KV (UE)/11 KV (E) grade, cross sectional area 120 Sqmm 3 core as per IS-7098 suitable for earth system laid in trenches of complete all as specified and as directed.
Supply, laying & testing cable XLPE insulated, screened PVC bedded galvanised steel strip armoured HT electric power cable (heavy duty) 11000 volts grade with aluminum conductor 6.35 KV (UE)/11 KV (E) grade, cross sectional area 95 Sqmm 3 core as per IS-7098 suitable for earth system laid in trenches complete all as specified and as directed.
Supply, fixing, commissioning and testing of Aerial bunched XPLE insulated with aluminium conductor stranded 11000 volt grade 3 single core cross sectional area 95 sqmm and one 70 sqmm aluminium conductor cable including anchor clamps made out of MS strip 32 x 6mm complete with clamps and nuts and bolts for cable on poles incl dismantling of existing over head conductor complete all as specified and directed. Note: Old dismantled ACSR conductor of any type shall be property of contractor.
M & L in repairs Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination Heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE HT armoured aluminium conductor cable of size 95 sqmm complete all as specified and directed, Make all as mentioned in Annexure-1
M & L in repairs Cable end jointing kit for 11 KV (earthed) grade cable for out door type termination heat shrinkable type joint complete with all jointing material and accessories suitable for 3 core XLPE HT armoured aluminium conductor cable of size 120 to 185 sq mm complete , all as specified and directed, Make all as mentioned in Annexure-1.
M & L in repairs Cable end jointing kit for 11 KV (earthed) grade cable for out door type termination heat shrinkable type joint complete with all jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 sq mm to 300 sqmm complete , all as specified and directed, Make all as mentioned in Annexure-1
Taking out the unserviceable/ burnt jointing kit and supply and fix new cable jointing kit for 11 KV (Earthed) grade cable for out door termination heat shrink type complete with jointing material and accessories suitable for single core ABC aluminium conductor cable of size 95 sqmm complete all as specified and directed.
Taking down old unserviceable lightning arresters and Supply and fixing for lightning arresters expulsion type complete with all fittings transmisson class,discharge capacity 65 kilo amps suitable for 11000 volts conforming to IS complete all as specified and directed. Make - Pactil/OBLUM/CROMPTON GREAVES/ BHEL.
Taking out the unserviceable gang operated device after disconnecting the electric HT supply and Supply and fixing air break switch gang operated (GOD) triple pole with drop out fuses mechanically operated, mounted on insulators (15 insulators) & steel frame with operating mechanism & operating rod of GI pipe 25mm medium grade with necessary clamps to be operated from ground level 11 KV grade working pressures and current upto 400 amps etc complete, all as specified and directed. Make:PACTIL/OBLUM/ABB/BHEL.
M & L in replcement of structural steel work conforming to grade Fe-410S as in cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections, including , nuts, bolts, washers, welding , bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of one coat of zink chrome primer and two coats of aluminium paint for 11KV insulation complete all as specified and directed.
M&L anti climbing device, spikes type fabricated out of MS bars (round/square/flat) including nuts,bolts, washers and welding in two halves made to shape to suit the cross section of the pole including dismantling old one complete all as specified and directed.
Taking down existing unserviceable / old ACSR conductor from over head lines complete all as spd and directed.
Supply and fixing aluminum conductor steel reinforced (ACSR) for HT lines on PCC/steel tubular poles, streching without kinks and bends including aluminum binding wires of size Ferret to Dog as per load complete all as spd and directed. Make all as mentioned in Annexure-1
S & F stay assembly complete comprising of 16mm dia, 40cm long stay bow rod 16mm dia x 1.8 Mtr long galvanised stay rod threaded and with nuts including 300mm x 300mm x 6mm thick plate GI, stay wire, stay clamps and necessary clamps for any type of pole etc as shown on plate No. 1 on page 495 of SSR Part-I, 2009 complete including taking down U/S stay assembly all as specified and directed ( Note : Loop type insulator, excavation and concrete work shall be measured and paid separately).
Dismantling insulators any type and size complete all as specified and directed.
S & F in replacement loop type insulator with complete fitting porcelain, vitreous white or brown large size with over all dismensions 90x140mm , clearance of hole 25.5mm all as specified and directed.
M&L pin type insulator vitreous, white, brown, or green insulator includig one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut 150 mm height, 150 mm dia for 11000 volts grade complete all as specified and directed.
S&F disc type insulator, porcelain, vitreous 145 mm high and 255 mm dia ball and socket type white, brown or green, single disc assembly for tension with tension clamps for conductors, working pressure 11000 Volts complete all as specified and directed.
S & F in replacement galvanised steel stranded stay wire size 7/3.15mm for stay assembly complete all as specified and directed.
Restretching of ACSR conductor of any size of over head lines LT/HT on poles including binding with insulators, jointing jumpers etc including connections of incoming and out going cables complete all as specified and directed. Note: (1) ACSR conductor Required for winding etc is deemed included in quoted rates. (2) The distance between two poles shall be considered as one Span for measurement purpose.
Trimming up of tree branches upto 3 mtr all around HT overhead lines, removing cut branches from site complete all as directed. Note :- (i) The overhead lines will be kept clear from all trees by trimming of tree branches with 3 mtr all around the line. Necessary permission will be obtained from department by contractor one day prior to trimming in particular area and shut down of that area will be arranged by department accordingly. The trimming work shall be commenced once it is permitted by AGE.(ii) only effective length i.e length where tree branches are touching HT line or neaby HT line shall only be measured & paid under this item. No claim whatsoever shall be entertained by the deptt at later stage. (iii) Fortnightly inspection of lines will be made jointly by contractor or his authorised rep and rep of Engr-in-Charge and outcome whether lines are free from tree branches or not kept on record for payment. (iv) The OH line will be maintained for whole period of contract and full payment will be made with Final Bill only. The payment for the period for which line not maintained will be deducted proportionately based on fortnightly inspection carried out as detailed above.
Taking out broken old poles of any type complete all as specified and directed.
Supply & fixing Prestreesed concrete pole 11 Mtr long 152x152 mm at top and 152x260 mm at bottom class-9 errecting in truely vertical position complete all as specified. Note :(Excavation and PCC shall be measured and paid for separately under relevent item of this BOQ).
Material and labour for erection of steel tubular swaged pole 11 mtr long with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP 55, including painting with anti corrosive paint internally complete and externally up to planting depth, alternative green & white strips of 30 cm height upto 1.5 mtr above ground level complete all specified and directed. Note: Excavation and earth work, GI pipe, clamps shall be measured and paid for separately under respective items.)
M&L for earthing complete with galvanized steel earth plate electrode 600x600x6mm thickness not less than 6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below the normal ground level ) with top edge of plate not less than 1.5 mtr below the normal ground level connected to galvanized iron strip 32X6mm by means of nuts bolts,washers,check nuts of GI steel all as shown in electric plate no 3 of SSR -2009 Part I, all as specified and indicated complete and including charcoal dust common salt in alternative layer of 15cm etc and GI protection pipe medium grade 40mm and GI watering pipe 20mm light grade with funnel and wire mesh ,40mm thick pre-cast RCC N-15 (nominal mix) cover reinforced with XPM weight not less than 4 kg /sqm with suitable handle of 6mm dia MS bar and angle iron 40x40x3mm frame for cover ,PCC M-15 (nominal Mix) pit,excavation and earth work in any type of soil and connected all as specified and as directed. Notes: 1. Earth lead & protection pipes length upto & including 7.50 metre is deemed included in unit rate quoted by the contractor. 2. Earth filling shall be done by vegitable soil. 3. Soil shall be free from stone, boulders, aggregate, gravels .
M & L earthing complete with galvanised steel earth plate electrode , 600x600x6mm thick burried directly in the ground (earth pit not less than 2.25 mtr deep below ground level)with top edge of the plate not less than 1.5mtr below ground level connected to galvanised iron wire 4mm dia as earth lead by means of bolts, nuts and washers of GI up to test point , GI tubing 15mm bore medium grade protection pipe , GI watering pipe 20mm bore light grade with funnel and wire mesh , charcoal , and common salt in alternative layer of 15cm precast PCC 1:2:4 (Nominal mix ) cover with suitable steel handle , and angle iron 40x40x3mm frame for pit cover , PCC 1:2:4 pit including earth work in any type of soil , removal of surplus soil to a distance n.exc 50mtr and connecting , testing on completion all as shown on electric plate No 03 of SSR -2009 Part I complete all as directed. Notes: 1. Earth lead & protection pipes length upto & including 7.50 metre is deemed included in unit rate quoted by the contractor. 2. Earth filling shall be done by vegitable soil. 3. Soil shall be free from stone, boulders, aggregate, gravels .
Supply and fixing aluminium strip 25 x 3.15 mm with saddles and fixing screws etc for roof and ground conductors and down conductors above ground complete all as specified and directed.
M & L for GI pipe in replacement ( Light grade ) for protection of HT cable fixed to walls/ poles/road crossing including suitable size clamps complete of size 80mm bore, all as specified and directed.
Taking down the old/unserviceable Ammeter from the HT panel and Supply and fixing new digital ammeter programmable suitable for 11 KV VCB range having 1A /5A ratio suitable flush pattern square type 96mm x 96mm with adopter including wiring, make: Secure /Rishosn/AE complete all as specified and directed.
Taking down the old/unserviceable and Supply and fixing new digital voltmeter programmable 96mm x 96mm suitable for 11KV HT VCB panel axiliery voltage 0-500 volt, as per installed panel make and model or equivalent complete all as specified and directed.
M & L for construction of platform of size 3000 x 2500 x 1200 mm for transformer with PCC (1:4:8) in foundation and PCC 1:2:4 type B1, 100 mm thickness at top portion of platform , brick work with cement mortar (1:4) and complete plaster work of 15 mm thick to exposed surface in CM (1:4) including necessary MS work ( i.e. MS jali/fencing/MS angle ) on the top of platform around transformer up to height 90 cm and one coat of white wash on plastered surface complete all as specified and shown on drawing No CEPZ/C-TD/002/13 Sheet 2/5.
M&L for Rendering 15mm thick in two layers (base layer 10mm in CM 1:6 & finishing layer 5mm thick in CM 1:4) using liquid water proofing compound (in 2nd layer only) on brick work or concrete surfaces of wall surfaces finished even and smooth using extra complete all as specified & directed. (Note : WPC shall be measured and paid separately)
Supply only Polymer liquid water proofing compound of make ilite/Bauchemic/Fosrock complete all as specified and directed.
S&F chain link fencing mild steel galvanised with 100 mm size of mesh, 10 gauge including line wire secured and fitted to angle/RCC poles complete all as specified and directed. Note:- PCC/angle shall be measured and paid separately.
Material and labour for spreading of graded course aggregate 40mm nominal size (thickness min 15cm) to be spread over sand 10cm thick incl surface excavation and removal of complete vegetation and levelling and brick work using old size class B complete all as directed by Engineer-in-Charge.
Material and labour for painting of HT steel pole of any type including cross arms from top to bottom with two coat of synthetic aluminium enamel paint including 5 Nos 30cm wide strip of black and yellow paint with two coats of synthetic enamel paint alongwith writing word HT and pole no complete all as specified and directed by the Engineer-in-Charge. (Note: T&P & ladder for painting will be deemed included in quoted rate).
Material and labour for painting of HT PCC pole of any size upto 1.5 metre height from bottom with two coat of cement base paint including 5 Nos 30cm wide strip of black and yellow paint with two coats of cement base paint alongwith writing word "HT" and pole No including panting of cross arms with two coats of aluminium paint complete all as specified and directed by the Engineer-in-Charge. (Note: T&P and ladder for painting will be deemed included in the quoted rate)
S&F danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps,bolts, nuts of approved size for HT 25x20 cm size including dismantling old onecomplete all as specified and directed.
Repair /servicing /Calliberation to HT panel of make : Crompton having vacuum circuit breaker 11 KV rating of capacity 250 MVA and current rating up to 630 Amp by replacing defective/wornout part, adjustment of gaps for smooth operation all as detailed below:- (a) Cleaning of VCB with air blower and removing dust particals (b) Cleaning of insulating places of VCB by using CTC/CRC/Thinner as required and recommended. (c) Checking the arcing contact gap of vaccum intrupter if gap exceeds the permissible limis, readjust as recommended (d) Cleaning the main contacts to remove carbon or any other unwanted particals if visible. (e) Dismantling and cleaning the insulated surfaces and arc barrier with CTC and CRC. (f) Checking/ repair replacement of all electrical/ manual operation of panel including measuring IR values. (g) Checking of all nuts/ bolts. springs, levers, latches, connectors etc. and adjustments as required and recommended. (h) Recording IR values of CTs and PTs (j) Cleaning of bus bar spout. (k) Cleaning of all moving parts for proper functioning of VCB and adjustment as per manufacturer recommendations. Note: (i) Service will be carried out through Service Engineer of Manufacturer only. The service engineer so hired should be the manufacturer employee only. No employee of authorized dealer shall be hired for servicing of VCB. (ii) The cost of minor spare parts i.e nut and bolts, springs, grommets, dust cover, ring of isolator contacts, clips, pin for release prop. "Y" Phase shround, over ride stop pin etc essentially required to make the panel serviceable shall deemed to be included in the unit rate by contractor.
Repair /servicing /Calliberation to HT panel of make : ABB having vacuum circuit breaker 11 KV rating of capacity 250 MVA and current rating up to 630 Amp by replacing defective/wornout part, adjustment of gaps for smooth operation all as detailed below:- (a) Cleaning of VCB with air blower and removing dust particals (b) Cleaning of insulating places of VCB by using CTC/CRC/Thinner as required and recommended. (c) Checking the arcing contact gap of vaccum intrupter if gap exceeds the permissible limis, readjust as recommended (d) Cleaning the main contacts to remove carbon or any other unwanted particals if visible. (e) Dismantling and cleaning the insulated surfaces and arc barrier with CTC and CRC. (f) Checking/ repair replacement of all electrical/ manual operation of panel including measuring IR values. (g) Checking of all nuts/ bolts. springs, levers, latches, connectors etc. and adjustments as required and recommended. (h) Recording IR values of CTs and PTs (j) Cleaning of bus bar spout. (k) Cleaning of all moving parts for proper functioning of VCB and adjustment as per manufacturer recommendations. Note: (i) Service will be carried out through Service Engineer of Manufacturer only. The service engineer so hired should be the manufacturer employee only. No employee of authorized dealer shall be hired for servicing of VCB. (ii) The cost of minor spare parts i.e nut and bolts, springs, grommets, dust cover, ring of isolator contacts, clips, pin for release prop. "Y" Phase shround, over ride stop pin etc essentially required to make the panel serviceable shall deemed to be included in the unit rate by contractor.
Repair /servicing /Calliberation to HT panel of make : Kirloskar having vacuum circuit breaker 11 KV rating of capacity 250 MVA and current rating up to 630 Amp by replacing defective/wornout part, adjustment of gaps for smooth operation all as detailed below:- (a) Cleaning of VCB with air blower and removing dust particals (b) Cleaning of insulating places of VCB by using CTC/CRC/Thinner as required and recommended. (c) Checking the arcing contact gap of vaccum intrupter if gap exceeds the permissible limis, readjust as recommended (d) Cleaning the main contacts to remove carbon or any other unwanted particals if visible. (e) Dismantling and cleaning the insulated surfaces and arc barrier with CTC and CRC. (f) Checking/ repair replacement of all electrical/ manual operation of panel including measuring IR values. (g) Checking of all nuts/ bolts. springs, levers, latches, connectors etc. and adjustments as required and recommended. (h) Recording IR values of CTs and PTs (j) Cleaning of bus bar spout. (k) Cleaning of all moving parts for proper functioning of VCB and adjustment as per manufacturer recommendations. Note: (i) Service will be carried out through Service Engineer of Manufacturer only. The service engineer so hired should be the manufacturer employee only. No employee of authorized dealer shall be hired for servicing of VCB. (ii) The cost of minor spare parts i.e nut and bolts, springs, grommets, dust cover, ring of isolator contacts, clips, pin for release prop. "Y" Phase shround, over ride stop pin etc essentially required to make the panel serviceable shall deemed to be included in the unit rate by contractor.
S&F in replacement of plug & socket assembly suitable for VCB 11 KV complete all as specified.
S&F in replacement of manual spring charging handle suitable for VCB/OCB 11 KV complete all as specified.
S&F in replacement of TNC switch suitable for VCB/OCB 11 KV Panel complete all as specified.
S&F in replacement of electric hooter suitable for VCB 11 KV Panel complete all as specified.
Taking down unservicable triping coil from HT VCB and supply and fixing new triping coil 30 volt DC suitable for 11KV HT panel of make : Kirloskar ,cat part no as per OEM of existing panel complete all as directed and specified by Engr-in-charge.
Taking down unservicable triping coil from HT panel and supply and fixing new Master Trip Relay 30 V DC suitable for 11 KV HT panel for protection system complete all as directed and specified by Engr-in-chagre. Make: ABB, model no: RXMVB2 or technocommerically equivalant model in Schneider / Kirloskar /Alstom.
Taking down unservicable triping circuit supervision relay and S&F new trip circuit supervision relay of 30 V DC suitable for 11 KV HT panel for protection system complete all as directed and specified by Engr-in-chagre. Make: ABB model no : RXI series or technocommerically equivalant model of Siemens/ Schneider.
Taking down unservicable triping circuit supervision relay and S&F new trip circuit supervision relay of 110-125 V DC suitable for 11 KV HT panel for protection system of make: ABB model no : RXI series or technocommerically equivalant of Siemens/ Schneider complete all as directed and specified by Engr-in-chagre.
Taking down unservicable over current and earth fault relay and S&F new over current and earth fault relay suitable of 30 V DC suitable for 11 KV HT panel for protection system of make:Easergy of Schneider of P3 series or technocommerically equivalant of ABB /Siemens complete all as directed and specified by Engr-in-chagre. as specified and directed by the Engineer-in-Charge. (Note: T&P and ladder for painting will be deemed included in the quoted rate)
Taking out retrieved rubber mat any type and supply and laying synthetic rubber insulated mats 2.5mm thick for voltage upto 11 KV for electrical purpose as per IS 15652-2006 (superceding IS 5424) suitable for electrical shock safety of sizes 2m x 1m.
vishesh engineers
dinesh enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .